Detailed instructions for use are in the User's Guide.
GUIDE TO INSTALLATION OF THE B & K CK1.2 KEYPAD
MAIN IN 6 IN 7 IN 8 IN 8 FM IN 1 IN 2 IN 3 IN 4 IN 5
PAGE 1
Rev B 0104
S IMPLY B ETTER!
B&K
Thank you for choosing to install the B & K CK 1.2 Keypad for this system!
Please use this manual as a guide to connecting and mounting the Keypad. The CK1.2 keypad is preprogrammed at the factory to initially operate B & K CT products. It can be re-programmed using a Windows PC and the accompanying CD. See the Keypad Programming Manual on the CD for instructions on programming. B & K Components, Ltd. sells its products through authorized dealers. Buying from an authorized B & K Components, Ltd. dealer insures that you have a FACTORY WARRANTY on your B & K Components, Ltd. product. A warranty on B & K Components, Ltd. products is NOT VALID if the products have been purchased from an unauthorized dealer or an E-tailer or if the factory serial number has been removed, defaced orreplaced in any way.
Guide to Installation of the B & K CK1.2 Keypad
© 2004 B&K Components, Ltd. All rights reserved.
S IMPLY B ETTER!
B & K Components, Ltd. 2100 Old Union Road Buffalo, New York 14227 1.800.543.5252 In NY: 716.656.0026 Fax: 716.656.1291 E-mail: info@bkcomp.com On the web: www.bkcomp.com
B&K
Table of Contents
Features and Benefits Basic Controls and Displays Rear Panel Connections Programming Jack - Behind the Faceplate Terminate RJ-45's One to One Standard CT610/310/600 System Configuration Connecting To A CT610/310/600 Keypad Total Power Consumption B & K PT5 Preamp- Perfect for Adding Zones Keypads with Other B&K Preamp/Receivers IR Repeaters for Any Brand of Preamp/Receiver No Emitter for B & K Recievers & Preamps Connecting Slave Keypads Connecting Local TV's and Devices Mounting Programming White and Beige Wall Plate Included Filling Out the Operation Manual for the Client Specifications
1 2 3 4 4 5 6 7 7 8 8 9 9 10 11 11 11 12 13
S IMPLY B ETTER!
B&K
Page 1
Features and Benefits
Vast Programming Capacity The CK1.2 can be programmed with 44 IR commands for each of up to 20 components or devices. Additionally, you can label the commands with user friendly names that your client will find easy to use. One Touch Automates Operation The On, Off and all of the screen-labeled buttons can be programmed with macros of up to 190 steps (steps can include IR commands, delays of .1 to 99.9 seconds, and Jumps to another Page). Point Any Remote Control at the Keypad! The integrated IR pass through sends the commands of any of your client's infrared remote controls to components connected via flashers. If your client wants to use a remote control in any room, they simply point it at the B & K keypad. Automates Local TV's and the Central System! By connecting a flasher directly to the Keypad, you can program the IR commands and Macros to automate TV's and components placed in the zone. Two Way Communication With B & K Multi-Zone Receivers The keypad displays the status of the zone it controls in two ways: 1. The green status LED indicates when the zone is on or off. 2. The keypad displays the name of the currently selected source, regardless of how a new source is selected (by a remote control, the front panel controls or the keypad itself). Multiple Keypads within One Zone You can daisy-chain keypads within one zone. All keypads will correctly display the zone power status and the selected source. Ultra-Fast Programming via PC Software A vast database of more than one thousand brands instantly programs IR Codes for most components, B & K Batch Learning does the rest in a fraction of the time of any other system. Retains Programming Through Power Failures Your programming is safe in the event of a power failure of any length. The Non-Volatile Flash Memory keeps the program intact.
S IMPLY B ETTER!
B&K
Page 2
Basic Controls and Displays
LCD Buttons - Labels on the Screen change depending on what activity has been selected. For example, when CD is the activity, you'll see the labels change to Play, Stop etc. so that the CD can be controlled. Volume/Mute Buttons control the level of the sound. Change Buttons Change to the next channel, chapter, song or B&K sound preset; depen-ding on the selected activity. Backlight Button lights the keypad display & recalles status feedback on CT products. Main Button The Main button always returns you to the Main Menu so that you can select a new device (activity) or turn the system on or off.
MAIN CD SAT DVD TAPE NEWS JAZZ CLASS ROCK
Power LED Lights up when this Zone/Room is ON.
HOUSE AUDIO
PAGE 1
Screen Title Displays what Source is selected ( i.e. device or activity like "CD" or "SAT"). Main indicates the Main Menu for selecting a new device or activity. Page Button press to display any additonal pages of functions.
Remote Control Target conceals an IR (Infrared) Sensor which relays commands from hand held IR remote controls to components connected to Flashers.
MAIN CD SAT DVD TAPE NEWS JAZZ CLASS ROCK
HOUSE AUDIO
PAGE 1
S IMPLY B ETTER!
B&K
Page 3
Rear Panel Connections
MASTER (IN) Connects to the CT610/310/600 via a standard 4 Pair Twisted cable (typically referred to as CAT 5 cable) terminated with an RJ-45 plug.
Master Pin Out 1 - +12VDC IN 2 - KEYPAD DATA OUT 3 - GROUND 4 - N/C 5 - RS-232 RECEIVE INPUT 6 - GROUND 7 - STATUS IN 8 - +12VDC IN
SLAVE (OUT) Connects to the MASTER (IN) of any other same-zone keypads via an RJ-45 plug.
Slave Pin Out 1 - +12VDC IN 2 - KEYPAD DATA OUT 3 - GROUND 4 - N/C 5 - RS-232 SLAVE OUTPUT 6 - GROUND 7 - STATUS IN 8 - +12VDC IN
ALTERNATE MASTER (IN) The Alternate Master has two purposes in most systems: 1. You can use it instead of the MASTER (IN) when the cable from the CT610/310/600 is not terminated in an RJ-45 plug. 2. You can terminate a flasher for a local TV or component to terminals 2 and 4.
S IMPLY B ETTER!
B&K
Page 4
Programming Jack - Behind the Faceplate
The face plate is removed by prying up from the two screwdriver tabs at the base of the keypad. Once removed, the Programming Jack is revealed:
Programming Jack Connect to a laptop PC via the Serial cable included with the CK1.2 keypad. If your PC does not have a serial port, utilize a USB to serial converter.
Terminate RJ-45's One to One
You can terminate the RJ-45's using any color code, just connect them straight through; exactly the same color to pin on each end of the cable. Standard pre-terminated LAN (Local Area Network) cables work fine.
For convenience, the EIA 568B color scheme is listed below. The first color listed in the color pair is the dominant color of the wire. In other words, White/Orange is a white wire with orange stripes. N/C = Not Connected
CK1.2 MASTER[IN] 1. +12VDC IN 2. Data Out 3. Ground 4. N/C 5. RS-232 Receive 6. Ground 7. STATUS IN 8. +12VDC IN
RJ-45's Both Ends 1. White/Orange 2. Orange/White 3. White/Green 4. Blue/White 5. White/Blue 6. Green/White 7. White/Brown 8. Brown/White
CT-610 Zone Control 1. +12V(Extra) 2. Data In 3. Ground(Extra ) 4. N/C 5. RS-232 Xmit 6. Ground 7. Control Out 8. +12V
EIA-568B Pinout
12345678
RJ-45 Jack Pin #'s
12345678
Pair 2 Orange
Pair 1 Blue Pair 3 Green
Pair 4 Brown
S IMPLY B ETTER!
B&K
Page 5
Standard CT610/310/600 System
Keypads connect to the Zone Control Connectors on the CT610/310/600 via CAT 5 cables. A/V components connect via standard audio and video cables to the numbered inputs.
IR Flashers for A/V components are connected to the IR output corresponding to their A/V Input #.
The receiver power amplifiers connect to each Zone speakers via your favorite speaker wire.
S IMPLY B ETTER!
B&K
Page 6
Connecting To A CT610/310/600
Keypads connect to the CT610/310/600 at the Control terminals. There is a set of five terminals for each of the hardware Zones labeled A-F on the CT610/600 and A-C on the CT310. You can terminate the Keypad cables to the Control terminals in one of two ways: 1. If your cables are already terminated in RJ-45 plugs, order the accessory "Terminal Block to RJ-45 Adapter" (P/N 21419) separately from B & K . Plug the RJ-45 plug into the adapter and screw the adapter in place on the CT610/ 310/600. Be sure to match the labels on the back panel to the labels under the pins of the adapter. AND/OR 2. You can strip the keypad cable and terminate five of the wires to the five terminals per Zone. If you are using a CAT 5 cable connected to an RJ-45 at the Keypad, there are extra connections for Ground and 12V. These can be left unterminated (though it does no harm to connect them). It is not important that use any particular color scheme, only that you connect one to one as described here:
CK1.2 Keypad
MASTER[IN] 1. +12VDC IN 2. Data Out 3. Ground 4. N/C 5. RS-232 Receive 6. Ground 7. STATUS IN 8. +12VDC IN ALTERNATE MASTER [IN] 1. +12VDC IN 2. GROUND 3. RS-232 RECIEVE 4. KEYPAD DATA OUT 5. STATUS IN
CT610/310/600
CONTROL ZONE A-F 1. +12VDC IN 2. GROUND 3. RS-232 XMIT 4. DATA IN 5. CTRL OUT
CONTROL ZONE A-F 1. +12VDC IN 2. GROUND 3. RS-232 XMIT 4. DATA IN 5. CTRL OUT
S IMPLY B ETTER!
B&K
Page 7
Keypad Total Power Consumption
The CT610/600 Control 12VDC Outputs can support a Maximum of 26 keypads total. 13 keypads to each vertical array of three zone control connections. Thus, a CT310 can support a maximum of 13 keypads. If you are supplying power to relays, screens or sensors, these must be counted too. Each keypad consumes 75mA.
Fam Rm KP 75 mA Fam Rm Sensor 50 mA Fam Rm Screen relay 200 mA Kitchen KP 75 mA Bedroom KP 75 mA BedroomTV lift 200 mA _______ Total 675 mA Liv Rm KP 75 mA Patio KP 75 mA Den KP 75 mA Den Sensor Total 50 mA _______ 275 mA
Each of the zone/control of the of the CT610/600 are identical to the Each of the zon e/control cardscards CT610 are identical to the single card of the CT310. the CT310. Zone/control card keypad/sensor connectors and 1 card of Zone/Control cards incorporate 3 zone incorporate 3 zone keypad/sencommon control output. The total power consumption of sor connectors and 1 common control output. all devices attac hed conThe total power to one card cannot exceed one amp. sumption of all devices attached to one card cannot exceed one amp.
The B & K PT5 Preamp -- Perfect for Adding Zones
The superb sounding B & K PT5 Preamp incorporates a keypad Control terminal and an IR output for flashers. A simple system would connect like this:
Multiple Flashers are connected in Series for consistent level.
+ Two keypads can be powered by the PT-5 (Master to Slave).
Note: Currently, the CK1.2 keypad does not display input changes made by remote control or the front panel of a PT-5 (only the CT610/310/600 Multi-Zone receivers activate this feature of the CK1.2 keypad).
S IMPLY B ETTER!
B&K
Page 8
Keypads with other B & K Receivers and Preamps
The CK1.2 Keypad can be easily programmed with the commands for all remote controlled B & K receivers and preamps. Because of B & K's elegant all discrete code architecture, the CK1.2 will automate and delight owners of any B & K receiver or preamp. You can simply connect the keypad to any B & K receiver or preamp directly to control just the B & K (with the addition of an inexpensive 12VDC power supply). However, the best way to connect is to utilize an Infared Repeater system to connect your B & K keypads to both your B & K receiver/preamp and your other brand sources and devices. Infrared repeater systems are available from reputable manufacturers like:
Niles Audio Xantech SpeakerCraft www.nilesaudio.com www.xantech.com www.speakercraft.com Audioplex Sonance www.audioplex.com www.sonance.com
These brand and/or product names are trademarks or registered trademarks of their respective companies or organizations.
Infrared Repeaters for Any Brand of Receiver/Preamp
Infrared repeater connecting blocks enable you to use the CK1.2 with any brand of infrared remote controlled receiver or preamp. However, infrared repeaters do not support RS232 communications, so a change in source made via the receiver's original remote control will not update the screen of the CK1.2 the way it does when connected to a B & K CT610/600 or CT310. Thus, in systems like this, the best advice is to always use the keypad to change sources, not the remote control to keep things "in sync". All Infrared repeaters incorporate three conductors that connect to the CK1.2 keypad. These connect as follows. IR REPEATER 1. IR DATA 2. Ground 3. 12VDC+ ALTERNATE MASTER [IN] 4. KEYPAD DATA OUT 2. GROUND 1. +12VDC IN
Repeaters are typically shipped with a power supply of about 500ma. Should your system require more than five keypads purchase a larger 912vDC unregulated power supply. Audioplex and Xantech infrared repeater connecting blocks incorporate an additional feature: A jack that enables a fourth conductor to send 12VDC status when the preamp/receiver is on. This requires that your preamp/receiver have a the switched outlet on the rear. If it does, you simply plug a 12VDC power supply in the outlet and connect to the status inpu ...