9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your YAESU FT-2000 : user manual, user guide, instruction manual.
Search a brand
Advanced Search

Need help using a product?
Look at the reviews on YAESU FT-2000

User manual YAESU FT-2000 - MENU MODE LIST

Diplodocs help download the user guide YAESU FT-2000 - MENU MODE LIST .

Download the complete user guide (406 Ko)




You may also download the following manuals related to this product:
YAESU FT-2000
YAESU FT-2000 BROCHURE
YAESU FT-2000 CAT OPERATION REFERENCE BOOK
YAESU FT-2000 CAT OPERATION REFERENCE BOOK
YAESU FT-2000 INSTALLATION INSTRUCTIONS
YAESU FT-2000 MENU MODE
YAESU FT-2000 TRANSVERTER OUTPUT TERMINAL


Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide YAESU FT-2000 - MENU MODE LIST

Detailed instructions for use are in the User's Guide.

MENU MODE The Menu system of the FT-2000 provides extensive customization capability, so you can set up your transceiver just the way you want to operate it. The Menu items are grouped by general utilization category, and are numbered from "001 AGc 001 DLY" EMRGNCY." FST DLY to "149 tGEn EMRGNCY 149 USING THE MENU 1. Press the [MENU] button momentarily, to engage the Menu mode. The Main (VFO-A) frequency display will show the Menu Number and Menu Group name, while the Sub (VFO-B) frequency display will show the Menu item; the Multi-Display window shows the current setting of the currently-selected Menu item. 2. Rotate the Main Tuning Dial knob to select the Menu item you wish to work on. 3. Rotate the [SUB VFO-B] knob to change the current setting of the selected Menu item. ADVICE: Press the [CLEAR] button momentarily to reset the selected Menu item to the factory default value. 4. When you have finished making your adjustments, press and hold in the [MENU] button for two seconds to save the new setting and exit to normal operation. If you only momentarily press the [MENU] button, the new settings will not be retained. [CLEAR] Button [MENU] Button Main Tuning Dial Knob [SUB VFO-B] Knob Menu Number Menu Group Name Menu Item Menu Setting Menu Mode Reset You may reset all the Menu settings to their original factory defaults, if desired. 1. Turn the front panel [POWER] switch off. 2. Press and hold in the [MENU] button, and while holding it in, press the [POWER] switch to turn the transceiver back on. Now release the [MENU] button. Page 108 FT-2000 OPERATING MANUAL MENU MODE GROUP AGC AGC AGC AGC AGC AGC DISPLAY DISPLAY DISPLAY DISPLAY DISPLAY DISPLAY DISPLAY DISPLAY DISPLAY DVS DVS KEYER KEYER KEYER KEYER KEYER KEYER KEYER KEYER GENERAL GENERAL GENERAL GENERAL GENERAL GENERAL GENERAL GENERAL GENERAL GENERAL GENERAL GENERAL GENERAL GENERAL GENERAL GENERAL GENERAL GENERAL S IF SFT S IF SFT S IF SFT S IF SFT S IF SFT S IF SFT S IF SFT S IF SFT MODE-AM MODE-AM NO. 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031 032 033 034 035 036 037 038 039 040 041 042 043 044 045 046 047 048 049 050 051 052 053 MENU FUNCTION AGc FST DLY AGc FST HLD AGc MID DLY AGc MID HLD AGc SLW DLY AGc SLW HLD diSP COLOR diSP DIM MTR diSP DIM VFD diSP BAR SEL diSP PK HLD diSP RTR STU diSP RTR ADJ diSP QMB MKR diSP LVL IND dUS RX LVL dUS TX LVL tEy BEACON tEy NUM STL tEy CONTEST tEy CW MEM1 tEy CW MEM2 tEy CW MEM3 tEy CW MEM4 tEy CW MEM5 GEnE ANT SEL GEnE BEP LVL GEnE CAT BPS GEnE CAT TOT GEnE CAT RTS GEnE CAT IND GEnE MEM GRP GEnE Q SPLIT GEnE TRACK GEnE TX TOT GEnE TRV SET GEnE T DIAL GEnE SNB LVL GEnE SUB FIL GEnE MIC SCN GEnE SCN RSM GEnE ANTIVOX GEnE FRQ ADJ S-iF LSB SFT S-iF USB SFT S-iF CWL SFT S-iF CWU SFT S-iF RTTY S-iF RTTY-R S-iF PKT-LSB S-iF PKT-USB A3E MICGAIN A3E MIC SEL AVAILABLE VALUES 20 ~ 4000 msec (20 msec/step) 0 ~ 2000 msec (20 msec/step) 20 ~ 4000 msec (20 msec/step) 0 ~ 2000 msec (20 msec/step) 20 ~ 4000 msec (20 msec/step) 0 ~ 2000 msec (20 msec/step) bL1 / bL2 / bL3 / ub1 / ub2 0 ~ 15 0~7 CLAr / C-tn / u-tn OFF / 0.5 / 1.0 / 2.0 sec 0 / 90 / 180 / 270° ­30° ~ 0° (2°/step) On / OFF PI / SP / CO / nO / dn / Cd / Ud / rP / nG / Pr / SH / UI 0 ~ 100 0 ~ 100 OFF / 1 ~ 255 sec 1290 / AunO / Aunt / A2nO / A2nt / 12nO / 12nt 1 ~ 9999 tyP1 / tyP2 tyP1 / tyP2 tyP1 / tyP2 tyP1 / tyP2 tyP1 / tyP2 bAnd / rEG 0 ~ 100 4800 / 9600 / 192H (19200) / 384H (38400) bps 10 / 100 / 1000 / 3000 msec On / OFF On / OFF On / OFF ­20 ~ 0 ~ +20 kHz (1 kHz/step) OFF / bAnd / FrEq OFF / 3 / 5 / 10 / 15 / 20 / 30 min 30 ~ 49 MHz StP1 / StP2 / OFF nAin (MAIN) / 0~100 1200 / 500 / 300 Hz On / OFF CAr / 5Sec 0 ~ 100 ­25 ~ 0 ~ +25 ­1000 ~ +1000 Hz (20 Hz/step) ­1000 ~ +1000 Hz (20 Hz/step) ­1000 ~ +1000 Hz (20 Hz/step) ­1000 ~ +1000 Hz (20 Hz/step) ­1000 ~ +1000 Hz (20 Hz/step) ­1000 ~ +1000 Hz (20 Hz/step) ­1000 ~ +1000 Hz (20 Hz/step) ­1000 ~ +1000 Hz (20 Hz/step) Ur (VR) / 0 ~ 100 Frnt / dAtA / PC DEFAULT SETTING 300 msec 20 msec 700 msec 20 msec 2000 msec 20 msec bL1 1 7 4 C-tn OFF 0° 0° On 1 ­­ 50 50 OFF 1290 1 tyP2 tyP2 tyP2 tyP2 tyP2 2 bAnd 50 4800 bps 10 msec On On OFF +5 kHz OFF OFF 44 MHz StP1 nAin(MAIN) 1200 Hz On 5SEc 50 0 0 Hz 0 Hz 0 Hz 0 Hz 0 Hz 0 Hz 0 Hz 0 Hz 30 Frnt 1: Requires optional DMU-2000 Data Management Unit. 2: Requires optional FH-2 Remote Control Keypad. FT-2000 OPERATING MANUAL Page 109 MENU MODE GROUP MODE-CW MODE-CW MODE-CW MODE-CW MODE-CW MODE-CW MODE-CW MODE-CW MODE-CW MODE-CW MODE-CW MODE-CW MODE-DAT MODE-DAT MODE-DAT MODE-DAT MODE-DAT MODE-DAT MODE-DAT MODE-DAT MODE-FM MODE-FM MODE-FM MODE-FM MODE-RTY MODE-RTY MODE-RTY MODE-RTY MODE-RTY MODE-RTY MODE-SSB MODE-SSB MODE-SSB MODE-SSB MODE-SSB MODE-SSB RX AUDIO RX AUDIO RX DSP RX DSP RX DSP RX DSP RX DSP RX DSP RX DSP RX DSP RX DSP RX DSP RX DSP RX DSP RX DSP RX DSP RX DSP NO. 054 055 056 057 058 059 060 061 062 063 064 065 066 067 068 069 070 071 072 073 074 075 076 077 078 079 080 081 082 083 084 085 086 087 088 089 090 091 092 093 094 095 096 097 098 099 100 101 102 103 104 105 106 MENU FUNCTION A1A F-TYPE A1A F-REV A1A R-TYPE A1A R-REV A1A CW AUTO A1A BFO A1A BK-IN A1A SHAPE A1A WEIGHT A1A FRQDISP A1A PC KYNG A1A QSKTIME dAtA DATA IN dAtA DT GAIN dAtA DT OUT dAtA OUT LVL dAtA VOX DLY dAtA V GAIN dAtA PKTDISP dAtA PKT SFT F3E MICGAIN F3E MIC SEL F3E 28 RPT F3E 50 RPT rtty R PLRTY rtty T PLRTY rtty RTY OUT rtty OUT LEL rtty SHIFT rtty TONE J3E MIC SEL J3E TX BPF J3E LSB CAR J3E USB CAR J3E SLSB CR J3E SUSB CR rout AGC SLP rout HEADPHN rdSP CNTR LV rdSP CNTR WI rdSP NOTCH W rdSP CW SHAP rdSP CW SLP rdSP CW NARR rdSP PKT SHP rdSP PKT SLP rdSP PKT NAR rdSP RTY SHP rdSP RTY SLP rdSP RTY NAR rdSP SSB SHP rdSP SSB SLP rdSP SSB NAR AVAILABLE VALUES OFF / buG / ELE / ACS nor / rEU (REV) OFF / buG / ELE / ACS nor / rEU (REV) OFF / 50 / On USb / LSb / Auto SEni (SEMI) / FuLL 1 / 2 / 4 / 6 msec (1:) 2.5 ~ 4.5 dir / OFSt EnA (Enable) / diS (Disable) 15 / 20 / 25 / 30 msec dAtA / PC 0 ~ 100 nAin (Main) / Sub 0 ~ 100 30 ~ 3000 msec 0 ~ 100 ­3000 ~ +3000 Hz (10 Hz/step) ­3000 ~ +3000 Hz (10 Hz/step) Ur (VR) / 0 ~ 100 Frnt / dAtA / PC 0 ~ 1000 kHz (10 kHz/step) 0 ~ 4000 kHz (10 kHz/step) nor / rEU (REV) nor / rEU (REV) nAin (Main) / Sub 0 ~ 100 170 / 200 / 425 / 850 Hz 1275 / 2125 Hz Frnt / dAtA / PC 1-30 / 1-29 / 2-28 / 3-27 / 4-26 / 3000 ­200 Hz ~ +200 Hz (10 Hz/step) ­200 Hz ~ +200 Hz (10 Hz/step) ­200 Hz ~ +200 Hz (10 Hz/step) ­200 Hz ~ +200 Hz (10 Hz/step) nor / SLP SEP / Con1 / Con2 ­40 ~ +20 dB 1 ­ 11 nArr (Narrow) / uuid (Wide) SOFt / ShAP StP(STEEP) / nEd(MEDIUM) / GEnt(GENTLE) 25 / 50 / 100 / 200 / 300 / 400 / 500 / 800 / 1200 / 1400 / 1700 / 2000 Hz SOFt / ShAP StP(STEEP) / nEd(MEDIUM) / GEnt(GENTLE) 25 / 50 / 100 / 200 / 300 / 400 Hz SOFt / ShAP StP(STEEP) / nEd(MEDIUM) / GEnt(GENTLE) 25 / 50 / 100 / 200 / 300 / 400 Hz SOFt / ShAP StP(STEEP) / nEd(MEDIUM) / GEnt(GENTLE) 200 / 400 / 600 / 850 / 1100 / 1350 / 1500 / 1650 / 1800 / 1950 / 2100 / 2250 Hz DEFAULT SETTING ELE nor ELE nor OFF USb SEni (SEMI) 4 msec 3.0 OFSt diS (Disable) 15 msec dAtA 50 nAin (Main) 50 300 msec 50 0 Hz 1000 Hz 50 Frnt 100 kHz 1000 kHz nor nor nAin (Main) 50 170 Hz 2125 Hz Frnt 3-27 0 Hz 0 Hz 0 Hz 0 Hz nor SEP ­15 dB 10 uuid (Wide) ShAP nEd (MEDIUM) 500 Hz ShAP nEd (MEDIUM) 300 Hz ShAP nEd (MEDIUM) 300 Hz ShAP nEd (MEDIUM) 1800 Hz Page 110 FT-2000 OPERATING MANUAL MENU MODE GROUP SCOPE SCOPE SCOPE SCOPE SCOPE SCOPE SCOPE SCOPE SCOPE SCOPE SCOPE TUNING TUNING TUNING TUNING TUNING TUNING TUNING TX AUDIO TX AUDIO TX AUDIO TX AUDIO TX AUDIO TX AUDIO TX AUDIO TX AUDIO TX AUDIO TX AUDIO TX AUDIO TX AUDIO TX AUDIO TX AUDIO TX AUDIO TX AUDIO TX AUDIO TX AUDIO TX GNRL TX GNRL TX GNRL TX GNRL TX GNRL TX GNRL TX GNRL NO. 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 MENU FUNCTION SCP 1.8 FIX SCP 3.5 FIX SCP 5.0 FIX SCP 7.0 FIX SCP 10.1 FIX SCP 14.0 FIX SCP 18.0 FIX SCP 21.0 FIX SCP 24.8 FIX SCP 28.0 FIX SCP 50.0 FIX tun DIALSTEP tun CW FINE tun MHz SEL tun AM STEP tun FM STEP tun FM DIAL tun MY BAND tAUd EQ1 FRQ tAUd EQ1 LVL tAUd EQ1 BW tAUd EQ2 FRQ tAUd EQ2 LVL tAUd EQ2 BW tAUd EQ3 FRQ tAUd EQ3 LVL tAUd EQ3 BW tAUd PE1 FRQ tAUd PE1 LVL tAUd PE1 BW tAUd PE2 FRQ tAUd PE2 LVL tAUd PE2 BW tAUd PE3 FRQ tAUd PE3 LVL tAUd PE3 BW tGEn BIAS tGEn MAX PWR tGEn PWRCTRL tGEn ETX-GND tGEn TUN PWR tGEn VOX SEL tGEn EMRGNCY AVAILABLE VALUES 1.800 - 1.999 MHz (1 kHz/step) 3.500 - 3.999 MHz (1 kHz/step) 5.250 - 5.499 MHz (1 kHz/step) 7.000 - 7.299 MHz (1 kHz/step) (1)0.100 - (1)0.149 MHz (1 kHz/step) (1)4.000 - (1)4.349 MHz (1 kHz/step) (1)8.000 - (1)8.199 MHz (1 kHz/step) (2)1.000 - (2)1.449 MHz (1 kHz/step) (2)4.800 - (2)4.989 MHz (1 kHz/step) (2)8.000 - (2)9.699 MHz (1 kHz/step) (5)0.000 - (5)3.999 MHz (1 kHz/step) 1 / 5 / 10 Hz EnA / diS 1 / 0.1 MHz 2.5 / 5 / 9 / 10 / 12.5 kHz 5 / 6.25 / 10 / 12.5 / 20 / 25 kHz 10 / 100 Hz 1.8 ~ 50 / GE / AU OFF / 100 ~ 700 Hz (100 Hz/step) ­20 ~ +10 1 ~ 10 OFF / 700 ~ 1500 Hz (100 Hz/step) ­20 ~ +10 1 ~ 10 OFF / 1500 ~ 3200 Hz (100 Hz/step) ­20 ~ +10 1 ~ 10 OFF / 100 ~ 700 Hz (100 Hz/step) ­20 ~ +10 1 ~ 10 OFF / 700 ~ 1500 Hz (100 Hz/step) ­20 ~ +10 1 ~ 10 OFF / 1500 ~ 3200 Hz (100 Hz/step) ­20 ~ +10 1 ~ 10 ­­ 10 / 20 / 50 / 100 W ALL / Car EnA (ENABLE) / diS (DISABLE) 10 / 20 / 50 / 100 W nic (MIC) / dAtA EnA (ENABLE) / diS (DISABLE) DEFAULT SETTING 1.800 MHz 1 3.500 MHz 1 5.250 MHz 1 7.000 MHz 1 (1)0.100 MHz 1 (1)4.000 MHz 1 (1)8.068 MHz 1 (2)1.000 MHz 1 (2)4.890 MHz 1 (2)8.000 MHz 1 (5)0.000 MHz 1 10 Hz diS 1 MHz 5 kHz 5 kHz 100 Hz ­­ OFF +5 10 OFF +5 10 OFF +5 10 200 Hz 0 2 800 Hz 0 1 2100 Hz 0 1 ­­ 2 100 W ALL diS (DISABLE) 100 W nic (MIC) diS (DISABLE) 1: Requires optional DMU-2000 Data Management Unit. 2: This Menu item does not work. Please do not change this setting. FT-2000 OPERATING MANUAL Page 111 MENU MODE AGC GROUP 001 AGc FST DLY Function: Sets the delay time for the AGC FAST mode of the Main band (VFO-A) receiver. Available Values: 20 ~ 4000 msec (20 msec/step) Default Setting: 300 msec DISPLAY GROUP 007 diSP COLOR Function: Selects the Display color when the optional Data Management Unit (DMU-2000) is connected. Available Values: bL1 / bL2 / bL3 / ub1 / ub2 bL1: COOL BLUE bL2: CONTRAST BLUE bL3: FLASH WHITE ub1: CONTRAST UMBER ub2: UMBER Default Setting: bL1 (COOL BLUE) ADVICE: If the optional DMU-2000 Data Management Unit is not connected, this adjustment has no effect. 002 AGc FST HLD Function: Sets the hang time of the AGC peak voltage for the AGC FAST mode of the Main band (VFO-A) receiver. Available Values: 0 ~ 2000 msec (20 msec/step) Default Setting: 20 msec 003 AGc MID DLY Function: Sets the delay time for the AGC MID mode of the Main band (VFO-A) receiver. Available Values: 20 ~ 4000 msec (20 msec/step) Default Setting: 700 msec 008 diSP DIM MTR Function: Setting of the meter brightness level when "DIM" is selected. Available Values: 0 ~ 15 Default Setting: 7 004 AGc MID HLD Function: Sets the hang time of the AGC peak voltage for the AGC MID mode of the Main band (VFO-A) receiver. Available Values: 0 ~ 2000 msec (20 msec/step) Default Setting: 20 msec 009 diSP DIM VFD Function: Setting of the frequency display brightness level when "DIM" is selected. Available Values: 0 ~ 7 Default Setting: 4 005 AGc SLW DLY Function: Sets the delay time for the AGC SLOW mode of the Main band (VFO-A) receiver. Available Values: 20 ~ 4000 msec (20 msec/step) Default Setting: 2000 msec 010 diSP BAR SEL Function: Selects one of three parameters to be viewed on the Tuning Offset Indicator. Available Values: CLAr / C-tn / u-tn Default Setting: C-tn CLAr: Displays relative clarifier offset. C-tu: Displays relative CW tuning offset between the incoming signal and transmitted frequency. u-tn: Displays the peak position of the VRF or TUNE filter. NOTE: The -TUNE filter is an option. 006 AGc SLW HLD Function: Sets the hang time of the AGC peak voltage for the AGC SLOW mode of the Main band (VFO-A) receiver. Available Values: 0 ~ 2000 msec (20 msec/step) Default Setting: 20 msec 011 diSP PK HLD Function: Selects the peak hold time of the Sub (VFO-B) receiver's S-meter. Available Values: OFF / 0.5 / 1.0 / 2.0 sec Default Setting: OFF 012 diSP RTR STU Function: Selects the starting point of your rotator controller's indicator needle. Available Values: 0 / 90 / 180 / 270° Default Setting: 0° 013 diSP RTR ADJ Function: Adjusts the indicator needle precisely to the starting point set in menu item "012 diSP RTR STU." Available Values: ­30 ~ 0° Default Setting: 0° Page 112 FT-2000 OPERATING MANUAL MENU MODE DISPLAY GROUP 014 diSP QMB MKR Function: Enables/Disables the QMB Marker (White arrow " ") to display on the Spectrum Band Scope when the optional DMU-2000 Data Management Unit is connected. Available Values: On / OFF Default Setting: On ADVICE: If the optional D ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.