|
5 600 brands
1 870 000 user's guides |
|
|
|||||||||||||||
|
Search a brand
Advanced Search
|
Our partners wish to propose you the following products
|
User manual ACT ACT1000
Diplodocs help download the user guide ACT ACT1000.
You may also download the following manuals related to this product:
This product, although classified under the brand ACT, may have been manufactured by ACCESS CONTROL TECHNOLOGY after mergers, acquisitions, or a change in name.
Preview of the first 3 pages of manual
You either have JavaScript turned off or an old version of Adobe Flash Player Get the latest Flash Player.
User guide ACT ACT1000
Detailed instructions for use are in the User's Guide. access control TECHNOLOGY
Operating & Installation Instructions for ACT2000 Enhanced & ACT1000 Access Control Units
CONTENTS
Default Code ..........................................................................................................1 Menu Navigation Keys..........................................................................................1 Text Entry Keys ....................................................................................................1 OPERATOR MENU ............................................................................................2 User Set-up ..........................................................................................3 Enable ....................................................................................3 Disable ....................................................................................3 Assign Names .........................................................................3 Assign Groups ........................................................................3 Assign Options ........................................................................4 Assign PINs.............................................................................4 Learn .......................................................................................4 Batch Cards ............................................................................5 One-To-One ............................................................................5 Group Set-up .......................................................................................5 Enable......................................................................................5 Disable ....................................................................................6 Assign Names..........................................................................6 Access Rights ..........................................................................6 Assign Options ...................................................................... 6 Assign PINs ............................................................................7 System Log ..........................................................................................7 Display Log ............................................................................7 Print Log..................................................................................7 Recommended Printer / Printer Settings.................................8 Filter Log (ACT2000 Only) ....................................................8 Control Door ......................................................................................8 Lock Door ..............................................................................8 Unlock Door............................................................................8 Normalise Door ......................................................................8 Pass Door ................................................................................8 AUX output on ........................................................................9 AUX output off ......................................................................9 User Tracking (ACT2000 Only) ........................................................9 Log in (ACT2000 Only) ........................................................9 Log out (ACT2000 Only) ......................................................9 Clear All (ACT2000 only) ......................................................9 Set Date/Time ......................................................................................9 Time Zones ........................................................................................10 Set Holidays ......................................................................................11 Issue Number ....................................................................................11 Change PIN ......................................................................................11
CONTENTS
INSTALLER MENU ..........................................................................................12 System Settings..................................................................................14 Operation ..............................................................................14 Display ..................................................................................14 PIN Length ............................................................................14 Fire Doors..............................................................................15 User Tracking (ACT2000 Only)............................................15 Outputs (ACT2000 Only)......................................................15 Door Settings ....................................................................................16 Operation ..............................................................................16 Alarms ..................................................................................16 Timers ....................................................................................17 Timed Actions........................................................................17 Communications ..............................................................................17 Set Address ............................................................................17 Direct Conn. ..........................................................................17 High Speed ............................................................................18 Slave Mode (ACT2000 Only) ..............................................18 No Hist. Log ..........................................................................18 Print All ................................................................................18 Remote Doors (ACT2000 Only) ..........................................18 Card Set-up ......................................................................................18 Site Code 1 ............................................................................19 Site Code 2 ..........................................................................19 Card Format ..........................................................................19 Change PIN ......................................................................................19 Factory Default ................................................................................19 DIAGRAMS ........................................................................................................20 ACT1000 Configuration Standalone ..............................................20 ACT2000 Configuration Standalone ..............................................21 DS100 Door Station Installation......................................................22 Wiring for Entry / Exit Readers......................................................23 ACT20 Pin Pad Installation Diagram ............................................24 ACT1000/2000 PC / Printer and Modem Cables ..........................25 Interlock Configuration ..................................................................26 Fire Override Configuration............................................................26 ACTWinPro Configuration..............................................................27 ACT 4-Line Network Wiring ..........................................................28 ACT Single Line RS-485 Converter................................................29 ACT Modem Configuration ............................................................30 ACT LAN Configuration ................................................................31 ACT System Configuration ............................................................32
ACT1000/2000 Operating Instructions
Software Version 4.00-00
Operating Instructions for ACT1000/2000 Access Control Units
Software Version: 4.00-00 All user functions are accessed via two six-digit codes. The first code is for the Operator who is responsible for the day-to-day administration of the system, adding and deleting users, setting names and assigning time-zones etc. The second code is for the Installer who performs the initial configuration of the system and decides on communications settings, interfaces, and modes of operation.
Operator
Default Codes 123456 Installer Menu System
999999
All user functions are accessed via a menu system. The menu (or submenu) title appears on the top line of the display. The bottom line contains the current item in the menu. The three keys on the bottom row of the keypad are used for navigation:
Menu Navigation Keys
Quit to previous menu Next menu item Select item or Submenu
Text Entry
Textual descriptions (user names etc.) are entered via a simple text entry system. Each of the digits 1-9 may be used to enter letters, numbers or symbols according to the table below. Pressing the required digit once will bring up the first letter in that group. Subsequent presses will step through the group and then back to the first letter. Pressing the 0 key advances to the next character and pressing the key moves back to the previous character. The key accepts the currently displayed text. If the cursor is at the first location in the display, pressing the key gives the option to cancel all the displayed text.
Text Entry Keys
1 4 7 abcABC1 jklJKL4 stuvSTUV7 Previous Character 2 5 8 0 defDEF2 mnoMNO5 wxyzWXYZ8 Next Character 3 6 9 ghiGHI3 pqrPQR6 SPC - & . + ` / 9 0 Accept displayed text
1
ACT1000/2000 Operating Instructions
Software Version 4.00-00
Operator Menu
User Setup Enable Disable Assign Names Assign Groups Assign Options Assign PINs Learn Batch Cards One-To-One Card Validity2 Enable Disable Assign Names Access Rights Assign Options Assign PINs Display Log Print Log Filter Log2 Lock Door Unlock Door Normalise Door Pass Door AUX output on AUX output off Log in Log out Clear All Allow a user or range of users to open the door Prevent a user or range of users from opening the door Enter a name for each user Assign users to groups Specify options for each user Set the individual PIN for each user Learn randomly coded cards (e.g. Bank Cards) Assign a batch of cards to a range of users Assign a card to a user Set a validity period for a user. Allow users in specified groups to open the door Prevent users in specified groups from opening the door Enter a name for each group Specify what access rights apply to each group Specify output and PIN options for each group Set the PIN for each Group. Show the system log on the display (recent events first) Print the system log on an attached serial printer Prevent events entering the system log Lock door - prevent all cards from opening it. Unlock door - relay is activated so cards are not required. Set a door back to normal operation Momentarily open a door for the programmed time Switches the auxiliary output on Switches the auxiliary output off Log a user into the tracking area Log a user out of the tracking area Remove all users from the tracking area
Group Setup
System Log
Control Door1
User Tracking2
Set Date/Time Time Zones Set Holidays Issue Number Change PIN
Set the current date and time for the system Specify the time periods and days which apply to a given timezone Specify which days within the next year are holidays Set the current system issue level (if issue checking option enabled) Change the PIN used to access the operator menu
Exit from the menu is automatic if no keys are pressed for a period of time. On the ACT2000, you will first be prompted for a door. 2 Only present on ACT2000
1
2
ACT1000/2000 Operating Instructions
Software Version 4.00-00
User Setup
The User Setup menu allows the operator to enable and disable individual users, and to change the configuration information for each user. In each of the user setup functions, the user is selected by either using the 0 key to advance to the required user, or alternatively by using the numeric keys 1-9 to directly enter the number of the desired user. The top line of the display will show the name for each user if one has been entered, otherwise the number only will be displayed. ENABLE The Enable function allows a user or range of users to be enabled. Pressing the key enables the displayed user. This means that the card or token belonging to this user will be recognized and may be allowed entry to the protected area. Note that the group disable function or programmed access rights may override an enabled user. DISABLE The Disable function allows a user or range of users to be disabled. Pressing the key disables the displayed user. This means that the card or token belonging to this user will no longer be recognized and will not allow entry to the protected area. ASSIGN NAMES The Assign Names function allows a 16 character textual name to be assigned to each user between 1 and 200/2000 (200 on the ACT1000, 2000 on the ACT2000). This name will be shown with any displayed or printed log events involving this user. Pressing the key selects text entry mode. ASSIGN GROUPS The Assign Groups function allows a user or range of users to be assigned to a group. On the ACT2000 any of the 20,000 users can be assigned to one of 1024 groups, the ACT1000 users 1 to 1000 may be assigned to one 16 group. By default, all users belong to Group 1. The Display will show the user number on the top line and the group that that user is assigned to on the bottom line. The displayed user number may be advanced by the 0 key. Also any user may be displayed by entering the user number, and then pressing the key followed by the key. Pressing the key prompts for a group number to be entered, entering the group number and pressing the key again assigns the currently displayed user to the group entered. A range of users may be assigned to the displayed group number, entering the first user number in the range of users followed by the key, and then entering the last user number followed the key will assign all the users in the range to the group displayed. This method can also be used to assign a single user to a group by entering the same user number for the first and last user in the range. All users above 1000 on the ACT1000 always belong to Group 1 (unless programmed via ACTWinPro).
3
ACT1000/2000 Operating Instructions
Software Version 4.00-00
ASSIGN OPTIONS The Assign Options function allows additional options to be assigned to each of the 20,000, on the ACT1000 this is limited to the first 1000 users. The available options are displayed in brackets in the form [23T] with non-assigned options displayed as a dash. Pressing the key allows the options to be altered. When changing options, the 0 key advances to each option, and the key selects or deselects the displayed option Option 2 3 T Activate O/P 2 Activate O/P 3 Toggle Relay Description The general-purpose output OP2 is activated for its programmed duration when this user is granted access. The general-purpose output OP3 is activated for its programmed duration when this user is granted access. When the user is granted access, the relay is toggled so the door will remain permanently open until the next time the card or token is read.
Note: The options assigned to an individual user operate in addition to those assigned to the group. ASSIGN PINS The Assign PINs function allows a different PIN to be assigned to each of the first 1000 on the ACT1000 and all 20,000 users for on the ACT2000. Initially, the PIN will be unset. Pressing the key will prompt for the PIN for the displayed user to be entered (it will not be displayed). The PIN must then be re-entered for verification. The PIN will be accepted as long as it does not conflict with any existing PIN (or duress PIN). Entering all zeros will delete the PIN. The actual PIN is never shown on the display. In PIN Only operation, this is the PIN that that user must enter to gain access. In this case, the PIN must be unique. In PIN & Card operation, this is the PIN that must be entered after the user has presented a card to the reader. If a PIN for a user is not set, then the relevant group PIN may be used instead (PIN & Card only). Note On the ACT1000 if learned cards are being used on the system, then individual user PINs are not permitted. In this case the relevant group PIN should be used instead. The ACT2000 allows all users to have both an individual user PIN and a learned card. LEARN In Learn Mode, any or all of the first 1000 on the ACT1000 and any or all 20,000 users on the ACT2000 users may be allocated a randomly coded card in place of the usual site coded card. Any card with valid data on ISO Track 2 may be used. Certain types of wiegand cards may also be used. Initially the display will show Not Assigned for the selected user indicating that the normal sitecoded card should be used. Pressing the key prompts the user to select a door to learn from. After selecting a door, the user presents a card to the reader at that door. When the user presents the card to the reader, a unique 10-digit number generated from the data on the card is displayed. This card may then be used to gain access, and will replace any previously learned card. Instead of presenting the card, the 10-digit number may be directly entered on the keyboard, if it
4
ACT1000/2000 Operating Instructions
Software Version 4.00-00
is known in advance. Entering all zeros for the card number will revert to using the standard sitecoded card for that user. Learning cards is particularly useful for visitors who could, for example, use their personal bankcards to gain access for the duration of their visit. BATCH CARDS The Batch Cards function allows a sequential batch of cards to be assigned to a sequential range of users (e.g. card numbers 1001 to 1200 assigned from user 1 to user 200, where user 1 has card 1001). The ACT1000 can have up to 50 batches and the ACT2000 may have up to 100. Users may be assigned different cards in different batches if desired. Initially, the display will show the batch as Not Assigned. Pressing the key prompts the user to enter a 10 digit number of the first card in the batch, once entered and the _ key pressed again the user will then be prompted to enter the 10-digit number of the last card in the batch. Note: If the card number has less then 10 digits then enter the number with leading 0's so that it has 10 digits eg card number "60775" must be entered as "0000060775" If the cards entered are already assigned to another batch, then the user is prompted to try again. The display will then request the user number to be assigned to the first card in the batch. The usual site coded cards are disabled if any batch cards are assigned on the system. However, site coded cards may be entered as a batch. Learned cards operate as normal. ONE-TO-ONE In One-To-One Mode, any known card may be assigned to any of the first 1000 on the ACT1000 and all 20,000 users on the ACT2000. If the site code and card number are known then they may be entered in from the keypad or the card may also be presented to a reader (similar to Learn Mode). CARD VALIDITY (ACT 2000 ONLY) The Card Validity menu allows all users to be assigned a validity period. A user is considered invalid if the current date is not within the validity dates.
Group Set-up
A Group provides means to manage which users are allowed access to specific doors at specific times. A group consists of 8 timezones/Doors combinations plus options. The Group Setup menu allows the operator to configure these groups. Users 1 to 1000 may be assigned to any of the 16 groups on the ACT1000, any of the 20,000 users on the ACT2000 may be assigned to one of 1024 groups. Users numbered above 1000 on the ACT1000 always belong to the first group. A group is selected by either using the 0 key to advance to the required group, or alternatively by using the numeric keys 1-9 to directly enter the number of the desired group. The top line of the display shows the name of each group if one has been entered, otherwise the number will be displayed. ENABLE Enable the displayed group by pressing the key. This means that the cards or tokens belonging to all users in the group will be recognized and will be allowed entry to the protected area provided that the individual users are also enabled.
5
ACT1000/2000 Operating Instructions
Software Version 4.00-00
DISABLE Disable the displayed group by pressing the key. This means that the cards or tokens belonging to all the users in the group will no longer be recognized and will not be allowed entry to the protected area even if the individual users are enabled. ASSIGN NAMES The Assign Names function allows a 16 character textual name to be assigned to each group. Pressing the key selects text entry mode. The group name is entered or deleted in exactly the same fashion as for individual user names. ACCESS RIGHTS The Access Rights function allows up to 8 timezone and door combinations to be specified for all users in a group. When a group is selected, the combinations will be displayed on the top line of the display in the form ABCDEFGH + -. The 0 key may be used to highlight one of these combinations and the bottom line of the display will show that timezone and door combination. Pressing the key allows the combination to be altered. 1) Select Group Group 3 Timed Access ABCDEFGH+At all times Selected Doors Timezone At all times Door 7 [23---7--AB] 0 for next group to display access rights 0 for next combination to change combination
2) Displaying access rights
3) Changing timezone
0 for next timezone to select 0 for next door to select/deselect when done
4) Changing door combination
In addition, Full Access or No Access may quickly be set for the group by highlighting and selecting the + or - symbols respectively: 5) Setting Full Access ABCDEFGH+Full Access? ABCDEFGH+No Access? to set full access to set no access
6) Setting No Access
ASSIGN OPTIONS The Assign Options menu can be used to apply additional options to a group. The assigned options are displayed in brackets in the form [23TXB] with non-assigned options displayed as a dash. Pressing the key allows the options to be altered. When changing options, the 0 key advances to each option, and the key selects or deselects the displayed option.
6
ACT1000/2000 Operating Instructions
Software Version 4.00-00
Option 2 3 T Activate O/P 2 Activate O/P 3 Toggle Relay
Description The general-purpose output OP2 is activated for its programmed duration when users in this group are granted access. The general-purpose output OP3 is activated for its programmed duration when users in this group are granted access. When the user is granted access, the relay is toggled so the door will remain permanently open until the next time the card or token is read. On ACT1000 only, if the auxiliary door has been enabled, only groups with this option selected are allowed access. On ACT2000 only, if tracking bypass is enabled, then users in this group are always allowed access through antipassback doors.
X B
Auxiliary Door Track Bypass
Note: The options assigned to an individual user operate in addition to those assigned to the group. ASSIGN PINS The Assign PINs function allows a different PIN to be assigned to each group of users. Initially, the PIN will be unset. Pressing the key will prompt for the PIN for the displayed group to be entered (it will not be displayed). The PIN must then be re-entered for verification. The PIN will be accepted as long as it does not conflict with any existing PIN (or duress PIN). The actual PIN is never shown on the display. If set, a PIN directly assigned to a user will take priority over this PIN.
System Log
The System Log menu allows the operator to view events in the historical event log, and to request a printout of the entire log. DISPLAY LOG The Display Log function allows the operator to view events in the historical log directly on the LCD display. When this option is selected, the latest event in the log is displayed with the time and date on the top line of the display, and the event details being scrolled across the bottom line. Each log event will be displayed in turn (stepping backwards in time) until the end of the log is reached. Pressing the 0 key advances immediately to the previous event without waiting for it to be displayed. Pressing the key locks the current event on the display until is pressed again. Pressing the key exits from the display log function. PRINT LOG The Print Log function allows the user to request the immediate printing of the entire system log on an attached serial printer. If real-time log printing is enabled, new events will be buffered until the complete log print is completed. Note that selection of this function only starts the log printing, and this may take a few minutes to complete. The display will indicate that printing has commenced, and return to the previous menu. If this function is re-selected before the log has been completely printed, then the option to stop the printout is given.
7
ACT1000/2000 Operating Instructions
Software Version 4.00-00
ACT Recommend the Epson LQ-300: Wiring between Printer & Controller: Controller 0v TX RX
Printer SERIAL (25 way connector)
0V ............................PIN 7 TX............................PIN 3 RX ..........................PIN 20 Printer settings: CHARACTER TABLE SKIP OVER PERFORATION GRAPHIC PRINT DIRECTION AGM INTERFACE BIT RATE STATE REPLY PC850 OFF BI-D OFF SERIAL 9600BPS OFF PAGE LENGTH OF TRACTOR AUTO TEAR OFF SOFTWARE AUTO LINE FEED DATA LENGTH PARITY BIT 11 INCHES OFF ESC/P2 OFF 8 BITS NONE
FILTER LOG (ACT 2000 ONLY) The Filter Log function allows the user to prevent certain events from being entered on the system log. Normally all events are logged, but to prevent ACTWinPro from having to store a lot of information on a large installation, some events may be filtered out. The event types that can be filtered are access granted, access denied, alarms (mains fail, tamper etc.), door events (exit button pressed etc.) and others. The 0 key advances to each event type, and the key enables or disables the displayed event type. The events may also be filtered out on certain doors. Normally all doors are allowed, but the user may prevent certain doors from reporting events.
Control Door
The Control Door menu allows the operator to control the door or externally connected equipment such as lighting or heating. LOCK DOOR The Lock Door function causes the door relay to be de-energized. The bottom line of the display will show "Door Locked" and the red LED on the reader will flash. All subsequent cards will be rejected until the door is unlocked or returned to its normal state. UNLOCK DOOR The Unlock Door function causes the door relay to be energized. The bottom line of the display will show "Door Unlocked" and the green LED on the reader will flash. NORMALISE DOOR The Normalise Door function causes the door relay to be de-energized and the door to return to its normal state. The LED on the reader stops flashing and all subsequent operation will be the normal response to card activity. PASS DOOR The Pass Door function causes the door relay to be energized for the programmed period of time. This may be used to grant access to a person waiting outside the door.
8
ACT1000/2000 Operating Instructions
Software Version 4.00-00
AUX OUTPUT ON The AUX output on function causes the auxiliary output relay to be energized. It will remain energized until the output is explicitly switched off. The output may be used to control externally connected equipment such as lights or heating. AUX OUTPUT OFF The AUX output off function causes the auxiliary output relay to be de-energized. The output may be used to control externally connected equipment such as lights or heating.
User Tracking (ACT2000 Only)
The user tracking option allows the controller to remember which users are in or out of the defined area. If antipassback doors are assigned, then these define the tracking area, however users will not be allowed to re-enter the area until they have been recorded as exiting. If perimeter doors are assigned, then these define the tracking area, however users may re-enter without restriction. If both are assigned, then the antipassback doors define the tracking area. The Users Present output and User Limit A & B outputs operate on the tracking area. LOG IN (ACT2000 ONLY) This function manually enters a user into the area. An event is logged for tracking. This is typically used when a user has forgotten their card. Manual login is not available if antipassback doors are defined - card access MUST be used. LOG OUT (ACT2000 ONLY) This function manually removes a user from the area. An event is logged for tracking. This is typically used when a user has forgotten their card or when they have violated antipassback procedures and require entry. CLEAR ALL (ACT2000 ONLY) This function manually removes all users from the area. An event is logged for tracking. This is typically used at the end of a day or week to remove any users from the system who have neglected to use their cards when exiting.
Set Date/Time
The Set Date/Time function allows the operator to adjust the date and time on the controller's real-time clock. The built-in clock is normally accurate to within 60 seconds per month and will occasionally need adjusting to maintain the accuracy of logged events. The display will prompt the user to enter the correct year (1996-2020), month (1-12), date (1-31), hour (0-23) and minute (0-59). The seconds will be zeroed. The prompt "Set?" is displayed on the bottom line of the LCD. The clock will not actually be updated until the key is pressed, allowing the operator to wait until the time is exactly correct. Any other key will exit without altering the time. The day of the week calculation, millennium and leap year adjustments are made automatically by the controller's internal clock, even if power is not present. ACTWinPro automatically changes the controller time to match that of the PC. For Summer and Winter time changes, the controller must be connected to ACTWinPro.
9
ACT1000/2000 Operating Instructions
Software Version 4.00-00
Time Zones
A timezone is a combination of times and days. Timezones are part of the group configuration, and provide the times and days when users assigned to a group may have access. As an example: In a manufacturing environment, production workers are allowed access Monday to Thursday from 8.30 to 17.00, and on Friday from 8.30 to 15.00 only. To grant access to the workers at these times only, the times and days would be set up in a timezone, and then group would be configured with this timezone using the Access Rights menu. Users assigned to this group would only have access at the specified times and days. Each timezone consists of up to five periods of time and a corresponding combination of assigned weekdays or holidays. The timezone is in force during the hours specified in any of the five time periods, but only on the days specified for that period. The current timezone number will be displayed on the top line of the display. The desired timezone may be selected using the 0 key or directly by entering the timezone number. The lower line on the display will indicate if that timezone is active or inactive. Pressing the key allows the timezone to be edited. In edit mode, the top line of the display shows the available periods in the form ABCDE * -. The 0 key allows one of the five periods to be selected and pressing allows the period to be set. Note: Timezones are also used by Timed Actions, which are part of Door Settings. 1) Select Timezone Timezone 3 Inactive ABCDE+Week Days 08:30 -> 17:00 Wednesday [TWTF---1--4] 0 for next timezone
to edit timezone
2) Select period
0 for next period to edit period
3) Changing days/holidays
0 for next day/holiday to select/deselect when done 0-9 to set time for next minute/hour when done
4) Changing time period
Period 08:30 -> 17:00
In addition, the timezone may be assigned a name or all time periods cleared quickly by highlighting and selecting the * or - symbols respectively: 5) Assigning timezone name ABCDE*Assign name? ABCDE*Clear?
