Download user guide, user manual, owner manual and instructions guide
5 600 brands
1 870 000 user's guides
Search a brand
Advanced Search



Our partners wish to propose you the following products


Visit REVOX official site

User manual REVOX RESYSTEM M51 - PROGR

Diplodocs help download the user guide REVOX RESYSTEM M51 - PROGR.



Download the user manual REVOX RESYSTEM M51  
Download the complete
user guide (360 Ko)
Need help, support, reviews, tips or troubleshooting for your REVOX RESYSTEM M51 products ?


You may also download the following manuals related to this product:
REVOX RESYSTEM M51 BROCHURE
REVOX RESYSTEM M51 MKII
REVOX RESYSTEM M51 MKI
Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
User guide REVOX RESYSTEM M51 - PROGR

Detailed instructions for use are in the User's Guide.

82 of of S Re:system M51-Programmer Dominating Entertainment. Revox of Switzerland. M51-Programmer Re:system Contents Introduction Preparation Update Installing the PC program Checking the software version Starting the update program Executing the update Checking the interface Selecting the module Updating the firmware Update error messages Quitting the programming Checking the results Technical data 2 2 3 4 4 5 6 6 7 8 9 10 10 11 1 M51-Programmer Re:system Introduction The modules from the M series from Revox draw a lot of their functionality from the programming of their microprocessors. In order to keep faith with the M51 "For ever young" concept, each module can be loaded with the newest software and therefore the newest functions, in a matter of seconds with the M51 programmer. So before you start, you should take a few minutes to study the following information Preparation There are 4 points that you should consider to ensure correct programming: 1. Remove all connections from the rear of the M51, including the power cable. 2. Connect the M51 either directly to the serial interface on the PC/Notebook or for a longer connection, you can use a normal SUB9-D cable (serial computer cable). 3. Plug the supplied plug-in power supply into a power outlet and connect it to the M51 programmer. If the connections have been made correctly, the red LED on the power socket should light up. 4. In order to avoid the danger of static electricity, you should discharge yourself to some metal object before starting work. 2 M51-Programmer Re:system Update Depending on the amount of modules, which are to be programmed, there are two different options: Updating individual plug-in modules If you only want to reprogram individual plug-in modules, it's enough if you just remove these from their plug-in positions. Please check the advise in the Installation section of your operating instructions. Updating the complete M 5 1 If you want to update all the M51 modules, you must remove the housing cover from the M51 as the Display module and the process-controlled power unit (Supply) are inside. Stand the M51 on its front on a nonscratch surface and remove the six screws from the underside of the housing. These connect the housing cover to the chassis. Now you can carefully remove the cover by pulling it backwards off the chassis. Return the M51 to the normal position for programming. The individual plug-in modules do not need to be removed as the programming plugs are accessible from above. The exception to this is the 5.1 Decoder module, which is in slot 7. Before removing this module, please refer to the advice in index 5.1 Decoder module / Chapter Installation in your operating instructions. 3 M51-Programmer Re:system Installing the PC program Insert the CD in your CD or DVD drive and execute the program setup.exe with a double-click. The program can be installed on all Windows® computers . Please follow the on-screen instructions displayed by the installation program. After a successful installation, a new folder REVOX will appear under Start/Programs with a sub-folder called M51 Programmer. Checking the software version Before starting with the reprogramming, you should check that the software version of the M51 is up to date. For this purpose, the M51 has a function, which displays the current software version number as well as the plug position where each of the M51 modules is located. To call the Version function, press the Setup key on the M51 for about 2 seconds. The menu shown below appears. Select the Version soft-key and shortly, the Version window is opened. 4 M51-Programmer Re:system Starting the update program If you press the version softkey again, you can switch between the various Version pages. The first column with the hash (#) sign shows the number of the module plug-in position with the digits #1 - #6. The Audio Control Center (ACC=5.1 Decoder) is defined with #9. All other numbers define internal and external M51 components. The second column defines the individual modules. The DVD module, for example, is shown as DVD-1. The last column shows each modules' software version. Non-occupied plug-in positions are marked with the text Not used Example #3 DVD-1 0.90 Clicking on the folder Programs/ REVOX/ M51-Programmer in the Start menu bar starts the Update program. After starting, the following window appears on your screen: When you are ready to continue, type YES or Ja in the input field at the bottom of the screen and then click on the OK button (see below). This line tells you that the DVD module with software version 0.90 is located in plug-in position 3. 5 M51-Programmer Re:system Executing the update After this, the main update window appears: Checking the interface The update program offers you the option of checking to see whether the serial port is communicating correctly with the M51 programmer. To use this option, click on the Check button. If the connection is correct, the following window appears with the version number of the M51 programmer: Now select from the drop-down list in the Serial Port input box, the serial interface you have connected the M51 programmer to. 6 M51-Programmer Re:system Selecting the module If an error has been identified, this is shown as follows: If the interface is working correctly with the M51 programmer, the next step is to select the module, which is to be updated. Click on the required module. In the example shown below, the Analog I/O has been selected Shortly after this, this module appears in the foreground and the information field shows the corresponding software with the current version number. Cause: - Programmer power unit is not connected or is no working correctly - The selected interface is not in fact connected to the M51 programmer Cause: - The interface connection is damaged or interrupted - The selected interface is being used by another device If you are doing a complete M51 software update, we would recommend you to access each module in the order as shown on the screen. This corresponds to the actual order of the plug-in slots as they are located in the M51. 7 M51-Programmer Re:system Updating the firmware Now connect the M51 Programmer ribbon cable to the red programming socket on the module. The exact position of the connector is marked with a red border on the screen menu. The actual update can now begin. Click on the Update Firmware button in lower right corner of the screen. The new software is loaded in three steps, which are carried out automatically by the program: ! Please note ! Please take great care to insert the plug the right way round. The correct was is defined by a coding guide pin on the plug which fits into a hole next to the programming socket. This ensures the correct polarity. If this plastic guide pin should have been broken off, this can result in incorrect polarity and damage to the module! 1.) Read out the EEProm: All customer-entered data, such as source names, station names or display and 5.1 decoder settings are read out and stored for reloading into the new software. This means that no customerspecific data is lost and the settings don't have to be repeated. 8 M51-Programmer Re:system Update error messages 2.) Program the EEProm If any errors occur during programming, these are the possible causes: The EEProm is deleted and the saved customer data is reloaded. 3.) Program Flash Cause: - The processor is defective - The processor has locked up and must be released by REVOX. The Flash memory is deleted and the new program is written to it. Cause: - A software error occurred during programming. Repeat the update - There is a problem with the connection to the module. Check the connection The Status and Progress bars keep you informed how far the program has got at each stage. Additionally, the processor type on the module in question is displayed. 9 M51-Programmer Re:system Quitting the programming When the programming is successfully completed, the following window appears: Checking the results When you have finished, you should check whether the version numbers in the M51 Update menu are the same as those in the M51 displays. To find out how to check the M51 version number, please refer to the Checking the software version chapter. Confirm the message by clicking on the Close button and remove the programming plug from the module. Now you can continue the programming with the other modules or quit the program by clicking on EXIT in the main window. 10 M51-Programmer Re:system Technical data System requirements: Win98, WinNT, Win2000, WinXP 2 MB space on the hard disk 1 serial interface M51 Programmer power supply Voltage : Voltage type: Symbols: Power requirements: 9-12 Volt Direct current or Alternating current DC / = max. 250 mA AC / ~ Errors and technical modifications excepted. Description: Version 1.82 Delivered Operating instructions Installation CD Plug-in power supply M51 Programmer Primary 230V ~ 50 Hz Secondary 9-12V / 250mA AC or DC 11

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual REVOX RESYSTEM M51.

REVOX offer a product for which we do not have the user manual? Let us know what you are looking for: site Internet, histoire, actualité, filiales, site Internet, mode d'emploi, driver, avis des utilisateurs, meilleur prix des produits, forum d'assistance aux problèmes, annuaire des marques, annuaire des constructeurs, répertoire des marques, répertoire des constructeurs, site Internet de la marque, site Internet du constructeur

Diplodocs allows you to download user manual REVOX RESYSTEM M51, user guide REVOX RESYSTEM M51, instructions REVOX RESYSTEM M51, owner's manual REVOX RESYSTEM M51, online manual REVOX RESYSTEM M51.


Access web reviews REVOX RESYSTEM M51, , DVD Player, DVD Recorder, Home Theater, Amplifier & Hi-Fi Audio.
Include the add-on to download manuals from your site, forum or blog Frequently Asked Questions Contact Diplodocs team Last searches
Last additions
Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.