Detailed instructions for use are in the User's Guide. access control TECHNOLOGY
Operating & Installation Instructions for ACTSmart
2 Product Range
ACTSmart2 Operating and Installation Manual
Rev. 1.1
Contents
Installation Notes............................................................. ......................................................................4 Product Specification ....................................................... ......................................................................4 30 Second Programming Guide (1080) ................................... ..............................................................5 30 Second Programming Guide (1090) ................................ ................................................................6 Programming Summary................................... ......................................................................................7 ACTSmart Operation ..............................................................................................................................8 ACTSmart Programming...................................... ..................................................................................8 Adding a Card Batch........................... ... ...........................................................................9 Deleting a Card Batch................................................ ..........................................................9 Adding a Pin.........................................................................................................................9 Deleting a Pin................................................... ....................................................................9 Adding a Card and Pin ........................................ ................................................................9 Deleting a Card and Pin. ......................................................................................................9 Adding a Card Batch using the keypad..............................................................................10 Deleting a Card and Pin using the keypad............... ..........................................................10 Adding a Random Card............................... ......................................................................10 Set Door RelayTime..................................... ......................................................................10 Set Door Ajar Time...................................... ......................................................................10 Set Guest Buzzer Time ......................................................................................................10 Change Programming Code........................... ....................................................................11 Change Number of PIN Digits...........................................................................................11 Limit Number of Users.................... ..................................................................................11 User Toggle ........................................................................................................................11 User Arm.................................................. ..........................................................................12 Programming ACTSmart Options.................. ....................................................................13 Setting Programmable Input Function ..............................................................................14 Setting AUX I/O 1 Function ........... ..................................................................................14 Setting AUX I/O 2 Function ..............................................................................................14 Quick I/O Setup ................................................................................................................15 Adding a Card Batch for second door................... ..........................................................15 Adding a PIN for second door ..........................................................................................16 Adding a Card and PIN for second door ..........................................................................16 Adding random Card for second door...............................................................................16 Programming a Network System ..........................................................................................................17 Assign Door Numbers ......................................................................................................17 Find Door Number ............................................................................................................18 Find All Door Numbers......................................................................................................18 Restoring Factory Default ....................................................................................................................18 Programming ACTSmart Prox only......................................................................................................19 ACTSmart Standalone wiring diagram ................................................................................................21 ACTSmart Interlock and Fire Override wiring diagram ......................................................................22 ACTSmart Network wiring diagram ....................................................................................................23 SmartLock Connection diagram ..........................................................................................................24 Alarm Wiring Diagram ........................................................................................................................25 ACTPro Reader Wiring Diagram..........................................................................................................26 2 Door Wiring Diagram ........................................................................................................................26 2 Door Wiring Diagram ........................................................................................................................27 ACTSmart System Diagram ................................................................................................................28 ACTSmart Flush mounting diagram ....................................................................................................29 ACTSmart Surface mount diagram ......................................................................................................30 User List 31 3
ACTSmart2 Operating and Installation Manual
Rev. 1.1
Installation Notes
· Remember to Factory Default the ACTSmart before programming · Remember to place the supplied varistor across the terminals of the door strike coil to protect the relay contacts · Don't mount the ACTSmart Prox units near RF sources (Eg mobile phones, radio transmitters, computer monitors) or metal surfaces. · Remember that the ACTSmart PIN and Prox units default to Card operation. Card and PIN operation must be programmed in. (See Programming ACTSmart Options section, Options 39, 40 and 41). · Don't power the unit from a switch-mode power supply. Use a linear regulated power supply. · Never use the on-board relay to switch AC mains voltage. An external relay, electrically isolated from the ACTSmart should be used for this purpose · Remember to change the programming code. · Don't power the ACTSmart from an AC power supply on a networked system. An AC power supply may only be used on a standalone ACTSmart. · The ACTSmart2 version is not compatible with the earlier version of ACTSmart. Cards and fobs for one version will not work on the other. The devices may NOT be networked together. · When ordering new cards or fobs specify ACTSmart2.
Important
As with any Access Control system, always ensure there is an alternate means of escape in the event of the unit failing to operate due to power loss or in the event of fire.
Product Specification
Number of Users Supply Voltage Current Consumption Output Current Sink Operating Temperature Door Open Time Max. ACTSmarts per network Length of network Relay Contact Rating Programmable Inputs Programmable Input/Outputs Controller Size Controller Weight Water Resistance Construction 1000 12 - 24 V DC (linear PSU) or AC (standalone only) 50mA (nominal), 80mA (maximum) 100mA -25 to +60 degrees C 0 - 255 seconds 8 1.4km maximum 5A / 250Vac 1 2 Flush Mount: 100 x 110 x 20 mm Surface Mount: 100 x 110 x 35 mm 200 grams High IP67 Rugged Polycarbonate housing with stainless steel keys and potted electronics.
Ordering Information
Model ACTSmart Proximity Only ACTSmart PIN and Proximity ACTSmart PIN Only
4
Part Number ACT 1070 ACT 1080 ACT 1090
ACTSmart2 Operating and Installation Manual
Rev. 1.1
30 Second Programming Guide
ACTSmart2 Pin & Prox (1080)
(For typical Standalone System) 1. Enter Programming Mode. Press button followed by the programming code (default is 9999) The LED will flash amber. 2. Add a Batch of Cards Press 10, then present the first card in the batch followed by the last card in the batch. Press button to complete. 3. Add a PIN Code Press 12, and then enter a 4-digit PIN code. Press button to complete. (Option 40 - Card or PIN.) 4. Set Desired Door Relay Active Time Press 20, and then enter the desired number of seconds from 000-255 (three digits with leading zeros). Press button to complete. 5. Change Programming code Press 23, then enter new 4-digit programming code. 6. Exit Programming Mode Press the button. The LED turns red. The ACTSmart is now ready for normal use. Note: The ACTSmart may be returned to its factory default condition at any time by entering the programming mode and pressing 80 followed by the button. For information on programming the advanced features and networking the ACTSmart range, please refer to the complete programming guide.
access control TECHNOLOGY
Unit 8, Tallaght Business Centre, Whitestown, Dublin 24, Ireland Tel: 353-1-4622585 Fax: 353-1-4622587 Web: http://www.accesscontrol.ie E-mail: sales@accesscontrol.ie
Copyright © 2005 Access Control Technology Ltd. 5
ACTSmart2 Operating and Installation Manual
Rev. 1.1
30 Second Programming Guide
ACTSmart2 PIN Only (1090)
1. Enter Programming Mode. Press button followed by the programming code (default is 9999) The LED will flash amber. 2. Add a PIN Code Press 12, and then enter a 4-digit PIN code. Press button to complete. 3. Set Desired Door Relay Active Time Press 20, and then enter the desired number of seconds from 000-255 (three digits with leading zeros). Press button to complete. 4. Change Programming code Press 23, then enter new 4-digit programming code. 5. Exit Programming Mode Press the button. The LED turns red. Note: The ACTSmart may be returned to its factory default condition at any time by entering the programming mode and pressing 80 followed by the button. For information on programming the advanced features and networking the ACTSmart range, please refer to the complete programming guide.
6
ACTSmart2 Operating and Installation Manual
Rev. 1.1
Programming Summary
Code 10 11 12 13 14 15 16 17 18 20 21 22 23 24 26 30 31 32 33 34 35 36 37 38 39 40 41 43 50 51 52 53 60 61 62 70 71 72 73 80 Function Add Card Batch Delete Card Batch Add PIN Code Delete PIN Add Card and PIN Delete Card and PIN Add Card Batch using keypad Delete Card Batch using keypad Add Random Card Set Door Relay Time Set Door Ajar Time Set Guest Buzzer Time Change Programming Code Change Number of PIN Digits Limit Number of Users Door Chime Silent Operation Lock-saver (Anti Tailgating) Toggle Door Forced Alarm Door Ajar Alarm Guest Button Duress Codes Network Master Card and PIN Card or PIN Card and any PIN Pulse Door Armed Set Programmable Input Set AUX I/O 1 Set AUX I/O 2 Quick I/O Setup Assign Door Numbers Find Door Number Find Door Numbers Add Card Batch for Second Door Add PIN code for Second Door Add Card and PIN for Second Door Add Random card for Second Door Default Unit
7
Default
5 seconds 30 seconds 2 seconds 9999 4 1000 Off Off Off Off On On On Off Off Off Off Off Off Door Release Button Door Contact Door Alarm
ACTSmart2 Operating and Installation Manual
Rev. 1.1
ACTSmart Operation
The ACTSmart family consists of Proximity only, Pin and Proximity and PIN only units. Each ACTSmart can operate in standalone mode. Up to 8 ACTSmart devices can be connected on a RS485 network. The ACTSmart will support a maximum of 1000 tokens. A token may be a card, keyfob or a PIN code. Each unit is contained in a rugged polycarbonate housing, with stainless steel keys and potted electronics, allowing for indoor and outdoor installation. Programming the unit is achieved via the keys and LED. For quick and easy installation, the ACTSmart has a default configuration, which is suitable for most installations. Cards and PIN codes can be programmed into the ACTSmart very quickly. ACT recommends that the user keep track of the Cardholders and PIN users on the system by using the User List at the end of the manual. Make copies of this sheet and enter each Users details on it. This will allow users to be deleted later on, even if a card is lost or a user forgets their PIN code. To improve security, PIN codes may be up to 6 digits in length. Normally only card users are allowed access through the ACTSmart PIN and Prox unit. For maximum security, the unit may be programmed to require all users to enter a PIN code after presenting a card. For lower security applications, another programming option allows access to PIN only users. A duress code feature is also available The built-in inputs and outputs are programmable, allowing the ACTSmart to be used in a wide variety of applications from simple door access, to cash offices and fire exits. Each unit also has built-in tamper monitoring for improved security. ACT also provide an easy-to-use PC application (ACTWinSmart), which allows the installer to configure systems quickly. Up to 8 ACTSmart units may be connected to the PC. The end-user may also use ACTWinSmart to monitor day-to-day activity, add new users etc.
ACTSmart Programming
Press the button followed by the programming code (initially 9999). The LED will flash amber while in programming mode. If is pressed at any time or no key is pressed within 30 seconds, programming mode is exited. If the LED flashes green during programming, then a card presentation is expected. If the LED flashes red, then a keypress is expected. While the ACTSmart is busy performing a task, (Eg. Defaulting memory, adding cards), the green led will turn on and the buzzer will sound an elongated tone. Note: In most Programming Menus there is a step that is marked (optional)*. This setting only applies to a Networked System (see Programming a Network System).
8
ACTSmart2 Operating and Installation Manual
Rev. 1.1
Adding a Card Batch:
Step 1 2 3 4 5 Keypad Entry 10 Present Card Present Card Enter 1-8, (optional)* Press Operation Add Card Batch First card in Batch (lowest number card) Last Card in Batch (highest number card) Select each door this batch enabled for End programming card batch Note: the buzzer will sound while cards are loaded into memory.
Deleting a Card Batch:
Step 1 2 3 4 5 Keypad Entry 11 Present Card Present Card Enter 1-8, (optional)* Press Operation Delete Card Batch First card in Batch (lowest number card) Last Card in Batch (highest number card) Select each door this batch deleted from End delete card batch Note: the buzzer will sound while cards are deleted from memory.
Adding a PIN:
Step 1 2 3 4 Keypad Entry 12 0001-9999 1-8, (optional)* Press Operation Add PINs (Make sure Option 40 is set on PIN and Prox units.) 4 - 6 digit PIN code Select each door this PIN is valid for End programming PINs
Deleting a PIN:
Step 1 2 3 4 Keypad Entry 13 0001-9999 1-8, (optional)* Press Operation Delete PINs 4 - 6 digit PIN code Select each door this PIN is deleted from End deleting PINs
Adding a Card and PIN:
Step 1 2 3 4 5 Keypad Entry 14 Present Card 0001-9999 1-8 (optional)* Press Operation Add Card and PIN (Make sure Option 39 is set on PIN and Prox units.)
4 - 6 digit PIN code Select each door this Card & PIN is valid for End programming Card and PINs
Deleting a Card and PIN:
Step 1 2 3 4 Keypad Entry 15 Present Card 1-8, (optional)* Press Operation Delete Card and PIN Select each door this Card & PIN is deleted from End deleting Card and PINs 9
ACTSmart2 Operating and Installation Manual
Rev. 1.1
Adding a Card Batch using the keypad:
Step 1 2 3 4 5 Keypad Entry 16 Enter 10-digit card number Enter 10-digit card number 1-8, (optional)* Press Operation Add Card Batch 10-digit First Card number with leading zeros. Eg. Card 54321 enter 0000054321. Second Card number Select each door to which these cards are enabled End Adding Card Batch -- Note: the buzzer will sound while cards are loaded into memory.
Deleting a Card or Card and PIN using the keypad:
Step 1 2 3 4 Keypad Entry 17 Enter 10-digit card number 1-8, (optional)* Press Operation Delete Card or Card and PIN 10-digit Card number with leading zeros. Eg. Card 54321 enter 0000054321. Select each door this Card is deleted from End deleting Card (Card and PIN)
Add Random Card:
Step 1 2 3 4 5 6 Keypad Entry 18 Enter 1-8, (optional)* Press Present Card Present Card (optional)* Press Operation Add random card Select each door these cards enabled for Add card Repeat for all other cards to be added End adding cards
Set Door Relay Time:
Step 1 2 3 4 Keypad Entry 20 Enter 3 digit time 1-8 (optional)* Press Operation Set Door Relay Time - (default 5 seconds) 000-255 seconds - (leading zeros required). Select each door this timer is set for End setting Door Relay Timer
Set Door Ajar Time:
Step 1 2 3 4 Keypad Entry 21 Enter 3 digit time 1-8 (optional)* Press Operation Set Door Ajar Time - (default 30 seconds) 000-255 seconds - (leading zeros required). Select each door this timer is set for End setting Door Ajar Time
Set Guest Buzzer Time:
Step 1 2 3 4 Keypad Entry 22 Enter 3 digit time 1-8 (optional)* Press Operation Set Guest Buzzer Time - (default 2 seconds) 000-255 seconds - (leading zeros required). Select each door this timer is set for End setting Guest Buzzer Time 10
ACTSmart2 Operating and Installation Manual
Rev. 1.1
Change Programming Code:
Step 1 2 Keypad Entry 23 0001-9999 Operation Change Programming code New 4 - 6 digit programming code
Change Number of PIN Digits:
Step 1 2 Keypad Entry 24 4-6 Operation Change Number of PIN digits Select number of PIN digits in range 4 to 6. When set, the codes require leading zeros Eg. Code 9999 becomes 009999 for 6 digits.
Limit Number of Users:
This function is useful if the end-user wants to limit the number of user codes and cards permitted to use the ACTSmart2. This can only be performed when the tamper is open (by removing the main unit from the mounting plate or the surface mount collar).
Step 1 2 3 Keypad Entry 26 0001-1000 Press Operation Limit the number of users allowed to use Smart2 Maximum number allowed (leading zeroes required) End Setting User Limit
User Toggle:
This function will toggle the door open or closed when a vaild card or PIN is presented. Remember the Toggle option must be set on the Smart2 (Option 33). To program a card or PIN with the toggle option, program as normal, but press 0 before the key. See the two examples below:
Adding a Card Batch with Toggle mode:
Step 1 2 3 4 5 6 Keypad Entry 10 Present Card Present Card 0 1-8, (optional)* Press Operation Add Card Batch First Card in Batch (lowest number card) Last Card in Batch (highest number card) Enable toggle mode (make sure Option 33 is set) Select each door this batch is valid for End
Adding a PIN Code with Toggle mode:
Step 1 2 3 4 5 Keypad Entry 12 0001-9999 0 1-8, (optional)* Press Operation Add PINs (Make sure Option 40 is set on PIN and Prox Units) 4-6 digit PIN code Enable toggle mode (make sure Option 33 is set) Select each door this PIN is valid for End
11
ACTSmart2 Operating and Installation Manual
Rev. 1.1
User Arm Function:
Users with this function may arm or disarm the door after a vaild card or PIN is presented. Remember the Arming Door option must be set on the Smart2 (Option 42). While the door is armed, the door is locked and access is denied to other users until the door is disarmed. The red LED flashes to indicate the door is armed. An auxilliary output may be switched to signal the state of the door. This output may be used to arm/disarm an alarm panel. The output may be programmed to pulse instead of toggle (Option 43). To arm or disarm the door, press the key followed by the PIN code or valid card. An output from the panel may be connected to the ACTSmart2 to indicate that the panel is armed. Check the Alarm Panel Wiring diagram at the end of the manual. To program a card or PIN with the arm function, program as normal, but press 9 before the key. See the two examples below:
Adding a Card Batch with Arming Function:
Step 1 2 3 4 5 6 Keypad Entry 10 Present Card Present Card 9 1-8, (optional)* Press Operation Add Card Batch First Card in Batch (lowest number card) Last Card in Batch (highest number card) Enable Arming mode (make sure Option 42 is set) Select each door this batch is valid for End
Adding a PIN Code with Toggle mode:
Step 1 2 3 4 5 Keypad Entry 12 0001-9999 9 1-8, (optional)* Press Operation Add PINs (Make sure Option 40 is set on PIN and Prox Units) 4-6 digit PIN code Enable Arming mode (make sure Option 42 is set) Select each door this PIN is valid for End
To summarise, the following steps are required for setting up tokens to arm and disarm alarm panels: 1. Program the ACTSmart2 to be an Arming Door - Option 42 On 2. Assign a card or PIN with the Arming function - see above. 3. Assign an Aux I/O as the Door Armed output - I/O Function Code 14 4. If required, turn the Pulse Door Armed Option on - Option 43 On 5. If required, assign an input as the Panel Armed input. This input verifies when the alarm panel is actually armed. - I/O Function Code 15 6. Connect up according to the Alarm Panel wiring diagram.
12
ACTSmart2 Operating and Installation Manual
Rev. 1.1
Programming ACTSmart Options:
Step 1 2 3 4 Option 30 31 Keypad Entry 30-43 0 or 1 1-8, (optional)* Press Function Door Chime Silent Operation Operation Select Option Number 0 = Off, 1 = On Select each door this option is set for End setting options Default Off Off Operation When set, whenever the door contact is opened, the built-in buzzer makes a chime sound and the buzzer output activates for 2 seconds When set, the keypad operates silently. No audible tones (key-presses or confirm tones) are produced from the built-in buzzer When set, and when the door relay is active (following a valid code or button release), the door relay timer is truncated to 2 seconds when the door contact opens. This ensures that the door will be locked as soon as it closes, and any person following will have to enter a PIN or present a card. When set, the door relay toggles for each valid entry. The green LED flashes when the door is toggled open. When set, the buzzer output / door alarm output is activated if the door contact opens when the door is locked. The output is deactivated when a valid card or PIN is next entered. This is useful for monitoring fire doors etc. When set, and the door contact has been open for longer than the time programmed into the door ajar timer, the buzzer output / door alarm output is activated. Closing the door and presenting a valid card or entering a valid PIN deactivates the output. When set, (default) and when the key on the keypad is pressed, the buzzer output is activated for the duration programmed in the guest buzzer timer. When set, and when a duress PIN is entered, the door is opened normally and the Door Alarm output activated. A duress PIN is any valid PIN with one added to the last digit. The output will be reset when a valid user enters. When the duress option is set, avoid using PINs that are different by 1. Set one device on the network to be the Master. When set, only Card and PIN users are admitted. This is only valid for ACTSmart PIN and Prox units. When set, either a valid Card or valid PIN will open the door. This is only valid for ACTSmart PIN and Prox units. In this mode, a valid card and any valid PIN code will open the door. This is only valid for ACTSmart PIN and Prox units. This mode allows all users to have a common PIN code to use with their cards. In this mode, users with the Arm option can switch an output to signal to an Alarm panel to arm/disarm (See I/O function code 14). When set, the Door Armed output will pulse for 2 seconds to signal arm and disarm. (See I/O function 14). 13
32
Lock-saver (Anti Tailgating)
Off
33 34
Toggle Door Forced Alarm
Off On
35
Door Ajar Alarm
On
36
Guest Button
On
37
Duress Codes
Off
38 39 40 41
Network Master Card and PIN Card or PIN Card and any PIN
Off Off Off Off
42 43
Arming Door Pulse Door Armed
Off Off
ACTSmart2 Operating and Installation Manual
Rev. 1.1
Setting Programmable Input Function:
Step 1 2 3 4 Keypad Entry 50 0-6 1-8 (optional)* Press Operation Set Input Function (Door Release button is default) Select I/O Function Code (see below for explanation of codes) Select each door this function is valid for End programming Input Function
Setting AUX I/O 1 Function:
Step 1 2 3 4 Keypad Entry 51 00-19 1-8 (optional)* Press Operation Set AUX I/O 1 Function (Door Contact is default) Select 2-digit I/O Function Code (see below) Select each door this function is valid for End programming AUX I/O 1
Setting AUX I/O 2 Function:
Step 1 2 3 4 Keypad Entry 52 00-19 1-8 (optional)* Press Operation Set AUX I/O 2 Function (Door Alarm is default) Select 2-digit I/O Function Code (see below) Select each door this function is valid for End programming AUX I/O 2
I/O Function Codes:
Code 0 1 Function Door Contact Fire Alarm Override Operation Input required if you wish to monitor Door Forced or Door Ajar When this input is high, the door is opened and the green LED flashes (See Fire Alarm Override Connections diagram). If this is wired into the Master Smart, then all doors on the network will open. When this input is low, the door locks and the red LED flashes. When this input is low, then only users who enter both Card and PIN will be admitted. This option is only valid on an ACTSmart PIN and Prox. When this input is low, a valid Card or a valid PIN will open the door. This option is only valid on an ACTSmart PIN and Prox. When this input is low, the door opens. When this input is low, any I/Os configured as Second Door Lock will open for the Door Lock Time. This normally behaves as an input and locks the door while the input is low. While the door relay is active or the Door Contact is open, it becomes an active output. (See Interlock Connections diagram). This output activates while an alarm is present - A door alarm may be a door forced, door ajar, tamper or duress. This output follows the state of the door relay. This output activates for Door Chime or Door Alarms. This output controls a SmartLock device for Secure doors. This output will activate for the Door Lock Time when a valid card or PIN is presented. See commands 70-73. continued 14
2 3 4 5 6 7
Lock Door Card and PIN Card or PIN Door Release Button Second Door Release Button Interlock
8 9 10 11 12
Door Alarm Follow Buzzer SmartLock Second Door Lock
ACTSmart2 Operating and Installation Manual
Rev. 1.1
I/O Function Codes
Code 14 Function Door Armed
(continued) Operation This output toggles when a user with the armed function presents a valid card or PIN. This can be used to arm or disarm an alarm panel. The output may be set to pulse for 2 seconds instead of toggle. See Option 43. When this input is low, the door is locked and the red LED flashes. This input informs the ACTSmart2 that the panel is armed. (See the Alarm Panel Wiring diagram). This output follows the state of the green LED. This ouput follows the state of the red LED.
15
Panel Armed Input
18 19
Green LED Red LED
Quick IO Setup:
Step 1 2 Keypad Entry 53 0-9 0 1 2 3 4 5 61 7 8 9 3 4
1
Operation Set Input Output Functions (0 - is default) Select a code Prog Input Door Release Button Door Release Button Door Release Button Door Release Button Door Release Button Door Contact AUX IO 1 Door Contact Door Contact Door Contact Door Contact Fire Override Follow AUX IO 2 Door Alarm Buzzer Interlock SmartLock Interlock Door Alarm Door Armed Buzzer Buzzer Follow
1-8 (optional)* Press
Data Clock Door Contact Door Alarm Fire Override Interlock Card And PIN Interlock Select each door this function is valid for End Quick IO setup
The Quick IO setup allows the ACTSmart2 unit to be connected to the ACTPro family of Clock and Data readers (code number 6). This feature allows an ACTPro reader to be installed on the non-secure side of the door and the ACTSmart2 to be inside the secure area. This prevents tampering with the lock relay from the outside. See the ACTPro Connections diagram.
Adding a Card Batch for Second Door:
Step 1 2 3 4 5 Keypad Entry 70 Present Card Present Card Enter 1-8, (optional)* Press Operation Add Card Batch for Second Door (I/O function code 12 must be set for the Aux O/P) First card in Batch (lowest number card) Last Card in Batch (highest number card) Select each door this batch enabled for End programming card batch. Note: the buzzer will sound while cards are loaded into memory.
15
ACTSmart2 Operating and Installation Manual
Rev. 1.1
Adding a PIN for Second Door:
Step 1 2 3 4 Keypad Entry 71 0001-9999 1-8, (optional)* Press Operation Add PINs (Make sure Option 40 is set on PIN and Prox units.) (I/O function code 12 must be set for the Aux O/P)
4 - 6 digit PIN code Select each door this PIN is valid for End programming PINs
Adding a Card and PIN for Second Door:
Step 1 2 3 4 5 Keypad Entry 72 Present Card 0001-9999 1-8, (optional)* Press Operation Add Card and PIN (Make sure Option 39 is set on PIN and Prox units.) (I/O function code 12 must be set for the Aux O/P)
4 - 6 digit PIN code Select each door this Card & PIN is valid for End programming Card and PINs
Add Random Card for Second Door:
Step 1 2 3 4 5 6 Keypad Entry 73 Enter 1-8, (optional)* Press Present Card Present Card (optional)* Press Operation Add random card for Second Door (I/O function code 12 must be set for the Aux O/P) Select each door these cards enabled for Add card Repeat for all other cards to be added End adding cards
16
ACTSmart2 Operating and Installation Manual
Rev. 1.1
Programming a Network System
Up to 8 ACTSmart devices can be connected on the network. See the ACTSmart Network Installation diagram to complete the necessary connections.
Programming Door Numbers
To allow some users through a door and prevent access to other users, each ACTSmart on the network must be given a door number (1-8). An ACTSmart Proximity Only Unit requires a door number if it is to be programmed with advanced options.
Set a Master
Set one device on the network to be the Master. This device will be used for programming the entire network and should be a PIN and Prox unit. The Master is automatically assigned door number 1. The other ACTSmarts on the network (door numbers 2-8) are referred to as Slave Units. No programming is allowed on a Slave (except to default it - see Restoring Factory Defaults). Enter programming mode. Press buttons 3,8 followed by 1 to set the device to be the Master. The rest of the units on the network are assigned door numbers by following the procedure below:
Assign Door Numbers:
Step 1 2 Keypad Entry 60 Operation Assign Door Numbers Any ACTSmart units without a door number start to beep. The number of beeps is determined by the door number to be programmed. Eg. If door 5 is to be programmed, all unassigned ACTSmarts will beep 5 times. Present card or press key on Slave Press on Master This operation should take place on the desired door number. The ACTSmart stops beeping. Repeat step 2 until all ACTSmarts have been assigned a door number. End programming door numbers
3 4 5
Assigning Users to Doors
When each ACTSmart has been given a unique door number, then users may be given access through specific doors. In most programming menus, there is an optional step to program specific doors. For example, when programming a Card Batch, the user may select which doors the Card Batch applies to (Step 4 in Adding Card Batch, see above). Skip this optional step if programming is to apply to all doors on the network.
Checking Network Programming
The door number of any ACTSmart on the network can be found using the menus below. This is a useful check to perform to verify communications from the Master to the Slave units and to check that the Door Numbers have been assigned correctly.
17
ACTSmart2 Operating and Installation Manual
Rev. 1.1
Find Door Number:
Step Keypad Entry 1 61 2 1-8 3 Press a key or present a card Operation Find Door Numbers Enter the door number to be found. The ACTSmart assigned the door number starts to beep. To stop the ACTSmart beeping.
Find All Door Numbers:
Step 1 2 3 Keypad Entry 62 Press Press key or present card at each ACTSmart Operation Find Door Numbers Each ACTSmart beeps their door number To stop the ACTSmart Beeping
Adding a Slave to the Network
Another Slave can be added to the network by defaulting it first (see below) and then assigning it a door number from the Master.
Removing a Slave from the Network
To remove a Slave unit from the network, simply disconnect it from the network.
Replacing a Slave Unit
To replace a Slave Unit, remove the old Slave from the network. Default the new Slave and add it to the network. Assign a door number to it from the Master.
Replacing the Master Unit
If the Master Unit needs to be replaced, then replace it with a Slave unit already on the system, (as it will have all the card/PIN information), and make it the Master. Add a new, defaulted Slave to the network in place of the swapped-out Slave. Then assign a Door numbers to the new Slave - make sure it is the Door number of the old Slave.
Restoring Factory Defaults
Enter Programming code followed by 80 followed by . If this is done on the Master ACTSmart then all ACTSmarts on the network are defaulted (including the Master). If it is done on a Slave then only the Slave is defaulted. If the programming code has been forgotten, power up with the tamper open (by removing the main unit from the mounting plate or the surface mount collar), while holding down the key. Release the key and then enter the default Programming Code (9999). Defaulting memory takes 3-4 seconds. During this time, the buzzer will sound an elongated tone.
18
ACTSmart2 Operating and Installation Manual
Rev. 1.1
Programming ACTSmart Prox Only (1070)
To program an ACTSmart Prox Only device, a Programming Card must be assigned to the ACTSmart. The Programming Card may be any proximity card. If you have received a batch of cards, use the first (lowest numbered) card in the batch as the Programming Card. To set the Programming Card into the ACTSmart Prox do the following: 1. Power up the device with the tamper open (by removing the main unit from the mounting plate or the surface mount collar), 2. Present the card to the reader. The reader will beep. 3. Take the card away from the reader for 1 second (more than 20 cm) 4. Present the card to the reader again. The reader will beep. 5. The card is now set as the Programming card. (Note: ACT recommends using an ACTSmart PIN and Prox device if a network is required). In the steps below, after a card is presented to the reader it must be taken away from the reader (more than 20cm) for 1 second before presenting the card again.
Adding a Card Batch to the Network:
Step 1 2 3 Present Programming Card Present Card Present Card Operation Add Card Batch First card in Batch First card in Batch
Deleting Batch Cards to the Network
Step 1 2 3 4 Present Programming Card Programming Card Present Card Present Card Operation Delete Card Batch First card in Batch to delete First card in Batch to delete
Deleting Individual Card (Require Card Above):
Step 1 2 3 4 Present Programming Card Programming Card Programming Card Present Card Operation
Delete Individual Card Card above the card that needs to be deleted e.g. if card number 99 needs to be deleted, present card number 100
Programming the Door Relay Time:
Step 1 2 3 4 5 Present Programming Card Programming Card Programming Card Programming Card Programming Card Operation
Wait for 4 seconds, Buzzer sounds indicating timing... wait required period. Buzzer stops - timer set.
19
ACTSmart2 Operating and Installation Manual
Rev. 1.1
Programming for SmartLock:
Step 1 2 3 4 5 6 Present Programming Card Programming Card Programming Card Programming Card Programming Card Programming Card Operation
Buzzer sounds intermittently and the LED flashes Input 1 = Door Contact, AUX I/O 1 = Door Alarm, AUX I/O 2 = SmartLock. See the SmartLock Connections diagram.
Default ACTSmart:
Step 1 2 3 4 5 Present Programming Card Programming Card Programming Card Programming Card Programming Card Present Card (Not Programming Card) Operation
Buzzer sounds intermittently and the LED flashes RED to warn you are about to default the system Default ACTSmarts. Note: This deletes the Programming Card.
20
ACTSmart2 Operating and Installation Manual
ACTSmart Standalone Installation Diagram
21 Rev. 1.1
Access Control Technology, Unit 8, Tallaght Business Park, Whitestown, Dublin 24, Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587 Web: http://www.accesscontrol.ie E-mail: sales@accesscontrol.ie
ACTSmart2 Operating and Installation Manual
ACTSmart Fire Alarm Override Connections
22
ACTSmart Interlock Connections
Rev. 1.1
Access Control Technology, Unit 8, Tallaght Business Park, Whitestown, Dublin 24, Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587 Web: http://www.accesscontrol.ie E-mail: sales@accesscontrol.ie
ACTSmart2 Operating and Installation Manual
ACTSmart Network Installation Diagram
23 Rev. 1.1
Access Control Technology, Unit 8, Tallaght Business Park, Whitestown, Dublin 24, Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587 Web: http://www.accesscontrol.ie E-mail: sales@accesscontrol.ie
ACTSmart2 Operating and Installation Manual
Rev. 1.1
SmartLock Connection Diagram
Access Control Technology, Unit 8, Tallaght Business Park, Whitestown, Dublin 24, Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587 Web: http://www.accesscontrol.ie E-mail: sales@accesscontrol.ie
24
ACTSmart2 Operating and Installation Manual
ACTSmart Alarm Panel Wiring Diagram
25 Rev. 1.1
Access Control Technology, Unit 8, Tallaght Business Park, Whitestown, Dublin 24, Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587 Web: http://www.accesscontrol.ie E-mail: sales@accesscontrol.ie
ACTSmart2 Operating and Installation Manual
ACTPro Connections Diagram
26 Rev. 1.1
Access Control Technology, Unit 8, Tallaght Business Park, Whitestown, Dublin 24, Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587 Web: http://www.accesscontrol.ie E-mail: sales@accesscontrol.ie
ACTSmart2 Operating and Installation Manual
2 Door Wiring Diagram
27 Rev. 1.1
Access Control Technology, Unit 8, Tallaght Business Park, Whitestown, Dublin 24, Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587 Web: http://www.accesscontrol.ie E-mail: sales@accesscontrol.ie
ACTSmart2 Operating and Installation Manual
ACTSmart System Diagram
28 Rev. 1.1
Access Control Technology, Unit 8, Tallaght Business Park, Whitestown, Dublin 24, Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587 Web: http://www.accesscontrol.ie E-mail: sales@accesscontrol.ie
ACTSmart2 Operating and Installation Manual
ACTSmart Mounting Instructions for Flush-Mount Unit
29 Rev. 1.1
Access Control Technology, Unit 8, Tallaght Business Park, Whitestown, Dublin 24, Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587 Web: http://www.accesscontrol.ie E-mail: sales@accesscontrol.ie
ACTSmart2 Operating and Installation Manual
ACTSmart Mounting Instructions for Surface Mount Unit
30 Rev. 1.1
Access Control Technology, Unit 8, Tallaght Business Park, Whitestown, Dublin 24, Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587 Web: http://www.accesscontrol.ie E-mail: sales@accesscontrol.ie
Smart
access control TECHNOLOGY
User List
User Name
Card Number
PIN
Doors 1 2 3 4 5 6 7 8
Access Control Technology, Unit 8, IDA Business Park, Whitestown, Dublin 24, Ireland. TEL:353-1-4622585 FAX: 353-1-4622587 WEB: http://www.accesscontrol.ie E-MAIL: sales@ accesscontrol.ie
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ACT ACTSMART 2 PRODUCT RANGE. ACT offer a product for which we do not have the user manual? Let us know what you are looking for: user guide, owner's manual, online manual, operating instructions, quick start guide, mounting instructions, schematics, service manual, installation instructions, RTFM. Diplodocs allows you to download user manual ACT ACTSMART 2 PRODUCT RANGE, user guide ACT ACTSMART 2 PRODUCT RANGE, instructions ACT ACTSMART 2 PRODUCT RANGE, owner's manual ACT ACTSMART 2 PRODUCT RANGE, online manual ACT ACTSMART 2 PRODUCT RANGE.ACT ACTSMART 2 PRODUCT RANGE, , Software. |
![]() |
Include the add-on to download manuals from your site, forum or blog | ![]() |
Frequently Asked Questions | ![]() |
Contact Diplodocs team | ![]() |
Last searches Last additions |
![]() |
Sitemap | ![]() |
|||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |