AXB-MPE+
Master Port Expander
AXB-SPE
Slave Port Expander
A x c e s s C e n t ra l C o n t r o l l e r s a n d C a r d s
AMX Limited Warranty and Disclaimer
AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX Corporation, with the following exceptions: · · · · · Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year. Disk drive mechanisms, pan/tilt heads, power supplies, MX Series products, and KC Series products are warranted for a period of one (1) year. Unless otherwise specified, OEM and custom products are warranted for a period of one (1) year. Software is warranted for a period of ninety (90) days. Batteries and incandescent lamps are not covered under the warranty.
This warranty extends only to products purchased directly from AMX Corporation or an Authorized AMX Dealer. AMX Corporation is not liable for any damages caused by its products or for the failure of its products to perform. This includes any lost profits, lost savings, incidental damages, or consequential damages. AMX Corporation is not liable for any claim made by a third party or by an AMX Dealer for a third party. This limitation of liability applies whether damages are sought, or a claim is made, under this warranty or as a tort claim (including negligence and strict product liability), a contract claim, or any other claim. This limitation of liability cannot be waived or amended by any person. This limitation of liability will be effective even if AMX Corporation or an authorized representative of AMX Corporation has been advised of the possibility of any such damages. This limitation of liability, however, will not apply to claims for personal injury. Some states do not allow a limitation of how long an implied warranty last. Some states do not allow the limitation or exclusion of incidental or consequential damages for consumer products. In such states, the limitation or exclusion of the Limited Warranty may not apply. This Limited Warranty gives the owner specific legal rights. The owner may also have other rights that vary from state to state. The owner is advised to consult applicable state laws for full determination of rights. EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY, AMX CORPORATION MAKES NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. AMX CORPORATION EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY. ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF THIS LIMITED WARRANTY.
Table of Contents
Table of Contents
Product Information .................................................................................................1
AXB-MPE+ Dual and Single Master Port Expanders ........................................................ 1 AXB-SPE Slave Port Expander......................................................................................... 3
Installation and Configuration .................................................................................5
AXC-EM Master Card DIP Switch Settings ....................................................................... 5 PROGRAM RS-232 DIP Switch Settings .......................................................................... 6 Configuring the MPE+ to use One or Two AXC-EM Cards ............................................... 7 Wiring the AXB-MPE+ and AXB-SPE ............................................................................... 8
Guidelines ................................................................................................................................ 8 Preparing captive wires............................................................................................................ 8 Using AXlink for data and a 12 VDC power supply.................................................................. 8 Connecting an AXB-MPE+ to the AXB-SPE ............................................................................ 9 Replacing the Lithium Batteries ............................................................................................... 9
256 KB Firmware Upgrade.............................................................................................. 10 256 KB Memory Upgrade................................................................................................ 11 Installing the AXB-MPE+, AXB-SPE, and External Equipment ....................................... 11 AXCESS Programming ................................................................................................... 11
Programming the AXB-MPE+ (One AXC-EM Card) .............................................................. 11 Programming the AXB-MPE+ Dual Master Port Expander (Two AXC-EM Cards) ................ 12
AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander
i
Table of Contents
ii
AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander
Product Information
Product Information
AXB-MPE+ Dual and Single Master Port Expanders
The AXB-MPE+ Dual and Single Master Port Expanders (FIG. 1) are AXCESS Control Systems that are equipped with 12 AXlink ports that can control multiple audiovisual and lighting device up to 3,000 feet from the control system. With the AXCESS programming software, you program the AXC-EM cards, housed in the AXB-MPE+, to control the devices. The AXB-MPE+ Dual Master Port Expander comes with two AXC-EM cards: the first card is the main processor and the second is the stand-by processor. If a problem occurs with the first card, the AXB-MPE+ automatically switches to the second card without disrupting service.
AXlink status LED PROGRAM port PROGRAM RS-232 DIP switch
AXLINK PROGRAM RS-232
ON
(front)
AXLINK PORT STATUS LEDs
11 12
AXLINK PORT STATUS 1 2 3 4 5 6 7 8 9 10
(front)
PROGRAM MC1 MC1 PROGRAM RS-232
ON
PROGRAM MC1 port PROGRAM RS-232 DIP switch
AXLINK PORT STATUS MC2 1 2 3 4 5 6 7 8 9 10 11 12
AXLINK PORT STATUS LEDs
MC2 status LED MC1 status LED (rear)
PWR PWR PWR PWR PWR PWR PWR PWR PWR AXM AXM AXM AXM AXM AXM AXM AXM AXM GND GND GND GND GND GND GND GND GND GND AXP AXP AXP AXP AXP AXP AXP AXP AXP IN OUT
PWR connector
PWR PWR PWR AXM AXM GND GND AXM AXP AXP AXP 12VDC PROGRAM MC1 / MC2
EXPANSION
AXlink 12
AXlink 11
AXlink 10
AXlink 9
AXlink 8
AXlink 7
AXlink 6
AXlink 5
AXlink 4
AXlink 3
AXlink 2
AXlink 1
PWR
AXlink connectors (1-12) EXPANSION IN/OUT ports FIG. 1 AXB-MPE+ Master Port Expander and Dual Master Port Expander PROGRAM MC1 / MC2 port
The following table lists specifications for the AXB-MPE+: AXB-MPE+ Specifications
Product Type Program Control AXlink bus expansion accessory · AXC-EM Enhanced System Master Card built-in · Two DB-9 RS-232 program ports · DIP switch to set communication parameters Device Connectors Expansion Connectors Power 12 four-terminal connectors for captive wire compression Two 4-pin modular telco connectors · 11.8 to 16V DC, 250mA (using 2 AXC-EM cards) (150 mA max draw per AXC-EM card) · 2-pin captive-wire connector Note: Power rating does not include externally connected AXlink devices. Dimensions (HWD) Weight Rack 1.72" x 19.00"(with rack ears) x 12.09" (4.37 cm x 48.26 cm x 30.71 cm) 6 lbs. (2.72 kg) One standard rack unit high. Rack mounts included.
AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander
1
Product Information
AXB-MPE+ Specifications (Cont.)
Front Panel Components: AXlink status LED: Green LED that blinks to indicate power and AXlink communication activity. Blink status for the AXlink LED includes: · Off: no power or the AXC-EM Master Card is not functioning properly. · One blink: normal operation. Device numbers match the programmed device numbers in the AXCESS program. · Two blinks: device numbers do not match the AXCESS program, a device is not present, or a device is not to the right number. · Three blinks: AXlink bus error. You should check AXlink wiring. · Full on: AXCESS program is not present in the AXC-EM card, and there is no AXlink activity. MC1 and MC2 LEDs: Green LED that blinks to indicate power and AXlink communication activity on the AXC-EM Master Cards 1 and 2. The blink patterns are identical to those described above for the AXlink LED. DB-9 male connector that connects to a PC or other RS-232 device. Use the PROGRAM port to download the AXCESS programs to the AXC-EM card. On the Dual Master Port Expander Plus, this port is designated as PROGRAM MC1 (Master Card #1). PROGRAM RS-232 DIP Switch 8-position communication DIP switch that sets the baud rate, data bits, parity, and stop bits. The default settings are 1 stop bit, 8 data bits, no parity, and 38.4K baud. AXLINK PORT STATUS LEDs Rear Panel Components: Expansion Ports (IN/OUT) AXlink Ports (1-12) Two RJ-11 4-pin modular connectors that interconnect the AXB-MPE+ and AXB-SPE. 12 four-pin (male) AXlink connectors. The distance between external devices and the AXB-MPE+ is 3,000 feet (914.4 meters) for AXlink data communication. If the external equipment requires supplemental power, refer to the manufacturer's literature to determine what type of power supply is required. DB-9 connector (male) that connects to a PC to program the AXC-EM Master Cards. · For single AXC-EM Master Card configurations, you use the PROGRAM connector to program the Master Card. · For dual AXC-EM Master Card configurations, you use the PROGRAM connector to program the Master Card installed in the Master #2 card slot (MC2). PWR connector Two-pin (male) connector that supplies 12VDC to the AXB-MPE+. The power is distributed in parallel to each AXlink connector. The total load for all AXlink connectors must not exceed 4 amps. 12 red LEDs that show AXlink port activity. The LEDs light when a device connected to the port transmits data.
PROGRAM (MC1) port
PROGRAM port
2
AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander
Product Information
AXB-SPE Slave Port Expander
The AXB-SPE Slave Port Expander (FIG. 2) contains 12 AXlink ports that you can control with the AXB-MPE+. You can connect the AXB-SPE to the AXB-MPE+, and then control 12 additional AXlink bus lines. The AXB-SPE is an add-on device that connects to the AXB-MPE+ via RJ-11 modular connectors. The AXB-SPE ports are controlled by the online AXC-EM Master Card in the AXB-MPE+.
AXLINK PORT STATUS LEDs
AXLINK PORT STATUS 1 2 3 4 5 6 7 8 9 10 11 12
(rear)
PWR PWR PWR PWR PWR PWR PWR PWR PWR AXM AXM AXM AXM AXM AXM AXM AXM AXM GND GND GND GND GND GND GND GND GND GND AXP AXP AXP AXP AXP AXP AXP AXP AXP IN OUT
PWR connector
PWR PWR PWR AXM AXM GND GND AXM AXP AXP AXP 12VDC PROGRAM MC1 / MC2
EXPANSION
AXlink 12
AXlink 11
AXlink 10
AXlink 9
AXlink 8
AXlink 7
AXlink 6
AXlink 5
AXlink 4
AXlink 3
AXlink 2
AXlink 1
PWR
AXlink connectors (1-12) EXPANSION IN/OUT ports FIG. 2 AXB-SPE Slave Port Expander PROGRAM MC1 / MC2 port
The following table lists specifications for the AXB-SPE: AXB-SPE Specifications
Product Type Program Control Device Connectors Expansion Connectors Power Dimensions (HWD) Weight Front Panel Components: AXLINK PORT STATUS LEDs 12 red LEDs that show AXlink port activity. The LEDs light when a device connected to the port transmits data. Rear Panel Components: Expansion Ports (IN/OUT) AXlink Ports (1-12) Two RJ-11 4-pin connectors that interconnect the AXB-SPE and AXB-MPE+. 12 four-pin (male) AXlink connectors. The distance between the external AMX equipment and the AXB-MPE+ is 3,000 feet (914 meters) for AXlink data communication. If the AMX equipment requires supplemental power, refer to the associated product manual's to determine if supplement power is required. Not used. Two-pin (male) connector that supplies 12VDC to the AXB-SPE. The power is distributed in parallel to each AXlink connector. The total load for all AXlink connectors must not exceed 4 amps. 12 four-terminal connectors for captive wire compression Two 4-pin modular telco connectors · 11.8 to 16V DC, 150mA (maximum draw) · 2-pin connector for captive wire compression · 1.72" x 19.00"(with rack ears) x 12.09" (4.37 cm x 48.26 cm x 30.71 cm) · One standard rack unit high. Rack mounts included. 6 lbs. (2.72 kg) AXlink bus expansion accessory
PROGRAM MC1 / MC2 port PWR connector
AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander
3
Product Information
4
AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander
Installation and Configuration
Installation and Configuration
Before you install the AXB-MPE+, you should check the AXC-EM Master Card DIP switch for correct settings, and also set the PROGRAM RS-232 DIP switch on the front panel of the AXBMPE+. FIG. 1 shows the orientation of the AXC-EM components discussed in this section.
Lithium batteries and sockets
Firmware EPROMs
DIP switch
Memory ICs
AXC-EM
FIG. 1 AXC-EM Master Card component orientation (batteries, EPROMS, ICs and DIP switch).
AXC-EM Master Card DIP Switch Settings
All the AXC-EM Master Card DIP switch positions must be set OFF to communicate with the AXB-MPE+. To verify the AXC-EM Master Card DIP switch is set correctly: 1. Discharge the static electricity from your body by touching a grounded object. 2. Remove the two Phillips-head screws from the top panel on the AXB-MPE+, and slide the panel backward to access the AXC-EM Master Cards. FIG. 1 shows the DIP switch location on the AXC-EM card. 3. Set all the DIP switch positions OFF (down), as shown in FIG. 2. If the AXB-MPE+ is equipped with two AXC-EM Master Cards, repeat this step on the second card.
ON 1 2 3 4 5 6 7 8
FIG. 2 AXC-EM DIP switch settings
4. Close the top panel, insert the Phillips-head screws, and tighten.
AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander
5
Installation and Configuration
PROGRAM RS-232 DIP Switch Settings
The PROGRAM RS-232 DIP switch, on the front panel of the AXB-MPE+, sets the baud rate, data bits, stop bits, and parity communication settings. The following table lists the DIP switch communication settings and shows a sample DIP switch setting of 1 stop bits, 8 data bits, no parity, and 9,600 baud: PROGRAM RS-232 DIP Switch Settings
Switch 1 2 3 4 Parity Off Off Unused On Off Unused Off On Unused On 1 2 3 4 5 6 7 8 On Unused ON Off Off Mark On Off Even Off On Odd On On None On On On Off On On On Off Off On Off Off Off On Off Off 5 6 7 Baud Rates Off 300 Off 600 On 1,200 On 2,400 Off 4,800 Off 9,600 On 19,200 On 38,400 On On On On Off Off Off Off 8 Function Stop Bits Data Bits Setting Value Off 2 bits On 1 bit Off 7 bits On 8 bits
The default values are:
! ! ! !
1 stop bit 8 data bits No parity 38.4K baud
To reset the DIP switch to its default settings, place all switches in the ON position.
6
AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander
Installation and Configuration
Configuring the MPE+ to use One or Two AXC-EM Cards
The AXB-MPE+ Master Port Expander uses one AXC-EM master card. The AXB-MPE+ Dual Master Port Expander uses two AXC-EM master cards. Both come factory set to either a single or dual expander. If you are using an AXC-MPE+ Master Port Expander and want to upgrade the unit to use two AXC-EMs: 1. Discharge the static electricity from your body by touching a grounded object. 2. Remove the two Phillips-head screws from the top panel on the AXB-MPE+, and slide the panel backward to access the AXC-EM Master Cards (FIG. 3). 3. Locate the Jumper location (JP1A and JP1B) between the AXC-EM internal connection ports.
AXC-EM Card #2 AXC-EM Card #1
Dual/Single Master Expander jumpers (JP1A and JP1B)
JP1B jumper
JP1A jumper
FIG. 3 MPE+ internal locations for AXC-EM cards and respective jumpers
4. To set the Port Expander to use one master, place the jumper from JP1A on pins 1 and 2 (SINGLE) and verify that the jumper from JP1B is also on pins 1 and 2. This setting allows the user to program the single AXC-EM card using either the front or rear Program ports. Refer to the Programming the AXB-MPE+ (One AXC-EM Card) section on page 11 for more information. 5. To set the Port Expander to use two master, place the jumper from JP1A on pins 2 and 3 (DUAL) and verify that the jumper from JP1B is also on pins 2 and 3. Refer to the Programming the AXB-MPE+ Dual Master Port Expander (Two AXC-EM Cards) section on page 12 for more information. This setting allows the user to ONLY program:
! !
AXC-EM Card #1 (see FIG. 3) using the front Program port on the MPE+ and AXC-EM Card #2 (see FIG. 3) using the rear Program port on the MPE+.
AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander
7
Installation and Configuration
Wiring the AXB-MPE+ and AXB-SPE
You must connect a 12 VDC power supply to the AXB-MPE+ and AXB-SPE to control external equipment. If you connect external AMX equipment, refer to the associated AMX manuals for wiring and power supply information. This section describes how to wire a control system. Guidelines The AXB-MPE+ and AXB-SPE requires 12 VDC power to operate properly. The maximum wiring distance between the control equipment and external equipment is determined by power consumption, supplied voltage, and the wire gauge used for the cable. The maximum wiring lengths for using AXlink power are based on a minimum of 13.5 volts available at the AXB-MPE+'s and AXB-SPE's power supply. Preparing captive wires You will need a wire stripper, soldering iron, and flat-head screwdriver to prepare and connect the captive wires. 1. Strip 0.25 inch of wire insulation off all wires and apply a light coat of solder to the ends using a soldering iron. 2. Insert each wire into the appropriate opening on the connector according to the wiring diagrams and connector types described in this section. 3. Turn the flat-head screws clockwise to secure the wire in the connector.
Do not over-torque the screw. Doing so can bend the seating pin and damage the connector.
Using AXlink for data and a 12 VDC power supply Connect the AXB-MPE+ and AXB-SPE AXlink connector to the AXlink connector on the external equipment, and the 12 VDC power supply as shown in FIG. 4.
PWR connector on AXB-MPE+ or AXB-SPE PWR+ GNDPWR+ AXP/TX AXM/RX GNDAXlink connector on AXB-MPE+ or AXB-SPE Local 12 VDC power supply
PWR+ AXP AXM GND-
External equipment
FIG. 4 AXlink and optional power supply wiring diagram
8
AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander
Installation and Configuration
Connecting an AXB-MPE+ to the AXB-SPE FIG. 5 shows how to connect the expansion cables between the AXB-MPE+ and AXB-SPE. AMX supplies the RJ-11 module cable with the AXB-SPE.
EXPANSION
AXBSPE
AXLINK 12 AXLINK 1
12VDC + PWR 12VDC + AXLINK 1 PWR
IN
OUT
EXPANSION
AXBSPE
AXLINK 12
IN OUT
EXPANSION
AXBMPE+
AXLINK 12 AXLINK 1
PROGRAM
12VDC + PWR
IN
OUT
FIG. 5 AXB-MPE+ and AXB-SPE expansion wiring diagram
Replacing the Lithium Batteries There are two lithium batteries (see FIG. 1 on page 5), with a life of approximately 5 years, on the AXC-EM Master Card that protects stored commands if there is a power loss. The batteries are not used when DC power is supplied to the cards via the AXB-MPE+. You should write down the replacement date on a sticker or label by adding 5 years to the date of installation, and then attach it to the back of the AXB-MPE+
Static electricity can damage electronic circuitry. Before removing the lithium batteries from the card, discharge any accumulated static electricity from your body and screw-driver by touching a grounded metal object.
Before you replace the lithium batteries, verify that your AMX dealer has a current copy of control commands stored in your AXB-MPE+. This will avoid any inadvertent loss of data or a service outage. You will need a flat-blade tool (non-conducting) that can be slipped under the lithium batteries to pry them up and out of the sockets:
There is a danger of explosion if you replace the battery incorrectly. Replace the battery with the same or equivalent type recommended by the manufacturer. Dispose of used battery according to the manufacturer's instructions. Never recharge, disassemble, or heat the battery above 212 °F (100 °C). Never solder directly to the battery or expose the contents of the battery to water.
1. Discharge the static electricity from your body by touching a grounded object. 2. Disconnect all the connectors from the back panel on the AXB-MPE+. Then, remove it from the equipment rack (if applicable), and lay it down on a non-conductive surface. 3. Remove the two Phillips-head screws from the top panel on the AXB-MPE+, and slide the panel backward to access the lithium batteries on the AXC-EM Master Cards. 4. Carefully pry one battery out of its socket and insert the new battery. 5. Plug the power supply back into the AXB-MPE+ for approximately 1 minute. Then, disconnect the power supply again. 6. Carefully slide the other battery out of its socket, and insert the new battery.
AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander
9
Installation and Configuration
7. Close the top panel, insert the Phillips-head screws, and tighten. 8. Return the AXB-MPE+ to the equipment rack and reconnect all the connectors removed in step 2.
256 KB Firmware Upgrade
Firmware upgrades allow you to maintain the latest available operating system for your AXBMPE+. This section describes how to remove and replace the firmware EPROMs on the AXC-EM Master Cards in the AXB-MPE+. You will need a Phillips screwdriver and a non-conducting flatblade tool to slip under the firmware ICs to lift them out of their sockets. FIG. 1 on page 5 shows where the firmware EPROMs are located on the AXC-EM cards. 1. Discharge the static electricity from your body by touching a grounded object. 2. Disconnect all the connectors from the back panel on the AXB-MPE+. Then, remove it from the equipment rack (if applicable), and lay it down on a non-conductive surface. 3. Remove the two Phillips-head screws from the top panel on the AXB-MPE+, and slide the panel backward to access the AXC-EM Master Cards. 4. Carefully pry the firmware EPROMs out of their sockets labeled U3 and U4 on card 1 and card 2 (if applicable) with a non-conducting flat-blade tool, and install the new firmware EPROMs as shown in FIG. 6.
Pin 1
Pin socket 3
FIG. 6 EPROM and IC removal and replacement
5. Close the top panel, insert the Phillips-head screws, and tighten. 6. Return the AXB-EM+ to the equipment rack and reconnect all the connectors removed in step 2.
10
AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander
Installation and Configuration
256 KB Memory Upgrade
You can replace the 64 KB integrated circuits (IC) on the AXC-EM Master Cards with the optional 256 KB upgrade ICs to increase storage capacity and processor speed. You will need a Phillips screwdriver and non-conducting flat-blade tool to slip under the 64 KB ICs and pry them out of their sockets. FIG. 1 on page 5 shows where the memory ICs are located on the AXC-EM cards. 1. Discharge the static electricity from your body by touching a grounded object. 2. Disconnect all the connectors from the back panel on the AXB-MPE+. Then, remove it from the equipment rack (if applicable), and lay it down on a non-conductive surface. 3. Remove the two Phillips-head screws from the top panel on the AXB-MPE+, and slide the panel backward to access the AXC-EM Master Cards. 4. Carefully pry the memory ICs out of their sockets labeled U1 and U2 on card 1 and card 2 (if applicable) with a non-conducting flat-blade tool, and install the new memory ICs as shown in FIG. 6. 5. Close the top panel, insert the Phillips-head screws, and tighten. 6. Return the AXB-EM+ to the equipment rack and reconnect all the connectors removed in step 2.
Installing the AXB-MPE+, AXB-SPE, and External Equipment
Install the AXB-MPE+ into a standard 19-inch rack using the supplied rack kit: 1. Mount the AXB-MPE+ and AXB-SPE in the equipment rack. Connect the power supply. 2. Mount the external AMX equipment where it will be used.
AXCESS Programming
You can program the AXC-EM Master Cards in the AXB-MPE+ with an AXCESS software program to control a wide variety of audiovisual, lighting, and audio equipment. This section describes how to program the AXB-MPE+ equipped with one or two AXC-EM Master Cards, and also the wiring diagram for the DB-9 PROGRAM connector. Refer to the AXCESS Programming Language instruction manual for more detailed information. Programming the AXB-MPE+ (One AXC-EM Card) To program the AXC-EM Master Card in the AXB-MPE+ Master Port Expander: 1. Discharge the static electricity from your body by touching a grounded object. 2. Connect your PC to the DB-9 connector on the front or back of the AXB-MPE+. FIG. 1 on page 5 shows where the PROGRAM DIP switch is located on the front and back panel of the AXB-MPE+. The following table shows a DB-9 wiring diagram and pinouts.
AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander
11
Installation and Configuration
Program Connector and Pinouts
Pin Pin 1 2 3 4 Pin 9 5 7 Signal RXD TXD +12 VDC GND +12 VDC
3. Launch the AXCESS software program, select the appropriate AXCESS software program, and download it into the AXB-MPE+. Refer to the AXCESS Programming Language instruction manual for detailed programming and downloading information. Programming the AXB-MPE+ Dual Master Port Expander (Two AXC-EM Cards) To program both AXC-EM Master Cards in the AXB-MPE+ Dual Master Port Expander: 1. Discharge the static electricity from your body by touching a grounded object. 2. Connect your PC to the DB-9 connector on the front of the AXB-MPE+ to program the AXCEM Master Card 1 (MC1). FIG. 1 on page 5 shows where the PROGRAM MC1 and PROGRAM DIP switches are located on the front panel. Refer to Wiring the DB-9 Connector for a DB-9 wiring diagram and pinouts.
Refer to the PROGRAM RS-232 DIP Switch Settings section on page 6 for communication settings.
3. Launch the AXCESS software program, select the appropriate AXCESS software program, and download it into the AXB-MPE+. Refer to the AXCESS Programming Language instruction manual for detailed programming and downloading information. 4. Connect your PC to the DB-9 connector on the rear of the AXB-MPE+ to program the AXC-EM Master Card 2 (MC2). Then, perform step 3 to program the card.
12
AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander
Installation and Configuration
AXB-MPE+ Master Port Expander and AXB-SPE Slave Port Expander
13
AMX reserves the right to alter specifications without notice at any time.
brussels · dallas · los angeles · mexico city · philadelphia · shanghai · singapore · tampa · toronto* · york 3000 research drive, richardson, TX 75082 USA · 469.624.8000 · 800.222.0193 · fax 469.624.7153 · technical support 800.932.6993
032-004-1019 4/02 ©2002 AMX Corporation. All rights reserved. AMX, the AMX logo, the building icon, the home icon, and the light bulb icon are all trademarks of AMX Corporation. AMX reserves the right to alter specifications without notice at any time. *In Canada doing business as Panja Inc.
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AMX AXB-MPE+. AMX offer a product for which we do not have the user manual? Let us know what you are looking for: user guide, owner's manual, online manual, operating instructions, quick start guide, mounting instructions, schematics, service manual, installation instructions, RTFM. Diplodocs allows you to download user manual AMX AXB-MPE+, user guide AMX AXB-MPE+, instructions AMX AXB-MPE+, owner's manual AMX AXB-MPE+, online manual AMX AXB-MPE+.AMX AXB-MPE+, AMX CORPORATION, Router, Switch, Firewall & Other network security hardware. |
![]() |
Include the add-on to download manuals from your site, forum or blog | ![]() |
Frequently Asked Questions | ![]() |
Contact Diplodocs team | ![]() |
Last searches Last additions |
![]() |
Sitemap | ![]() |
|||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |