BI-95 Ice Maker
www.U-LineService.com Phone (414) 354-0300 · FAX (414) 354-7905 Service & Parts Tech Lines Phone (800) 779-2547 · FAX (414) 354-5696 OnlineService@U-Line.com
©2005 U-Line Corporation 02/2005
BI-95 Ice Maker
Contents
Exterior Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cut-Out Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . Door Swing/Clearances Information . . . . . . . . . . . . . . Reversing the Door. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Other Site Requirements . . . . . . . . . . . . . . . . . . . . . . . . Custom 1/4" Thick Door Panel Insert . . . . . . . . . . . . . . Checking Door Alignment . . . . . . . . . . . . . . . . . . . . . . Adjusting Door Alignment . . . . . . . . . . . . . . . . . . . . . . Water Supply Connection . . . . . . . . . . . . . . . . . . . . . . . Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . Leveling Information . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation of the BI-95 . . . . . . . . . . . . . . . . . . . . . . . . . Grille Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation Troubleshooting . . . . . . . . . . . . . . . . . . . . . Initial Start-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Start-Up Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 4 4 4 5 6 6 7 7 8 9 9 10 10 10 11 11 12
1 Follow Safety Precautions
IMPORTANT
PLEASE READ all instructions completely before attempting to install or operate the unit. · This unit requires connection to the water supply. Improper hook-up can result in substantial property damage! If you are unsure of your ability to safely connect the water supply to the unit, consult a licensed plumber for assistance. · This unit requires connection to a grounded (threeprong), polarized receptacle that has been placed by a qualified electrician in accordance with applicable electrical codes.
Safety Alert Definitions
Safety items throughout this guide are labeled with a Danger, Warning or Caution based on the risk type:
DANGER
Danger means that failure to follow this safety statement will result in severe personal injury or death.
WARNING
Warning means that failure to follow this safety statement could result in serious personal injury, or death.
CAUTION
Caution means that failure to follow this safety statement may result in minor or moderate personal injury, property or equipment damage.
www.U-LineService.com
2
02/2005
BI-95 Ice Maker
General Precautions
Use this appliance for its intended purpose only and follow these general precautions along with those listed throughout this guide:
2 Inspect and Plan
You have received a carton containing your BI-95 Ice Maker with a package inside containing a User Manual, a Product Registration Card and water connection parts. Complete and mail the Product Registration Card or register online at www.U-LineService.com. Once your unit is installed, keep the User Manual and this Installation Guide in a safe place for future reference. BI-95 units are available in vinyl clad cabinets with matching doors which have a slightly contoured handle across the top and are reversible. The doors have recessed front panels that will accept a custom 1/4 inch thick door panel. Please carefully follow the directions that apply to your unit and your intended design.
WARNING
SHOCK HAZARD -- Electrical Grounding Required. · Keep the unit unplugged throughout installation except during testing. · Never remove the round grounding prong from the plug and never use a two-prong grounding adapter. · Never use an extension cord to connect power to the unit. · Always keep your working area dry.
CAUTION
· Use care when moving and handling the unit. Use gloves to prevent personal injury from sharp edges. · Do not lift the unit by the door or door handle. · Do not install the unit behind closed doors or in any way that would obstruct airflow to the front grille, which may cause the unit to malfunction.
Tools/Materials Required
· Screwdrivers -- slotted and Phillips head · 1/4-inch OD copper tubing and shut-off valve for water supply line · 1/4-inch thick door panel material and cutting tools
Inspection
Unwrap and inspect the unit on a flat, level surface capable of supporting its entire weight.
Exterior Cleaning
(As Required) Black and White Models: Black and white surfaces may be cleaned with a mild detergent and warm water solution. Do not use solventbased or abrasive cleaners. Use a soft sponge and rinse with clean water. Wipe with a soft, clean towel to prevent water spotting.
02/2005
3
www.U-LineService.com
BI-95 Ice Maker
3 Prepare Site
Your U-Line product has been designed for either freestanding or built-in installation. When built-in, your unit does not require additional air space for top, sides or rear. However, the front grille must NOT be obstructed and clearance is required for water and electrical connections in the rear. Note: Unit can NOT be installed behind a closed cabinet door.
Product Dimensions
17" Including Handle
24-3/4"
Cut-Out Dimensions
Filler Panel (Not Provided by U-Line) May Be Added Above or Below Unit to Enclose for a Built-In Look
13-15/16"
Figure 2
Door Swing/Clearances Information
Typical Counter Height 34-1/4" to 35-1/8" Cut-Out Height 24-7/8" to 25" 8" 14-3/16" 1/4" Min.
18-1/2" Minimum See Electrical Specifications for Power Supply
Units have a zero clearance for the door to open 90° (see Figure 3). U-Line recommends a minimum door clearance of 1/4" to accommodate the handle if the unit is right-hand hinged and installed next to a wall or similar type of structure. Note: When a raised panel is used, additional clearance is needed for easy removal of ice bin if door hinge side is installed adjacent to wall.
Wall
Figure 1 Follow the cut-out drawing in Figure 1. The 14-3/16" width allows 1/4" for ease in installation and removal of the unit. 24" is the counter depth in most installations. 18-1/2" depth includes the door, handle and water line connection (see Figure 2).
14-3/8"
IMPORTANT
It is extremely important that the unit sits on a level surface, as it does not have feet levelers. If it is not level, the ice mold will not fill evenly. Figure 3
90° Door Swing
15-1/2"
www.U-LineService.com
4
02/2005
BI-95 Ice Maker
Reversing the Door
All units may be left- or right-hand opening. Note: The grille should not yet be installed. If it has been installed, remove it for door reversing. See Page 10. To reverse the door: 1. Remove top hinge from cabinet (three screws). See Figure 4. Hold door to keep it from falling. 2. Lift the door off the bottom hinge.
5. Relocate plastic spacer/ bushing on bottom of door to opposite side, and place door on bottom hinge pin. See Figure 8. Clean out bushing hole in door bottom with a screwdriver if necessary. 6. Remove plastic hole plug from door handle and relocate on opposite side. See Figure 9.
Bushing
Figure 8
Hinge
Plastic Plug Hole
Plastic Plug Hole
Screw Right Side Door Swing Right Side Hinge Invert Screw Invert Hinge Left Side Door Swing
Figure 4
Figure 5
3. Remove bottom hinge from cabinet (two screws). See Figure 5. Remove screws on opposite side of cabinet (Figure 6). Note that there may be a nut behind one or both screws on either side.
Figure 9 7. Remove pivot screw from top hinge, invert screw and reinstall pivot screw in top hinge. See Figure 9. 8. Remove three plastic screw plugs from hinge holes, top of cabinet, opposite side. Be careful not to scratch cabinet. See Figure 10. 9. Place door on lower hinge pin. Invert and install upper hinge on door.
Figure 10 Figure 6 Figure 7
4. Install hinge on opposite side, bottom of cabinet. See Figure 7. Replace nut on back side where installed. Align hinge outer edge with cabinet before tightening screws.
02/2005
5
www.U-LineService.com
BI-95 Ice Maker
10. Fasten upper hinge to unit (three screws). Partially tighten screws. See Figure 11. 11. Adjust door to assure proper seal. Tighten upper and lower hinge screws securely. 12. Replace three plastic plugs removed in Step 8 into holes on top of unit. Replace screws in holes in bottom of unit on opposite side.
4 Prepare and Install Door Panel
Units will accept a Custom 1/4" Thick Insert to harmonize with or accent the surrounding decor. If this treatment is not included in this installation, go on to 5 Adjust Door.
Custom 1/4" Thick Door Panel Insert
Figure 11
Door Panel Preparation
A custom door panel can be inserted into the doorframe. Custom door panels can be flat or raised, as long as the maximum panel thickness where inserted into the door reveal (channel) is 1/4"-thick. For raised panels, the depth of the reveal is 1/4" on all four sides.
Other Site Requirements
Power Supply
The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A circuit (normal household current). See Electrical Specifications on Page 9.
IMPORTANT
Raised panels will reduce the door's 90° swing/zero clearance if the unit is installed next to a wall or similar type of structure (see Page 4). Cut the panel insert to the following dimensions. Custom 1/4" Dimensions: Width: Height: 12-15/16" 13-15/32"
Water Supply
The unit requires a 1/4-inch OD water supply line and a shut-off valve. For more information see Page 8.
Environmental Requirements
The surrounding air temperature must be at least 50°F (10°C) but must not exceed 110°F (40°C). Units may be installed outdoors in a covered area. The unit must not be located near heat-generating equipment or in direct sunlight.
The door panel must not weigh more than 20 lbs.
Door Panel Installation
Install the insert as follows:
CAUTION
Use care when handling the insert. Insert edges may be sharp. 1. Remove top hinge screw pin with a Phillips head screwdriver (see Figure 12). Remove door by tilting forward and lifting off bottom hinge pin.
www.U-LineService.com
6
02/2005
BI-95 Ice Maker
5 Adjust Door
Checking Door Alignment
The unit's door is aligned at the factory before shipment. However, its alignment could have been disturbed during shipment or during door panel installation.
IMPORTANT
Properly aligned, the door's gasket should be firmly in contact with the cabinet all the way around the door (no gaps). 1. Carefully examine the door's gasket to assure that it is firmly in contact with the cabinet. 2. Pull door gasket out of groove (top edge of door only). Start in the middle and pull outward, moving toward the edge (see Figure 13). This may take some force. 3. Remove two outside screws holding door handle. Slightly separate door handle from door (see Figure 14). 4. Pull handle up and off. 5. Slide custom door panel insert into 1/4-inch channel in door front. 6. Holding door gasket out of the way, replace handle on door, making sure it is seated properly on insert and that screw holes line up. 7. Install two small screws removed in Step 3. 8. Starting at the corners and working inward, push door gasket into place on door. 9. Place door on bottom hinge pin and install upper hinge screw. 10. Go on to 5 Adjust Door. Note: When inspecting door alignment, make sure the door gasket is not pinched on the hinge side of the door. 2. If the door is properly aligned, go on to 6 Prepare Plumbing. If it is not, use the following procedure.
Figure 12
Figure 13
Adjusting Door Alignment
1. Loosen (do not remove) top and bottom hinge screws. See Figure 15. 2. Align door squarely with cabinet. Make sure gasket is firmly in contact with cabinet all the way around the door (no gaps). 3. Tighten bottom hinge screws. 4. Tighten top hinge screws. Go on to 6 Prepare Plumbing. Figure 15
Figure 14
02/2005
7
www.U-LineService.com
BI-95 Ice Maker
6 Prepare Plumbing
CAUTION
Plumbing installation must observe all state and local codes. All water connections MUST BE made by a licensed/ qualified plumbing contractor. Failure to follow recommendations and instructions may result in damage and/or harm.
Water Line
WARNING
To prevent accidental electrocution, make certain that the floor surfaces surrounding the unit are dry whenever power is removed from, or applied to, the unit.
Figure 16
Figure 17
Water Supply Connection
When connecting the water supply, follow these guidelines: · Review the local plumbing codes before you install the unit. · Connect to the cold water supply. · The water pressure should be between 20 and 120 psi. · Install a shut-off valve in the 1/4 inch OD water supply line. · Connect sufficient tubing to the unit so that tubing may be looped, allowing the unit to be removed for cleaning and servicing (see Figure 18). However, make certain that the tubing is not pinched or damaged during installation. · U-Line recommends the use of copper tubing for installation. To connect to water supply: 1. Install the 1/4 inch OD copper water line from the main water source.
2. Locate the compression fitting and ferrule packed with the unit. Slide the compression fitting and ferrule over the 1/4-inch OD water supply line. Do not use thread sealing compound or tape. Using two wrenches, tighten the compression fitting on the supply line (see Figure 16). 3. Carefully bend the water supply line into position and connect the line to the solenoid valve (see Figure 17). Avoid kinking the water supply line.
Figure 18
IMPORTANT
Route the water supply line through the unit so it does not come into contact with any internal components other than the solenoid valve. See Figure 18. Normal operation creates some vibration. A water supply line contacting an internal component or cabinet wall can cause excessive noise during operation or damage to the line. 4. For recessed installations, allow extra water supply line length to provide slack for easy removal from the recessed area (see Figure 18). This will also safeguard against kinking the line. 5. Go on to 7 Prepare Power Supply.
www.U-LineService.com
8
02/2005
BI-95 Ice Maker
7 Prepare Power Supply
8 Level the Unit
Electrical Specifications
CAUTION
Electrical installation must observe all state and local codes. This unit requires connection to a grounded (threeprong), polarized receptacle that has been placed by a qualified electrician. The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A power supply (normal household current). An individual, properly grounded branch circuit or circuit breaker is recommended. GFCI (ground fault circuit interrupter) is usually not required for fixed location appliances and is not recommended for your unit because a GFCI could be prone to nuisance tripping. However, be sure to consult your local codes. See Figure 19 for recommended receptacle location.
Leveling Information
IMPORTANT
It is extremely important that the unit sits on a level surface, as it does not have feet levelers. If it is not level, the ice mold will not fill evenly. Use a level to check the levelness of the unit from front to back and from side to side. Level should be placed along top edge and side edge as shown (see Figure 20). Go on to 9 Install the Unit.
Check Level
Figure 20
18-1/2" Minimum 7"
1-1/2"
Figure 19
WARNING
SHOCK HAZARD -- Electrical Grounding Required. · Never remove the round grounding prong from the plug and never use a two-prong grounding adapter. · Never use an extension cord to connect power to the unit. Go on to 8 Level the Unit.
02/2005
9
www.U-LineService.com
BI-95 Ice Maker
9 Install the Unit
Installation of the BI-95
1. Open the water supply valve in the main water source. 2. Plug in the power cord. 3. Gently push the unit into position. Be careful not to kink the water supply line or entangle the electrical cord. 4. Re-check the leveling, from front to back and side to side. Make any necessary adjustments. The unit's top surface should be approximately 1/8" below the countertop. Figure 22 4. Insert the screw. Do not overtighten.
Hook-Hinge Unit Base Front Lip Grille
Grille Installation
1. Locate and remove the grille screw from the cabinet, using a standard blade screwdriver (or a 1/4" nutdriver). See Figure 21.
Installation Troubleshooting
Q: Problem
Water is leaking under the unit.
Grille Screw
A: Solution
A water leak under the unit is most likely caused by a bad connection in the water supply line. Make sure the water line's brass fitting is screwed tight to its valve and threaded correctly. Make sure that plumbers tape was NOT used; if it was remove all traces before reinstalling.
Figure 21 2. Identify the grille screw hole on the grille itself. It is located toward the top of the middle recessed section of the grille. 3. Place the two hook-hinges (located on the rear bottom side of the grille) onto the front lip of the unit base. Swing the grille up into position, aligning the grille screw hole on the grille to the grille screw hole on the cabinet. See Figure 22.
www.U-LineService.com
10
02/2005
BI-95 Ice Maker
10 Start-Up for the First Time
Start-Up Troubleshooting
Initial Start-Up
The on/off switch is located behind the front grille. A small opening in the top of the grille is provided to access the switch. Ensure that the switch is turned on. No setting adjustments should be necessary at this time. For information about Adjusting the Temperature Control, see the User Manual. As soon as the ice maker mold reaches the proper temperature, the ice maker mechanism will fill the mold with water. Note: The first cubes may be small because of air in the water line. After two hours, cubes will be standard size. The ice maker will continue to produce until the bin is Figure 23 full. You may interrupt production by raising the bin arm into an upright and locked position (see Figure 23). While the bin arm is locked, the unit will maintain temperature for ice storage.
Q: Problem
Unit does not appear to turn on when plugged in.
A: Solution
Make sure outlet has power (circuit breaker has not tripped). Make sure the on/off switch is turned on.
Q: Problem
Water does not appear to be flowing into unit.
A: Solution
Check that the water is connected and turned on and the line is not obstructed. Water coming into the unit may take an hour or more.
Q: Problem
The cubes produced during the first two to three hours of operation have been discarded. New cubes still appear cloudy.
A: Solution
This is normal and is caused by air being trapped in the cube during fast freezing.
IMPORTANT
It is possible that dirt or scale will dislodge in the water line. Always throw away all ice cubes made during the first twenty-four (24) hours of operation.
IMPORTANT
See the User Manual's Troubleshooting Guide for more solutions.
02/2005
11
www.U-LineService.com
Who to Call
Service Information
If the need for service arises, contact the dealer from whom the unit was purchased. State the Model Number and Serial Number and explain the problem. The Model and Serial Number plate is located inside unit at upper right hand corner. If you need to locate a service company, you can go online at www.U-LineService.com and search for a service company by zip code.
For more than four decades, U-Line has distinguished itself as the leader in built-in undercounter ice making, refrigeration and wine storage appliances.
U-Line Corporation, located in Milwaukee, WI, is a family operated manufacturer of built-in undercounter icemakers, Combo® icemaker/refrigerators, Wine Captain® wine storage units, refrigerators, refrigerated drawers and refrigerator/freezers.
©2005 U-Line Corporation Publication No. 30067E 02/2005
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ULINE ORIGINS BI-95. ULINE offer a product for which we do not have the user manual? Let us know what you are looking for: user guide, owner's manual, online manual, operating instructions, quick start guide, mounting instructions, schematics, service manual, installation instructions, RTFM. Diplodocs allows you to download user manual ULINE ORIGINS BI-95, user guide ULINE ORIGINS BI-95, instructions ULINE ORIGINS BI-95, owner's manual ULINE ORIGINS BI-95, online manual ULINE ORIGINS BI-95.ULINE ORIGINS BI-95, , Cold Storage : Fridge, Freezer & Wine Fridge. |
![]() |
Include the add-on to download manuals from your site, forum or blog | ![]() |
Frequently Asked Questions | ![]() |
Contact Diplodocs team | ![]() |
Last searches Last additions |
![]() |
Sitemap | ![]() |
|||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |