9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your FOSTEX PD606 : user manual, user guide, instruction manual.
Search a brand
Advanced Search

Need help using a product?
Look at the reviews on FOSTEX PD606

User manual FOSTEX PD606 - OWNERS MANUAL VERSION V1.10 SUPPLEMENT

Diplodocs help download the user guide FOSTEX PD606 - OWNERS MANUAL VERSION V1.10 SUPPLEMENT .

Download the complete user guide (158 Ko)




You may also download the following manuals related to this product:
FOSTEX PD606
FOSTEX PD606 BROCHURE
FOSTEX PD606 OWNERS MANUAL VERSION V1.03 SUPPLEMENT
FOSTEX PD606 V1.03 SUPPLEMENT
FOSTEX PD606 V1.30 SUPPLEMENT


Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide FOSTEX PD606 - OWNERS MANUAL VERSION V1.10 SUPPLEMENT

Detailed instructions for use are in the User's Guide.

8289643000 (478776) Model PD606 Owner's Manual With the software upgrade to V1.10, the PD606 now supports ES bus. Accordingly, the "RS422 SETUP" menu in the MENU mode is now available, while the "Default file name" item in the SYS SETUP menu of the MENU mode has been expanded. In addition, the new version provides the interpolation facility for the internal TC generator in the Free Run mode, as well as you can now cancel post recording. Note that this document only describes the functions upgraded with version 1.10, therefore, please read it together with the original and supplementary manuals. 1 Table of contents Default file name menu item ............................................................................................3 Accessing the "Add Machine ID" item ....................................................................................3 Setting item details ....................................................................................................................3 RS422 SETUP menu .........................................................................................................4 Accessing the RS422 menu ......................................................................................................4 Setting item details ....................................................................................................................4 ES master/slave control function ...................................................................................6 Displays of the ES master and ES slave ...................................................................................6 Commands issued from the master unit to the slave unit(s) ..............................................6 Applications ...............................................................................................................................8 1. Simultaneous recording ............................................................................................8 2. Simultaneous playback (normal song playback) ..................................................9 3. Editing a file name ...................................................................................................10 4. False Start ..................................................................................................................10 Interpolation of the internal TC generator ....................................................................10 Post recording cancel function .....................................................................................10 2 Default file name menu item In the "Default file name" menu item in the SYS SETUP menu of the MENU mode, the "Add Machine ID" item has been newly added. Because the PD606 V1.10 supports ES bus, you can connect multiple PD606 units (or the PD606 with PD204 or DV824) in the ES bus system. When you start recording of multiple machines in the ES bus system, this item prevents creating an audio file with the same name on each unit. By setting this item to "On", a device ID is automatically added before the file extension of each file name. So even if you make recording of multiple units simultaneously, a unique file name is given to each audio file. While the unit is stopped, press the [SHIFT] key followed by the [ENTER/YES] key to enter the MENU mode. Highlight "SYS SETUP" and press the [ENTER/YES] key to bring up the SYS SETUP menu screen. Highlight "Default file name" and press the [ENTER/YES] key to bring up the Default file name setting screen as shown below. You can see the newly added "Add Machine ID" item. (Note that, in the original owner's manual, the screen before the version upgrade is shown.) Added · File name mode By pressing the [ENTER/YES] key while "File name mode: ***" is highlighted, the currently selected file name mode starts flashing and you can now select the desired mode from the following using the [MENU] dial. Date Take Reel The internal realtime clock data is given as the file name. "+" is given to as file name. "+ " is given as the file name. * See page 140 of the original manual for details. · Add Machine ID (newly added item) Selects whether or not adding the ES Device ID (which is set by the "RS422 SETUP" menu of the MENU mode) to a file name. By highlighting "Add Machine ID: **" and pressing the [ENTER/YES] key, the currently selected setting starts flashing and you can now make on/off setting (the default is "Off"). When you set it to "On", the device ID is added to the file name and displayed on the Home screen (see the next page). The setting is stored to the Flash ROM. · SCENE NAME By highlighting "SCENE NAME:" and pressing the [ENTER/YES] key, you can enter a scene name using the numeric keys, [MENU] dial or a USB keyboard. The length of a scene name must be within 17 characters. See page 140 of the original manual for details about how to edit a name. · TAKE NUMBER By pressing the [ENTER/YES] key after entering a scene name, you can enter a take number using the numeric keys, [MENU] dial or a USB keyboard. By default, the take number is "001". A take number is used as a part of a file name when the file name mode is set to "Take", as well as used as take data of meta data in any file name modes. When new recording is made, the number increases by one. See page 140 of the original manual for details. 3 RS422 SETUP menu With the software upgrade to V1.10, the PD606 now supports ES bus and the "RS422 SETUP" menu in the MENU mode is available. You can record or play back multiple PD606 units (or the PD606 with PD204 or DV824) simultaneously via the RS422 connection. In the RS422 SETUP menu, you can set three items: "RS422 Mode", "Device type" and "ES Device ID". Master Word clock Slave 6 5 PARALLEL 9P-REMOTE 4 3 ANALOG IN 2 1 ADJUST 6 5 PARALLEL 9P-REMOTE 4 3 ANALOG IN 2 1 ADJUST WORD OUT DIGITAL I/O (AUTO INPUT SELECT) AUTO SEL WORD/ VIDEO IN TIME CODE IN OUT DIGITAL I/O (AUTO INPUT SELECT) WORD OUT AUTO SEL WORD/ VIDEO IN TIME CODE IN OUT ON OFF ON OFF RS422 cable * In the ES-bus connection, it is recommended to provide the word clock from the master unit to the slave unit(s) in addition to the RS422 cable connection. While the unit is stopped, press the [SHIFT] key followed by the [ENTER/YES] key to enter the MENU mode. Select the "RS422 SETUP" menu and press the [ENTER/YES] key to bring up the RS422 setup screen. · RS422 Mode This item selects the control mode via the RS422 port. By pressing the [ENTER/YES] key while "RS422 Mode: ***" is highlighted, the currently selected RS422 mode starts flashing and you can now select the desired mode. Use the [MENU] dial to select the desired mode and press the [ENTER/YES] key to confirm your selection. Flashing You can select from the following modes. P2-Remote (default) Local ES-Slave ES-Master The unit acts as a controlled device of Sony P2 protocol. You can also control the unit via the panel key operation. Refer to of next page. The unit only can be controlled via the panel key operation. The RS422 is ignored. ES-bus + Fostex Exclusive Slave. The unit acts as a slave device of the ES bus. You can also control the unit via the panel key operation. ES-bus + Fostex Exclusive Master. The unit acts as a master device of the ES bus. It can arm or disarm tracks of all devices (including all ES slaves). (*) To disable the PD606 panel keys, set the [PANEL LOCK] switch on the top panel to "LOCK". 4 · When the RS422 mode is set to ES-Master and the unit is stopped, "-ES MASTER-" is shown in the file name display area on the Home screen. (Note that, however, when the unit is in pause or record mode, the file name is shown normally.) · The "P2-Remote" mode conforms to the Sony P2 protocol but does not support external editors. You can execute only basic controls between PD606 units (or PD204 or DV824) or from a PC. · Device Type Sets the device type of the PD606. By highlighting "Device type: ***" and pressing the [ENTER/YES] key, the currently selected device type starts flashing and you can now select the desired type. Use the [MENU] dial to select the type and press the [ENTER/YES] key to confirm your selection. Flashing You can set the device type to "DVD" (default) or "BVW75". DVD (default) BVW-75 The device type is set to the PD606. The device type is set to BVW-75. · ES Device ID When you connect multiple PD606 units on the ES-bus system, you must set unique device ID to each PD606. By highlighting "ES Device ID: **" and pressing the [ENTER/YES] key, the currently selected device ID starts flashing and you can now select the desired ID. Use the [MENU] dial to select the ID and press the [ENTER/YES] key to confirm your selection. Flashing You can set the device ID to any number between 01 and 99. By setting the newly added "Add Machine ID" item in the default file name screen (described on page 3 in this supplementary manual) to "On", the device ID you set here is reflected to the file name shown on the Home screen (see the screen examples below). A Home screen example when the ES Device ID is set to "01" A Home screen example when the ES Device ID is set to "03" · For the purposes of identification, it is recommended that each master or slave device controlled via ES-bus should have a unique device ID. · To add a device ID to each file name when you control master and slave units via ES-bus, you must set the "Add Machine ID" item in the "Default file name" setting screen for the master unit to "On". 5 ES master/slave control function The ES master/slave control function allows making simultaneous recording/playback of all slave PD606 units from a master PD606. In order to make it possible, all ES master and slave units must receive the same word clock or video sync clock and lock to the sync signal (or all slave units must lock to the word clock from the master unit). If they are not locking to the same clock, the master and slave units may run out of sync. The PD606 guarantees that the deviation between master and slave units is within 1 ppm. : In the ES-bus connection, one-master, one-slave configuration is ideal. However, you can connect multiple (two or three) slave units without any malfunction. Displays of the ES master and ES slave ES master: When the unit is assigned to the ES master and stopped, "-ES MASTER-" is shown in the file name display area on the Home screen. Note that, when the unit is in pause or record mode, the next file name (or the currently recorded file name) is shown. ES slave: When the unit is assigned to an ES slave and configured in the ES bus system, "-ES GRP SELECTED-" is shown in the file name display area on the Home screen. Commands issued from the master unit to the slave unit(s) PLAY key STOP key "Instant Play" command All ES master and ES slave units start playback from the same address at the same timing. "Stop" and "Set Song Position" or "Instant Locate" commands In stop or pause mode: "Bus Select" and "Standby ON" commands The ES master issues the Bus select command and all slave units are bus-connected via the Sony P2 protocol and enter the pause mode. In any modes except in stop and pause modes: "Stop" and "Set Song Position" or "Instant Locate" commands PAUSE key ABS 0 LOCATE ABS END LOCATE "Instant Locate" command "Instant Locate" command 6 REC key "Set New File Name" and "Instant Rec" commands The ES master unit sends the same file name or the file name with each ES device ID to each ES slave units. "Set LTC Start Position" command Immediately after recording starts, the ES master unit sends the same LTC start position to all ES slave units. CUE key LOCATE key "Instant Locate" command (CUE search) The key operation is only effective during playback. "Instant Locate" command "False Start" command The ES slave units execute False start with the same false start mode as the ES master unit. "Load Song File" command (File Skip) "Instant Locate" command (CUE Skip) The key operation is only effective during playback. "Bus Select" and "Load Song File" commands The audio file in the ES master is selected, and before loading the file, all ES slave units are "Bus Select"ed and ES bus-connected via the Sony P2 protocol. Then the command for loading the same audio file name is issued to ES slave units and each unit loads the file. In this procedure, the "{Machine ID}" is converted to "**" (wild card) so a file with the same name but with a different ID is also loaded. If a file with the same file name does not exist in a slave unit, the ES-bus connection returns to the idle condition and the unit cannot receive commands from the ES master until it receives another Bus select command. "STOP" command ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.