Download user guide, user manual, owner manual and instructions guide
5 600 brands
1 870 000 user's guides
Search a brand
Advanced Search



Our partners wish to propose you the following products


Visit ACT official site

User manual ACT ACT10 DIGITAL KEYPAD

Diplodocs help download the user guide ACT ACT10 DIGITAL KEYPAD.

Download the user manual ACT ACT10 DIGITAL KEYPAD  
Download the complete
user guide (536 Ko)
Need help, support, reviews, tips or troubleshooting for your ACT ACT10 DIGITAL KEYPAD products ?

This product, although classified under the brand ACT, may have been manufactured by ACCESS CONTROL TECHNOLOGY after mergers, acquisitions, or a change in name.



Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
User guide ACT ACT10 DIGITAL KEYPAD

Detailed instructions for use are in the User's Guide.

· · · · As with any access control system, always ensure that there is an alternate means of escape in the event of the unit failing to operate due to power loss or in the event of fire. Unit 8, IDA Business Park, Whitestown, Dublin 24, Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587 Copyright © 1999 Access Control Technology Ltd. (18-00001-02) For full details on the ACT product range and a list of distributors, Visit our website www.accesscontrol.ie For information on programming the advanced features of the keypad, please refer to the complete programming guide on the other side of this sheet. Always remember to factory default the controller before you start programming. Always remember to place the supplied Varistor across the terminals of the door strike coil to protect the relay contacts. Never use the onboard relay to switch AC mains voltage. An external relay isolated electrically from the ACT10 should be used for this purpose. Don't forget to change the programming code to something known only to yourself. Note: The keypad may be returned to its factory default condition at any time by entering the programming mode and pressing the % three times. Press 0, then % followed by the new programming code (four digits). 4. Set Desired Relay Active Time . Press 2, then 0. Allow the buzzer to sound for the desired period. Press % to stop ­ this period is now programmed into the relay timer. 5. Exit Programming Mode. INSTALLATION NOTES 3. Change Programming Code. Press X button followed by the programming code (9999) The yellow indicator should be flashing 2. Change User 1 code. 1. Enter Programming Mode. 30 SECOND PROGRAMMING GUIDE (for typical system) Press 0, then 1 followed by the new user 1 code (four digits) The keypad is now ready for normal use. Press the X button. The yellow LED should stop flashing. IMPORTANT ACT10 DIGITAL KEYPAD Downloaded from: http://www.guardianalarms.net KEYPAD OPTIONS 30. Door Chime When set, whenever the door contact is opened, the built-in buzzer makes a chime sound and the buzzer output activates for 2 seconds. 31. Silent Operation When set, the keypad operates silently, that is no audible tones (keypresses or confirm tones) are produced from the built-in buzzer. 32. Permanent Backlighting When set (default), the keypad illumination is always on. This option will override option 42 (Auto backlighting) 33. Locksaver (Anti tailgating) When set, and when the relay is active (following a valid code or button release), the relay timer is truncated to 2 seconds when the door contact opens. This ensures that irrespective of programmed relay time, the door will be locked as soon as it closes, and any person following will have to enter a code. 34. Alarm Keypad Operation When set, the keypad may be used as a remote keypad for an alarm system. The red and green indicators are controlled by the door contact and the release button inputs respectively, and the built in buzzer is controlled by the interlock input. 35. Interlock When set, two or more keypads may be interlocked so that only one controlled door may be open at any one time. The interlock output is active whenever the relay is active or when the door contact is open. When the interlock input is active the release button and all codes are inactive, and the red indicator flashes. The interlock outputs and inputs of any number of keypads may be combined on a single wire. 36. Six Digit Codes When set, all user codes and the programming codes are six digits long. The default user one code becomes 123456 and the default programmer code becomes 999999. 37. Twin Codes When set, two different codes must be entered within 15 seconds in order to open the door. The outputs activated are those which have been programmed for the first code to be entered. 40. Door Forced Alarm When set, the buzzer output is activated if the door contact opens when a valid code has not been entered. The output is deactivated when a valid code is next entered. This is useful for monitoring fire doors etc. 41. Group Disable When set, the top five user codes (5-9) are inactive any time the interlock input is activated. This restricts access to certain codes under external control (i.e. an alarm system output or a time clock). 42. Auto Backlighting When set, the keypad illumination is normally off, but will switch on in response to any key being pressed or while in programming mode. This option is overridden by option 32 (permanent backilghting). To prevent any illumination, unset options 32 and 42. 43. Door Ajar Alarm When set, and the door contact has been open for longer than the time programmed into the door ajar timer, the built­in and external buzzers sound intermittently. The buzzers may be silenced by closing the door and entering a valid code. 44. Guest Button When set, (default) and when the # key on the keypad is pressed, the buzzer output is activated for the duration programmed in the guest buzzer timer. 45. Fire Alarm Override When set, the relay is held active whenever the interlock input is active, and the green indicator will flash. This is useful for following a fire alarm system to override controlled doors. 46. Release Button for Second door When set, The keypad activates the door 2 relay which follows output 2's timer, this allows two doors to be controlled using one keypad. 47. Duress Codes When set, and when a duress code is entered, the door is opened normally and output 2 is activated. A duress code is any valid user code with one added to the last digit. The output will be reset when a valid user code is entered. When the duress option is set, user codes which have 9 as the last digit should be avoided as there is no corresponding duress code. Incorrect Code Lockout When three invalid codes have been entered in a row. The keypad will enter lockout mode for 20 seconds. During this time, the red indicator will flash and all user coded will be inactive . ACT10 Digital Keypad Programming To enter programming mode: Press the X button followed by the engineering code (initially all 9999) The Yellow LED will flash while in programming mode . If X is pressed at any time or no key is pressed within 30 seconds, programming mode is exited. Changing Codes: (from programming mode) Enter 0 (Change codes) 0-9, % (user number 0-9, % = programming code) 000000-999999 (4 or 6 digit code ­ 000000 deletes user) Default user codes : Programming = 9999(99), User 1 =1234(56), All others inactive. Setting switched output combinations: (From programming mode) Enter 1 (Set Outputs) 0-9 (User number 0-9) 0-7 (Output function code) Function Code Door Output Output 2 Output 3 0 Toggled 1 Timed 2 Timed 3 Timed Timed 4 Timed 5 Timed Timed 6 Timed Timed 7 Timed Timed Timed Default function code is 1 (Relay Timed) for all users. When the door is toggled open, this will be indicated by the green indicator flashing. Setting timers: (From programming mode) Ente r 2 (Set Timers 0-4 (Timer number) {Buzzer sounds indicating timing... wait required period} % (Stop timing) {Buzzer stops ­ timer set} Timer No. 0 1 2 3 4 Function Relay time Output 2 time Output 3 time Door Ajar time Guest Buzzer time Default 5s 5s 5s 30s 2s Timers may be set to any duration between 2 seconds and 4 minutes. Setting Configuration: (From programming mode) Enter 30-37 or 40-47 0-1 Option No. 30 31 32 33 34 35 36 37 40 41 42 43 44 45 46 47 (Option number) (1= Set, 0 = Unset) Function Door Chime Silent Operation Permanent Backlighting Default Off Off Off Locksaver (Anti Tailgating) Off Alarm Keypad Operation Off Interlock Six Digit Codes Twin Codes Door Forced Alarm Group Disable Auto backlighting Door Ajar Alarm Guest Button Fire Alarm Override Second Door Release Duress Codes Off Off Off Off Off Off Off On Off Off Off Restoring Factory Defaults (From Programming Mode) % % % (Factory Defaults Restored & Keypad exits programming mode) If the programming code has been forgotten. 1. Remove link LK1. 2. Apply power to unit. 3. Replace link LK1. 4. Remove power. 5. Restore power and proceed with programming. Note: The keypad will not operate correctly without LK1 in place. Typical ACT10 Configuration (Normally de-energised lock shown) Power up without link if Progr amming code has been lost. +V 0V 12-24 AC/DC Power Supply 12-24V ACDC Door Release Button LK1 + N/C C N/O OMR ON 5A 2 5 0A C V 5 A 3 0 V DC OMR ON 52 5 0 V A C A 5 3 0 V DC A Door Contact 0V Interlock (PB2) Push Button Door Contact OUTPUTS INPUTS 0V Buzzer OP3 Duress OP2 Interlock TAMPER Batch: 20xx-1 Product:ACT10 Rev3.0 Serial No. 12345 Important ! Always Place Varistor Across All Lock Terminals +V Guest Buzzer 0123456789 N/C C N/O Volt - Free Tamper Contacts Door Release Button for Door 2 This diagram shows revision (3.1) of the ACT10 This unit may be used to control 2 doors as illustrated in the diagram above. Connections and programming for this unit are exactly the same as for previous versions, however the connector positions have changed as shown in the above diagram. Unit 8 IDA Business Park, Whitestown, Tallaght, Dublin 24, Ireland. Telephone: 353 1 462 2585. Telefax: 353 1 462 2587. E-mail: sales@accesscontrol.ie Web: www.accesscontrol.ie RELAY DOOR 2 +V 0V Power Supply 12-24V ACDC Door 2 ACT 10 Digital Keypad Guides to outdoor installation in exposed areas. Access denied Standby Access Granted · Do not apply silicone to the bottom of the keypad as this will block the air vents and trap any water which may enter the keypad. · If a weather cowl is fitted the same applies. · Do install a weather cowl when the keypad is installed on an uneven surface or if in a very exposed area. · Do apply silicone to the top and two sides of the keypad or cowl, when used. · Do silicone all screw mounting positions and cable entry.

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ACT ACT10 DIGITAL KEYPAD.

ACT offer a product for which we do not have the user manual? Let us know what you are looking for: user guide, owner's manual, online manual, operating instructions, quick start guide, mounting instructions, schematics, service manual, installation instructions, RTFM.

Diplodocs allows you to download user manual ACT ACT10 DIGITAL KEYPAD, user guide ACT ACT10 DIGITAL KEYPAD, instructions ACT ACT10 DIGITAL KEYPAD, owner's manual ACT ACT10 DIGITAL KEYPAD, online manual ACT ACT10 DIGITAL KEYPAD.


ACT ACT10 DIGITAL KEYPAD, , Software.
Know our Partners Frequently Asked Questions Contact Diplodocs team Last searches
Last additions
Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.