Download user guide, user manual, owner manual and instructions guide
5 600 brands
1 870 000 user's guides
Search a brand
Advanced Search



Our partners wish to propose you the following products


User manual ULINE ORIGINS 29R - INSTALL GUIDE

Diplodocs help download the user guide ULINE ORIGINS 29R - INSTALL GUIDE.



Download the user manual ULINE ORIGINS 29R  
Download the complete
user guide (939 Ko)
Need help, support, reviews, tips or troubleshooting for your ULINE ORIGINS 29R products ?


You may also download the following manuals related to this product:
ULINE ORIGINS 29R
ULINE ORIGINS 29R SUPPLEMENTARY GUIDE
Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
User guide ULINE ORIGINS 29R - INSTALL GUIDE

Detailed instructions for use are in the User's Guide.

Installation Guide 29R Refrigerator www.U-LineService.com Phone (414) 354-0300 · FAX (414) 354-7905 Service & Parts Tech Lines Phone (800) 779-2547 · FAX (414) 354-5696 OnlineService@U-Line.com ©2005 U-Line Corporation 02/2005 29R Refrigerator Contents Exterior Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Cut-Out Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Product Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Door Swing/Clearances Information . . . . . . . . . . . . . . 4 Reversing the Door. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Other Site Requirements . . . . . . . . . . . . . . . . . . . . . . . . 6 Custom 1/4" Thick Door Panel Insert . . . . . . . . . . . . . . 6 Checking Door Alignment . . . . . . . . . . . . . . . . . . . . . . 7 Adjusting Door Alignment . . . . . . . . . . . . . . . . . . . . . . 7 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 8 Leveling Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Installation of the 29R . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Grille Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Glass Shelf Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Initial Start-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Start-Up Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . 10 Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 1 Follow Safety Precautions IMPORTANT PLEASE READ all instructions completely before attempting to install or operate the unit. · This unit requires connection to a grounded (threeprong), polarized receptacle that has been placed by a qualified electrician in accordance with applicable electrical codes. Safety Alert Definitions Safety items throughout this guide are labeled with a Danger, Warning or Caution based on the risk type: DANGER Danger means that failure to follow this safety statement will result in severe personal injury or death. WARNING Warning means that failure to follow this safety statement could result in serious personal injury, or death. CAUTION Caution means that failure to follow this safety statement may result in minor or moderate personal injury, property or equipment damage. www.U-LineService.com 2 02/2005 29R Refrigerator General Precautions Use this appliance for its intended purpose only and follow these general precautions along with those listed throughout this guide: 2 Inspect and Plan You have received a carton containing your 29R Refrigerator with a package inside containing a User Manual and a Product Registration Card. Complete and mail the Product Registration Card or register online at www.U-LineService.com. Once your unit is installed, keep the User Manual and this Installation Guide in a safe place for future reference. 29R units are available in vinyl clad cabinets with matching doors which have a slightly contoured handle across the top and are reversible. The doors have recessed front panels that will accept a custom 1/4 inch thick door panel. Units have three tempered glass shelves. Please carefully follow the directions that apply to your unit and your intended design. WARNING SHOCK HAZARD -- Electrical Grounding Required. · Keep the unit unplugged throughout installation except during testing. · Never remove the round grounding prong from the plug and never use a two-prong grounding adapter. · Never use an extension cord to connect power to the unit. · Always keep your working area dry. CAUTION · Use care when moving and handling the unit. Use gloves to prevent personal injury from sharp edges. · Do not lift the unit by the door or door handle. · Do not install the unit behind closed doors or in any way that would obstruct airflow to the front grille, which may cause the unit to malfunction. Tools/Materials Required · Screwdrivers -- slotted and Phillips head · 1/4-inch thick door panel material and cutting tools Inspection Unwrap and inspect the unit on a flat, level surface capable of supporting its entire weight. Exterior Cleaning (As Required) Black and White Models: Black and white surfaces may be cleaned with a mild detergent and warm water solution. Do not use solventbased or abrasive cleaners. Use a soft sponge and rinse with clean water. Wipe with a soft, clean towel to prevent water spotting. 02/2005 3 www.U-LineService.com 29R Refrigerator 3 Prepare Site Your U-Line product has been designed for either freestanding or built-in installation. When built-in, your unit does not require additional air space for top, sides or rear. However, the front grille must NOT be obstructed and clearance is required for electrical connections in the rear. Note: Unit can NOT be installed behind a closed cabinet door. Product Dimensions 23" Including Handle Cut-Out Dimensions Filler Panel (Not Provided by U-Line) ­ May Be Added Above or Below Unit to Enclose for a Built-In Look 28-1/2" 20-13/16" Figure 2 Typical Counter Height 34-1/4" to 35-1/8" Cut-Out Height 28-5/8" to 28-7/8" Door Swing/Clearances Information See Electrical Specifications for Power Supply 23" Minimum Units have a zero clearance for the door to open 90° (see Figure 3). U-Line recommends a minimum door clearance of 1/4" to accommodate the handle if the unit is right-hand hinged and installed next to a wall or similar type of structure. 