Download user guide, user manual, owner manual and instructions guide
5 600 brands
1 870 000 user's guides
Search a brand
Advanced Search



Our partners wish to propose you the following products


Visit AMX official site

User manual AMX AXB-232++ RS-232422 INTERFACE (ENHANCED FUNCTIONALITY)

Diplodocs help download the user guide AMX AXB-232++ RS-232422 INTERFACE (ENHANCED FUNCTIONALITY).



Download the user manual AMX AXB-232++ RS-232422 INTERFACE (ENHANCED FUNCTIONALITY)  
Download the complete
user guide (307 Ko)
Need help, support, reviews, tips or troubleshooting for your AMX AXB-232++ RS-232422 INTERFACE (ENHANCED FUNCTIONALITY) products ?

This product, although classified under the brand AMX, may have been manufactured by PROCON after mergers, acquisitions, or a change in name.

Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
User guide AMX AXB-232++ RS-232422 INTERFACE (ENHANCED FUNCTIONALITY)

Detailed instructions for use are in the User's Guide.

instruction manual AXB-232++ RS-232/422/485 Interface AXlink Bus Controllers Table of Contents Table of Contents Product Information .................................................................................................1 Front Panel........................................................................................................................ 1 Rear Panel ........................................................................................................................ 1 Specifications .................................................................................................................... 2 Installation and Wiring .............................................................................................3 Setting the Internal Jumpers ............................................................................................. 3 Setting jumper JP4 to terminate RS-422 input with 100 ohms................................................. 3 Setting jumper JP5 to set the RS-422 port for RS-485 use ..................................................... 4 Setting the DIP Switches................................................................................................... 4 Setting the DEVICE DIP switch................................................................................................ 4 Setting the RS-232/422 DIP switch.......................................................................................... 5 Wiring Devices to the AXB-232++..................................................................................... 6 Preparing captive wires............................................................................................................ 6 Wiring guidelines...................................................................................................................... 6 Using AXlink............................................................................................................................. 6 Using AXlink and External Power Supply ................................................................................ 6 Using RS-232........................................................................................................................... 7 Using Hardware Handshaking ................................................................................................. 7 Using RS-422........................................................................................................................... 7 Using RS-485........................................................................................................................... 7 Rack-mounting the AXB-232++ (optional) ............................................................................... 8 Replacing the Lithium Batteries ............................................................................................... 8 Programming ............................................................................................................9 Send_Commands.............................................................................................................. 9 Axcess program characteristics ............................................................................................. 11 Send_String Escape Sequences..................................................................................... 12 AXB-232++ Program Statements.................................................................................... 13 Xmodem Timing Commands........................................................................................... 14 AXlink Master Statements ............................................................................................... 14 Reserved Channels......................................................................................................... 15 Axcess Master Mode....................................................................................................... 15 AXB-232++ RS-232/422/485 Interface i Table of Contents ii AXB-232++ RS-232/422/485 Interface Product Information Product Information The AXB-232++ RS-232/422/485 Interface is an AXlink bus controller that provides remote control for devices that require a variety of control protocols. The AXB-232++ extends RS-232, RS-422, or RS-485 control to remote sources over the 4-wire AXlink data/power bus. Onboard processing and memory allows the controller to take on complex tasks by itself, reducing the processing burden for the Axcess control system. For example, the control system can use simplified commands for generic video switcher or code control, a modular driver program in the AXB-232++ can process control for specific makes and models. Front Panel FIG. 1 displays the front panel of the AXB-232++. AXlink DEVICE ON RS-232/422 ON RX TX AXlink LED DEVICE DIP switch TX LED RX LED RS-232/422 DIP Switch FIG. 1 AXB-232++ front panel Rear Panel FIG. 2 displays the rear panel of the AXB-232++. RS232 GND RTS CTS RS422 12V RX RX RS232 GND GND RX AXlink PWR AXM AXP TX TX Hardware handshaking connections RS422 connections FIG. 2 AXB-232++ rear panel TX AXlink connector RS232 connections AXB-232++ RS-232/422/485 Interface 1 Product Information Specifications The following table lists the specifications for the AXB-232++. Specifications Power Processor 12 VDC @ 160 mA On board 32-bit processor and 384K (of non-volatile memory) run Axcess programs independent of the control system. This relieves the AXlink bus and controller for the processing time for controlling those devices. (Requires Axcess Version 3.0 or higher.) · Baud rates - 300, 600, 1200. 2400, 4800, 9600, 19200 and 38400. 56400 is supported via the BAUDMED Send Command (see the Send_Commands section on page 9 for details). 115200 is supported via the BAUDHIGH Send Command (see the Send_Commands section on page 9 for details). · Data bits - 7, 8, and 9 · Stop bits - 1 and 2 · Parity - None, Odd, Even, Mark and Space Buffers Front Panel AXlink LEDs Green AXlink status indicator: · Full-Off indicates no power is being received or the controller is not functioning properly. · One blink per second power is active and AXlink communication is functioning. · Full-On indicates power is active and AXlink data communication is not functional. RX LED (Red) TX LED (Red) DEVICE DIP Switch Blinks to indicate the AXB-232++ is receiving RS-232, RS-422, or RS-485 data. The RX LED blinks even if the data being received is incorrect. Blinks to indicate the AXB-232++ is sending RS-232, RS-422, or RS-485 data. An eight-position DIP switch used to set the device number for the AXB-232++. Refer to Setting the DEVICE DIP switch, on page 4, and Setting jumper JP5 to set the RS-422 port for RS-485 use section on page 4 for more information. An eight-position DIP switch used to set the communication parameters for the RS-232/422 device. Refer to Setting the RS-232/422 DIP switch, on page 5, for more information. · 1KB input buffer · 1KB AXlink buffer Asynchronous data standards RS232/422 DIP Switch Rear Panel Hardware handshaking connector RS422/232 connector AXlink connector Internal Jumpers Supports Dimensions (HWD) Weight Enclosure Included Accessories Optional Accessories An RTS/CTS data connector that can be wired for hardware handshaking if called for by the controlled device (4-pin male). A captive-wire connector wired for RS-422/232 data control (8-pin male). Receives power and data via the AXlink bus and AXlink system controller (4-pin male). Sets differential input termination and enables RS-485 output. XON/XOFF software and hardware handshaking 1.5" x 5.5" x 5.5" (3.81 cm x 13.97 cm x 13.97 cm) 1.1 lbs. (498.95 g) Metal with black matte finish · AXlink connector (4-pin female) · Phoenix connector (8-pin male) · CC-232 Control Cable · AC-RK Accessory Rack Kit · 12 VDC power supply, 800 mA 2 AXB-232++ RS-232/422/485 Interface Installation and Wiring Installation and Wiring The AXB-232++ can be used as an independent RS-232/422/485-controlled interface by setting the internal jumpers. Configure the communication parameters using the DIP switches on the front panel. Setting the Internal Jumpers JP4 Internal jumper JP4 Internal jumper JP5 JP5 CORP. 1998 front AXB-232++ FIG. 3 Location of internal jumpers Setting jumper JP4 to terminate RS-422 input with 100 ohms Terminating a device involves installing a 100 ohm line terminator, this is typically used to achieve better communication and signal integrity. You will want to terminate when the communication is at a high data rate or over a long distance. Termination can be harmful because it increases the current in the line, and more radiation that could interfere with signals. Jumper JP4 places 100 Ohms termination across RS422 receive data pins 5 & 6: 1. Disconnect the RS-232/422/485 connectors. 2. Unscrew the two screws on the rear panel, and remove the panel. 3. Slide the circuit board out of the enclosure. 4. Locate the JP4 jumper (FIG. 3). 5. Install the jumper in the 'ON' position (default setting = OFF). 6. Slide the circuit board back into the enclosure. 7. Replace the panel, and refasten the screws. 8. Reconnect the RS-232/422/485 connectors. AXB-232++ RS-232/422/485 Interface 3 Installation and Wiring Setting jumper JP5 to set the RS-422 port for RS-485 use 1. Disconnect the RS-232/422/485 connectors. 2. Unscrew the two screws on the rear panel, and remove the panel. 3. Slide the circuit board out of the enclosure. 4. Locate the JP5 jumper (see FIG. 3 on page 3). 5. Set jumper JP5 to the ON position (the default setting is OFF). 6. Slide the circuit board back into the enclosure. 7. Replace the panel, and refasten the screws. 8. Reconnect the RS-232/422/485 connectors. Setting the DIP Switches Use the DIPSwitch 2.0 application available for free download from AMX to quickly figure out DIP Switch settings for all types of DIP Switches. Setting the DEVICE DIP switch Set the device number on DEVICE DIP switch, located on the front of the AXB-232++. The device can be 1 of the 255 devices in an Axcess control system. The device number must match the device assignment in the Axcess program. Device numbers are assigned into the following three segments: Cards 1 through 95 Boxes 96 through 127 Panels 128 through 255 Set the device number by setting the device DIP switches. The device number is the total of all of the switches in the ON position, and take effect by cycling the power. The following table shows the switch numbers and their corresponding values. DEVICE DIP Switch Settings Position Value 1 1 2 2 3 4 4 8 5 16 6 32 7 64 8 128 4 AXB-232++ RS-232/422/485 Interface Installation and Wiring Setting the RS-232/422 DIP switch Set the stop bits, data bits, parity, and baud rate on the RS-232/422 DIP switch, located on the front panel (see FIG. 1 on page 1). The AXB-232++ supports the following asynchronous data standards: Stop bits 1 and 2 Data bits 7, 8, and 9 Parity None, Odd, Even, Mark, and Space Baud rates 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200 and 38,400. 57,600 is achieved by setting the DIP switch to 300 baud, and using the 'BAUDMED' Send_Command (see the Send_Commands section on page 9 for details). 115,200 is achieved by setting the DIP switch to 300 baud, and using the 'BAUDHIGH' Send_Command (see the Send_Commands section on page 9 for details). The table below shows the RS-232/422 DIP switch numbers, functions, and their corresponding values. RS-232/422 DIP Switch Settings Switch 1 2 3 4 Parity Off Off Unused On Off Unused Off RS232/422 On Unused On On Unused 1 2 3 4 5 6 7 8 ON Off Off Mark On Off Even Off On Odd On On None On On On Off On On On Off Off On Off Off Off On Off Off 5 6 7 Baud Rates Off 300 Off 600 On 1,200 On 2,400 Off 4,800 Off 9,600 On 19,200 On 38,400 On On On On Off Off Off Off 8 Function Stop Bits Data Bits Setting Value Off 2 bits On 1 bit Off 7 bits On 8 bits AXB-232++ RS-232/422/485 Interface 5 Installation and Wiring Wiring Devices to the AXB-232++ Preparing captive wires To connect the wiring into a captive-wire connector: 1. Strip 1/4 inch off the wire insulation for all four wires. 2. Tin 2/3 of the exposed wire. 3. Insert each wire into the appropriate captive-wire connector up to the insulation. 4. Tighten the captive screws to secure the fit in the connector. If the device is using a separate power supply, do not connect the power wiring from the AXB-232++ to that device. Wiring guidelines The interface requires a 12 VDC power to operate properly. The interface uses a PSN2.8 power supply. The Central Controller supplies power via the AXlink cable or external 12 VDC power supply. The maximum wiring distance between the Central Controller and interface is determined by power consumption, supplied voltage, and the wire gauge used for the cable. The table below lists wire sizes and maximum lengths allowable between the AXB-RS232++ and Central Controller. The maximum wiring lengths for using AXlink power are based on a minimum of 13.5 volts available at the Central Controller's power supply. Wiring Guidelines at 160 mA Wire Size Maximum Wiring Length 18 AWG 20 AWG 22 AWG 24 AWG 733.57 feet (223.59 m) 464.11 feet (141.46 m) 289.35 feet (88.19 m) 182.39 feet (55.59 m) Using AXlink Connect the AXlink wiring to the connector on the AXB-232++ as shown in FIG. 4. PWR AXP AXM GND PWR AXP AXM GND AXlink System FIG. 4 AXlink bus and +12 VDC power wiring Using AXlink and External Power Supply Connect the AXlink and power wiring to the connector on the AXB-232++ as shown in FIG. 5. PWR AXP AXM GND PWR AXP AXM GND +12 VDC GND FIG. 5 AXlink bus and +12 VDC power wiring AXlink System Power Supply 6 AXB-232++ RS-232/422/485 Interface Installation and Wiring Using RS-232 When communicating via RS-232, connect the wiring as shown in FIG. 6. GND RX TX +12V RX RX + TX TX + GND RX TX Device AXB232++ FIG. 6 RS-232 wiring Using Hardware Handshaking When the controlled device requires hardware handshaking, connect the wiring as shown in FIG. 7. 1 AXB-232++ 2 3 4 CTS RTS RTS CTS Device FIG. 7 Hardware handshaking wiring Using RS-422 When communicating via RS-422, connect the wiring as shown in FIG. 8. GND RX TX +12V AXB232++ RX RX + TX TX + GND TXTX+ RXRX+ Device FIG. 8 RS-422 wiring Using RS-485 When communicating via RS-485, connect the wiring as shown in FIG. 9. GND RX TX +12V RX RX + TX TX + AXB232++ Device FIG. 9 RS-485 wiring AXB-232++ RS-232/422/485 Interface 7 Installation and Wiring Rack-mounting the AXB-232++ (optional) To rack-mount the AXB-232++ into the optional AC-RK Accessory Rack Kit: 1. Remove any connected power, and AXlink and RS-232 connectors from the rear panel. 2. Remove the two screws on the front panel of the AXB-232++. 3. Remove the front panel and space bracket behind the panel. 4. Place the unit in the appropriate opening in the AC-RK. 5. Place the front panel of the AXB-232++ on the front of the rack, over the unit. 6. Fasten the front panel to the rack and unit with the two screws you removed. Replacing the Lithium Batteries The AXB-232++'s lithium batteries have a life of approximately 5 years to protect its memory. When DC power is on, the batteries are not used. When you install the AXB-232++, record the date the batteries should be replaced. There is a danger of explosion if you replace the batteries incorrectly. Replace batteries with the same or equivalent type recommended by the manufacturer. Dispose of the used batteries according to the manufacturer's instructions. Never recharge, disassemble, or heat batteries above 212°F (100°C). Never solder directly to the batteries or expose the contents of the batteries to water. Before removing the lithium batteries, contact your dealer and verify that they have a current copy of your program to avoid an inadvertent loss of data and prevent an unnecessary service outage. 1. Discharge the static electricity from your body. 2. Unplug the two-pin power connector and any other connectors. 3. Remove the two screws on the front panel. 4. Remove the front panel, and slide the circuit board out of the enclosure. 5. Carefully slide each battery out of its socket (FIG. 10), and insert the new battery. Battery (CR2032 type - 20mm coin cell) socket FIG. 10 Lithium battery and socket 6. Slide the circuit board back into the enclosure. 7. Replace the front panel and refasten the two screws. 8. Reconnect any connectors that you removed. 8 AXB-232++ RS-232/422/485 Interface Programming Programming Send_Commands The AXB-232++ supports the same command set as the AXC-232. The following table lists the AXB-232++ Send_Commands. AXB-232++ Send_Commands B9MOFF Sets data bit mode to normal with DIP switch settings (default). Syntax: 'B9MOFF' Example: SEND_COMMAND AXB232,'B9MOFF' Sets the data bit mode to normal. B9MON Enables a special mode to override DIP switch settings. Syntax: 'B9MON' The mode, nine data bits with one stop bit, overrides the data, stop, and parity settings. When the AXB-232++ issues this command, it locks in the baud rate determined by the current DIP switch setting. Example: SEND_COMMAND AXB232,'B9MON' Overrides the DIP switch settings. BAUDHIGH Enables 115,200 baud rate when the DIP switch is set to 300 baud. Syntax: 'BAUDHIGH' Example: SEND_COMMAND AXB232,'BAUDHIGH' Enables 115,200 baud rate. BAUDLOW Enables 300 baud rate when the DIP switch is set to 300 baud setting (default). Syntax: 'BAUDLOW' Example: SEND_COMMAND AXB232,'BAUDLOW' Enables 300 baud rate. BAUDMED Enables 57,600 baud rate when the DIP switch is set to 300 baud. Syntax: 'BAUDMED' Example: SEND_COMMAND AXB232,'BAUDMED' Enables 57,600 baud rate. CB1ON Syntax: Enables placement of charac- 'CB1ON' ters in the buffer specified by Example: CREATE_BUFFER 1 SEND_COMMAND AXB232,'CB1ON' (default). Enables placement of characters in the buffer. CB1OFF Disables placement of characters in the buffer specified by CREATE_BUFFER 1. Syntax: 'CB1OFF' Example: SEND_COMMAND AXB232,'CB1OFF' Disables placement of characters in the buffer. AXB-232++ RS-232/422/485 Interface 9 Programming AXB-232++ Send_Commands (Cont.) CHARD Sets delay between all transmitted characters to the increment specified. Syntax: 'CHARD-

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AMX AXB-232++ RS-232422 INTERFACE (ENHANCED FUNCTIONALITY).

AMX offer a product for which we do not have the user manual? Let us know what you are looking for: site Internet, histoire, actualité, filiales, site Internet, mode d'emploi, driver, avis des utilisateurs, meilleur prix des produits, forum d'assistance aux problèmes, annuaire des marques, annuaire des constructeurs, répertoire des marques, répertoire des constructeurs, site Internet de la marque, site Internet du constructeur

Diplodocs allows you to download user manual AMX AXB-232++ RS-232422 INTERFACE (ENHANCED FUNCTIONALITY), user guide AMX AXB-232++ RS-232422 INTERFACE (ENHANCED FUNCTIONALITY), instructions AMX AXB-232++ RS-232422 INTERFACE (ENHANCED FUNCTIONALITY), owner's manual AMX AXB-232++ RS-232422 INTERFACE (ENHANCED FUNCTIONALITY), online manual AMX AXB-232++ RS-232422 INTERFACE (ENHANCED FUNCTIONALITY).


Access web reviews AMX AXB-232++ RS-232422 INTERFACE (ENHANCED FUNCTIONALITY), AMX CORPORATION, Router, Switch, Firewall & Other network security hardware.
Include the add-on to download manuals from your site, forum or blog Frequently Asked Questions Contact Diplodocs team Last searches
Last additions
Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.