Download user guide, user manual, owner manual and instructions guide
5 600 brands
1 870 000 user's guides
Search a brand
Advanced Search



Our partners wish to propose you the following products


Visit AMX official site

User manual AMX AXC-TEMP AND RTS-1 TEMPERATURE CONTROL CARD AND ROOM TEMPERATURE SENSOR

Diplodocs help download the user guide AMX AXC-TEMP AND RTS-1 TEMPERATURE CONTROL CARD AND ROOM TEMPERATURE SENSOR.



Download the user manual AMX AXC-TEMP AND RTS-1 TEMPERATURE CONTROL CARD AND ROOM TEMPERATURE SENSOR  
Download the complete
user guide (447 Ko)
Need help, support, reviews, tips or troubleshooting for your AMX AXC-TEMP AND RTS-1 TEMPERATURE CONTROL CARD AND ROOM TEMPERATURE SENSOR products ?

This product, although classified under the brand AMX, may have been manufactured by PROCON after mergers, acquisitions, or a change in name.

Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
User guide AMX AXC-TEMP AND RTS-1 TEMPERATURE CONTROL CARD AND ROOM TEMPERATURE SENSOR

Detailed instructions for use are in the User's Guide.

instruction manual AXC-TEMP Temperature Control Card and RTS-1 Room Temperature Sensor Axcess Control Cards Limited Warranty and Disclaimer AMX Corporation warrants its products to be free from defects in material and workmanship under normal use for a period of three years from date of purchase from AMX Corporation, with the following exceptions. Electroluminescent and LCD control panels are warranted for a period of three years, except for the display and touch overlay components which are warranted for a period of one year. Disk drive mechanisms, pan/tilt heads, power supplies, modifications, MX Series products, and KC Series products are warranted for a period of one year. Unless otherwise specified, OEM and custom products are covered for a period of one year. AMX Corporation software products are warranted for a period of 90 days. Batteries and incandescent lamps are not covered. This warranty extends to products purchased directly from AMX Corporation or an authorized AMX Corporation dealer. Consumers should inquire from selling dealer as to the nature and extent of the dealer's warranty, if any. AMX Corporation is not liable for any damages caused by its products or for the failure of its products to perform, including any lost profits, lost savings, incidental damages, or consequential damages. AMX Corporation is not liable for any claim made by a third party or made by you for a third party. This limitation of liability applies whether damages are sought, or a claim is made, under this warranty or as a tort claim (including negligence and strict product liability), a contract claim, or any other claim. This limitation of liability cannot be waived or amended by any person. This limitation of liability will be effective even if AMX Corporation or an authorized representative of AMX Corporation has been advised of the possibility of any such damages. This limitation of liability, however, will not apply to claims for personal injury. Some states do not allow a limitation of how long an implied warranty lasts. Some states do not allow the limitation or exclusion of incidental or consequential damages for consumer products. In such states, the limitation or exclusion of the Limited Warranty may not apply to you. This Limited Warranty gives you specific legal rights. You may also have other rights that may vary from state to state. You are advised to consult applicable state laws for full determination of your rights. EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY, AMX CORPORATION MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. AMX CORPORATION EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY. ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF THIS LIMITED WARRANTY. Table of Contents Table of Contents Product Information .................................................................................................1 Features ............................................................................................................................ 1 Pre-Installation ..........................................................................................................3 Setting Fahrenheit or Celsius ............................................................................................ 3 Setting the Jumpers ................................................................................................................. 3 Calibrating POTs ............................................................................................................... 4 Connecting Multiple RTS1s............................................................................................... 4 RTS1 Preparation.............................................................................................................. 5 Wiring the RTS1....................................................................................................................... 5 RTS1 Calibration ............................................................................................................... 6 Testing the RTS1 .............................................................................................................. 7 Programming ............................................................................................................9 AXC-TEMP Temperature Control Card and RTS1 Room Temperature Sensor i Table of Contents ii AXC-TEMP Temperature Control Card and RTS1 Room Temperature Sensor Product Information Product Information The AXC-TEMP Temperature Control card (FIG. 1) provides control and power for the RTS1 Room Temperature Sensor (FIG. 2). The RTS1 provides precision temperature sensing for the AXT-TEMP. FIG. 1 AXC-TEMP FIG. 2 RTS1 Features The AXC-TEMP features include: ! ! ! ! ! Standard Axcess CardFrame slot size Settings for Fahrenheit or Celsius operation Control and power for up to four independent RTS1 units Measurement accuracy of +/- 2°F (+/- 1.1°C) Calibration for zero temperature deviation The RTS1 features include: ! ! Precise temperature measurement from 5× to 128°F (-29.2× to +106.9°C) Connection to the AXC-TEMP card with a shielded 3-conductor cable AXC-TEMP Temperature Control Card and RTS1 Room Temperature Sensor 1 Product Information The table below lists the specifications for the AXC-TEMP and RTS1. Specifications AXC-TEMP Input voltage Current Draw Temperature range Accuracy Resolution +12 to 18 VDC 40 mA (using four RTS1s = 75 mA) 0.0 ° F to +250 ° F (0.0 ° C to +106.9 ° C) +/-2 ° F (+/-1.1 ° C) 10-bit (1024 steps over range) RTS1 Weight Dimensions Enclosure Resolution Temperature range 3.2 oz. (91 grams) 4.5" x 2.75" x 9" (114 mm x 70 mm x 23 mm) Metal, off-white finish 10-bit (1024 steps over range) -20.5°F to +250°F (-29.2°C to 106.9°C) 2 AXC-TEMP Temperature Control Card and RTS1 Room Temperature Sensor Pre-Installation Pre-Installation Before installing the AXT-TEMP and RTS1, you must properly set jumpers and potentiometers (POTs). Setting Fahrenheit or Celsius Set the Fahrenheit or Celsius feature by manually selecting each jumper (JP1- JP4) or by manually selecting the RAW A/D OUTPUT jumper on the card. FIG. 3 shows the location of the jumpers and POTs. The RAW A/D OUTPUT jumper overrides jumpers JP1 - JP4. Channels 1 - 4 Jumpers JP5 - JP8 Jumpers JP1 - JP4 and JP13 (RAW) FIG. 3 Location of jumpers and POTs Jumpers JP9 - JP12 Setting the Jumpers Use the two-position jumpers (FIG. 4) to select Fahrenheit or Celsius operation. The setting takes effect when you power on the system or reinsert the card into the CardFrame. The default setting is Fahrenheit (°F). °F °C JP1 FIG. 4 Jumpers 1. Set each jumper (JP1 - JP4) on the card for either Fahrenheit or Celsius. 2. Set all calibration POTs to zero. Each POT is a 25 turn POT. Full counter-clockwise is a -4° variance and full clockwise is a +4° variance. To access the jumper and POTs, remove the AXC-TEMP card from the CardFrame. After making all adjustments, be sure to reseat the card properly. You can also adjust the card using an optional Axcess Extender Card (AXC-EXTN), for easier access. 3. Insert the card into the desired Axcess CardFrame slot. It is not necessary to disconnect power to the CardFrame when installing the card. AXC-TEMP Temperature Control Card and RTS1 Room Temperature Sensor 3 Pre-Installation 4. Hold the card by the tab end and slide the card into the frame. Make sure the card is correctly positioned in the guide slot. 5. Gently push the card in until it is firmly seated in the card connector slot. It is not necessary to disconnect the power to the CardFrame when installing the card. Calibrating POTs Use the four calibration potentiometers (POTs), marked CH 1 - CH 4, to adjust the respective RTS1 units 1 - 4. The default setting for each POT pointer is 0°. The table below describes the POT calibration for CH 1 - CH 4. Calibration POTs CH1 - CH4 POTs R1 R8 R2 R9 R33 R34 R35 R36 Description Offsets input CHAN1 by -4 to +4 degrees Offsets input CHAN 2 by -4 to +4 degrees Offsets input CHAN 3 by -4 to +4 degrees Offsets input CHAN 4 by -4 to +4 degrees Stops Adj for input CHAN 1 (for RTS2 only) Stops Adj for input CHAN 2 (for RTS2 only) Stops Adj for input CHAN 3 (for RTS2 only) Stops Adj for input CHAN 4 (for RTS2 only) Connecting Multiple RTS1s FIG. 5 shows the pinout for the AXC-TEMP when connecting multiple RTS1s. PIN 1 GND IN1 PWR GND IN2 PWR GND IN3 PWR GND IN4 PWR PIN 16 FIG. 5 AXC-TEMP pinout for multiple RTS1s TO RTS1 #1 TO RTS1 #2 TO RTS1 #3 TO RTS1 #4 4 AXC-TEMP Temperature Control Card and RTS1 Room Temperature Sensor Pre-Installation RTS1 Preparation To install the RTS1 units: 1. Wire RTS1 units 1 - 4. Refer to Wiring the RTS1 for additional information. 2. Check the temperature. ! If the panel has a display, check the temperature readings on the system Wiring control panel. The temperature readings will change when the room temperature changes by a half degree. If the panel does not have a display, check the variables in Axcess. ! Wiring the RTS1 Use Belden 8723 or equivalent cable. When an application or code requires plenum-rated cable, use Belden 88723 or equivalent cable. Call AMX Technical Support for any installations that require a wire run of more than 100 feet. RTS1 depth is 0.9" (22.9 mm) with the front cover installed 2.75" (69.9 mm) w/ front cover on Wire feed hole RTS1 backplate From left to right: GND, OUT, PWR 4.5" (114.3 mm) AXlink connector RTS1 circuit board FIG. 6 RTS1 circuit connections AXC-TEMP Temperature Control Card and RTS1 Room Temperature Sensor 5 Pre-Installation Axcess CardFrame AXC-TEMP Ground Black 1 Drain Green 2 Input White 3 4 5 6 7 8 9 Ground Black Drain Green Input White Power Red Ground Black Drain Green Input White Power Red Power Red Belden 8723, or equivalent (Twisted Pair) Black Ground Drain Green White Output Red Power RTS1 Unit 1 Belden 8723, or equivalent (Twisted Pair) Black Ground Drain Green White Output Red Power RTS1 Unit 2 10 11 12 13 14 15 16 Belden 8723, or equivalent (Twisted Pair) Black Ground Drain Green White Output Red Power RTS1 Unit 3 Ground Black Drain Green Input White Power Red Belden 8723, or equivalent (Twisted Pair) Black Ground Drain Green White Output Red Power RTS1 Unit 4 FIG. 7 RTS1 to Axcess Cardframe connections RTS1 Calibration To calibrate the RTS1: 1. Place a reference thermometer near RTS1 unit 1. 2. Allow the reference thermometer to stabilize for approximately 1-minute. 3. Adjust calibration POT R1 (CHAN 1) clockwise or counter-clockwise to match the reference thermometer temperature. When connecting wiring, ensure the Drain and Green wires are used. The capacitance/filtering effects of these wires are required for accurate measurements. 4. Touch the sensor at bottom of RTS1 unit 1 for 2-seconds to force a temperature change. 5. Wait approximately 5 seconds for the temperature to stabilize. Then, recheck the display panel temperature display. Allow the reference thermometer to stabilize approximately one minute, then check. 6. If necessary, repeat steps 1 - 5 for RTS1 units 2 - 4, and move the reference thermometer near each sensor you are calibrating. 6 AXC-TEMP Temperature Control Card and RTS1 Room Temperature Sensor Pre-Installation Testing the RTS1 Touch the sensor at the bottom each RTS1 unit for a few seconds. The temperature on the display panel should change. If the temperature does not change: 1. Check the wiring to each RTS1 unit that did not display a temperature change. 2. Verify the AXC-TEMP card is properly seated in the CardFrame. Repeat the steps provided in the RTS1 Calibration section on page 6, if required. AXC-TEMP Temperature Control Card and RTS1 Room Temperature Sensor 7 Pre-Installation 8 AXC-TEMP Temperature Control Card and RTS1 Room Temperature Sensor Programming Programming This section provides the Axcess programming commands for the AXC-TEMP and RTS1. ! ! The TEMP_LEVEL variable receives data from the TEMP card (Device 16), inputs 1 - 4. The data is in three-digit numbers (986 = 98.6 degrees). The SEND_STRING command to the Mini-LCD Panel converts the number to print with a decimal point. The 12 clears the LCD screen. DEFINE_DEVICE TEMP = 16 DEFINE_VARIABLE TEMP_LEVEL1 TEMP_LEVEL2 TEMP_LEVEL3 TEMP_LEVEL4 DEFINE_START CREATE_LEVEL TEMP,1,TEMP_LEVEL1 CREATE_LEVEL TEMP,2,TEMP_LEVEL2 CREATE_LEVEL TEMP,3,TEMP_LEVEL3 CREATE_LEVEL TEMP,4,TEMP_LEVEL4 DEFINE_PROGRAM WAIT 10 { SEND_STRING LCD,"12,ITOA(TEMP_LEVEL1/ 10),'.',ITOA(TEMP_LEVEL1%10)" } ! A UPD command forces the card to update or send all levels to Axcess Master Card (AXC-EM) For additional information, refer to the Axcess Programming Language instruction manual. AXC-TEMP Temperature Control Card and RTS1 Room Temperature Sensor 9 031-004-1029 3/04 ©2004 AMX Corporation. All rights reserved. AMX, the AMX logo, the building icon, the home icon, and the light bulb icon are all trademarks of AMX Corporation. In Canada doing business as Panja Inc. AMX reserves the right to alter specifications without notice at any time. ARGENTINA · AUSTRALIA · BELGIUM · BRAZIL · CANADA · CHINA · ENGLAND · FRANCE · GERMANY · GREECE · HONG KONG · INDIA · INDONESIA · ITALY · JAPAN LEBANON · MALAYSIA · MEXICO · NETHERLANDS · NEW ZEALAND · PHILIPPINES · PORTUGAL · RUSSIA · SINGAPORE · SPAIN · SWITZERLAND · THAILAND · TURKEY · USA ATLANTA · BOSTON · CHICAGO · CLEVELAND · DALLAS · DENVER · INDIANAPOLIS · LOS ANGELES · MINNEAPOLIS · PHILADELPHIA · PHOENIX · PORTLAND · SPOKANE · TAMPA 3000 RESEARCH DRIVE, RICHARDSON, TX 75082 USA · 800.222.0193 · 469.624.8000 · 469-624-7153 fax · 800.932.6993 technical support · www.amx.com Last Revision: 08/03/04

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AMX AXC-TEMP AND RTS-1 TEMPERATURE CONTROL CARD AND ROOM TEMPERATURE SENSOR.

AMX offer a product for which we do not have the user manual? Let us know what you are looking for: user guide, owner's manual, online manual, operating instructions, quick start guide, mounting instructions, schematics, service manual, installation instructions, RTFM.

Diplodocs allows you to download user manual AMX AXC-TEMP AND RTS-1 TEMPERATURE CONTROL CARD AND ROOM TEMPERATURE SENSOR, user guide AMX AXC-TEMP AND RTS-1 TEMPERATURE CONTROL CARD AND ROOM TEMPERATURE SENSOR, instructions AMX AXC-TEMP AND RTS-1 TEMPERATURE CONTROL CARD AND ROOM TEMPERATURE SENSOR, owner's manual AMX AXC-TEMP AND RTS-1 TEMPERATURE CONTROL CARD AND ROOM TEMPERATURE SENSOR, online manual AMX AXC-TEMP AND RTS-1 TEMPERATURE CONTROL CARD AND ROOM TEMPERATURE SENSOR.


AMX AXC-TEMP AND RTS-1 TEMPERATURE CONTROL CARD AND ROOM TEMPERATURE SENSOR, AMX CORPORATION, Router, Switch, Firewall & Other network security hardware.
Include the add-on to download manuals from your site, forum or blog Frequently Asked Questions Contact Diplodocs team Last searches
Last additions
Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.