DISCLAIMER TO DOWNLOAD THE USER GUIDE ADVANTOR ADVANTAGE PLUS - BASE MODULE

Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ADVANTOR ADVANTAGE PLUS - BASE MODULE will begin.

You agree to use the Manual in accordance with the terms and conditions hereafter described.

1. Our service
Diplodocs offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...

2. Access rights
The documents available on this site are and will remain properties of their respective owners. Accessing, downloading or storing a document on this site does not give you any right. You certify accessing and storing only documents for which you regularly acquired rights of use, either by owning the item corresponding to the document, or thanks to a right to broadcast the document, given by the copyright owners.

3. Our responsibility
In any way can't Diplodocs be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Diplodocs, for instance, does not offer a translation service.

4. Checking of use
Once downloaded, you must make sure that the Manual matches the Product for which you intend to use it. You agree to remain entirely responsible for the use you do with the instructions contained in the document, no matter whether damages of losses occur following its use.

5. Your commitment
In compensation for using our service, you certify not to harm Diplodocs by any legal action, and to help Diplodocs by promoting the site or uploading new documents. You acknowledge that Diplodocs does not owe you mandatory results or availability.


Diplodocs explicitly forbids the use of its service by anyone who do not agree with all conditions above. By accepting or downloading the Manual ADVANTOR ADVANTAGE PLUS - BASE MODULE, you agree to have read the disclaimer, to have understood all of it and to be bond by its terms and conditions.

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.

   

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

We hope that this ADVANTOR ADVANTAGE PLUS - BASE MODULE user guide will be useful to you.

Need help, support, reviews, tips or troubleshooting for your ADVANTOR ADVANTAGE PLUS - BASE MODULE products ?
Discussion, review, tips, troubleshooting issue, problem : search help on ADVANTOR ADVANTAGE PLUS - BASE MODULE product forum.



close

5 364 brands
1 237 233 user's guides
520 000 members
Domestic Appliance | TV & Audio | Phone | Computer | Car | Digital Camera | Video Game
Search
a brand
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # Search for a user manual
 

User manual ADVANTOR ADVANTAGE PLUS - BASE MODULE

Diplodocs help download the user guide ADVANTOR ADVANTAGE PLUS - BASE MODULE.

  Download the user manual ADVANTOR ADVANTAGE PLUS - BASE MODULE     
Download the complete
user guide (1144 Ko)
Need help, support, reviews, tips or troubleshooting for your ADVANTOR ADVANTAGE PLUS - BASE MODULE products ?




You may also download the following manuals related to this product:

ADVANTOR ADVANTAGE PLUS - BASE MODULE INSTALLATION INSTRUCTIONS

Preview of the first 3 pages of manual
You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.




Visit ADVANTOR official site


User guide ADVANTOR ADVANTAGE PLUS - BASE MODULE


Base Module The Advantage® plus Base Module is the primary communication processor and control unit for Advantage plus systems. Installed within the protected facilities, it is available in a standard UL version, attack version, or a military J-SIIDS version. It interfaces with all other optional modules and devices, and provides communication with the Advantor integrated monitoring system to transmit and display all security messages from the facility. It also includes listen back audio verification for up to four audio inputs. Dimensions Standard UL Enclosure · 17.25" W x 14.5" H x 3.25" D ( 43.82cm x 36.83cm x 8.26cm) · 20 gauge cold rolled steel with lock and key · Color: Light gray w/ Advantor logo Attack-Rated UL Enclosure · 17.25" W x 14.5" H x 3.25" D ( 43.82cm x 36.83cm x 8.26cm) · 18 gauge cold rolled steel with lock and key · Color: Light gray w/ Advantor logo PCB Foot Print · 8.5" W x 7.54" H (21.59cm x 19.15cm) J-SIIDS Compatibility · Direct replacement for current J-SIIDS applications · PCB is a replacement for the current transmitter and processor in conversions shown AVR PLUS BASE-C shown Alarm Points · 16 programmable, supervised, hard-wired points · N/C, N/O, or Both (dry contacts) · Programmable alarm codes · Assignable to any of 8 separate arming partitions (protected areas) · All alarm points operate normally under ground fault conditions · Expandable to a total of 144 points with Expansion Modules & another 63 points with the Wireless Module Transmission Media Dedicated · UL Grade AA, upgradeable to DES Class A · Supervision for Compromise, and Failure Dial Pulse or DTMF dialing Integrated cut line supervision RJ31X jack connection Secondary dial line capability with optional TelPlus Module · Secondary cellular communication with optional Cellular Module · Optional Telco "Level 2" Surge Protection · · · · Local Annunciation · Local bell drive: 12V at 1.25 Amp maximum · Audible keypad beeper Audio · Four balanced audio inputs supporting four verification audio sensors or any combination of up to eight optional SmartAudio or ListenIn Modules for up to 128 audio inputs. Arm/Disarm Function (Secure/Access) · 16 keypads · 8 partition capability · Programmable switch arming via momentary contact closure · Programmable access card arming via integrated card reader input (wiegand) · Programmable arm/disarm functions · Single key arming · Non-reporting · Reporting · Arm at shift · Optional SCIF package Wiegand Input · Interfaces with one card reader or biometric device for secure, user-friendly arm/ disarm of security and access control verification for up to 100 users. Access Modules may be added to the system to extend the capabilities to upto 10,000 users. 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859.3350 · Fax: 407/859.5205 http://www.advantor.com P/N 09820481, Rev. A 6/98 Specifications and part numbers are subject to change without notice. Downloaded from - http://www.guardianalarms.net Operating Environment · 0° F to 122° F (-18° C to 50° C) Communications Central Station · 300 Baud asynchronous, full duplex · Secure Protocol Communication · Transmit: 1070/1270 Hz/Receive: 2025/2225 Hz, FSK Auxiliary Outputs · Four, 100mA, programmable hard-wired · Expandable to 36 total with Loop Expansion Modules Base Module RS-485 Port · Communication link: 2,000 feet maximum using 22AWG, shielded twisted pair cable · Supports a maximum of 40 RS-485 devices, to include: · 16 total keypads · 8 Expansion Modules · 8 SmartAudio or ListenIn Modules in any combination · 1 Wireless Module · 7 Access Modules Primary Power Options · 100 to 120 VAC, 60Hz, using 16.5 VAC, 50VA, Class 2 plug-in transformer · 100 to 120 VAC, 50- 60Hz with internal transformer · 200 to 240 VAC, 50-60Hz with internal transformer · Can utilize existing J-SIIDS Power Supply · Optional AC "Level 2" Surge Protection Secondary Power · 12VDC, 7AH, sealed lead-acid rechargeable batteries (1 or 2, depending on kit) · Internal battery charger · Backup capabilities 12 to 24 hours typical (depending upon installed equipment) · Integral battery supervision for AC power loss, low battery and battery trouble Approvals · FCC Part 15, Class B · UL 294, "Access Control System Units" (using optional Access Module) · UL 365, "Police Connected Burglary" · UL 609, "Local Burglary" · UL 864, "Control Units for Fire Protective Signaling Service" · UL 985, "Household Fire Warning System Units" · UL 1023, "Household Burglar-Alarm Systems" · UL 1076, "Proprietary Burglar Alarm Units and Systems" · UL 1610, "Central Station Burglar Alarm Units" · Communicator for UL 611, "Central Station Burglary" · CSFM (California State Fire Marshal) · ULC Commercial Fire and Burglary Pending Auxiliary Power · 1.6 Amps continuous at 12VDC (plug-in transformer) · 1.3 Amps continuous at 12VDC (internal transformer) · 1.0 Amps continuous at 12VDC (JSIIDS power supply) Part Numbers AVR PLUS BAS Complete Base Kit, Standard enclosure, wall-mount transformer AVR PLUS BAS-C Complete Base Kit, standard enclosure, internal transformer (120VAC), (AC "Level 2" and telco "Level 2" dedicated line surge protection) AVR PLUS BAS220 Complete Base Kit, 220 VAC, Standard enclosure, internal transformer, (AC "Level 2" and telco "Level 2" dedicated line surge protection) AVR PLUS BAS220AT Complete Base Kit, 220VAC, Attack enclosure, internal transformer, AC "Level 2" and telco "Level 2 dedicated line surge protection AVR PLUS BAS-J JSIIDS Upgrade Kit, with AC "Level 2" and telco "Level 2 dedicated line surge protection AVRPLUSBASCELKT Factory integrated Base Module and Cellular Module, assembled in attack enclosure, with 120 VAC internal transformer. Includes AC "Level 2" surge protection and dial phone line "Level 2" surge protection AVR PLUS Complete Base Kit, Standard enclosure with SmartAudio module, wallmount transformer, 120VAC PCB, Base Module, UL Installation Connector Kit JSIIDS Installation Connector Kit Standard Enclosure with Lock & Key Attack Enclosure with Lock and Key Transformer, 16.5VAC, 50VA, Plug-In AC "Level 2" Surge Protector (120VAC) hardwired AC "Level 2" Surge Protector (220VAC) hardwired Telco "Level 2" Dedicated Line Surge Protector, hardwired Telco "Level 2" Dial Line Surge Protector, hardwired AC "Level 2" Surge Protection for plug-in transformer Base Module Installation Instructions Enclosure Tamper Switch Kit Battery, 12V, 7 AH, Gel Cell 90225102 40013701 40012810 90237200 90258200 08610416 08061699 08061431 08061698 08060085 08060084 09820450 40003401 08061206 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859.3350 · Fax: 407/859.5205 http://www.advantor.com Specifications and part numbers are subject to change without notice. SmartAudio Module Adds audio detection capability to the Advantage® plus system, while screening out many common environmental sounds. Continuously scans its audio channels, and analyzes sounds according to a predetermined set of audio algorithims or patterns. If a noise is determined to be a possible intrusion, the monitoring console is contacted. When a sound is deemed environmental, there is no call to the central station. Each Base Module can interface and control up to 8 SmartAudio or ListenIn Modules. Dimensions PCB Foot Print · 7.25" W x 8.5" H (17.41cm x 21.59cm) Audio · DSP processes 8 audio channels for intrusion detection · Each audio channel assignable to any of 8 separate arming partitions · Sensitivity adjustable from central station · 16 audio sensor inputs (two per audio channel) · Programmable audio sensor self-test at system arming and disarming · Balanced audio output to Base Module · Audio sensors annunciate Chime Mode & Entry/Exit Alert Stored Audio · One second pre-impact · Four seconds post-impact, followed by live audio Power Requirements · 200 mA at 12 VDC (from Base Module or optional APS12V1A-S Advantage PowerSource) Operating Environment · 0° F to 122° F (-18° C to 50° C) Communications · Base Module RS-485 Communication link up to 2,000 feet maximum with 22AWG shielded twisted pair cable Auxiliary Inputs · "No AC" and "Low Battery" inputs to monitor the status of an optional APS12V1A-S Advantage PowerSource · Tamper input Mounting · Mounts locally inside Base Module enclosure or remotely inside optional enclosure up to 2,000 ft. from Base Module Part Numbers ADV SAM Smart Audio Module with Installation Kit APS12V1A-S Power Supply, 12VDC AVR CHAS/SUR115 Standard Enclosure, Internal Transformer (120VAC) and AC "Level 2" surge protection AVR CHAS/SUR220 Standard Enclosure, Internal Transformer (220VAC) and AC "Level 2" surge protection 40003401 Enclosure Tamper Switch Kit 90228102 90237200 90258200 08610416 09820452 PCB, Smart Audio Module Standard Enclosure with Lock and Key Attack Enclosure with Lock and Key Transformer, 16.5VAC, 50VA, Plug-In SmartAudio Module Installation Instructions 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859.3350 · Fax: 407/859.5205 http://www.advantor.com P/N 09820486, Rev. A 6/98 Specifications and part numbers are subject to change without notice. BLANK 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859.3350 · Fax: 407/859.5205 http://www.advantor.com Specifications and part numbers are subject to change without notice. Expansion Module The Expansion Module provides the Advantage® plus Base Module with an additional 16 supervised, programmable alarm points, and four additional auxiliary outputs. Each Base Module can interface and control up to 8 Expansion Modules. Dimensions PCB Foot Print · 6.87" W x 4.125" H (17.45cm x 10.48cm) Alarm Points 16 programmable, supervised, hard-wired points N/C, N/O, or Both (Dry Contact) Programmable alarm codes Programmable into any of 8 separate arming partitions(protected areas) · All alarm points operate normally under ground fault conditions · · · · Operating Environment · 0° F to 122° F (-18° C to 50° C) Auxiliary Outputs · Four, 100mA, programmable hard-wired Communications · Base Module RS-485 Communication link up to 2,000 feet maximum with 22AWG shielded twisted pair cable Power Requirements · 12 VDC (from Base Module or optional APS12V1A-S Advantage PowerSource) · 130mA maximum in both Normal Standby and Alarm Mounting · One mounts locally inside Base Module enclosure or remotely inside an optional enclosure up to 2,000 feet from the Base Module Part Numbers Loop Expansion Module with Installation Kit APS12V1A-S Power Supply, 12VDC 90226101 PCB, Expansion Module 90237200 Standard Enclosure with Lock and Key AVR CHAS/SUR115 Standard Enclosure, Internal Transformer (120VAC) and AC "Level 2" surge protection AVR CHAS/SUR220 Standard Enclosure, Internal Transformer (220VAC) and AC "Level 2" surge protection ADV LEM 40003401 90258200 08610416 09820453 08061699 08061431 08061206 Enclosure Tamper Switch Attack Enclosure with Lock and Key Transformer, 16.5VAC, 50VA, Plug-In Loop Expansion Module Installation Instructions AC Surge Protector (120VAC), hardwired AC Surge Protector (220VAC), hardwired Battery, 12V, 7AH Gel Cell 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859.3350 · Fax: 407/859.5205 http://www.advantor.com P/N 09820483, Rev. A 6/98 Specifications and part numbers are subject to change without notice. BLANK 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859.3350 · Fax: 407/859.5205 http://www.advantor.com Specifications and part numbers are subject to change without notice. Access Module The Access Module adds access control to the Advantage® plus system. Each Base Module can interface and control up to seven Access Modules with each module controlling four card readers. General Features · Access for up to 10,000 cardholders, with 256 Access Levels · 128 programmable Time Shifts & Time Periods per property · Optional Anti-Passback, either local or global · Programmable outputs to control equipment, such as HVAC and lighting · Distributed Processing system with 8,000 event local buffer memory · Optional Free Exit or Card Controlled exit · Compatible with most card types · Weigand · Proximity · Magnetic stripe · Bar Code · Level 1 (card only); Level 2 (card plus PIN) or Level 3 (card, PIN and biometrics) capability. Dimensions Standard UL Enclosure · 17.25" W x 14.5" H x 3.25" D ( 43.82cm x 36.83cm x 8.26cm) · 20 gauge cold rolled steel with lock and key · Color: Light gray w/ Advantor logo Attack-Rated UL Enclosure · 17.25" W x 14.5" H x 3.25" D ( 43.82cm x 36.83cm x 8.26cm) · 18 gauge cold rolled steel with lock and key · Color: Light gray w/ Advantor logo PCB Foot Print · 12.75" W x 8.75" H (32.39cm x 22.23cm) shown ACCESS 4-A KIT shown Alarm Points · 14 programmable, supervised, hard-wired points · N/C, N/O, or Both (dry contacts) · Four programmable door inputs · 10 programmable, general purpose, alarm inputs · One tamper input (alarm-on-open only) · One global free-exit input (for fire evacuation) · Programmable alarm codes · Assignable to any of eight separate arming partitions (protected areas) Auxiliary Outputs · Six, 100mA, programmable hard-wired · One auxiliary output per controlled door (four total) · Two auxiliary outputs for general control · Optional RMOD (Relay Module) · 4 RMODS per Access Module · 8 relays per RMOD · Controlled by shift or user groups Operating Environment · 0° F to 122° F (-18° C to 50° C) Primary Power · 100 to 120 VAC, 60Hz, using 16.5 VAC, 50VA, Class 2 plug-in transformer · 100 to 120 VAC, 50-60Hz with enclosure mounted transformer · 200 to 240 VAC, 50-60Hz with enclosure mounted transformer · Optional AC "Level 2" Surge Protection 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859.3350 · Fax: 407/859.5205 http://www.advantor.com P/N 09820482, Rev. A 6/98 Specifications and part numbers are subject to change without notice. Secondary Power · Two, 12 VDC, 7 AH, sealed lead-acid rechargeable batteries · Internal battery charger · Backup capabilities 2 to 6 hours typical (depending upon equipment) Communications Access Module RS-485 Port · Communication link: 2,000 feet maximum with 22AWG shielded twisted pair cable · Supports a maximum of 40 optional RS-485 devices Auxiliary Power · 12 VDC at 0.9 Amps continuous for external equipment · 12 VDC at 1.0 Amp for door locks Approvals · FCC Part 15, Class B, Part 68 · UL 294, "Access Control System Units" Part Numbers ACCESS 4-A ACCESS 4-A KIT Complete Access Kit, standard enclosure, plug-in transformer Complete Access Kit, standard enclosure with internal transformer(120VAC), and AC "Level 2" Surge Protection Complete Access Kit, 220VAC, standard enclosure, internal transformer Complete Access Kit, 220VAC, attack enclosure, internal transformer, and AC "Level 2" Surge Protection PCB, Access Module 90237200 90258200 08610416 09820451 RMOD-A 08061699 08061431 08061206 Standard Enclosure with Lock and Key Attack Enclosure with Lock and Key Transformer, 16.5VAC, 50VA, Plug-In Access Module Installation Instructions Relay Module for 8 additional relay outputs AC Surge Protector (120VAC), hardwired AC Surge Protector (220VAC), hardwired Battery, 12V, 7AH, Gel Cell INT ACCESS 4-A INT ACC-4-AT 90212153 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859.3350 · Fax: 407/859.5205 http://www.advantor.com Specifications and part numbers are subject to change without notice. Cellular Module The Cellular Module allows the Advantage® plus Base Module to communicate with the monitoring console via cellular communications. This can be used to provide security in situations where phone lines are unavailable, or to provide backup communication if regular phone service is interrupted. Dimensions PCB Foot Print · 11.00" W x 8.0" H (27.94cm x 20.32cm) Cellular Interface · Motorola 3 watt, full duplex unit · Communication with cell constantly monitored · Cable length to antenna is 15 feet Operating Environment · 0° F to 122° F (0° C to 50° C) Power Requirements · 12 VDC from Base Module backup battery(s) · 100mA in Normal Standby mode · 1,600 mA in transmit mode Mounting · Mounts locally inside Base Module enclosure Part Numbers CELLULAR MODULE APS12V1A-S 09820457 90194102 AVRPLUSBASCELKT Cellular Module Complete with Installation Kit Power Supply, 12VDC Cellular Module Installation Instructions PCB, Cellular Interface to Base Module Factory integrated Base Module and Cellular Module, assembled in attack enclosure, with 120 VAC internal transformer. Includes AC "Level 2" surge protection and dial phone line "Level 2" surge protection shown AVR PLUSBASECELLKT shown AVR PLUSCELLKT Factory integrated Base Module, Cellular Module, and SmartAudio Module, assembled in attack enclosure, with 120 VAC internal transformer. Includes AC "Level 2" surge protection and dial phone line "Level 2" surge protection 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859.3350 · Fax: 407/859.5205 http://www.advantor.com P/N 09820485, Rev. A 6/98 Specifications and part numbers are subject to change without notice. BLANK 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859.3350 · Fax: 407/859.5205 http://www.advantor.com Specifications and part numbers are subject to change without notice. TelPlus Module For a greater level of security, the TelPlus Module adds a second communication channel, either a dial with line supervision, or a dedicated line to the Advantage® plus system. Dual line capability to meet NFBA 72 4-2.3-2.1.6. Dimensions PCB Foot Print · 2.625" W x 2.125" H (6.67cm x 5.40cm) Telco Configurations Dial Line · RJ31X jack · Pulse or DTMF dialing · Integrated cut line supervision Dedicated Line · RJ31X jack Operating Environment · 0° F to 122° F (-18° C to 50° C) Power Requirements · 12 Volts DC (from Base Module) · 0 mA in Normal Standby mode, 45 mA in transmit mode Part Numbers TEL PLUS 90227101 09820454 TelPlus Module Complete with Installation Kit PCB, TEL PLUS Module TEL PLUS Module Installation Instructions Mounting · Plugs into the J9 connector on the Base Module 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859.3350 · Fax: 407/859.5205 http://www.advantor.com P/N 09820484, Rev. A 6/98 Specifications and part numbers are subject to change without notice. BLANK 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859.3350 · Fax: 407/859.5205 http://www.advantor.com Specifications and part numbers are subject to change without notice. ListenIn Module The ListenIn Module gives the Advantage® plus Base Module the ability to support up to 16 audio verification sensors in any of eight partitions (Advantage AudioSensor or Advantage GlassBreak). Each Base Module can interface and control up to eight ListenIn or SmartAudio Modules. Dimensions PCB Foot Print · 6.87" W x 4.125" H (17.45cm x 10.48cm) Audio · 16 audio sensor inputs · Audio sensor pairs assignable to eight separate arming partitions (protected areas) · Balanced audio output to Base Module Operating Environment · 0° F to 122° F (-18° C to 50° C) Power Requirements · 12 VDC (from Base Module or optional APS12V1A-S Advantage PowerSource) · 30mA in both Normal Standby and Alarm Communications · Base Module RS-485 Communication link up to 2,000 feet maximum with 22AWG shielded twisted pair cable Mounting · One mounts locally inside Base Module enclosure or remotely inside optional enclosure up to 2,000 feet from Base Module Part Numbers ADV LIM APS12V1A-S 90231101 90237200 90258200 08610416 09820455 ListenIn Module with Installation Kit Power Supply, 12VDC PCB, ListenIn Module Standard Enclosure with Lock and Key Attack Enclosure with Lock and Key Transformer, 16.5VAC, 50VA, Plug-In ListenIn Module Installation Instructions AVR CHAS/SUR115 Standard Enclosure, Internal Transformer (120VAC) and AC "Level 2" surge protection AVR CHAS/SUR220 Standard Enclosure, Internal Transformer (220VAC) and AC "Level 2" surge protection 08061699 AC Surge Protector (120VAC), hardwired 08061431 AC Surge Protector (220VAC), hardwired 08061206 Battery, 12V, 7AH Gel Cell 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859.3350 · Fax: 407/859.5205 http://www.advantor.com P/N 09820487, Rev. A 6/98 Specifications and part numbers are subject to change without notice. BLANK 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859.3350 · Fax: 407/859.5205 http://www.advantor.com Specifications and part numbers are subject to change without notice. Wireless Module The Wireless Module gives the Advantage® plus Base Module the capability to interface with up to 63 supervised, programmable alarm points. Each Base Module can interface and control one Wireless Module. Interface · Inovonics 900 MHZ spread spectrum receiver. Dimensions PCB Foot Print · 5.125" W x 2.125" H (13.02cm x 5.40cm) Alarm Points · · · · 63 programmable, supervised, wireless points Optional N/C or N/O Programmable alarm codes Each transmitter assignable to any of 8 separate arming partitions (protected areas) Power Requirements · 12 VDC (from Base Module or optional APS12V1A-S Advantage PowerSource) · 250mA maximum in both Normal Standby and Alarm Supervision · Each wireless transmitter supervised for alarm and battery conditions · Wireless receiver is supervised for communications · Wireless transmitters may be supervised for communications (optional) Communications · Base Module RS-485 Communication link up to 2,000 feet maximum with 22AWG shielded twisted pair cable Operating Environment · 0° F to 122° F (-18° C to 50° C) Mounting · Can be mounted locally inside Base Module enclosure or remotely inside an optional enclosure up to 2,000 feet from Base Module Part Numbers ADV WIM 90239102 APS12V1A-S 90237200 90258200 08610416 09820456 AVR CHAS/SUR115 Wireless Module with Installation Kit PCB, Wireless Module Power Supply, 12VDC Standard Enclosure with Lock and Key Attack Enclosure with Lock and Key Transformer, 16.5VAC, 5A, Plug-In Wireless Module Installation Instructions Standard Enclosure, Internal Transformer (120VAC) and AC "Level 2" surge protection Standard Enclosure, Internal Transformer (220VAC) and AC "Level 2" surge protection AC Surge Protector (120VAC), hardwired AC Surge Protector (220VAC), hardwired Universal Transmitter Door/Window Transmitter (1" Gap) Smoke Detector/Transmitter Pendant Transmitter Sharpshooter PIR/Transmitter DS776RF PIR/Transmitter ShatterPro Glass Break/Transmitter Wireless Billtrap 08061345 08061346 08061347 08061348 08061349 Wireless Billtrap for Metal register Universal transmitter (reduced Size) Door/Window Transmitter (5/8" Gap) Beltclip Transmitter, 2 Button Beltclip Transmitter, 1 Button Remote Wireless Receiver Repeater for Extended Range Box w/four 4.5v Battery Packs for 08061337 Rechargeable 1.2AH, 12v Battery for 08061351 3v Lithium Battery for 08061343 and 08061346 3.6v Lithium Battery for 08061340 and 08061341 Optional holster for Pendant Transmitter Assorted lens pack (5) for 08061341 Pet Alley Lens Pack (5) for 08061341 Mirror for 08061341 installation Ceiling Mount for 08061341 Metal cage for PIR Wireless Survey Kit Receivers 08061350 08061351 08061352 08061353 08061354 08061355 08061356 08061357 08061358 08061359 08061360 08061361 08061362 Accessories and Batteries AVR CHAS/SUR220 08061699 08061431 08061337 08061338 08061339 08061340 08061341 08061342 08061343 08061344 Fully-Supervised Transmitters 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859.3350 · Fax: 407/859.5205 http://www.advantor.com P/N 09820488, Rev. A 6/98 Specifications and part numbers are subject to change without notice. BLANK 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859.3350 · Fax: 407/859.5205 http://www.advantor.com Specifications and part numbers are subject to change without notice. Keypads Advantage LCD plus Keypad Dimensions · Size: 7.75" L x 3.9" W x 0.9" D (19.69cm x 9.91cm x 2.29cm) · Weight: 9.6 oz (272g) · Housing: ABS plastic, off-white Operating Environment · 0° F to 122° F (-18° C to 50° C), non-condensing Power Requirements · · Input Voltage Input Current 10.2 VDC ­ 14 VDC 25 ma - 125 ma programmable 45 ma typical Mounting · Wall mount · Wiring via 13-position Panduit style connector Display · Super Twist LCD · 4 line X 20 characters. · Back lighting with high efficiency LED's Part Numbers LCD PLUS AVR LCD Keypad with Advantor Logo LCD PLUS AVR-RU LCD Keypad with Advantor Logo, Cyrillic version 09004601 Plastic Wall Spacer, 5/16" thick wire entry at top 07917201 Metal Mounting Box with 7/8" knockouts 09004301 Keypad Backplate for mounting to double/triple gang box Keys · Silicone rubber · Key life is greater than 1,000,000 cycles Communications · Base Module RS-485 Communication link up to 2,000 feet maximum with 22AWG shielded twisted pair cable Advantage LED plus Keypad Dimensions · Size: 7.75" L x 3.9" W x 0.9" D (19.69cm x 9.91cm x 2.29cm) · Weight: 9.6 oz (272g) · Housing: ABS plastic, off-white Operating Environment · 0° F to 122° F (-18° C to 50° C), non-condensing Power Requirements · Input Voltage · Input Current 10.2 VDC ­ 14 VDC 25 ma typical, 125 ma maximum Mounting · Wall mount · Wiring via 13-position Panduit style connector Display · Colored LED Display Part Numbers LED PLUS AVR 09004601 07917201 09004301 LED Keypad with Advantor Logo Plastic Wall Spacer, 5/16" thick wire entry at top Metal Mounting Box with 7/8" knockouts Keypad Backplate for mounting to double/triple gang box Keys · Silicone rubber · Key life is greater than 1,000,000 cycles Communications · Base Module RS-485 Communication link up to 2,000 feet maximum with 22AWG shielded twisted pair cable 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859.3350 · Fax: 407/859.5205 http://www.advantor.com P/N 09820490, Rev. A 6/98 Specifications and part numbers are subject to change without notice. BLANK 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859.3350 · Fax: 407/859.5205 http://www.advantor.com Specifications and part numbers are subject to change without notice. Sensors Advantage plus AudioSensor Coverage Information The coverage pattern of the Advantage AudioSensor is basically a heart-shaped envelope. That is, the AudioSensor is most sensitive to sounds directly in front of it, with the sensitivity decreasing at the sides and to the rear. For example, a properly calibrated Advantage AudioSensor mounted on a post in the center of an open room could have a coverage pattern extending approximately 50 feet in front, 40 feet to each side, and 15-20 feet to the rear. NOTE: The stated distances are for reference only and DO NOT establish minimum or maximum coverage areas. The AudioSensor's location, mounting surface, and other environmental conditions determine an actual and workable coverage pattern and distance. Using in a listen-in only application may enhance the coverage area. Power Requirements · Input Voltage: 10.2 VDC ­ 14 VDC · Input Current: 5 ma typical Tamper Switch · 500ma at 30 VDC Mounting · Wall mount · Wiring via 6-position Panduit style connector Dimensions · Size: 3.25" L x 1.68" W x 0.75" D (8.26cm x 4.27cm x 1.91cm) · Weight: 1.56 oz (44g) · Housing: ABS plastic, off-white Part Numbers AUDIOSENSOR 07543002 40013401 AudioSensor Complete PCB, AudioSensor AudioSensor/GBD Backplate to mount to single gang box (package of 6) Ceiling Mounting Bracket Housing Operating Environment · 0° F to 122° F (-18° C to 50° C) 49001501 09001101 Advantage plus GlassBreak Dimensions · Size: 3.25" L x 1.68" W x 0.75" D (8.26cm x 4.27cm x 1.91cm) · Weight: 1.56 oz (44g) · Housing: ABS plastic, off-white Power Requirements · Input Voltage: 10.2 VDC ­ 14 VDC · Input Current: 5 ma typical Operating Environment · 0° F to 122° F (-18° C to 50° C) Tamper Switch · 500ma at 30 VDC Part Numbers GBD-ST 90256100 40013401 49001501 09001101 Glass Break Sensor Complete PCB, Glass Break Sensor AudioSensor/GBD Backplate to mount to single gang box Ceiling Mounting Bracket Housing Mounting · Wall mount · Wiring via 6-position Panduit style connector 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859.3350 · Fax: 407/859.5205 http://www.advantor.com P/N 09820489, Rev. A 6/98 Specifications and part numbers are subject to change without notice.


ADVANTOR ADVANTAGE PLUS - BASE MODULE, , alarm, fire detection, video surveillance, home automation, Safety & Domotic.

Detailed instructions for use are in the User's Guide.

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ADVANTOR ADVANTAGE PLUS - BASE MODULE.

ADVANTOR offer a product for which we do not have the user manual? Let us know what you are looking for: user manual, user guide, instructions, owner's manual, online manual, user's manual, users manual, users guide, owner manual, owners manual, user's guide, handbook, instructions for use, instruction manual, operation manual, operating instructions, installation guide, quick start guide, quikstart guide, getting started, installation instructions, installation guide,mounting instruction, assembly instrucions, fixing instructions, use instruction, schematics, operating manual, feature sheet, data sheet, booklet, service manual, use and care guide, installation manual, installation software, RTFM.

Diplodocs allows you to download user manual ADVANTOR ADVANTAGE PLUS - BASE MODULE, user guide ADVANTOR ADVANTAGE PLUS - BASE MODULE, instructions ADVANTOR ADVANTAGE PLUS - BASE MODULE, owner's manual ADVANTOR ADVANTAGE PLUS - BASE MODULE, online manual ADVANTOR ADVANTAGE PLUS - BASE MODULE.


Access web reviews
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.