10
to assign name to clear timezone
6) Clearing a timezone
ACT1000/2000 Operating Instructions
Software Version 4.00-00
The assigned name will be displayed in place of Timezone N whenever the timezone is displayed or being selected from a list. In addition, there is a built in timezone "24 Hours" which is always active. There are 16 timezones available on the ACT1000 and 128 available on the ACT2000.
Set Holidays
The controller has a built in holiday scheduler that is used in conjunction with the operation of the timezones. When the scheduler is entered, the top line of the display shows the twelve months in the form JFMAMJJASOND -. A particular month may be selected by using the 0 key, and the key allows that month to be edited. 1) Select month JFMAMJJASOND March Wed 1 March 2000 Holiday 1 0 for next month to edit month 0 for next day to change holiday type when done
2) Edit holiday
Any number of days within the next year may be tagged as being holidays. In effect, each holiday type is an extra day of the week, and will ensure that only timezones with the correct holiday types selected will be active.
Issue Number
This option allows the user to set the current system issue level to a number between zero (default) and 255. Only cards that have an issue number greater than or equal to the system issue level will be granted access. A card without an issue number encoded (Proximity, Wiegand, etc.) has an effective issue level of zero. Issue numbering is intended for use in situations where all cards on the system are replaced on a regular basis. As an example, a health club might use its membership cards to allow the members access to different facilities. Towards the end of the year when members renew their subscription, they are given a new membership card with a higher issue number encoded on it. For a period of time, the old and new cards will both be granted access. At some point in the New Year, the system issue level is increased to the new level, leaving only paid up members with access. Life members could be given cards with an issue level of 255, which will always work. Note: Issue numbering is usually only possible with standard ACT site-coded cards.
Change PIN
The Change PIN function allows a different PIN to be configured for the operator. The user will be prompted to enter a new six-digit code (it will not be displayed). The PIN must then be re-entered for verification. The PIN will be accepted as long as it does not conflict with any existing code (or duress code).
11
ACT1000/2000 Operating Instructions
Software Version 4.00-00
Installer Menu
System Settings Operation PIN Only Learn Ext. Keypad1 KPD Release1 Exit PIN's Second Door1 User Limiting2 One-To-One Multiple Display Backlight Keypad Beep Show Status Show Events Handshake Tech Bleep2 PIN's alone are used to gain access Users 1-1/2000 may use random coded cards Use external ACT20 keypad Key is exit button. Exit PIN's may be used in PIN only mode Second (Auxiliary) door enabled on ACT1000 Prevent access if the user limit is reached Card numbers may be assigned to Users 1-1000/2000 Users may have multiple cards Keypad backlight enabled Keypad beep enabled Display current status of doors on LCD Display events on LCD as they occur Use handshake line when printing Controller bleeps for technical fault
PIN Length Fire Doors User Tracking2
Sets the length of user/group PIN codes. Allows the definition of doors with fire override. Perimeter Antipassback Tracking Reset User Limits Door 1 Door 2 Push Button Lock Saver Chime Guest Button Exit Always Interlock Silent Exit PIR Failsafe Door Forced Door Ajar Duress Alarm Door Open Acc. Granted Acc. Denied Define Perimeter doors Define Antipassback doors Set time for auto-reset (auto-logout) Set user limits A & B Define door 1 output special functions Define door 2 output special functions Door release button enabled Relay de-energized as door opens Buzzer sounds as door opens on external keypad fires AUX/buzzer Timezones don't apply to exit readers Only one door may be open at any time. Confirmation tones disabled Door stays open while Push Button closed Door relay is normally energised Buzzer o/p active if door forced Buzzer o/p active if door left ajar Buzzer o/p activated by duress code Buzzer o/p active while door open Buzzer o/p when access granted Buzzer o/p when access denied
Outputs2
Door Settings*
Operation
Alarms
1 2
Feature present on ACT1000 only Feature present on ACT2000 only * On ACT2000 you will first be required to select a door.
12
ACT1000/2000 Operating Instructions
Software Version 4.00-00
Door Settings* (contd.)
Timers
Relay Time OP2 Time OP3 Time Ajar Time AUX Time Door Ajar Door Forced Door Closed Push Button Read Error Mains Fault2
Time for which relay is active Time for which OP2 is active Time for which OP3 is active Max time which door can be open Time for which AUX output is active Buzzer o/p active if door left ajar Door Forced events report in log Door Closed events report in log Push Button events report in log Log and report reader errors Log and Report an electric Mains Fault Specify times when door is unlocked Specify times when door is locked Specify times when PIN is required Specify times when any card gains access Specify times when OP2 is active Specify times when OP3 is active Specify times when AUX is active Specify times for PIN Only operation Specify times for PIN or Card operation
Reporting
Timed Actions Unlock Door Lock Door PIN Required Any Card Activate OP2 Activate OP3 Activate AUX PIN Only PIN or Card2
Assign Name Assign a name to a door Communications Set Address Direct Conn. High Speed Slave Mode2 No Hist. Log Print All Remote Doors2 Set Password Set the network address of this door Specifies that this controller is connected directly to a PC Sets the network communications speed to 19200 baud Specifies that this controller is a slave under ACT5000pc Disables the reporting of offline log events in slave mode. Enables real-time logging on attached serial printer Enable/Disable remote doors connected via DS100 modules Set a password for remote communications
Card Setup
Site Code 1 Enter the primary site code for the system Site Code 2 Enter a secondary site code for the system Card Format Enter a custom card format for the system Version Reader test Last Reset Displays the current software version Reads a card and displays the received information. Displays a code indicating the reason for the last reset.
Diagnostics
Change PIN
Change the PIN used to access the Installer menu
Factory Defaults Restore the system to its factory default settings. Feature present on ACT1000 only Feature present on ACT2000 only *On ACT2000 you will first be required to select a door.
1 2
Exit from menu is automatic if no keys are pressed for a period of time.
13
ACT1000/2000 Operating Instructions
Software Version 4.00-00
System Settings
The System Settings menu allows the installer to access a number of different configuration menus controlling different aspects of the setup of the controller. Pressing the key toggles the setting of a displayed option. OPERATION This menu allows the installer to select or de-select a number of options relating to the default operation of the controller. · The PIN Only option allows reader-less operation using PIN codes that are directly entered on the keyboard (or on an external keypad). Up to 20,000 codes on the ACT2000 and 1,000 may be used on the ACT1000. · The Learn option allows users to use randomly coded cards. Almost any card with valid ISO track 2 data may be used (for example bankcards) as well as some types of wiegand card. The ACT2000 supports learned card for all 20,000 users and the ACT1000 supports learned cards for the first 1,000 users. · The Ext. Keypad option allows an external ACT20 keypad to be used for PIN entry on an ACT1000 controller. By default, the ACT1000's own keypad is used. · The KPD Release option allows the key on an ACT1000 to function as an exit switch. · The Exit PIN's option is applicable for ACT1000 PIN-only systems. When set, it requires PIN codes to be entered before the user is allowed to exit. · The Second Door option allows an auxiliary door to be controlled on an ACT1000 unit. · The User Limiting option will prevent access to tracked users when the user limit is reached. · The One-To-One option allows any card number to be assigned to any of the 20,000 users on the ACT2000 and the first 1,000 users on the ACT1000. · The Multiple option allows users to have more than one card on the system. DISPLAY · The Backlight option forces the keypad to be permanently illuminated, overriding the default automatic operation, which is to operate only when a user menu has been entered. · Keypad Beep option forces the keypad to make a short beep in response to any key being pressed. This option is selected by default. · The Show Status option enables the displaying of continuous door status on the display. This option is enabled by default. · The Show Events option enables the displaying of events on the display as they occur. This option is enabled by default. · The Handshake option is used when a serial printer is connected. When selected, information will only be sent to the printer when a positive signal is applied to the RX pin on the printer port. This may be used to temporarily halt printing when the printer is disconnected or out of paper. · The Tech Bleep option specifies that the ACT2000's onboard buzzer will sound intermittently if a technical fault (mains, tamper or door offline) condition exists. PIN LENGTH The length of PIN codes used in PIN Only and PIN & Card modes may be set between 4 and 9 digits. If a PIN length greater than six is set, then the length of the operator and installer codes will increase to this length. (Leading zeros added to PIN).
14
ACT1000/2000 Operating Instructions
Software Version 4.00-00
FIRE DOORS This function allows a group of doors (or all doors) to be configured for fire override. A 0Volt signal from a fire alarm (or other) system is applied to the AUX input on door 1. This maintains normal operation. When the 0Volt signal is removed, the selected doors are held open until the 0Volt signal is re-applied. Typically, a normally-closed relay on the fire panel, with the common connected to 0Volts, is used for this purpose (see the Fire Override diagram on page 26). Please note that this facility is present for convenience only, it does not remove the need to have an alternate mechanical means of escape. USER TRACKING (ACT2000 ONLY) · If Perimeter doors are defined, then the users are tracked but not restricted. · If Antipassback doors are defined, then these define the tracking area (Perimeter doors are ignored). Users are allowed entry to the area only if they have previously exited. · Tracking Reset is used to auto-reset (log all users out) at a specific time each day, or may be reset manually. In addition users may be individually logged in or out. This is recorded in the system log. · Two User Limits A & B may be configured. These can be used to generate outputs when the number of users in the area reaches a certain level. This may be used for certain security critical areas. In addition an output may be configured to operate when any users are present within the area. This could be used to switch on or off certain equipment when the area is * empty. The larger of the two limits is also used to determine how many tracked users to admit into the antipassback area. Once this limit is reached, access is denied to other tracked users. This could be used in a car-park application. User Limiting must be enabled for this to operate (see System Settings > Operation). OUTPUTS (ACT2000 ONLY) The ACT2000 has 6 onboard outputs that can operate in addition to the local relay. These are the open collector outputs OP2 and OP3 (for doors 1 and 2) as well as the two auxiliary 1A relays. Normally these outputs function as for any door, according to the programmed user and/or door settings. However the onboard outputs on the ACT2000 may be given alternate functions as outlined below. AUX AUX Any Door Door 1 OP2 Tech Fault OP3 Any Door Open AUX Users Present Door 2 OP2 User Limit A OP3 User Limit B Auxiliary relay (1) activates when the auxiliary relay is activated for any door on the controller. Open collector output OP2 (1) activates when a technical fault condition exists (tamper/mains fail/door offline). Open collector output OP3 (1) activates when any door on the controller is open. Auxiliary relay (2) activates when one or more users are logged in to the tracking area. Open collector output OP2 (1) deactivates when the number of users in a tracking area is at or above User Limit A. Open collector output OP3 (1) deactivates when the number of users in a tracking area is at or above User Limit B.
15
ACT1000/2000 Operating Instructions
Software Version 4.00-00
Door Settings
The Door Settings menu allows the installer to access a number of different configuration menus controlling different aspects of the selected door. The door for which the settings are to be changed is first selected using the 0 key, then the key is pressed to enter the menu. The 0 key is used to select the required option or setting which is changed using the key. OPERATION This menu allows the installer to select or de-select a number of options relating to the default operation of the door. · The Push Button option allows the relay to be activated when the external push-button contact is closed. This option is selected by default. · The Locksaver (anti-tailgate) option truncates the relay timer when the door opens. This ensures that the door will be locked as soon as it closes even if a very long relay time is programmed. This also prevents overheating of the lock solenoid. · The Chime option momentarily energizes the buzzer output whenever the door contact is seen to open. The onboard buzzer also makes a chime sound. key on an · The Guest Button option activates the buzzer output for 2 seconds when the externally connected keypad is pressed (not applicable to Door Stations). · The Exit Always option allows the holder of a valid enabled card to exit at all times irrespective of the configured timezones. · The Interlock option prevents the door being opened when the AUX input is active. OP3 activates when the door is open or the door relay is active (see diagram page 26). · The Silent option prevents the door buzzer from sounding when access is granted or denied. · The Exit PIR option will keep the door open while the external push-button contact is closed. This allows a PIR to be used as the exit switch. · The Failsafe option sets the door relay to be normally energised. This means that the door will open if the power supply to the controller fails. ALARMS This menu allows the installer to enable or disable a number of alarm events that can be generated by the controller: · The Door Forced alarm occurs when the door contact opens without the relay having been energized. The buzzer AUX output is activated until a valid card is presented. · The Door Ajar alarm occurs when the door has remained open for longer than the duration programmed into the door ajar timer. The AUX output is activated while the door remains open. · The Duress alarm occurs whenever a duress code is entered during Pin & Card operation. The duress code is the PIN code for that user with the last digit advanced by one. · The Door Open alarm activates the AUX output whenever the door is open. · The Access Granted alarm activates the AUX output for the programmed time whenever a valid card is presented. · The Access Denied alarm activates the AUX output for the programmed time whenever an invalid card is presented
16
ACT1000/2000 Operating Instructions
Software Version 4.00-00
TIMERS The door timers menu allows the installer to program the time delays for the relay, AUX output, open collector outputs OP2 and OP3 and the door ajar alarm time. Each timer may be programmed with a duration from 1 to 999 seconds. The relay time may be programmed to 0 seconds, which will operate the relay for a quarter of a second approximately. This can be used for turnstile applications. Door Stations will support a maximum duration of 127 seconds.
Timed Actions
This Menu allows the user to set up a number of actions that will occur at requested times. The time that a particular action should occur is set up in a timezone and then assigned to that action. When the time timezone is in force, then the assigned action occurs for that duration. What Happens For the duration of the assigned timezone, the door remains unlocked. The Green LED on the Reader will Flash Lock Door For the duration of the assigned timezone, the door remains locked. The Red LED on the Reader will Flash. PIN Required For the duration of the assigned timezone, a valid PIN code must be entered after any card is presented. This overrides any PIN required option that may be set for any group or user. Any Card For the duration of the assigned timezone, any card presented will be granted access as long as it contains Track 2 data, even if it would not normally be granted access. Activate OP2 For the duration of the programmed timezone, the user programmable output OP2 is active. Activate OP3 For the duration of the programmed timezone, the user programmable output OP3 is active. Activate AUX For the duration of the programmed timezone, the 1A auxiliary relay output AUX is active. PIN Only For the duration of the programmed timezone, the reader is disabled, and access is granted only by entering a valid PIN. PIN or Card For the duration of the programmed timezone, either a valid PIN or a valid Card will allow access. Action Unlock Door
Communications
This menu allows the installer to configure how the controller communicates with externally connected devices or over a network. It is used primarily to configure the communications mode or address of the unit, or to specify log printer options. SET ADDRESS This option allows the address of the controller to be set when it is operating in a networked system or when directly connected to a PC. The valid address may be from 1 to 255 and corresponds to the number of the controller as configured in ACTWinPro. DIRECT CONN. This option informs the controller that it is connected directly to a controlling PC, rather than via a network interface. In this mode of operation, only a single controller may be connected to the PC via a cable (max 30m) from one of the PC serial ports.
17
ACT1000/2000 Operating Instructions
Software Version 4.00-00
HIGH SPEED Communications on the controller defaults to 9600 baud. The high speed option sets the controller to operate at 19200 baud. This option applies to direct connect to a PC, networked interface and printer modes of operation. SLAVE MODE (ACT2000 ONLY) This option selects slave mode operation as part of an ACT5000pc network. While the controller is switched into slave mode and all card events are transmitted to the network master for validation. The controller itself will not make any decisions on card events unless it is operating in fallback mode due to a network failure. This option is always set to No when using ACTWinPro. NO HIST. LOG This option suppresses the reporting of events occurring while offline in slave mode only. Normally when the controller is operating in slave mode, events are logged locally if the controller is offline, and are transmitted to the PC when communications are restored. PRINT ALL This option selects real-time printing to an attached serial printer. Each event is time stamped and printed immediately on the printer. Real-time printing will be temporarily suspended while a full log printout requested from the operator menu is in progress. REMOTE DOORS (ACT2000 ONLY) This menu is where additional door stations or ACT1000 units are configured as extra doors on the ACT2000 controller. The new door (Door 3 to 16) is selected using the 0 key and the current status of the door is displayed on the bottom line of the LCD. The key may then be used to enable or disable the door: 1) To enable, select a Disabled door 2) To disable, select an Enabled door Door 3 Disabled Door 3 Door Normal 0 for next door to enable door 0 for next door to disable door
If a non-existent or incorrectly addressed door is enabled, the door will be polled for a short while, then the status will be displayed as Door Offline. SET PASSWORD A password consisting of a 10 digit number may be programmed into the controller to prevent unauthorized access from remote ACTWinPro users. Ensure this password matches the encryption key used by ACTWinPro.
Card Setup
The card setup menu is used to inform the controller which cards should be recognized by the system. Usually all that is required is to set the primary site code for the system. The site code is supplied along with any cards ordered, or can be obtained directly from ACT. In addition, a site code from another installation may be entered allowing shared access to the building. Where nonstandard cards are being used, possibly from a previous access control or time & attendance system, the card format may be altered to accept these.
18
ACT1000/2000 Operating Instructions
Software Version 4.00-00
SITE CODE 1 This function allows the 8-digit site primary code for the system to be entered. The controller will recognize only cards with a matching site code. This code should also be quoted whenever additional cards or tags are being ordered for this installation. The factory default site-code is 10-2770-09, which allows the use of the test card supplied with the controller. SITE CODE 2 This function allows an 8-digit site secondary code for the system to be entered. In addition to the cards containing the primary site code, the controller will also recognize cards with this site code. In this case, an offset may also be specified - this is a value that is added to the card number of cards bearing the secondary site code, to prevent conflicts. If the secondary site code is not being used, it should be set to 00-0000-00. CARD FORMAT · When "Active" is set to YES, the controller will recognize cards with a non-standard (custom) format. The card information must be encoded using ISO/ABA Track 2 format and may contain from 2 to 37 digits. · When "Check All" is set to YES, the controller will also allow cards encoded with one of its standard built-in formats. This could be used (for example) in a transitional period while older legacy cards are being phased out. · The Length field contains the total number of digits on the custom card. If this value is nonzero, then any card with a different number of digits will be rejected. · The Site field allows the entry of the location of the starting digit of the site code field on the card. The length specifies how many digits are in the site code (1-5). · The Card field allows the entry of the location of the starting digit of the card number field on the card. The length specifies how many digits are in the card number (1-5). · The Issue field allows the entry of the location of the starting digit of the issue number field on the card. The length specifies how many digits are in the issue number (1-3). If issue numbering is not being used, then the start digit and length should be set to zero.
Change PIN
The Change PIN function allows a different PIN to be configured for the installer. The user will be prompted to enter a new six-digit code (it will not be displayed). The PIN must then be reentered for verification. The PIN will be accepted as long as it does not conflict with any existing code (or duress code).
Factory Default
This function returns all settings to the factory default. All user names, timezones, card enables, log information and Operator and Installer Code an all other settings are defaulted. All information previously programmed will be lost, so use this function with care. In situations where the Installer Code is unknown the Controller may be defaulted as follows. Holding down the key while powering up the Controller, when requested for a Site Code enter the ACT default Site Code 10-2770-09, When asked to default controller hit the key to default. It is always a good idea to factory default a new controller prior to initial configuration, or if the controller software has been changed or upgraded.
19
ACT1000/2000 Operating Instructions
Software Version 4.00-00
Typical ACT1000 Configuration
(Standalone)
20
ACT1000/2000 Operating Instructions
Software Version 4.00-00
Typical ACT2000 Configuration
(Standalone)
21
ACT1000/2000 Operating Instructions
DS100 Door Station Installation
22
03 OFF OFF OFF ON ON 10 OFF ON OFF ON 11 OFF ON OFF ON 12 OFF ON ON OFF ON ON 13 OFF ON 14 OFF ON 15 OFF ON 16 09 OFF ON OFF OFF ON ON OFF ON ON ON ON OFF ON ON OFF OFF ON OFF ON ON OFF OFF OFF OFF 04 OFF OFF ON OFF OFF 05 OFF OFF ON OFF ON 06 OFF OFF ON 07 OFF OFF ON
Software Version 4.00-00
08 OFF ON OFF OFF OFF
ACT1000/2000 Operating Instructions
Software Version 4.00-00
Wiring for Entry/Exit Readers
Cable: 8 Core Screened Belden 9504 or equivalent Max length 30 Metres
23
ACT1000/2000 Operating Instructions
Software Version 4.00-00
ACT20 PIN Pad Installation Diagram
24
ACT1000/2000 Operating Instructions
Software Version 4.00-00
ACT1000/2000 Cable Connections
25
ACT1000/2000 Operating Instructions
Software Version 4.00-00
Interlock Configuration
26
Fire Override Configuration
ACT1000/2000 Operating Instructions
Software Version 4.00-00
ACT WinPro Configuration
27
ACT1000/2000 Operating Instructions
Software Version 4.00-00
ACT 4-Line Network Wiring
28
ACT1000/2000 Operating Instructions
Software Version 4.00-00
ACT Single Line RS-485 Converter
29
ACT1000/2000 Operating Instructions
Software Version 4.00-00
ACT Modem Configuration
30
ACT1000/2000 Operating Instructions
Software Version 4.00-00
ACTLAN Configuration Diagram
31
ACT1000/2000 Operating Instructions
Software Version 4.00-00
ACT System Diagram
32
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ACT ACT1000. ACT offer a product for which we do not have the user manual? Let us know what you are looking for: site Internet, histoire, actualité, filiales, site Internet, mode d'emploi, driver, avis des utilisateurs, meilleur prix des produits, forum d'assistance aux problèmes, annuaire des marques, annuaire des constructeurs, répertoire des marques, répertoire des constructeurs, site Internet de la marque, site Internet du constructeur Diplodocs allows you to download user manual ACT ACT1000, user guide ACT ACT1000, instructions ACT ACT1000, owner's manual ACT ACT1000, online manual ACT ACT1000.Access web reviews ACT ACT1000, , Software. |
![]() |
Include the add-on to download manuals from your site, forum or blog | ![]() |
Frequently Asked Questions | ![]() |
Contact Diplodocs team | ![]() |
Last searches Last additions |
![]() |
Sitemap | ![]() |
|||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |