Detailed instructions for use are in the User's Guide.
instruction manual
AXB-MPE+
Master Port Expander
AXB-SPE
Slave Port Expander
A x c e s s C e n t ra l C o n t r o l l e r s a n d C a r d s
AMX Limited Warranty and Disclaimer
AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX Corporation, with the following exceptions: · · · · · Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year. Disk drive mechanisms, pan/tilt heads, power supplies, MX Series products, and KC Series products are warranted for a period of one (1) year. Unless otherwise specified, OEM and custom products are warranted for a period of one (1) year. Software is warranted for a period of ninety (90) days. Batteries and incandescent lamps are not covered under the warranty.
This warranty extends only to products purchased directly from AMX Corporation or an Authorized AMX Dealer. AMX Corporation is not liable for any damages caused by its products or for the failure of its products to perform. This includes any lost profits, lost savings, incidental damages, or consequential damages. AMX Corporation is not liable for any claim made by a third party or by an AMX Dealer for a third party. This limitation of liability applies whether damages are sought, or a claim is made, under this warranty or as a tort claim (including negligence and strict product liability), a contract claim, or any other claim. This limitation of liability cannot be waived or amended by any person. This limitation of liability will be effective even if AMX Corporation or an authorized representative of AMX Corporation has been advised of the possibility of any such damages. This limitation of liability, however, will not apply to claims for personal injury. Some states do not allow a limitation of how long an implied warranty last. Some states do not allow the limitation or exclusion of incidental or consequential damages for consumer products. In such states, the limitation or exclusion of the Limited Warranty may not apply. This Limited Warranty gives the owner specific legal rights. The owner may also have other rights that vary from state to state. The owner is advised to consult applicable state laws for full determination of rights. EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY, AMX CORPORATION MAKES NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. AMX CORPORATION EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY. ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF THIS LIMITED WARRANTY.
Table of Contents
Table of Contents
Product Information .................................................................................................1
AXB-MPE+ Dual and Single Master Port Expanders ........................................................ 1 AXB-SPE Slave Port Expander......................................................................................... 3
Installation and Configuration .................................................................................5
AXC-EM Master Card DIP Switch Settings ....................................................................... 5 PROGRAM RS-232 DIP Switch Settings .......................................................................... 6 Configuring the MPE+ to use One or Two AXC-EM Cards ............................................... 7 Wiring the AXB-MPE+ and AXB-SPE ............................................................................... 8
Guidelines ................................................................................................................................ 8 Preparing captive wires............................................................................................................ 8 Using AXlink for data and a 12 VDC power supply.................................................................. 8 Connecting an AXB-MPE+ to the AXB-SPE ............................................................................ 9 Replacing the Lithium Batteries ............................................................................................... 9
256 KB Firmware Upgrade.............................................................................................. 10 256 KB Memory Upgrade................................................................................................ 11 Installing the AXB-MPE+, AXB-SPE, and External Equipment ....................................... 11 AXCESS Programming ................................................................................................... 11
Programming the AXB-MPE+ (One AXC-EM Card) .............................................................. 11 Programming the AXB-MPE+ Dual Master Port Expander (Two AXC-EM Cards) ................ 12
AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander
i
Table of Contents
ii
AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander
Product Information
Product Information
AXB-MPE+ Dual and Single Master Port Expanders
The AXB-MPE+ Dual and Single Master Port Expanders (FIG. 1) are AXCESS Control Systems that are equipped with 12 AXlink ports that can control multiple audiovisual and lighting device up to 3,000 feet from the control system. With the AXCESS programming software, you program the AXC-EM cards, housed in the AXB-MPE+, to control the devices. The AXB-MPE+ Dual Master Port Expander comes with two AXC-EM cards: the first card is the main processor and the second is the stand-by processor. If a problem occurs with the first card, the AXB-MPE+ automatically switches to the second card without disrupting service.
AXlink status LED PROGRAM port PROGRAM RS-232 DIP switch
AXLINK PROGRAM RS-232
ON
(front)
AXLINK PORT STATUS LEDs
11 12
AXLINK PORT STATUS 1 2 3 4 5 6 7 8 9 10
(front)
PROGRAM MC1 MC1 PROGRAM RS-232
ON
PROGRAM MC1 port PROGRAM RS-232 DIP switch
AXLINK PORT STATUS MC2 1 2 3 4 5 6 7 8 9 10 11 12
AXLINK PORT STATUS LEDs
MC2 status LED MC1 status LED (rear)
PWR PWR PWR PWR PWR PWR PWR PWR PWR AXM AXM AXM AXM AXM AXM AXM AXM AXM GND GND GND GND GND GND GND GND GND GND AXP AXP AXP AXP AXP AXP AXP AXP AXP IN OUT
PWR connector
PWR PWR PWR AXM AXM GND GND AXM AXP AXP AXP 12VDC PROGRAM MC1 / MC2
EXPANSION
AXlink 12
AXlink 11
AXlink 10
AXlink 9
AXlink 8
AXlink 7
AXlink 6
AXlink 5
AXlink 4
AXlink 3
AXlink 2
AXlink 1
PWR
AXlink connectors (1-12) EXPANSION IN/OUT ports FIG. 1 AXB-MPE+ Master Port Expander and Dual Master Port Expander PROGRAM MC1 / MC2 port
The following table lists specifications for the AXB-MPE+: AXB-MPE+ Specifications
Product Type Program Control AXlink bus expansion accessory · AXC-EM Enhanced System Master Card built-in · Two DB-9 RS-232 program ports · DIP switch to set communication parameters Device Connectors Expansion Connectors Power 12 four-terminal connectors for captive wire compression Two 4-pin modular telco connectors · 11.8 to 16V DC, 250mA (using 2 AXC-EM cards) (150 mA max draw per AXC-EM card) · 2-pin captive-wire connector Note: Power rating does not include externally connected AXlink devices. Dimensions (HWD) Weight Rack 1.72" x 19.00"(with rack ears) x 12.09" (4.37 cm x 48.26 cm x 30.71 cm) 6 lbs. (2.72 kg) One standard rack unit high. Rack mounts included.
AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander
1
Product Information
AXB-MPE+ Specifications (Cont.)
Front Panel Components: AXlink status LED: Green LED that blinks to indicate power and AXlink communication activity. Blink status for the AXlink LED includes: · Off: no power or the AXC-EM Master Card is not functioning properly. · One blink: normal operation. Device numbers match the programmed device numbers in the AXCESS program. · Two blinks: device numbers do not match the AXCESS program, a device is not present, or a device is not to the right number. · Three blinks: AXlink bus error. You should check AXlink wiring. · Full on: AXCESS program is not present in the AXC-EM card, and there is no AXlink activity. MC1 and MC2 LEDs: Green LED that blinks to indicate power and AXlink communication activity on the AXC-EM Master Cards 1 and 2. The blink patterns are identical to those described above for the AXlink LED. DB-9 male connector that connects to a PC or other RS-232 device. Use the PROGRAM port to download the AXCESS programs to the AXC-EM card. On the Dual Master Port Expander Plus, this port is designated as PROGRAM MC1 (Master Card #1). PROGRAM RS-232 DIP Switch 8-position communication DIP switch that sets the baud rate, data bits, parity, and stop bits. The default settings are 1 stop bit, 8 data bits, no parity, and 38.4K baud. AXLINK PORT STATUS LEDs Rear Panel Components: Expansion Ports (IN/OUT) AXlink Ports (1-12) Two RJ-11 4-pin modular connectors that interconnect the AXB-MPE+ and AXB-SPE. 12 four-pin (male) AXlink connectors. The distance between external devices and the AXB-MPE+ is 3,000 feet (914.4 meters) for AXlink data communication. If the external equipment requires supplemental power, refer to the manufacturer's literature to determine what type of power supply is required. DB-9 connector (male) that connects to a PC to program the AXC-EM Master Cards. · For single AXC-EM Master Card configurations, you use the PROGRAM connector to program the Master Card. · For dual AXC-EM Master Card configurations, you use the PROGRAM connector to program the Master Card installed in the Master #2 card slot (MC2). PWR connector Two-pin (male) connector that supplies 12VDC to the AXB-MPE+. The power is distributed in parallel to each AXlink connector. The total load for all AXlink connectors must not exceed 4 amps. 12 red LEDs that show AXlink port activity. The LEDs light when a device connected to the port transmits data.
PROGRAM (MC1) port
PROGRAM port
2
AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander
Product Information
AXB-SPE Slave Port Expander
The AXB-SPE Slave Port Expander (FIG. 2) contains 12 AXlink ports that you can control with the AXB-MPE+. You can connect the AXB-SPE to the AXB-MPE+, and then control 12 additional AXlink bus lines. The AXB-SPE is an add-on device that connects to the AXB-MPE+ via RJ-11 modular connectors. The AXB-SPE ports are controlled by the online AXC-EM Master Card in the AXB-MPE+.
AXLINK PORT STATUS LEDs
AXLINK PORT STATUS 1 2 3 4 5 6 7 8 9 10 11 12
(rear)
PWR PWR PWR PWR PWR PWR PWR PWR PWR AXM AXM AXM AXM AXM AXM AXM AXM AXM GND GND GND GND GND GND GND GND GND GND AXP AXP AXP AXP AXP AXP AXP AXP AXP IN OUT
PWR connector
PWR PWR PWR AXM AXM GND GND AXM AXP AXP AXP 12VDC PROGRAM MC1 / MC2
EXPANSION
AXlink 12
AXlink 11
AXlink 10
AXlink 9
AXlink 8
AXlink 7
AXlink 6
AXlink 5
AXlink 4
AXlink 3
AXlink 2
AXlink 1
PWR
AXlink connectors (1-12) EXPANSION IN/OUT ports FIG. 2 AXB-SPE Slave Port Expander PROGRAM MC1 / MC2 port
The following table lists specifications for the AXB-SPE: AXB-SPE Specifications
Product Type Program Control Device Connectors Expansion Connectors Power Dimensions (HWD) Weight Front Panel Components: AXLINK PORT STATUS LEDs 12 red LEDs that show AXlink port activity. The LEDs light when a device connected to the port transmits data. Rear Panel Components: Expansion Ports (IN/OUT) AXlink Ports (1-12) Two RJ-11 4-pin connectors that interconnect the AXB-SPE and AXB-MPE+. 12 four-pin (male) AXlink connectors. The distance between the external AMX equipment and the AXB-MPE+ is 3,000 feet (914 meters) for AXlink data communication. If the AMX equipment requires supplemental power, refer to the associated product manual's to determine if supplement power is required. Not used. Two-pin (male) connector that supplies 12VDC to the AXB-SPE. The power is distributed in parallel to each AXlink connector. The total load for all AXlink connectors must not exceed 4 amps. 12 four-terminal connectors for captive wire compression Two 4-pin modular telco connectors · 11.8 to 16V DC, 150mA (maximum draw) · 2-pin connector for captive wire compression · 1.72" x 19.00"(with rack ears) x 12.09" (4.37 cm x 48.26 cm x 30.71 cm) · One standard rack unit high. Rack mounts included. 6 lbs. (2.72 kg) AXlink bus expansion accessory
PROGRAM MC1 / MC2 port PWR connector
AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander
3
Product Information
4
AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander
Installation and Configuration
Installation and Configuration
Before you install the AXB-MPE+, you should check the AXC-EM Master Card DIP switch for correct settings, and also set the PROGRAM RS-232 DIP switch on the front panel of the AXBMPE+. FIG. 1 shows the orientation of the AXC-EM components discussed in this section.