Download user guide, user manual, owner manual and instructions guide
5 600 brands
1 870 000 user's guides
Search a brand
Advanced Search



Our partners wish to propose you the following products


Visit ACT official site

User manual ACT ACT2000 - ACCESS CONTROL UNIT - INSTALLERS INSTRUCTIONS

Diplodocs help download the user guide ACT ACT2000 - ACCESS CONTROL UNIT - INSTALLERS INSTRUCTIONS.



Download the user manual ACT ACT2000  
Download the complete
user guide (80 Ko)
Need help, support, reviews, tips or troubleshooting for your ACT ACT2000 products ?


You may also download the following manuals related to this product:
ACT ACT2000
ACT ACT2000 INSTALLATION DIAGRAMS
ACT ACT2000 ACCESS CONTROL UNIT - OPERATOR INSTRUCTIONS

This product, although classified under the brand ACT, may have been manufactured by ACCESS CONTROL TECHNOLOGY after mergers, acquisitions, or a change in name.

Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
User guide ACT ACT2000 - ACCESS CONTROL UNIT - INSTALLERS INSTRUCTIONS

Detailed instructions for use are in the User's Guide.

QUICK PROGRAMMING GUIDE 1. 4. Setting site code . Enter the installer code. . Use 0 to scroll to Card Setup menu. . Press ü to enter the card setup menu. . Press ü to enter the site code. . Use keys 0-9 to enter the eight digit ACT site code. . Use 0 to exit the menu. Changing Installer code. . Enter installer code. . Use 0 to scroll to Change Pin menu. . Press ü to enter change pin menu. . Use keys 0-9 to enter new pin. . Use keys 0-9 to verify pin. . The controller will display Accepted , the new pin is set. . Use 0 to exit the menu. Enabling cards . Enter the operator code. . Press ü to enter the user set-up menu. . Press ü to enter the enable menu. For a single card: . Use 0 to scroll to the desired card. . Press ü to enable the card. For a range of cards: . Use keys 0-9 to enter the first card. Press ü. . Use keys 0-9 to enter the last card. Press ü. . Use X to exit from the menu. 5. 2. Disabling cards . Enter the operator code. . Press ü to enter the user set-up menu. . Press 0, then ü to enter the enable menu. For a single card: . Use 0 to scroll to the desired card. . Press ü to disable the card. For a range of cards: . Use keys 0-9 to enter the first card. Press ü. . Use keys 0-9 to enter the last card. Press ü. . Use X to exit from the menu. 6. 3. Changing relay and output active time. . Enter the installer code. . Use 0 to scroll to Door Settings menu. . Press ü to enter the door settings menu. . Use 0 to scroll to the door required. . Press ü to enter the door menu. . Use 0 to scroll to timers menu. . Press ü to enter the timers menu. . Use 0 to scroll to the required timer menu. . Press ü to enter selected timer menu. . Use keys 0-9 to enter the time you want the relay or output to stay active. . Use 0 to exit the menu. Setting Time and Date . Enter the operator code . Use 0 to scroll to "Set Date/Time" . Press ü to select. . Use numeric keys 0-9 to Enter the year . Press ü . Repeat for month, day , hour and minute. . New time will be displayed. Press ü to Accept. . Use X to exit from the menu. 7. Factory default codes: Operator: 123456 Installer: 999999 Adding a remote door (ACT2000 Only) . Enter the installer code. . Use 0 to scroll to Communications menu. . Press ü to enter the Communications menu. . Use 0 to scroll to Remote doors menu. . Press ü to enter the Remote dooors menu. . Use 0 to scroll to the required door. . Press ü to select the door.Use 0 to select Enable/Disable. . Press ü to Enable or Disable the door as selected. . Use 0 to exit the menu. · · · · Visit our website: www.accesscontrol.ie Unit 8, Tallaght Business Park, Whitestown, Dublin 24, Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587 Copyright © 2002 Access Control Technology Ltd. (18-00008-00) As with any access control system, always ensure that there is an alternate means of escape in the event of the unit failing to operate due to power loss or in the event of fire. Don't forget to keep a record of your Site Code for future use. Don't forget to change the programming code to something known only to yourself. Always remember to place the supplied Varistor across the terminals of the door strike coil to protect the relay contacts. Always remember to factory default the controller before you start programming. INSTALLATION NOTES IMPORTANT ACT1000/2000 Access Control Unit (Installers Instructions) Installer Menu System Settings 0 3 0 9 9 9 9 9 9 (This is the default code) 0 8 8 Installer Menu System Settings Door Settings Communications Card Setup Diagnostics Change PIN Factory Default 3 0 8 Operation Display Pin Length Fire Doors User Tracking Outputs 0 3 Operation Pin Only No Learn No Exit PINs No User Limiting No One-To-One No Multiple No Display Backlight No Keypad Beep Yes Show Status Yes Show Events Yes Handshake No 8 ACTWin Checklist Diagnostics 0 Version Reader Test Last Reset 8 * On the ACT2000 you will first be prompted to select which door to set up. 8 Door Settings* Operation Alarms Timers Reporting Timed Actions Assign Name 0 Operation Push Button Yes Locksaver No Chime No Guest Button No Exit Always No Interlock No Silent No Exit PIR No Failsafe No Card Setup 0 Site Code 1 Site Code 2 Card Format 8 0 Communications 0 Timed Actions Unlock Door Lock Door Pin Required Any Card Activate OP2 Activate OP3 Activate AUX Pin Only 8 8 1. Factory Default Controller 2. Enter the Communications Menu 3. Set Address = Controller number 4. Set Direct Conn = Yes (if direct connection to only ONE controller is required) or to No for a networked system. For more than one controller a Network Interface unit is required. 5. Connect the controller(s) to the PC. 6. From ACTWin, configure a New Database. 7. The number of the controller should match the controller addresses set up at Step 3. 8. Ensure that Comms is set up correctly - COM port, speed 9600, RS 232 for Direct Connect or RS 485 for Networked 9. From ACTWin, connect to the controllers. Alarms Door Forced Door Ajar Duress Alarm Door Open Acc Granted Acc Denied 0 Set Address Direct Conn Yes High Speed No Slave Mode No No Hist Log No Print All No Remote Doors Set Password 8 0 Reporting Door Ajar No Door Forced No Door Open No Door Closed No Push Button Yes Read Error No 8 No No No No No No 8 All other controller programming should be done using ACTWin as local changes will be overwritten during a download. Timers 0 When downloading from ACTWin, users may experience a brief interruption in the operation of the controller. This is normal, and the controller will return to normal once the download is completed. Relay Time OP 2 Time OP 3 Time Ajar Time AUX Time 8 5s 5s 5s 60s 2s The exact structure and contents of the Installer menu may vary slightly between different controller types, and between different versions of controller software.

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ACT ACT2000.

ACT offer a product for which we do not have the user manual? Let us know what you are looking for: site Internet, histoire, actualité, filiales, site Internet, mode d'emploi, driver, avis des utilisateurs, meilleur prix des produits, forum d'assistance aux problèmes, annuaire des marques, annuaire des constructeurs, répertoire des marques, répertoire des constructeurs, site Internet de la marque, site Internet du constructeur

Diplodocs allows you to download user manual ACT ACT2000, user guide ACT ACT2000, instructions ACT ACT2000, owner's manual ACT ACT2000, online manual ACT ACT2000.


Access web reviews ACT ACT2000, , Software.
Include the add-on to download manuals from your site, forum or blog Frequently Asked Questions Contact Diplodocs team Last searches
Last additions
Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.