9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your PARADOX SPECTRA SP6000 : user manual, user guide, instruction manual.
Search a brand
Advanced Search

User manual PARADOX SPECTRA SP6000 - PROGRAMMING GUIDE

Diplodocs help download the user guide PARADOX SPECTRA SP6000 - PROGRAMMING GUIDE .

Download the complete user guide (2191 Ko)




You may also download the following manuals related to this product:
PARADOX SPECTRA SP6000
PARADOX SPECTRA SP6000 INSTALLATION GUIDE


Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide PARADOX SPECTRA SP6000 - PROGRAMMING GUIDE

Detailed instructions for use are in the User's Guide.

32-Zone Wireless Transceiver Security Systems MG5000 V3.2 MG5050 V3.2 5- to 32-Zone Expandable Security Systems SP5500 V3.2 SP6000 V3.2 SP7000 V3.2 Always Armed, Never Disarmed Programming Guide PARADOX.COM MG5000 PCB Layout Used for In-Field Firmware upgrade through a 307USB Direct Connect Interface. See Connecting to WinLoad on page 62 for details. EBUS and Dialer used with: VDMP3 plug-in voice module for voice reporting PCS100 GSM communicator module Antennas Press and hold the RESET button for five seconds. The STATUS LED will start flashing. Within 2 seconds of this flashing, press the reset switch again. The panel will reset to default and restart. Four pin connector can be used for quick installation of a keypad. Charge LED: Charging and Battery test LED "STATUS" LED: Flash once every second = Normal Flashes ON 1 second and OFF 1 second = Any trouble Always ON = Panel is using phone line Fast flash 6 seconds after power up = Installer lock enabled "RX" & "TX" LED: Flashes quickly when receiving or transmitting RF signals from wireless devices. Do not cut, bend or alter the antennas and ensure that electrical wires do not cross over the antennae, as this may affect signal reception. Paradox Memory Key (PMC-4 PMC-5) Disconnect telephone line before servicing. Refer to AC Power & Backup Battery Connections on page 61. The "BELL" output will shutdown if the current exceeds 3A. Refer to Single Zone Inputs on page 59 Cold water pipe grounding Connection for Self-Contained Bell/Siren The sum of the current drawn from the BELL and AUX must be limited to 1.3A (40VA transformer strongly recommended). Exceeding this limit will overload the panel power supply and lead to complete system shutdown. AWG#14 single conductor solid copper wire Ground clamp To provide maximum lightning protection we strongly recommend having separate earth connections for the dialer and zone ground terminals. To metallic enclosure Max. amount of keypads = 15 keypads Max. aux. current = 700 mA Max. distance of keypad from panel = 76m (250 feet) Max. total run of wire = 230m (750 feet) AUX Power Refer to transformer requirements on page 61 for Aux. Power Output. To connect additional wiring to auxiliary power, use the red (+) and black (-) keypad connectors. Auxiliary power will shut down if current exceeds 1.1A. If the auxiliary output is overloaded and is shut down, you must disconnect all loads from the output for at least 10 seconds before reconnecting any load back to the auxiliary output. * If EOL is enabled: see section [706] option [2]. For the keypad's zone configurations, refer to Installer Quick Menu on page 65. Also refer to keypad zone connections on page 59. For the keypad's zone configurations, refer to the Installer Quick Menu. If EOL is enabled: see section [706] option [2]. Also refer to Keypad Zone Connections on page 59. This equipment must be installed and maintained by qualified service personnel only. For UL and C-UL warnings, refer to the UL and C-UL Warnings section at the back of the Reference & Installation Manual. 1 Programming Guide MG5050 PCB Layout LEDs Charge LED: Charging and battery test LED Status LED: · Flash once every second = Normal · Flashes ON 1 second and OFF 1 second = Any trouble · Always ON = Panel is using phone line · Fast flash 6 seconds after power up = Installer lock enabled "RX" & "TX" LED: Flashes quickly when receiving or transmitting RF signals from wireless devices. Do not cut, bend or alter the antennas and ensure that electrical wires do not cross over the antennae, as this may affect signal reception. Antennas Paradox Memory Key (PMC-4, PMC-5) J3 and J4 used with: VDMP3 plug-in voice module for voice reporting PCS100 GSM communicator module Used for In-Field Firmware upgrade through a 307USB Direct Connect Interface. See Connecting to WinLoad on page 62 for details. Press and hold the RESET button for five seconds. The STATUS LED will start flashing. Within 2 seconds of this flashing, press the reset switch again. The panel will reset to default and restart. Four pin connector can be used for quick installation of a keypad. Disconnect telephone line before servicing. Refer to AC Power & Backup Battery Connections on page 61. The "BELL" output will shutdown if the current exceeds 3A. Connection for Self-Contained Bell/Siren The sum of the current drawn from the BELL and AUX must be limited to 1.3A (40VA transformer strongly recommended). Exceeding this limit will overload the panel power supply and lead to complete system shutdown. Solid-state PGM (+/- trigger on PGM4 only. Refer to Single Zone Inputs on page 59 Cold water pipe grounding AWG#14 single conductor solid copper wire Ground clamp To provide maximum lightning protection we strongly recommend having separate earth connections for the dialer and zone ground terminals. To metallic enclosure Max. amount of keypads = 15 keypads Max. aux. current = 700 mA Max. distance of keypad from panel = 76m (250 feet) Max. total run of wire = 230m (750 feet) AUX Power Refer to transformer requirements on page 61 for Aux. Power Output. To connect additional wiring to auxiliary power, use the red (+) and black (-) keypad connectors. Auxiliary power will shut down if current exceeds 1.1A. If the auxiliary output is overloaded and is shut down, you must disconnect all loads from the output for at least 10 seconds before reconnecting any load back to the auxiliary output. This equipment must be installed and maintained by qualified service personnel only. For UL and C-UL warnings, refer to the UL and C-UL Warnings section at the back of the Reference & Installation Manual. * If EOL is enabled: see section [706] option [2]. For the keypad's zone configurations, refer to Installer Quick Menu on page 65. Also refer to keypad zone connections on page 59. For the keypad's zone configurations, refer to the Installer Quick Menu. If EOL is enabled: see section [706] option [2]. Also refer to Keypad Zone Connections on page 59. * Magellan / Spectra SP 2 SP5500 PCB Layout Charge LED: Charging and battery test LED Status LED: · Flash once every second = Normal · Flashes ON 1 second and OFF 1 second = Any trouble · Always ON = Panel is using phone line · Fast flash 6 seconds after power up = Installer lock enabled Used for In-Field Firmware upgrade through a 307USB Direct Connect Interface. See Connecting to WinLoad on page 62 for details. Four pin connector can be used for quick installation of a SP5500 keypad. PGM +/- trigger not supported by the SP5500 EBUS and Dialer used with: VDMP3 plug-in voice module for voice reporting PCS100 GSM communicator module Press and hold the RESET button for five seconds. The STATUS LED will start flashing. Within 2 seconds of this flashing, press the reset switch again. The panel will reset to default and restart. Disconnect telephone line before servicing. Paradox Memory Key (PMC-4, PMC5) Refer to AC Power & Backup Battery Connections on page 61. Refer to Single Zone Inputs on page 59 The "BELL" output will shutdown if the current exceeds 3A. AWG#14 single conductor solid copper wire Cold water pipe grounding AUX Power Refer to transformer requirements on page 61 for Aux. Power Output. To connect additional wiring to auxiliary power, use the red (+) and black (-) keypad connectors. Auxiliary power will shut down if current exceeds 1.1A. If the auxiliary output is overloaded and is shut down, you must disconnect all loads from the output for at least 10 seconds before reconnecting any load back to the auxiliary output. To provide maximum lightning protection we strongly recommend having separate earth connections for the dialer and zone ground terminals. To metallic enclosure Ground clamp Max. amount of keypads = 15 keypads Max. aux. current = 700 mA Max. distance of keypad from panel = 76m (250 feet) Max. total run of wire = 230m (750 feet) Connection for Self-Contained Bell/Siren * If EOL is enabled: see section [706] option [2]. For the keypad's zone configurations, refer to Installer Quick Menu on page 65. Also refer to keypad zone connections on page 59. For the keypad's zone configurations, refer to the Installer Quick Menu. If EOL is enabled: see section [706] option [2]. Also refer to Keypad Zone Connections on page 59. The sum of the current drawn from the BELL and AUX must be limited to 1.3A (40VA transformer strongly recommended). Exceeding this limit will overload the panel power supply and lead to complete system shutdown. This equipment must be installed and maintained by qualified service personnel only. For UL and C-UL warnings, refer to the UL and C-UL Warnings section at the back of the Reference & Installation Manual. 3 Programming Guide SP6000 PCB Layout LEDs Charge LED: Charging and battery test LED Status LED: · Flash once every second = Normal · Flashes ON 1 second and OFF 1 second = Any trouble · Always ON = Panel is using phone line · Fast flash 6 seconds after power up = Installer lock enabled Used for In-Field Firmware upgrade through a 307USB Direct Connect Interface. See Connecting to WinLoad on page 62 for details. Four pin connector can be used for quick installation of a keypad. PGM Trigger: This jumper allows you to choose whether the solid state relay PGMs are grounded (-), or give out 12V (+). EBUS and Dialer used with: VDMP3 plug-in voice module for voice reporting PCS100 GSM communicator module Press and hold the RESET button for five seconds. The STATUS LED will start flashing. Within 2 seconds of this flashing, press the reset switch again. The panel will reset to default and restart. Paradox Memory Key (PMC-4, PMC-5) Refer to AC Power & Backup Battery Connections on page 61. Disconnect telephone line before servicing. Refer to Single Zone Inputs on page 59 The "BELL" output will shutdown if the current exceeds 3A. AWG#14 single conductor solid copper wire Cold water pipe grounding AUX Power Refer to transformer requirements on page 61 for Aux. Power Output. To connect additional wiring to auxiliary power, use the red (+) and black (-) keypad connectors. Auxiliary power will shut down if current exceeds 1.1A. If the auxiliary output is overloaded and is shut down, you must disconnect all loads from the output for at least 10 seconds before reconnecting any load back to the auxiliary output. To provide maximum lightning protection we strongly recommend having separate earth connections for the dialer and zone ground terminals. To metallic enclosure Ground clamp Max. amount of keypads = 15 keypads Max. aux. current = 700 mA Max. distance of keypad from panel = 76m (250 feet) Max. total run of wire = 230m (750 feet) Connection for Self-Contained Bell/Siren * If EOL is enabled: see section [706] option [2]. For the keypad's zone configurations, refer to Installer Quick Menu on page 65. Also refer to keypad zone connections on page 59. The sum of the current drawn from the BELL and AUX must be limited to 1.3A (40VA transformer strongly recommended). Exceeding this limit will overload the panel power supply and lead to complete system shutdown. When using an SP6000 panel in conjunction with an RTX3, all K32 and K10V/H keypads must be versions 2.0 or higher. For the keypad's zone configurations, refer to the Installer Quick Menu. If EOL is enabled: see section [706] option [2]. Also refer to Keypad Zone Connections on page 59. * This equipment must be installed and maintained by qualified service personnel only. For UL and C-UL warnings, refer to the UL and C-UL Warnings section at the back of the Reference & Installation Manual. Magellan / Spectra SP 4 SP7000 PCB Layout LEDs Charge LED: Charging and battery test LED Status LED: · Flash once every second = Normal · Flashes ON 1 second and OFF 1 second = Any trouble · Always ON = Panel is using phone line · Fast flash 6 seconds after power up = Installer lock enabled Press and hold the RESET button for five seconds. The STATUS LED will start flashing. Within 2 seconds of this flashing, press the reset switch again. The panel will reset to default and restart. EBUS and Dialer used with: VDMP3 plug-in voice module for voice reporting PCS100 GSM communicator module PGM Trigger: This jumper allows you to choose whether the solid state relay PGMs are grounded (-), or give out 12V (+). May be labeled ADM2 on some panels Upper Inputs = Zones 9 to 16 Lower Inputs = Zones 1 to 8 Used for In-Field Firmware upgrade through a 307USB Direct Connect Interface. See Connecting to WinLoad on page 62 for details. Four pin connector can be used for quick installation of a keypad. Paradox Memory Key (PMC-4, PMC-5) Refer to AC Power & Backup Battery Connections on page 61. Z9 Z10 Z11 Z12 C Z13 Z14 Z15 Z16 C Disconnect telephone line before servicing. Z1 Z2 Z3 Z4 C Z5 Z6 Z7 Z8 C Refer to Single Zone Inputs on page 59 The "BELL" output will shutdown if the current exceeds 3A. AWG#14 single conductor s ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.