User manual ACT ACT5 DIGITAL KEYPAD
Diplodocs help download the user guide ACT ACT5 DIGITAL KEYPAD.
This product, although classified under the brand ACT, may have been manufactured by ACCESS CONTROL TECHNOLOGY after mergers, acquisitions, or a change in name.
Preview of the first 3 pages of manual
You either have JavaScript turned off or an old version of Adobe Flash Player Get the latest Flash Player.
User guide ACT ACT5 DIGITAL KEYPAD
Detailed instructions for use are in the User's Guide. ACT5 Digital Keypad Programming
30 SECOND PROGRAMMING GUIDE (for typical system)
1. Enter Programming Mode.
Press X button followed by the programming code (9999) The LED will flash Amber 2. Change User 1 code. Press 0, then 1 followed by the new user 1 code (four digits)
To enter programming mode:
Press the X button followed by the engineering code (initially all 9999) The LED will flash Amber while in programming mode . If X is pressed at any time or no key is pressed within 30 seconds, programming mode is exited.
Changing Codes:
(from programming mode) Enter 0 (Change codes) 0-9, ü (user number 0-9, ü = programming code) 0000-9999 (4 digit code 0000 deletes user) Default user codes : Programming = 9999, User 1 =1234, All others inactive.
3. Change Programming Code.
Setting the Relay active time:
Press 0, then ü followed by the new programming code (four digits). 4. Set Desired Relay Active Time . Press 2, then 0. Allow the buzzer to sound for the desired period. Press ü to stop this period is now programmed into the relay timer. 5. Exit Programming Mode. Press the X button. The LED will be Red.
(from programming mode) Enter 2 (Set Relay active Time) 0 (Relay Timer) {Buzzer sounds indicating timing... wait required period} (Stop timing) {Buzzer stops -- timer set} ü Incorrect Code Lockout When three invalid codes have been entered in a row. The keypad will enter lockout mode for 20 seconds. During this time, the red indicator will flash and all user coded will be inactive.
The keypad is now ready for normal use. Restoring Factory Defaults Note: The keypad may be returned to its factory default condition at any time by entering the programming mode and pressing the ü three times.
(From Programming Mode) üüü (Factory Defaults Restored & Keypad exits programming mode) If the programming code has been forgotten. 1. Remove the power from the unit. 2. Remove link LK1. 3. Apply power to unit. 4. Replace link LK1. 5. Remove power again. 6. Restore power and proceed with programming. Note: The keypad will not operate correctly without LK1 in place.
Unit 8, IDA Business Park, Whitestown, Dublin Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587, Copyright © 2003 Access Control Technology Ltd. (18-00001-27)
For full details on the ACT product range and a list of distributors, Visit our website www.accesscontrol.ie
As with any access control system, always ensure that there is an alternate means of escape in the event of the unit failing to operate due to power loss or in the event of fire.
·
·
·
·
Don't forget to change the programming code to something known only to yourself.
Never use the onboard relay to switch AC mains voltage. An external relay isolated electrically from the ACT5 should be used for this purpose.
Always remember to place the supplied Varistor across the terminals of the door strike coil to protect the relay contacts.
Always remember to factory default the controller before you start programming.
INSTALLATION NOTES
IMPORTANT
Downloaded from: http://www.guardianalarms.net
ACT5 DIGITAL KEYPAD
T he A CT 5 may be powered from 12 or 24V A C or DC.
Door R elease B utton
Fig 2 Mounting instructions for flush mount unit
Spacers break away from main component when required by installer for use.
View showing spacers stacking
Power up without link if Programming code has been lost
Power Supply Unit
Note :
Standard pattress box.
SCREWS
View showing mounting plate before spacers are broken away by installer. Note: Determine the distance between the pattre and the mounting plate, using the spacers are labeled 1mm to 4mm. This allows the installer to make the required spacer leng 10mm by stacking each spacer together. Security screw supplied with the unit.
Fig 1 ACT5 Wiring Diagram
Push B utton
01X X -1 P R ODUC T : AC T 5 R E V 1.0 S E R IA L NUMB E R 00X X X X :
0123456789
B A T C H:
Mounting plate is attached to the pattress box using the screws supplied, ENSURE the corect spacers have been used to bridge the gap between the mounting plate and the fixing wings of the pattress box to avoid the mounting plate being distorted.
12-24V A C/DC
LK1
0V
Place the cap onto the unit and push firmly into place.
Place the Reader / Keypad onto the surface mount collar and clip down into place.Use the security screw supplied to attach the unit to the surfce mount collar.
N/C Comm
+12V
0V
N/O
T his illustr ation shows wir ing for nor mally de-ener gised locks. I f nor mally ener gised locks ar e r equir ed, use the N/C r elay contacts.
Important! A lways Place V aristor A cross L ock T erminals
12V = DC 5A/250V ~AC
SCHRACK
Fig 3 Mounting instructions for surface mount unit
Security screw supplied with the unit.
The surface mount collar is mounted on the wall using the fixing kit supplied in the box. Place the Reader / Keypad onto the surface mount collar and clip down into place.Use the security screw supplied to attach the unit to the surfce mount collar.
Place the cap onto the unit and push firmly into place.
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ACT ACT5 DIGITAL KEYPAD. ACT offer a product for which we do not have the user manual? Let us know what you are looking for: user guide, owner's manual, online manual, operating instructions, quick start guide, mounting instructions, schematics, service manual, installation instructions, RTFM. Diplodocs allows you to download user manual ACT ACT5 DIGITAL KEYPAD, user guide ACT ACT5 DIGITAL KEYPAD, instructions ACT ACT5 DIGITAL KEYPAD, owner's manual ACT ACT5 DIGITAL KEYPAD, online manual ACT ACT5 DIGITAL KEYPAD.ACT ACT5 DIGITAL KEYPAD, , Software. |
![]() |
Include the add-on to download manuals from your site, forum or blog | ![]() |
Frequently Asked Questions | ![]() |
Contact Diplodocs team | ![]() |
Last searches Last additions |
![]() |
Sitemap | ![]() |
|||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |