Detailed instructions for use are in the User's Guide. Omnicron 9000 series
Installation and programming Instructions
Default settings on power up User code 1234 Part set code 0000 Engineer code 9999 Cleaner code 7777 Exit time 30sec Entry time 30sec Bell Time 20min Speaker time 20min User reset YES Relay activation in part set YES Mains LED OFF (when armed) PA (sounder & relay) NOT SILENT Auto re-arm YES Bell delay OFF (0sec) Speaker delay OFF (0sec) Zone 1 E/E in part set YES Intermediate zones NONE Part set zones NONE Self-monitoring zones NONE Double knock NO To Enter ENGINEER MODE Press Reset key and enter current user code (1234) Then press program. Green CLEAR led will flash. Enter 99 then current eng. code (9999) Red ENGINEER LED will flash continuously, indicating the panel is in engineer mode. YOUR NOW IN ENGINEER MODE.
Downloaded from: http://www.guardianalarms.net
If a mistake is made in programming, press the RESET key twice and start again. ENTRY TIME Enter Eng Mode Enter 30 Two LED's show (indicating that two keys are to be pressed) Enter new time in seconds (01=10sec; 02=20sec and so on). EXIT TIME In ENG MODE Enter 31 Two LED's show (indicating that two keys are to be pressed) Enter new time in seconds (01=10sec; 02=20sec and so on). BELL TIME In ENG MODE Enter 21 Two LED's show (indicating that two keys are to be pressed) Enter new time in seconds (01=5min; 02=10min and so on). BELL DELAY In ENG MODE Enter 20 Two LED's show (indicating that two keys are to be pressed) Enter new time in seconds (01=2min; 02=4min and so on). SPEAKER DURATION In ENG MODE Enter 23 Two LED's show (indicating that two keys are to be pressed) Enter new time in seconds (01=5min; 02=10min and so on). SPEAKER DELAY In ENG MODE Enter 22 Two LED's show (indicating that two keys are to be pressed) Enter new time in seconds (01=2min; 02=4min and so on). AUTO RE-ARM ON (factory set on) In ENG MODE Enter 14 ( system will re-arm when bell stops) AUTO RE-ARM OFF
In ENG MODE
Enter 04 (auto re-arm is now off) SILENT P.A. (factory set at all sounders) In ENG MODE Enter 11 (silent P.A. will still operate the communicator relay) AUDIBLE P.A. (factory set at all sounders) In ENG MODE Enter 01 (sounders now ON) ENGINEER RESET ONLY In ENG MODE Enter 15 CUSTOMER RESET In ENG MODE Enter 05 PROG. ENGINEER CODE In ENG MODE Enter 41 Four led's lit Enter new code TO PROGRAMME A ZONE THAT CUSTOMER CANNOT OMIT In ENG MODE Enter 47 Then the zone no. required. The respective led will light as each zone is entered. Re-enter 47 TO ENABLE CUSTOMER TO OMIT ZONES PREVIOUSLY INHIBITED In ENG MODE Enter 47 Then the zone no. required. The respective led will go out as each zone is entered. Re-enter 47 TO PROGRAMME ACCESS ZONES In ENG MODE
Enter 42 then the zone number(s) that are required. As a zone is entered that zone led will light. Enter 42. The zone(s) led will go out. TO REMOVE ACCESS ZONES As above enter 42. then the zone number(s) that are required. As a zone is entered that zone led will go out. Enter 42. The zone(s) led will go out. SOAK TEST ZONES In ENG MODE Enter 45 then the zone number(s) that are required. As a zone is entered that zone led will light. Enter 45. The zone(s) led will go out. REMOVE SOAK TEST ZONES In ENG MODE Enter 45 then the zone number(s) that are required. As a zone is entered that zone led will go out. Enter 45. The zone(s) led will go out ZONE PAIRING In ENG MODE Enter 46 then the zone numbers that are required. As a zone is entered that zone led will light. Enter 46. The zones led will go out. REMOVE ZONE PAIRING In ENG MODE Enter 46 then the zone numbers that are required. As a zone is entered that zone led will go out Enter 46. The zones led will go out. PROGRAMME PART SET ZONES In ENG MODE Enter 44 then the zone numbers that are required. As a zone is entered that zone led will light. Enter 44. The zones led will go out. DE-ACTIVATE PART SET ZONES In ENG MODE
Enter 44 then the zone numbers that are required. As a zone is entered that zone led will go out Enter 44. The zones led will go out PART SET EXIT ZONE 1 (TIMED) In ENG MODE Enter 17 Zone 1 is now part set exit REMOVE PART SET EXIT ZONE 1 (TIMED) In ENG MODE Enter 17 Zone 1 is NOT now part set exit COMM RELAY ACTIVE IN PART SET In ENG MODE Enter 06 Relay is now active in part set COMM RELAY NOT ACTIVE IN PART SET In ENG MODE Enter 06 Relay is now NOT active in part set COMM RELAY ACTIVE IN PART SET In ENG MODE Enter 16 Relay is now active in part set MAINS LED ON OR OFF WHEN ARMED In ENG MODE Enter 03 (led on when armed) Or Enter 13 (led off when armed)
Press reset, reset to exit.
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual A1 SECURITY OMNICRON 9000 - INSTALLATION - QUICK REFERENCE. A1 SECURITY offer a product for which we do not have the user manual? Let us know what you are looking for: site Internet, histoire, actualité, filiales, site Internet, mode d'emploi, driver, avis des utilisateurs, meilleur prix des produits, forum d'assistance aux problèmes, annuaire des marques, annuaire des constructeurs, répertoire des marques, répertoire des constructeurs, site Internet de la marque, site Internet du constructeur Diplodocs allows you to download user manual A1 SECURITY OMNICRON 9000 - INSTALLATION - QUICK REFERENCE, user guide A1 SECURITY OMNICRON 9000 - INSTALLATION - QUICK REFERENCE, instructions A1 SECURITY OMNICRON 9000 - INSTALLATION - QUICK REFERENCE, owner's manual A1 SECURITY OMNICRON 9000 - INSTALLATION - QUICK REFERENCE, online manual A1 SECURITY OMNICRON 9000 - INSTALLATION - QUICK REFERENCE.Access web reviews A1 SECURITY OMNICRON 9000 - INSTALLATION - QUICK REFERENCE, , Safety & Domotic. |
![]() |
Include the add-on to download manuals from your site, forum or blog | ![]() |
Frequently Asked Questions | ![]() |
Contact Diplodocs team | ![]() |
Last searches Last additions |
![]() |
Sitemap | ![]() |
|||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |