User manual AMX AXP-CPI16 CUSTOM PANEL INTERFACE BOARD (16 BUTTONS)
Diplodocs help download the user guide AMX AXP-CPI16 CUSTOM PANEL INTERFACE BOARD (16 BUTTONS) .
This product, although classified under the brand AMX, may have been manufactured by PROCON after mergers, acquisitions, or a change in name.
Preview of the first 3 pages of manual
You either have JavaScript turned off or an old version of Adobe Flash Player Get the latest Flash Player.
Manual abstract: user guide AMX AXP-CPI16 CUSTOM PANEL INTERFACE BOARD (16 BUTTONS)
Detailed instructions for use are in the User's Guide. Operation/Reference Guide
AXP-CPI16
16-Channel Custom Panel Interface
Custom Panel Interfaces
Document ID: 038-004-1334 Last Revised: 8/16/2006
AMX Limited Warranty and Disclaimer
AMX warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX, with the following exceptions: · · · Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year. Disk drive mechanisms, pan/tilt heads, power supplies, and MX Series products are warranted for a period of one (1) year. AMX Lighting products are guaranteed to switch on and off any load that is properly connected to our lighting products, as long as the AMX Lighting products are under warranty. AMX does guarantee the control of dimmable loads that are properly connected to our lighting products. The dimming performance or quality cannot be guaranteed due to the random combinations of dimmers, lamps and ballasts or transformers. Unless otherwise specified, OEM and custom products are warranted for a period of one (1) year. AMX Software is warranted for a period of ninety (90) days. Batteries and incandescent lamps are not covered under the warranty.
· · ·
This warranty extends only to products purchased directly from AMX or an Authorized AMX Dealer. All products returned to AMX require a Return Material Authorization (RMA) number. The RMA number is obtained from the AMX RMA Department. The RMA number must be clearly marked on the outside of each box. The RMA is valid for a 30-day period. After the 30-day period the RMA will be cancelled. Any shipments received not consistent with the RMA, or after the RMA is cancelled, will be refused. AMX is not responsible for products returned without a valid RMA number. AMX is not liable for any damages caused by its products or for the failure of its products to perform. This includes any lost profits, lost savings, incidental damages, or consequential damages. AMX is not liable for any claim made by a third party or by an AMX Dealer for a third party. This limitation of liability applies whether damages are sought, or a claim is made, under this warranty or as a tort claim (including negligence and strict product liability), a contract claim, or any other claim. This limitation of liability cannot be waived or amended by any person. This limitation of liability will be effective even if AMX or an authorized representative of AMX has been advised of the possibility of any such damages. This limitation of liability, however, will not apply to claims for personal injury. Some states do not allow a limitation of how long an implied warranty last. Some states do not allow the limitation or exclusion of incidental or consequential damages for consumer products. In such states, the limitation or exclusion of the Limited Warranty may not apply. This Limited Warranty gives the owner specific legal rights. The owner may also have other rights that vary from state to state. The owner is advised to consult applicable state laws for full determination of rights. EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY, AMX MAKES NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. AMX EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY. ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF THIS LIMITED WARRANTY.
Table of Contents
Table of Contents
Product Information ...........................................................................................1
Specifications............................................................................................................ 1
Installation ..........................................................................................................5
Mounting Dimensions ............................................................................................... 5 Setting the AXlink Device Number ........................................................................... 6
Preparing/connecting captive wires ................................................................................ 6
Connecting the Two 20-pin Headers ........................................................................ 6 Switch Wiring Diagrams............................................................................................ 7 Connecting the AXlink Wiring................................................................................... 7
Programming ......................................................................................................9
Testing the Unit ...................................................................................................... 10
AXP-CPI16 System Worksheet .........................................................................11
AXP-CPI16 16-Channel Custom Panel Interface
i
Table of Contents
ii
AXP-CPI16 16-Channel Custom Panel Interface
Product Information
Product Information
The AMX AXP-CPI16 16 Channel Custom Panel Interface Board (FIG. 1) simplifies the process of creating custom control panels for Axcess systems. Providing contact closure inputs and feedback outputs for up to 16 buttons, the miniature PC board contains a 20-pin header for ribbon cable installation or for direct mounting to a printed circuit board.
AXlink Connector Pin 1 20-Pin Header P3 Connect this side to the ribbon cable
Pin 1
Device DIP Switch
AXlink Status LED -Pin Header P2 onnect this side to the ribbon cable FIG. 1 AXP-CPI16 components Connect this side to the PC board
Specifications
The following table lists product specifications for the AXP-CPI16.
AXP-CPI16 Specifications
Dimensions (HWD) Power Inputs Outputs 2.75" x 1.75" x 0.062" (69.90 mm x 44.50 mm x 1.557 mm) · Input voltage: 12 VDC (nominal) · Current draw: 25mA 16 closure inputs with a common ground (GND) 16 open-collector outputs, acting as switch to ground, up to 100 mA DC each for: · Board is not to supply more than 750 mA of +12V total. · Small incandescent lamps · LED indicators - with series resistor (1K for 12 VDC) · Relays - with DC coil AXlink Connector Headers A 4-pin (male) connector attached to a four-wire cable which sends control data from the Axcess CardFrame to the AXP-CPI16. Two 20-pin headers included for ribbon cables (up to 100 feet each) or for mounting directly to a PC board.
AXP-CPI16 16-Channel Custom Panel Interface
1
Product Information
AXP-CPI16 Specifications (Cont.)
AXlink Status LED Indicates AXlink communication status as follows: · One blink per second communication is functioning. · Two blinks per second devices specified in the master program do not match the specified devices found. · Three blinks per second indicate an AXlink communication error. · Full-on indicates there is no AXlink control or activity (but power is on), or the Axcess program is not loaded. Device DIP Switch Cables 8-position DIP switch sets AXlink device ID. Two 3-foot (91.4 cm) ribbon cables each with a female 20-pin header.
2
AXP-CPI16 16-Channel Custom Panel Interface
Product Information
OFF OFF ON ON 12345 678
AXP-CPI16 16-Channel Custom Panel Interface
3
Product Information
4
AXP-CPI16 16-Channel Custom Panel Interface
Installation
Installation
Mounting Dimensions
B B A A A C C AXlink AXlink AXP GND PWR AXP AXM GND
LH
L J
A
P1
PWR AXM
P1
12 12
P3 P3
Top View
D D
E E
Top View (Component Side)
(Component Side)
19 20 19 20
MM
2 1 F F
P2 P2
20 20 19 19
J G G K K min min
H
FIG. 1 AXP-CPI16 mounting dimensions
Mounting Dimensions
Item Inch A B C D E F G H J 0.10 1.75 1.55 2.75 2.55 0.35 0.23 0.93 mm 2.50 Item Description K P2 20-Pin Header .025 inch (6 mm) square pins, .1 inch (2.4 mm) typical spacing 0.125 Inch (3.2 mm) mounting holes for #4-40 (3 mm) screws P3 20-Pin Header .025 inch (6 mm) square pins, .1 inch (2.4 mm) typical spacing
44.50 L 39.40 M 69.90 64.80 8.90 5.80 23.6
0.438 11.10
AXP-CPI16 16-Channel Custom Panel Interface
5
Installation
Setting the AXlink Device Number
The 8-position device DIP switch defines the AXP-CPI16 as an AXlink device. It can be one of 255 devices in the Axcess Control System. Set the device number with the total value of all ON (down) positions. As an example, the device DIP switch shown below defines device number 129 (1+128=129).
Position 1 2 3 4 5 Value 6 7 8
OFF OFF ON ON 12345 678
1 2 4 8 16 32 64 128
AMX standard device numbers are assigned as follows: Cards are 1 through 25. Boxes are 96 through 127. Panels are 128 through 255.
Preparing/connecting captive wires 1. Strip 0.25 inch of wire insulation off all wires. 2. Insert each wire into the appropriate opening on the connector according to the wiring diagrams and connector types described in this section. 3. Tighten the screws to secure the wires. Do not tighten the screws excessively; doing so may strip the threads and damage the connector.
Connecting the Two 20-pin Headers
The following chart notes the pinouts of the two 20-pin headers for P2 and P3.
AXP-CPI16 P2/P3 Pinouts
P2 1 2 3 4 5 6 7 8 9 10 Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 GND PWR 11 12 13 14 15 16 17 18 19 20 GND GND Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 Input 8 P3 1 2 3 4 5 6 7 8 9 10 Output 9 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 GND PWR 11 12 13 14 15 16 17 18 19 20 GND GND Input 9 Input 10 Input 11 Input 12 Input 13 Input 14 Input 15 Input 16 Pin Function Pin Function Pin Function Pin Function
Pin 10 provides +12 VDC power from AXlink bus. Add 1K series resistors when using AXP-CPI16 with LED indicators receiving 12 VDC power from Pin 10.
6
AXP-CPI16 16-Channel Custom Panel Interface
Installation
Switch Wiring Diagrams
FIG. 2 diagrams LED and Switch wiring.
LED Wiring (Typical) LED 1 LED 2 LED 3 1K 1K 1K 1 2 3
12 Switch Wiring (Typical) SW 1 SW 2 SW 3 13 14 15
10
FIG. 2 LED and switch wiring diagrams
Connecting the AXlink Wiring
To install the AXlink data/power bus wiring.
1. Strip 0.25 inch off the wire insulation for all four wires. If the wire is 20 AWG or less, fold the exposed wire over to obtain a positive connection. 2. Insert each wire into the appropriate opening on the connector, as shown in FIG. 3.
PWR AXlink AXP AXM GND FIG. 3 AXlink wiring diagram PWR AXP AXM GND Device
3. Tighten the screws to secure the fit.
AXP-CPI16 16-Channel Custom Panel Interface
7
Installation
8
AXP-CPI16 16-Channel Custom Panel Interface
Programming
Programming
Use the same Axcess commands as with other AXlink control panels, such as the AXU-MSP series mini-softwire panels. When using the AXP-CPI16 as a control device, use On, Off, and Pulse commands to control sources connected to outputs and Push and Release commands to receive inputs. For additional information, refer to the Axcess Programming Language instruction manual.
Send_Commands
Command 'STATUS-ON' Description Causes the AXP-CPI16 to be in Status-On Mode. This command overrides the mode setting. 'STATUS-OFF' Causes the AXP-CPI16 to be in Status-Off Mode. This command overrides the mode setting.
The AXP-CPI16 uses input channels to report user input on the contacts or switches attached to the input terminals. Output channels are used to turn on the lamp or LED display devices to indicate the button status to the user. The AXP-CPI16 default mode is STATUS-OFF, and in this mode the programmer cannot poll the AXPCPI16 to determine the state of the output channel. This is because in this mode the output and input channels use the same number assignments. Inputs are sent by the AXP-CPI16 only as input changes. When set for STATUS-ON mode the output channels are assigned a different channel number than the input channels. This allows the programmer to monitor the status of an output channel. However the channel offset must be accommodated in the programming code. Statements such as this example can be used in a program.
IF[CPI16,25] (* output channel assigned to input channel 9 on P3 connector *)
Each of the two 20-pin connectors is assigned a group of 8 input and output channels. The table below shows the relation of input and output channels in the STATUS modes.
Input/Output STATUS Mode
Mode Inputs Outputs Connector P2 P3 P2 P3 STATUS-OFF (default) Chan 1-8 (Push/Release only) Chan 9-16 (On/Off only) Chan 1-8 (Push/Release only) Chan 9-16 (On/Off only) STATUS-ON Chan 1-8 (On/Push/Off/Release) Chan 17-24 (On/Off) Chan 9-16 (On/Push/Off/Release) Chan 25-32 (On/Off)
The AXP-CPI16 may be configured to default to STATUS-ON mode using the following method. The commands can force a change to the mode no matter what default mode is configured for the device. STATUS-ON Mode: Remove R7 (1K ohm) resistor OR short across R8 for STATUS-ON mode. Firmware remains the same for st ...
|