21-1/16" Wall 1/4" Min. Figure 1 Follow the cut-out drawing in Figure 1. The 21-1/16" width allows 1/4" for ease in installation and removal of the unit. 24" is the counter depth in most installations. The unit is 23" deep including the door and handle (see Figure 2). Note: It is recommended that the unit is level. 20-7/16" 90° Door Swing 22-3/8" Figure 3 www.U-LineService.com 4 02/2005 29R Refrigerator Reversing the Door All units may be left- or right-hand opening. Note: The grille should not yet be installed. If it has been installed, remove it for door reversing. See Page 9. To reverse the door: 1. Remove top hinge from cabinet (three screws). See Figure 4. Hold door to keep it from falling. 2. Lift the door off the bottom hinge. 5. Relocate plastic spacer/ bushing on bottom of door to opposite side, and place door on bottom hinge pin. See Figure 8. Clean out bushing hole in door bottom with a screwdriver if necessary. 6. Remove plastic hole plug from door handle and relocate on opposite side. See Figure 9. Bushing Figure 8 Hinge Plastic Plug Hole Plastic Plug Hole Screw Right Side Door Swing Right Side Hinge Invert Screw Invert Hinge Left Side Door Swing Figure 4 Figure 5 3. Remove bottom hinge from cabinet (two screws). See Figure 5. Remove screws on opposite side of cabinet (Figure 6). Note that there may be a nut behind one or both screws on either side. Figure 9 7. Remove pivot screw from top hinge, invert screw and reinstall pivot screw in top hinge. See Figure 9. 8. Remove three plastic screw plugs from hinge holes, top of cabinet, opposite side. Be careful not to scratch cabinet. See Figure 10. 9. Place door on lower hinge pin. Invert and install upper hinge on door. Figure 10 Figure 6 Figure 7 4. Install hinge on opposite side, bottom of cabinet. See Figure 7. Replace nut on back side where installed. Align hinge outer edge with cabinet before tightening screws. 02/2005 5 www.U-LineService.com 29R Refrigerator 10. Fasten upper hinge to unit (three screws). Partially tighten screws. See Figure 11. 11. Adjust door to assure proper seal. Tighten upper and lower hinge screws securely. 12. Replace three plastic plugs removed in Step 8 into holes on top of unit. Replace screws in holes in bottom of unit on opposite side. 4 Prepare and Install Door Panel Units will accept a Custom 1/4" Thick Insert to harmonize with or accent the surrounding decor. If this treatment is not included in this installation, go on to 5 Adjust Door. Custom 1/4" Thick Door Panel Insert Figure 11 Door Panel Preparation A custom door panel can be inserted into the doorframe. Custom door panels can be flat or raised, as long as the maximum panel thickness where inserted into the door reveal (channel) is 1/4"-thick. For raised panels, the depth of the reveal is 1/4" on all four sides. Other Site Requirements Power Supply The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A circuit (normal household current). See Electrical Specifications on Page 8. IMPORTANT Raised panels will reduce the door's 90° swing/zero clearance if the unit is installed next to a wall or similar type of structure (see Page 4). Cut the panel insert to the following dimensions. Custom 1/4" Dimensions: Width: Height: 19-13/16" 21-13/32" Environmental Requirements The surrounding air temperature must be at least 50°F (10°C) but must not exceed 110°F (40°C). Units may be installed outdoors in a covered area. The unit must not be located near heat-generating equipment or in direct sunlight. The door panel must not weigh more than 20 lbs. Door Panel Installation Install the insert as follows: CAUTION Use care when handling the insert. Insert edges may be sharp. 1. Remove top hinge screw pin with a Phillips head screwdriver. Remove door by tilting forward and lifting off bottom hinge pin. www.U-LineService.com 6 02/2005 29R Refrigerator 5 Adjust Door Checking Door Alignment The unit's door is aligned at the factory before shipment. However, its alignment could have been disturbed during shipment or during door panel installation. IMPORTANT Properly aligned, the door's gasket should be firmly in contact with the cabinet all the way around the door (no gaps). 1. Carefully examine the door's gasket to assure that it is firmly in contact with the cabinet. 2. Pull door gasket out of groove (top edge of door only). Start in the middle and pull outward, moving toward the edge (see Figure 13). This may take some force. 3. Remove two outside screws holding door handle. Slightly separate door handle from door (see Figure 14). 4. Pull handle up and off. 5. Slide custom door panel insert into 1/4-inch channel in door front. 6. Holding door gasket out of the way, replace handle on door, making sure it is seated properly on insert and that screw holes line up. 7. Install two small screws removed in Step 3. 8. Starting at the corners and working inward, push door gasket into place on door. 9. Place door on bottom hinge pin and install upper hinge screw. 10. Go on to 5 Adjust Door. Note: When inspecting door alignment, make sure the door gasket is not pinched on the hinge side of the door. 2. If the door is properly aligned, go on to 6 Prepare Power Supply. If it is not, use the following procedure. Figure 12 Figure 13 Adjusting Door Alignment 1. Loosen (do not remove) top and bottom hinge screws. See Figure 15. 2. Align door squarely with cabinet. Make sure gasket is firmly in contact with cabinet all the way around the door (no gaps). 3. Tighten bottom hinge screws. 4. Tighten top hinge screws. Go on to 6 Prepare Power Supply. Figure 15 Figure 14 02/2005 7 www.U-LineService.com 29R Refrigerator 6 Prepare Power Supply 7 Level the Unit Electrical Specifications CAUTION Electrical installation must observe all state and local codes. This unit requires connection to a grounded (threeprong), polarized receptacle that has been placed by a qualified electrician. The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A power supply (normal household current). An individual, properly grounded branch circuit or circuit breaker is recommended. GFCI (ground fault circuit interrupter) is usually not required for fixed location appliances and is not recommended for your unit because a GFCI could be prone to nuisance tripping. However, be sure to consult your local codes. See Figure 16 for recommended receptacle location. Leveling Information Note: It is recommended that the unit is level. Use a level to check the levelness of the unit from front to back and from side to side. Level should be placed along top edge and side edge as shown (see Figure 17). Go on to 8 Install the Unit. Check Level Figure 17 23" Minimum 7" 1-1/2" Figure 16 WARNING SHOCK HAZARD -- Electrical Grounding Required. · Never remove the round grounding prong from the plug and never use a two-prong grounding adapter. · Never use an extension cord to connect power to the unit. Go on to 7 Level the Unit. www.U-LineService.com 8 02/2005 29R Refrigerator 8 Install the Unit Installation of the 29R 1. Plug in the power cord. 2. Gently push the unit into position. Be careful not to entangle the electrical cord. 3. Re-check the leveling, from front to back and side to side. Make any necessary adjustments. The unit's top surface should be approximately 1/8" below the countertop or filler panel. Grille Hook-Hinge Unit Base Front Lip Hook-Hinge Figure 19 5. Insert the screw. Do not overtighten. 6. Reinstall control knob. Grille Installation 1. Locate and remove the grille screw from the cabinet, using a standard blade screwdriver (or a 1/4" nutdriver). See Figure 18. Glass Shelf Installation 1. Carefully remove the glass shelves from the packaging. 2. Slide the shelves onto lower sets of ribs, making sure the decorative graphics are on the underside of the shelves. While edge strips go toward the rear and silver edge strips go toward the front. See Figure 20. Grille Screw Figure 18 2. Remove the control knob by pulling it away from the cabinet. 3. Identify the grille screw hole on the grille itself. It is located toward the top of the middle recessed section of the grille. 4. Place the two hook-hinges (located on the rear bottom side of the grille) onto the front lip of the unit base. Swing the grille up into position, aligning the grille screw hole on the grille to the grille screw hole on the cabinet. See Figure 19. Figure 20 02/2005 9 www.U-LineService.com 9 Start-Up for the First Time Who to Call Service Information If the need for service arises, contact the dealer from whom the unit was purchased. State the Model Number and Serial Number and explain the problem. The Model and Serial Number plate is located inside unit at upper right hand corner. If you need to locate a service company, you can go online at www.U-LineService.com and search for a service company by zip code. Initial Start-Up The unit is shipped with the control preset to a mid-point setting between 4 and 5. Assure that setting was not altered in shipment. No other adjustments should be necessary at this time. For information about Adjusting the Temperature Control, see the User Manual. Start-Up Troubleshooting Q: Problem Unit does not appear to turn on when plugged in. A: Solution Make sure outlet has power (circuit breaker has not tripped). Be sure that control is not turned to the off position. Make sure the on/off switch is turned on. IMPORTANT See the User Manual's Troubleshooting Guide for more solutions. For more than four decades, U-Line has distinguished itself as the leader in built-in undercounter ice making, refrigeration and wine storage appliances. U-Line Corporation, located in Milwaukee, WI, is a family operated manufacturer of built-in undercounter icemakers, Combo® icemaker/refrigerators, Wine Captain® wine storage units, refrigerators, refrigerated drawers and refrigerator/freezers. ©2005 U-Line Corporation Publication No. 30065E 02/2005

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ULINE ORIGINS 29R.

ULINE offer a product for which we do not have the user manual? Let us know what you are looking for: user guide, owner's manual, online manual, operating instructions, quick start guide, mounting instructions, schematics, service manual, installation instructions, RTFM.

Diplodocs allows you to download user manual ULINE ORIGINS 29R, user guide ULINE ORIGINS 29R, instructions ULINE ORIGINS 29R, owner's manual ULINE ORIGINS 29R, online manual ULINE ORIGINS 29R.


Access web reviews ULINE ORIGINS 29R, , Cold Storage : Fridge, Freezer & Wine Fridge.
Include the add-on to download manuals from your site, forum or blog Frequently Asked Questions Contact Diplodocs team Last searches
Last additions
Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.