9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your 3R SYSTEM WCL-03CU TOTAL : user manual, user guide, instruction manual.
Search a brand
Advanced Search

User manual 3R SYSTEM WCL-03CU TOTAL

Diplodocs help download the user guide 3R SYSTEM WCL-03CU TOTAL .

Download the complete user guide (1292 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide 3R SYSTEM WCL-03CU TOTAL

Detailed instructions for use are in the User's Guide.

3R SYSTEM.Co.,Ltd POSEIDON www.3rsystem.co.kr Liquid cooler series 3F.#28-9 Wonhyoro1-Ga, Yongsan-gu,Seoul,Korea Tel:82-2-702-0687 Fax:82-2-704-8909 User manual www.rbox.co.kr . . Thank you for purchasing our product. Before installing or using your Poseidon liquid cooler, read this manual carefully and follow instructions to ensure reliable performance of the product. Gracias por comprar nuestro producto. Antes de la instalación o del uso de su Poseidon Liquid Cooler, lea este manual cuidadosamente y siga las instrucciones para asegurarse un resultado correcto de este producto. 2 . Every Poseidon liquid cooler has been thoroughly tested and has been shipped in perfect operating condition. In the event leakage is found or parts are missing, please contact your dealer within 2 weeks after the date of purchase, and do not install it on your system. Cada Poseidon liquid cooler ha sido probado meticulosamente y ha sido enviado en perfectas condiciones para su uso. Si encuentra alguna fuga, o le falta algún componente, por favor, contacte con su distribuidor en el plazo de 2 semanas de haber adquirido este producto y no lo instale en su equipo. . . . Instruction symbols A must read Recommendation Warning/Caution Símbolos ES NECESARIO LEER Recomendaciones. Advertencias CONTENTS NOTE I-1. WCL02,WCL03 PRECAUTIONS I-2. WCL02,WCL03 INFORMATION OPTION IV-1. WCL02 , WCL03 OPTION PARTS WCL02 II-1. WCL02 PARTS II-2. WCL02 INFORMATION II-3. WCL02 INSTALLATION (Step1-14) II-4. WCL02 TROUBLESHOOTING III-1. WCL03 PARTS WCL03 III-2. WCL03 INFORMATION III-3. WCL03 INSTALLATION (Step1-4) III-4. WCL03 LACK OF COOLANT III-5. WCL03 TROUBLESHOOTING III-6. WCL03 OPTIONAL PARTS INSTALLATION I-1. ( Precautions ) , Precauciones . . · Before installing this product, please make sure your system is turned off and unplugged, to reduce the risk of electrical shock or damaging the product. · Antes de instalar este producto, por favor, asegúrese de que su sistema esté apagado y desenchufado para reducir el riesgo de electrocución o dañar el producto. . · Take care not to be scratched with sharp edges while installing this product to your system. · Tenga cuidado de no usar herramientas afiladas o puntiagudas mientras instala este producto en su equipo. . · This product is intended for the use with a personal computer only. Use of this product in other applications voids all warranties. · Este producto está fabricado para el uso exclusivo en ordenadores personales. El uso de este producto en cualquier otro tipo de aplicaciones eliminará su garantía. (A3003) . · Always handle this product with care. Avoid applying excessive force to the product as it can damage the product. · Manipule este producto siempre con cuidado. Evite aplicar excesiva fuerza sobre el producto ya que podría dañarlo. . 15 . · The liquid inside this product is irritative. Avoid physical contact. If it happens to contact with bare skin or eyes, wash it off promptly. If irritation persists, consult a doctor. · El líquido que se encuentra dentro del producto es irritante. Evite su contacto físico. Si esto ocurre y el líquido entra en contacto con su piel u ojos, lávalos con abundante agua. Si la irritación persiste, consulte a su médico. , . · Do not attempt to disassemble this product or combine it with unoriginal components from other manufacturers under any conditions. Execution of these will void the warranty. · No intente desmontar este producto o combinarlo con componentes no originales de otros fabricantes bajo ningún concepto. Este tipo de intentos eliminarán su garantía. . . · While installing this product, please be sure that the tubes are not folded or twisted, so as to not hinder normal flow of the liquid, as reduced flow rate will lower the performance and continual overload on the pump motor may result in a breakdown of the motor eventually. · Mientras instale el producto, por favor, asegúrese de que los tubos no estén doblados o enroscados, esto podría dificultar el flujo normal del líquido. La reducción del flujo producirá un menor rendimiento del producto así como una continua sobrecarga en el motor de la bomba, que podría dar lugar a la ruptura de su producto. . . · Do not drop this product or apply impact upon it. This may damage the product or cause leakage. · No golpee ni deje caer el producto. Esto podría dañarlo o producirle alguna fuga. (www.3rsystem.co.kr) . · If you have questions about the installation or operation of the product, please visit our website (www.3rsystem.co.kr). · Si tiene alguna pregunta sobre la instalación o la forma de operar de su producto, por favor, visítenos en nuestra página web . · We, 3R SYSTEM, cannot provide after-sale service for a problem or damage which resulted from not following the instructions in this manual. · Nosotros, 3R SYSTEM, no podemos proveerle de un servicio post-venta por un problema o un daño en su producto como resultado de no haber seguido las instrucciones de este manual. ( ) . 0 ~ 65 . · The circulating liquid in this product contains an antifreeze (ethylene glycol). Ambient temperature for operation is 0 ~ 65°C. · El líquido circulante que se encuentra en este producto contiene anticongelante, (glucógeno etileno). La temperatura ambiente recomendada para operar es 0 ~ 65°C. . · Specifications and improvements in the design of this product and this manual are subject to change without any prior notice. · Las especificaciones y mejoras en el diseño de este producto y manual están sujetas a cambio sin previo aviso. . · In case you feel the need for replacing all of the liquid, please purchase and use our official replacement coolant. · En el caso de que usted necesite cambiar todo el líquido, por favor, use nuestro recambio oficial de refrigerante. 1 . · During the period of one year from the date of purchase, 3R SYSTEM will repair or replace defective parts at its expense, on condition that the product has been used in a normal environment and conditions specified above. 3R SYSTEM is not liable for the damage for any other computer components. ·3R SYSTEM reparará o reemplazará las partes defectuosas sin coste alguno, por el período de un año desde la fecha de compra, siempre y cuando el producto haya sido usado en un ambiente normal y y en las condiciones especificadas más arriba. 3R SYSTEM no se hace responsable del daño de ningún otro componente de su equipo. . · It is prohibited to duplicate or copy this manual without permission from 3R SYSTEM. · Prohibido duplicar o copiar este manual sin permiso de 3R SYSTEM. . · For the latest information on our products, please visit our website. · Para las últimas noticias de nuestros productos, por favor, visítenos en nuestra página web: www.3rsystem.co.kr I-2. WCL02, WCL03 INFORMATION WCL02-90Cu 155 mm 105 mm WCL03-90Cu 80 mm WCL02-120Cu 145 mm 125 mm WCL03-120Cu 80 mm INSTALLATION SPACE 80mm size . 120mm size . AIR FLOW PERFORMANCE 200 W (Max.) Fan 4,000 RPM - 200W Fan 2,000 RPM - 170W DC12V 4W 1200cc/Min (Head) 650mm 200W (Max.) Fan 4,000 RPM - 200W Fan 2,000 RPM - 170W DC12V 4W 600 cc/Min (Head) 350mm 230 W (Max.) Fan 3,000 RPM - 230W Fan 2,000 RPM - 190W DC12V 4W 1200cc/Min (Head) 650mm 230 W (Max.) Fan 3,000 RPM - 230W Fan 2,000 RPM - 190W DC12V 4W 600 cc/Min (Head) 350mm PUMP CPU INTEL : Socket 478 , Socket 370 - P4 3.4C , Presscott 3.4E , P3 , CELERON AMD : Socket A , Socket 462 , Socket 754 - BARTON 3200 , DURON SERIES CLIP Option Parts : AMD64 3200 , Xeon (Socket 603) , LGA775 (Socket T) - 2004.SEP III-1. WCL03 SERIES PARTS . 3 . After unpacking, please check the contents of a box and be sure everything is included. 1 2 3 MM 90 MM No. Part Name WCL03-120Cu Set Description High Performance Heat-exchanger (120mm) Water Tank Radiator Cooling FAN (120mm x 120mm x 25t) Magnet Pump (4W) Aluminum Water Block with Cu Plate High performance Heat-exchanger (90mm) Water Tank Radiator Cooling FAN (92mm x 92mm x 25t) Magnet Pump (4W) Aluminum Water Block with Cu Plate for AMD CPU Motherboard for AMD 64 CPU Motherboard for INTEL P-4 CPU Motherboard Thermal Grease for Fixing the Radiator Radiator Fan Speed Control Quick Installation Guide Qty 90Cu 120Cu 1 1 set 2 WCL03-90Cu Set 1 set 3 AMD Clip Set AMD 64 Clip Set (Option) P-4 Clip Set Thermal Grease Bolt Fan Controller Quick Installation Guide 1 set 1 set 1 set 4 sets 1 pc 1 pc 4 III-2. WCL03 INFORMATION Basic Coolant Flow [ ) WATER TANK PUMP UNIT RADIATOR CPU WATER BLOCK CPU FAN (AIR) Water Block Inatallation Direction [ ] III-3. WCL03 INSTALLATION PC PC . . STEP 1 : WCL03 INSTALLATION 1. . 2. . 1. Before start installing, connect the power cable. 2. Be sure coolant flow is not hindered. 3. Be sure there is no trace of leak on tubes and fittings WCL03-120Cu WCL03-90Cu From : PC Power DC 12V ON ON From : PC Power DC 12V STEP 2 : WCL03 INSTALLATION - WATER BLOCK / PUMP UNIT FIXING 1. PC OFF . 2. . 3. CPU . P-4 CPU 1. PC PC . 2. . PC . 3. CPU [1] CPU . 4. CPU . 5. P-4 [ 2] . . 6. [ 3] . 7. [ 4] . . PC . 8. . Parts 1 1. Apply thermal grease. Apply Grease 2 2. P-4 CPU Clip Assembly 3 3. P-4 CPU Clip Assembly 4 4. Clip Tension Control AMD64 CPU (Needs Optional Parts) 1. PC POWER OFF PC CASE . 2. . PC . 3. CPU [1] CPU . 4. [2] CPU . 5. AMD64 [ 3] . . 6. [ 4] . 7. [ 5] . . PC . 8. . Parts 1 2 3 4 5 Tension Control Apply Grease 1. Apply thermal grease. 2. Water Block / Pump Unit Fixing 3. AMD64 CPU Clip LH Assembly 4. AMD64 CPU Clip RH Assembly 5. Clip Tension Control AMD CPU 1. PC POWER OFF . 2. . 3. AMD CPU CPU . Please pay special attention while installing a water block / pump unit on AMD CPU since the CPU core is located off-center on the plate and incorrect installation will greatly lower the cooling performance. Be sure the unit is placed in the right Direction and a correct clip is used in a designated place. CLIP INSTALLATION DIRECTION W/O FOAM ATTACHED W/ FOAM ATTACHED Water block Direction 1. PC PC . 2. . PC . 3. CPU [1] CPU . 4. [2] CPU . 5. AMD (foam) [ 3] . . * 3, 5 . 6. [ 4] . 7. [ 5] . . PC . 8. . 1 2 FOAM APPLY GREASE 3 FOAM 4 1. Apply thermal grease. 2. Water Block / Pump Unit Fixing 3. AMD CPU LH Clip (W/ FOAM) Fixing 4. AMD CPU RH Clip Fixing Parts 5 FOAM 5. Clip Tension Control FOAM TENSION CONTROL STEP 3 : WCL03 INSTALLATION - Radiator Bolt Fixing Parts Parts STEP 4 : WCL03 INSTALLATION - Radiator & Pump Unit Cable Connection 1. Pump Unit 4-pin Cable PC Power DC 12V 4-pin 2. Radiator Fan 3-pin Cable Fan Controller 3. Fan Controller 3-pin Cable Motherboard Fan Terminal 4. Pump Unit 1-pin Cable CPU Fan Terminal With PC Power ON , Check Water Flow for 2~3 Minutes (Check Tube's Bend ) 2-3 Noise Control ( Use Fan Controller ) WCL02-90Cu WCL02-120Cu . . Air flow WCL02-120Cu 4 From : PC Power DC 12V 1 Air flow WCL02-90Cu 1 2 3 2 CHECK LIST 1. Secure Settling of Radiator & Pump (, ) 2. No Trace of Leakage on Tube & Fitting () 3. No Overly Bent Tube, Smooth Flow ( ) 3 Parts 4 III-4. WCL03 TROUBLESHOOTING (SYMPTOM) LOW COOLING PERFORMANCE www.3rsystem.co.kr www.rbox.co.kr (POSSIBLE CAUSES) 1. CPU Insecure Mounting of the Water Block on CPU 2. Water Block Mounted in Wrong Direction 3. Wrong Coolant Flow Direction 4. Fan Radiator Fan Mounted in Wrong Direction 5. Fan Insufficient Air Flow by Radiator Fan 6. Overly Bent or Twisted Tube(s) 1. Lack of Coolant 2. Unknown Source 1. Overly Bent or Twisted Tube(s) 2. Pump Breakdown 1. Leakage in the Joint Area 2. Leakage from Certain Units (SOLUTIONS) 1. CPU (Step 2 ) Adjust tension on the CPU clips. (Refer to Step 11.) 2. (III-2 ) Refer to Section III-2. 3. (III-2 ) Refer to Section III-2. 4. Fan (I-2 ) Refer to Section I-2. 5. Fan (Step 4 ) Adjust radiator fan RPM. (Refer to Step 4.) 6. (Step 3 ) Unbend or untwist it. (Refer to Step 3.) 1. (III-5 ) Fill the water tank up. (Refer to Section III-5) 2. A/S Contact customer service. 1. (Step 3 ) Unbend or untwist it. (Refer to Step 3.) 2. A ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.