9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your DCS DD-224PH : user manual, user guide, instruction manual.
Search a brand
Advanced Search

Need help using a product?
Look at the reviews on DCS DD-224PH

User manual DCS DD-224PH - INSTALLATION INSTRUCTION

Diplodocs help download the user guide DCS DD-224PH - INSTALLATION INSTRUCTION .

Download the complete user guide (2007 Ko)




You may also download the following manuals related to this product:
DCS DD-224PH


Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide DCS DD-224PH - INSTALLATION INSTRUCTION

Detailed instructions for use are in the User's Guide.

US CA part number 528247 B master 526607 N 05/2005 (page 1 of 12) R INSTALLATION INSTRUCTIONS DOUBLE DD224 SERIES MODELS SINGLE DD124 SERIES MODELS NOTE TO THE INSTALLER 1. Read these instructions completely and carefully. 2. Installation of this DishDrawer® requires basic mechanical and electrical skills. 3. Be sure to leave these Instructions with the Customer. 4. At the completion of the DishDrawer® installation, the Installer must perform Final Check List as per Section 11 of these Installation Instructions. 5. Remove all packaging materials supplied with the DishDrawer®. 6. This dishwasher is manufactured for indoor use only. WARNING! Before installing the DishDrawer® , remove the house fuse or open the circuit breaker. Ensure all water connections are turned OFF. It is the responsibility of the plumber and electrician to ensure that each installation complies with all Codes and Regulations. Important! These instructions must be followed precisely to ensure correct venting and operation of the DishDrawer®. In the event of a fault related to the incorrect installation, the installer will be liable for any repairs. Important! The DishDrawer® MUST be installed to allow for future removal from the enclosure if service is required. Important! NOTE TO THE CUSTOMER Keep these Installation Instructions with your Use & Care for future reference. DishDrawer® must be securely anchored before it is operated. Improper installation is not covered under the Warranty. Important! If the DishDrawer® is to be relocated from one installation to another it must be kept upright to avoid damage from water spillage. R BEFORE YOU START - DOUBLE & SINGLE MODELS PARTS SUPPLIED DOUBLE MODELS SINGLE MODELS Wire Clip (1) Installation Tabs (2) Drain Hose Support (1) Washer (1) Wire Clips (2) Phillips 16mm Screws (7) Moisture Protection Tape (1) p/n 527208 Edge Protector (1) Phillips 16mm Screws (5) Moisture Protection Tape (1) p/n 527208 Washer (1) Flexible Extrusion for Sides (2) Edge Protector (1) Flexible Extrusion for Top (1) Clamp (1) Drain Hose Joiner (1) Clamp (1) Drain Hose Support (1) Drain Hose Joiner (1) Flexible Extrusion for Sides (2) TOOLS NEEDED Wooden Chopping Board Tape Measure Spirit Level Safety Glasses Utility Knife Pencil Sandpaper Drill & No.2 Phillips Bit No.2 Phillips Screwdriver Flat Screwdriver Adjustable Wrench or M5 Socket Ø11/2" (38mm) Hole Saw Side Cutting Pliers Prefinished Toe Kick (1) White prefinished toe kick kit p/n 526678 or Black prefinished toe kick kit p/n 526679 or Iridium prefinished toe kick kit p/n 527109 SPARE PARTS INSTALLATION KIT FOR SINGLE & DOUBLE MODELS: p/n 526676 INSTALLATION PREPARATION ELECTRICAL PREPARATION A) The switched power outlet must be outside the DishDrawer® cavity so that it is accessible after installation. B) The switched power outlet must be between 6" (150mm) and 18" (450mm) from the DishDrawer® cavity. C) Refer to Page 9, Step 5 for electrical connection options. CAVITY PREPARATION A) It is recommended that all cabinetry surrounding the DishDrawer® (including the underside of the countertop) is sealed with an oil based paint or moisture-proof polyurethane to prevent possible steam damage. The air in the cavity can get very hot and humid (saturated at 122oF/50oC) B) The self-adhesive moisture protection tape must be applied to the underside of the countertop to prevent moisture damage, (refer to cavity diagram pg 3 or 5). Be sure surfaces are dry and dust-free prior to application. C) Be sure the cavity provides sufficient material to secure the DishDrawer® using the mounting tabs (refer to step 1, page 7). If there is nothing to screw to, add a brace. See page 3 or 5 for screw locations. D) The services hole MUST be immediately adjacent to the rear lower corner of the cabinetry. If not, the hoses will prevent the DishDrawer® being pushed back into the cavity all the way. The hole can be located on either side depending on the location of the services. E) Be sure the cavity sides are plumb (vertical) as this will assist with levelling the DishDrawer® . F) Minimum clearances: Important! The services hole in the DishDrawer® cavity needs to be large enough for the plug on the power supply cord to fit through, but MUST NOT be more than 11/2" (38mm). PLUMBING & DRAINAGE PREPARATION A) A readily accessible valve must be installed in the water supply pipe. B) If the supply pressure exceeds 145 psi (1000kPa), then a pressure limiting valve must be used. C) Review Plumbing Options on pages 4 & 6. Choose a method that best suits your needs. D) A Drain Hose extension Kit P/N 525798 will extend the drain hoses by 1413/4" (3.6m). The kit is available from the nearest Fisher&Paykel Authorized Service Agent. DO NOT extend beyond this limit. E) This Dishwasher's maximum drain height is 371/2" (950mm). 1/8" (2.5mm) 1/8" (2.5mm) 1/2" (13mm) ELECTRICAL INFORMATION POWER SUPPLY CORD A) Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to the power supply cord. B) If the power supply cord is damaged, it must be replaced by the Manufacturer, Service Agent or a similarly qualified person in order to avoid a hazard. WARNING! Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt as to whether the appliance is properly grounded. B) This appliance is equipped with a power supply cord having an equipment-grounding conductor and an earthing plug. The power supply plug must be plugged into an appropriate outlet that is installed and earthed in accordance with all local Codes and Ordinances. GROUNDING INSTRUCTIONS A) This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. WARNING! Do not modify the power supply plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Do not use an extension cord, adaptor plug or multiple 2 R DOUBLE MODELS SERVICES SPECIFICATIONS * WATER CONNECTION Recommended HOT (Maximum 140°F/60°C). Supplied hose to suit 3/8" male compression fitting. WATER SOFTENER MODELS Refer to your User Guide for how to set up your water softener. R WATER PRESSURE Water Softener Models Other Models Maximum 145 p.s.i. (1000kPa) 145 p.s.i. (1000kPa) Minimum 14.5 p.s.i. (100kPa) 4.3 p.s.i. (30kPa) * Depth of product excludes Curvature 3/8" (10mm) and Handle. DRAIN CONNECTION Drain Hose Joiner to suit Ø3/4" ± 5/64", Ø5/8" ± 5/64" and Ø1" ± 5/64" waste tees. LENGTH OF SERVICES (FROM PRODUCT EXIT POINT) Drain hose - 889/16" (2250mm) Inlet hose - 687/8" (1750mm) Power supply cord - 44" (1125mm) NOTE: Services approximately exit product 77/16" (189mm) from left; 215/8" (550mm) from front; 311/4" (793mm) from top. ELECTRICAL CONNECTION 110-120 VAC power outlet, 9 Amps Minimum. THE CAVITY + + These marks indicate mounting tab screw locations (refer to step 1 page 7) NOTE: All depth measurements are taken from the front face of the adjacent cabinetry. WARNING! Be sure the edges of the services hole are smooth or covered. If the services hole is through a metal partition the hole must be protected with the Edge Protector provided to prevent damage to the power cord or hoses. 3 R DOUBLE MODELS PLUMBING OPTIONS OPTION 1 DishDrawer® and Standpipe Ø11/2" (38mm) with Air Gap. (750mm - 882.5mm) 29 1/2" -34 3/4" OPTION 2 DishDrawer® with Waste Disposal. OPTION 3 DishDrawer® using Air Break with Drain Hose Joiner. NOTE: Prefinished Model is shown. There is no variation in plumbing between models. Option 1 is the preferred option. Drains will need to be separated to satisfy Kosher requirements. We suggest you confirm acceptability with your local Rabbi in respect to Kosher installations. 4 MAX height to top of AIR BREAK (countertop or wall-mounted) 37 3/8" (950mm) R SINGLE MODELS SERVICES SPECIFICATIONS * WATER CONNECTION Recommended HOT (Maximum 140°F/60°C). Supplied hose to suit 3/8" male compression fitting. WATER SOFTENER MODELS Refer to your DishDrawer® User Guide for how to set up your water softener. WATER PRESSURE Water Softener Models Other Models Maximum 145 p.s.i. (1000kPa) 145 p.s.i. (1000kPa) Minimum 14.5 p.s.i. (100kPa) 4.3 p.s.i. (30kPa) * Depth of product excludes Curvature 3/8" (10mm) and Handle. DRAIN CONNECTION Drain Hose Joiner to suit Ø3/4" ± 5/64" and Ø5/8" ± 5/64" waste tees. ELECTRICAL CONNECTION 110-120 VAC power outlet, 4.5 Amps Minimum. LENGTH OF SERVICES (FROM PRODUCT EXIT POINT) Drain hose - 889/16" (2250mm) Inlet hose - 687/8" (1750mm) Power supply cord - 44" (1125mm) NOTE: Services approximately exit product 77/16" (189mm) from left; 215/8" (550mm) from front; 151/2" (393mm) from top. WEIGHT Full 107 lb (48kg) Prefinished Empty 76 lb (34kg) Prefinished THE CAVITY + + + + R Important! Adjacent cabinetry must not extend above cavity base. WARNING! These marks indicate mounting screw tab locations (refer to step 1 page 7) NOTE: All depth measurements are taken from the front face of the adjacent cabinetry. NOTE: To align drawer front to adjacent cabinetry, the product to countertop clearance can be increased from 1/8" (3mm). Be sure the edges of the services hole are smooth or covered. If the services hole is through a metal partition the hole must be protected with the Edge Protector provided to prevent damage to the power cord or hoses. 5 R SINGLE MODELS PLUMBING OPTIONS OPTION 1 DishDrawer® and Standpipe Ø11/2" (38mm) with Air Gap. OPTION 2 DishDrawer® with Waste Disposal. OPTION 3 DishDrawer® using Air Break with Drain Hose Joiner. NOTE: Prefinished Model is shown. There is no variation in plumbing between models. Option 1 is the preferred option. Drains will need to be separated to satisfy Kosher requirements. We suggest you confirm acceptability with your local Rabbi in respect to Kosher installations. 6 MAX height to top of AIR BREAK (countertop or wall-mounted) 37 3/8" (950mm) R INSTALLATION INSTRUCTIONS PLEASE NOTE: Your model of DishDrawer® may differ from the model shown in the installation diagrams. Installation is similar for all models for either Single or Double models. Information referring to Single models only is highlighted in blue. Installation diagrams have been simplified to enable clearer instruction. READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY. STEP 1: MOVING THE PRODUCT INTO THE CAVITY MOUNTING TAB OPTIONS The mounting tabs are in pairs, one on each side of the product. They are used to secure the product to the cavity sides. Installation requires two sets of tab pairs be used. DOUBLE MODELS ONLY - A and B tab pairs OR B and C tab pairs may be used. All tabs would be optimum. 2 1 1 2 If the top installation tabs C are to be used, fit to the chassis by inserting into the top slots as shown. Ensure the tabs are fully locked in place. Optional Flexible Extrusion If the cavity is 24" x 341/2" (610mm x 876mm) flexible extrusions can be attached along the top and sides of the product. Open the drawer(s) to expose the chassis trim. Remove extrusion backing and adhere to the side and top of DishDrawer®. Refer to the drawing for correct placement. Be sure that extrusions do not prevent the drawer from closing completely. 3 4 3 4 Check cavity for any obstructions that may interfere with sliding the product back. DOUBLE MODELS ONLY - loosen the feet first. Push product into cavity to suit adjacent cabinetry. Do not push middle of drawer(s). Be sure inlet, drain hose(s) and power supply cord are not restricted or damaged by carefully pulling all excess length through the services hole, while the product is being pushed back into the cavity. FOR SINGLE MODELS, check that the base of the product is not bowed. Do not rest single models on your knee when moving them into the cavity. WARNING! Be careful of sharp edges. Important! DO NOT push middle of drawer(s). STEP 2: REMOVING THE TUB Important! (SINGLE MODELS ONLY). The product may move. Mark chassis position on cavity. 5 5 7 6 SINGLE MODELS ONLY. Gently open the drawer and mark the chassis position on the cavity, before removing the tub. Open the drawer (bottom drawer in DOUBLE MODELS). Release the tub by depressing the right hand tub clip and pushing it back 13/16" (30mm). Repeat on the left hand side. Lift the tub up off the drawer runners. Slide both runners back into the product. Place the tub onto the floor. For SINGLE MODELS, depending on the height of the cavity, the tub will need to be supported, eg on a chair. 6 7 8 9 8 9 7 R INSTALLATION INSTRUCTIONS STEP 3: ADJUSTING THE FEET (DOUBLE MODELS ONLY) 10 DOUBLE MODELS ONLY Adjust the height of the product to suit the cabinetry, by turning the feet from inside the product using a w ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.