Download user guide, user manual, owner manual and instructions guide
5 600 brands
1 870 000 user's guides
Search a brand
Advanced Search



Our partners wish to propose you the following products


Visit REVOX official site

User manual REVOX RECONNECT M203 - EIB & KNX BRIDGE

Diplodocs help download the user guide REVOX RECONNECT M203 - EIB & KNX BRIDGE.



Download the user manual REVOX RECONNECT M203  
Download the complete
user guide (333 Ko)
Need help, support, reviews, tips or troubleshooting for your REVOX RECONNECT M203 products ?


You may also download the following manuals related to this product:
REVOX RECONNECT M203 RS232 INTERFACE
REVOX RECONNECT M203 LOEWE INTERFACE
REVOX RECONNECT M203 PIONEER INTERFACE
Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
User guide REVOX RECONNECT M203 - EIB & KNX BRIDGE

Detailed instructions for use are in the User's Guide.

of of Re:connect M 203 EIB/ KNX Bridge Dominating Entertainment. Revox of Switzerland. M203 EIB/ KNX Re:connect Revox EIB Protocol This Operating manual describes the layout and the setting options on the M203 EIB-Bridge pages. The description does not include the Revox EIB Protocol that the EIB programmer must adhere to, so that the M203 EIB-Bridge can recognise the incoming EIB Group addresses and convert them into functions for the Revox Multiroom System. Apart from the main Group address X, the EIB Group addresses for the Revox Multiroom System are defined by Revox and cannot be modified. For a fast and simple introduction, you should download the following files from the Revox Homepage, www.revox.de/ Download/ Re:connect. 1. Revox EIB Protocol (pdf file) 2. EIB Configuration guide for Revox Multiroom System (Excel) 3. Sample programming (ETS file) 1 M203 EIB/ KNX Re:connect Table of Contents Revox EIB Protocol Table of Contents M203 EIB Bridge Installation Connection plan Connections M51 Link IN M51 Link OUT Serial interface RS 232 IR-Link Connection example EIB-Part Connection example Revox MR-Part Setup key #1 Slot Selection #2 EIB Address #2 EIB Debugger Released EIB products Overview Revox Multiroom System Technical Data Guarantee Included in delivery 1 2 3 3 3 4 4 4 5 6 7 8 9 9 10 11 12 13 14 14 14 2 M203 EIB/ KNX Re:connect M203 EIB-Bridge The M203 EIB-Bridge establishes the bridge between on the one side the Revox Multiroom System and on the other side, the EIB Domestic facility management system. The data exchange occurs between the M203 EIB serial interface and a serial EIB data interface for bus couplers. The M203 EIB-Bridge is only designed to handle communication with an EIB data interface and cannot receive any other protocols. The normal RS232 software (203-1) can be loaded using the Revox programmer. The EIB software is not copy protected. Installation The M203 interface can be installed easily and quickly. There are two types of fixing available. 1) The four outside fixing holes are used for a permanent installation. 2) Revox recommends using the two slots on the side for a variable installation. Connection plan Connection to the M51 Connection to further external M51- Interfaces IR-/ wall-mounted remote control M204/ M218 RS232 seriell interface Slotted hole Serial interface activity display Setup button 3 M203 EIB/ KNX Re:connect Connection: M203 with M51 Socket: M51 LINK IN The M203 interface is connected to the M51 LINK IN socket on the back of the M51 with the telephone cable supplied. If you want to use a different cable for some reason, you should use only a noncrossed, 4-core telephone cable with an RJ11 plug (6P4C modular). Cables up to 100 metres in length can be used. Connection: M203 with external interfaces Socket: M51 LINK OUT The M51 LINK OUT can be used to connect additional external interfaces to the M203 interface. These could, for example, be the M201 IR interface, a M200 Domotic interface, a M202 Ethernet interface or simply an additional M203. You should use only a noncrossed, 4-core telephone cable with an RJ11 plug (6P4C modular) for this connection. 4 M203 EIB/ KNX Re:connect Connection: M203 with serial interface Socket: RS232 Using the RS232 serial interface, the M203 EIB-Bridge can communicate with a serial data interface from an EIB system. Only Type FT 1.2 EIB data interfaces may be used, which originate from an authorised EIB supplier. You will find a listing of suitable products from GIRA and Merten on page 12. If the customer requires it, the keypad units shown for controlling the Revox Multiroom System, are programmed through an EIB tool, e.g. ETS3. The basis for the programming is the EIB protocol, which describes the communication between EIB bus connectors and the M203 EIB-Bridge. - Dimm + The graphic on page 7 shows an example of a configuration with an EIB domestic facility management system and the Revox Multiroom System. The length of the serial cable ­ null modem cable ­ must not exceed 10 metres. The null modem cable has a plug at each end. Male 5 2 3 Sub9D Male 5 2 3 Tuner CD Server Aux << >> - VOL + Local OFF Example: GIRA 6-way rocker switch 5 M203 EIB/ KNX Re:connect Connection: M203 with IR controller Socket IR- LINK Connect the small M204 IR receiver, which is available in four different models, to the IR Link. Now you can locate the M51 in a concealed location or outside the normal range of your remote control, without having to forego any of the convenience of using the remote control. The connection to an IR receiver or a wall-mounted remote control is done through the 3-pin, screw-fixable Phoenix plug connection. Revox recommends the use of a 2-core screened cable (microphone cable), where the screening is used as ground. This cable may be a maximum of 30 metres in length. Please ensure that you use the correct polarity when setting up as otherwise you might damage your equipment. Symbols: + Pos. voltage. 20V (DC) IN IR Signal Ground The maximum number of IR receivers that can be switched in parallel per M203 is 3. If you want to equip the (additional) rooms with an IR controller, you will need one M204 IR receiver for each M219 Additional room amplifier. You will find further information on this topic on page 11. An M218 wall-mounted remote control, with integrated IR receiver, can be connected instead of the M204 IR receiver. 6 M203 EIB/ KNX Re:connect Connection example ­ EIB part 7 M203 EIB/ KNX Re:connect Connection example ­ Revox MR part The EIB wall-mounted keypad units are installed in the required (additional) rooms, which make up the Revox Multiroom System. Each Additional room amplifier can be addressed over the M203 EIB-Bridge. Additionally, the Additional room amplifier can be integrated into a scene control. 8 M203 EIB/ KNX Re:connect Setup key Using the Setup key, you can call the M203 menu, which appears in the M51 display. Slot Selection If a second M203 (M200) is connected to the M51 Link output, a different address must be assigned through the slot selection so that both M203s don't occupy the same slot address. This would cause errors. In the case of a double assignment, neither of the two M203s would be shown in the M51 Version list. Slot addresse: #11 or #12 Using the Softkeys you can get to pages #1 and #2 Important: Only one M203 may be connected to the M51 Link for the address selection. You should separate the one M203 from the M51 Link while assigning the address to the other. If the addresses are correctly set, both M203s (M200) will appear in the M51 version list. You will find further information on this topic in the M51 manual in the Introduction chapter under the Version function. 9 M203 EIB/ KNX Re:connect Setup #2 - EIB Adresse The installer can assign different main group addresses, in the range from 0 to 15, when programming the EIB bus coupler units (BCU) for the Revox Multiroom controller keypads. The definition of the middle (Y) and lower (Z) group addresses is handled by the Revox protocol. An individual group address YZ results from each combination of (Multiroom) zone, room and function. The easiest way of calculating the individual YZ group addresses is to use the Excel Configuration guide that can be downloaded from the Revox Homepage, ww.revox.de / Download/ Re:connect. You can see the room and zone assignments of a maximum configuration Revox Multiroom System on page 13. The address for rooms 1 ­ 8 in the corresponding zones is set through DIL switches on the M219 Additional room amplifier. You will find a description in the M219 Additional room amplifier Operating manual. Another convenient way of determining the room addresses is the Revox Multiroom planner PC software, which can be downloaded free of charge from the Revox homepage. All keypads and/or their BCUs, which are used for controlling the Revox Multiroom System must have the same main group address (X). All other installation areas, e.g. lighting or heating, must be assigned a different main group address than the Revox EIB-Bridge. Otherwise, wrong interpretations may result. The main group address used (X) is set on page #2. Setting is done using the two softkeys ­ Address +. You do not have to confirm the address setting. Main address 5 was used in the above example. In this case, all BCUs and/or their keypad units, which are used to control the Revox Multiroom System must also have the main group address 5 so that the controls work correctly. 10 M203 EIB/ KNX Re:connect Important information · Parallel operation The Revox M217 Wallmounted display and/or the M218 wall-mounted control panel can be installed parallel to an EIB Controller. Both controllers have the same priority. The M217 wall-mounted display modifies the address within a zone. · Wall-mounted display retrofit Retrofitted M217 wallmounted displays modify the addresses within a zone. In this case, you should check the addresses of the Additional room amplifiers and if necessary, adjust the EIB addresses to the new constellation. · IR controller in the rooms If you want to have Multiroom control through a Revox remote control as well as through the EIB keypad units, an "invisible" IR control can be achieved using the small M204 IR receiver. The IR receiver is connected directly to the M219 Additional room amplifier and controls the devices within the Revox system. The M204 is available in four different models. Setp #2 ­ EIB Debugger There is an information window in the middle of page #2, which gives an overview of the activity on the EIB data interface. The following activities are logged: Resend The number of repetitions when the EIB data interface doesn't respond to a telegram the first time. Acknowledge The number of confirmations sent to the EIB data interface. Init The number of BCU initialisations. As a rule, only one initialisation is carried out after commissioning. Receiver The number of received EIB protocols. Transmit The number of EIB protocols sent to the EIB data interface. 11 M203 EIB/ KNX Re:connect Approved data interfaces and BCUs The following data interfaces, including BCUs, have been tested and released by Revox: GIRA FT1.2 Serial data interface GIRA Part no.: 0504 xx Suitable BCU: BCU2.1 GIRA Part no.: 0645 xx Merten Combi-interface with integrated BCU2: Merten Part no.: 6816 Because other EIB products from other companies are also certified, it is theoretically possible to work with them. However, Revox gives no guarantee if you choose to work with one of such products. 12 M203 EIB/ KNX Re:connect Revox Multiroom System overview The overview shows the maximum number of (Additional) rooms in a Revox Multiroom System, if no M217 Wall-mounted display is used and if the room control is done through the EIB system. One less room per zone is available for each M217 Wall-mounted display which is connected to the M219 Additional room amplifier. On the other hand, installing M218 Wall-mounted keypads or M204 IR receivers in parallel to the EIB System does not reduce the number of rooms with a zone. The following Operating manuals contain a detailed description of the Revox Multiroom System. · Multiroom Module (MK 1 ­ 3) · M219 Additional room amp. · M217 Wall-mounted display 13 M203 EIB/ KNX Re:connect Technical data IR-LINK: + IN Dimensions: Weight: Power consumption: Max. cable length: Max. cable length: E & OE Product subject to technical modifications. Description: Version M203-3 0.70 Positive voltage 10-20V (DC) IR signal Ground (GND) 113 x 25 x 50 mm (WxHxD) 150 g 35 mA (without IR receiver) 100 m (M203- M51) 30 m (M203 - IR receiver) Guarantee The guarantee period is 24 months from the date of purchase. Your dealer should be your first contact if you need service. If he can't give you the help you need, send your M203 EIBBridge carriage free and without any accessories to your national Sales Office. Please supply a complete description of the problem and a full return postal address. Included in delivery M203 EIB-Bridge M51 Link cable ( 2 m ) Serial PC cable (1:1 ­ length 2 m) RS232 Cross adapter Manual 14 M203 EIB/ KNX Re:connect GERMANY Revox GmbH, Am Krebsgraben 15, D-78048 VS-Villingen Telefon +49 7721 8704 0, Fax +49 7721 8704 29 info@revox.de, www.revox.de SCHWEIZ Revox Schweiz AG, Wehntalerstrasse 190, CH-8105 Regensdorf Telefon +41 44 871 66 11, Fax +41 44 871 66 19 info@revox.ch, www.revox.ch Zentralservice Revox GmbH, Am Krebsgraben 15, D-78048 VS-Villingen Telefon +49 7721 8704 43, Fax +49 7721 8704 49 info@revox.de Manual M203 EIB/ KNX Bridge / Part no.: 10.30.3072 15

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual REVOX RECONNECT M203.

REVOX offer a product for which we do not have the user manual? Let us know what you are looking for: user guide, owner's manual, online manual, operating instructions, quick start guide, mounting instructions, schematics, service manual, installation instructions, RTFM.

Diplodocs allows you to download user manual REVOX RECONNECT M203, user guide REVOX RECONNECT M203, instructions REVOX RECONNECT M203, owner's manual REVOX RECONNECT M203, online manual REVOX RECONNECT M203.


REVOX RECONNECT M203, , DVD Player, DVD Recorder, Home Theater, Amplifier & Hi-Fi Audio.
Include the add-on to download manuals from your site, forum or blog Frequently Asked Questions Contact Diplodocs team Last searches
Last additions
Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.