Download user guide, user manual, owner manual and instructions guide
5 600 brands
1 870 000 user's guides
Search a brand
Advanced Search



Our partners wish to propose you the following products


Visit AMX official site

User manual AMX NXA-UPS1500 UNINTERRUPTIBLE POWER SUPPLY

Diplodocs help download the user guide AMX NXA-UPS1500 UNINTERRUPTIBLE POWER SUPPLY.



Download the user manual AMX NXA-UPS1500 UNINTERRUPTIBLE POWER SUPPLY  
Download the complete
user guide (1764 Ko)
Need help, support, reviews, tips or troubleshooting for your AMX NXA-UPS1500 UNINTERRUPTIBLE POWER SUPPLY products ?

This product, although classified under the brand AMX, may have been manufactured by PROCON after mergers, acquisitions, or a change in name.

Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
User guide AMX NXA-UPS1500 UNINTERRUPTIBLE POWER SUPPLY

Detailed instructions for use are in the User's Guide.

Operation/Reference Guide NXA-UPS1500 Uninterruptible Power Supply US version (110 Vac) Int'l version (220 Vac) Last Revised: 11/17/2006 AMX Limited Warranty and Disclaimer AMX warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX, with the following exceptions: · · · Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year. Disk drive mechanisms, pan/tilt heads, power supplies, and MX Series products are warranted for a period of one (1) year. AMX Lighting products are guaranteed to switch on and off any load that is properly connected to our lighting products, as long as the AMX Lighting products are under warranty. AMX does guarantee the control of dimmable loads that are properly connected to our lighting products. The dimming performance or quality cannot be guaranteed due to the random combinations of dimmers, lamps and ballasts or transformers. Unless otherwise specified, OEM and custom products are warranted for a period of one (1) year. AMX Software is warranted for a period of ninety (90) days. Batteries and incandescent lamps are not covered under the warranty. · · · This warranty extends only to products purchased directly from AMX or an Authorized AMX Dealer. All products returned to AMX require a Return Material Authorization (RMA) number. The RMA number is obtained from the AMX RMA Department. The RMA number must be clearly marked on the outside of each box. The RMA is valid for a 30-day period. After the 30-day period the RMA will be cancelled. Any shipments received not consistent with the RMA, or after the RMA is cancelled, will be refused. AMX is not responsible for products returned without a valid RMA number. AMX is not liable for any damages caused by its products or for the failure of its products to perform. This includes any lost profits, lost savings, incidental damages, or consequential damages. AMX is not liable for any claim made by a third party or by an AMX Dealer for a third party. This limitation of liability applies whether damages are sought, or a claim is made, under this warranty or as a tort claim (including negligence and strict product liability), a contract claim, or any other claim. This limitation of liability cannot be waived or amended by any person. This limitation of liability will be effective even if AMX or an authorized representative of AMX has been advised of the possibility of any such damages. This limitation of liability, however, will not apply to claims for personal injury. Some states do not allow a limitation of how long an implied warranty last. Some states do not allow the limitation or exclusion of incidental or consequential damages for consumer products. In such states, the limitation or exclusion of the Limited Warranty may not apply. This Limited Warranty gives the owner specific legal rights. The owner may also have other rights that vary from state to state. The owner is advised to consult applicable state laws for full determination of rights. EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY, AMX MAKES NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. AMX EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY. ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF THIS LIMITED WARRANTY. Table of Contents Table of Contents NXA-UPS1500 Uninterruptible Power Supply ....................................................1 Overview .................................................................................................................. 1 Features.................................................................................................................... 1 Product Specifications ............................................................................................. 2 Front Panel LCD........................................................................................................ 3 IMPORTANT SAFETY INSTRUCTIONS ................................................................5 Important Notice ...................................................................................................... 5 Storage Instructions.................................................................................................. 5 Setting Up The NXA-UPS1500 ...........................................................................7 Place the UPS Properly ............................................................................................. 7 Unpacking................................................................................................................. 7 Accessories for Tower and Rack Mount .......................................................................... 7 Selecting Installation Position ................................................................................... 8 UPS Setup................................................................................................................. 8 Tower Setup ............................................................................................................. 9 Tower Setup - Step One ................................................................................................. 9 Tower Setup - Step Two ................................................................................................. 9 Rack-Mount Setup .................................................................................................. 10 Rack-Mount Setup - Step One ...................................................................................... 10 Rack-Mount Setup - Step Two ...................................................................................... 10 Rack-Mount Setup - Step Three ................................................................................... 11 Rack-Mount Setup - Step Four ..................................................................................... 11 Rack-Mount Setup - Step Five ...................................................................................... 12 Installation ........................................................................................................13 Connect Utility and Load ........................................................................................ 13 Connect Network Surge Protection........................................................................ 14 Connect the RS-232 Communication Port............................................................... 14 RS-232 Communication Port Pin Assignment ................................................................ 15 Operation .........................................................................................................17 Turn On the UPS ..................................................................................................... 17 Turn Off the UPS..................................................................................................... 17 Plug-In Charge ........................................................................................................ 17 Auto-Restart ........................................................................................................... 17 Alarm Silence .......................................................................................................... 17 Self Test .................................................................................................................. 17 NXA-UPS1500 Uninterruptible Power Supply i Table of Contents Battery Replacement ........................................................................................19 Overview ................................................................................................................ 19 Assembling the Battery Pack......................................................................................... 19 Replacing the UPS Battery - Step One ......................................................................... 20 Replacing the UPS Battery - Step Two ......................................................................... 21 Replacing the UPS Battery - Step Three ....................................................................... 21 Recycling the Used Battery ........................................................................................... 21 NXA-UPS1500 EPM Installation ........................................................................23 Overview ................................................................................................................ 23 IMPORTANT SAFETY INSTRUCTIONS .................................................................... 23 SAVE THESE INSTRUCTIONS ........................................................................................ 23 IMPORTANT NOTICE .................................................................................................... 24 EPM Specifications.................................................................................................. 24 EPM - Installation and Operation ............................................................................ 25 Unpacking ..................................................................................................................... 25 Selecting Installation Position........................................................................................ 25 EPM Installation Instructions................................................................................... 26 Tower Installation - Step One ....................................................................................... 26 Tower Installation - Step Two ....................................................................................... 26 Using the EPM With The UPS.................................................................................. 27 Use With UPS - Step One Use With UPS - Step Two ........................................................................................... 27 ........................................................................................... 27 EPM - Rack Mount Installation ................................................................................ 28 Rack Mount Installation - Step One .............................................................................. 28 Rack Mount Installation - Step Two .............................................................................. 28 Rack Mount Installation - Step Three ............................................................................ 29 Rack Mount Installation - Step Four ............................................................................. 29 Connecting the EPM To the UPS ............................................................................ 30 EPM - Storage Instructions ..................................................................................... 30 Replacing the Battery In the EPM ........................................................................... 31 Replacing the Battery in the EPM - Step One .............................................................. 31 Replacing the Battery in the EPM - Step Two .............................................................. 31 Replacing the Battery in the EPM - Step Three ............................................................ 32 Replacing the Battery in the EPM - Step Four .............................................................. 32 ii NXA-UPS1500 Uninterruptible Power Supply NXA-UPS1500 Uninterruptible Power Supply NXA-UPS1500 Uninterruptible Power Supply Overview The NXA-UPS1500 is an Uninterruptible Power Supply (UPS) featuring Double AVR Boost and Double Buck, Pure Sine Wave Output, LCD Display and Hot-Swappable Battery. The NXA-UPS1500 supports RS232 control. The NXA-UPS1500 UPS is available in two models - the 120V version (FG678-15) is suitable for use in the US, and the 220V version (FG678-20), for International usage. The NXA-UPS1500 features tower/rack-convertible design making it ideal for use with AMX's line of MAX devices (FIG. 1). Release tabs Battery Compartment Front Panel LCD (front) RS232 Communication Port Input Breaker Output Breaker (rear) USB Communication Port DIP Switch FIG. 1 NXA-UPS1500 Uninterrupted Power Supply Power Outlets Input Power Socket (Inlet) External Battery Terminal RJ-45 Ports (Network Surge Protection) Features Sine Wave Output provides assurance of compatibility with all kinds of loads. LCD panel displays system status including load level, battery level, AVR-Boost/Buck and fault status for easy service. 90% High Efficiency in Normal Mode meets high energy saving standard and reduces noise and heat generated by other topology UPS. Easy Swappable Battery Function may save the time and money by swapping the batteries by end-user without sending it back for a factory service. Cold Start Function enables to turn on the UPS without connecting to the Utility. User-friendly Plug and Play design can easily be installed. The NXA-UPS1500 EPM Extended Power Module (FG 678-15), available as an optional accessory, works with the NXA-UPS1500 to increase the duration of backup power, providing up to 3X additional battery run time. NXA-UPS1500 Uninterruptible Power Supply 1 NXA-UPS1500 Uninterruptible Power Supply Product Specifications NXA-UPS1500 Product Specifications Available Models: Input: Voltage Window: (DIP Switch selectable) Frequency Output: Voltage Window (AC Mode): · US version - 110/115/120 Vac +8% ~ -12% · Int'l version - 220/230/240 Vac +8% ~ -12% Voltage Window (INV Mode): US version - 110/115/120 Vac +/-5% Int'l version - 220/230/240 Vac +/-5% Capacity (VA/W): Wave Form: Frequency: Transfer Time: Autonomy: DC Start: Battery: Type: Capacity: Quantity: Voltage: Recharge Time: Storage: 12V, sealed lead acid maintenance-free 9AH 4 12V batteries required (included with the US/120V version) 24 Vdc 2 ~ 4 hours to 90% · Store at -15 to +30 °C (+5 to +86 °F), charge the UPS battery every 6 months. · Store at +30 to +45 °C (+86 to +113 °F), charge the UPS battery every 3 months. Display: LED: · Utility mode · Backup mode · Battery conditions LCD: · Load level (%) · Battery level (%) · Bypass · AVR-Boost/AVR Buck · Battery Low/Replace/Fault · UPS Fault · Site Wiring Fault · Overload 1500/900 Pure sine wave 50Hz/60Hz +/-0.1Hz 2 ms typical > 8 min. Yes · US version - 110/115/120 Vac +35% ~ -32% · Int'l version - 220/230/240 Vac +35% ~ -32% 45 ~ 65Hz (50/60Hz auto-sensing) · US version (110 Vac) - FG 678-15 · Int'l version (220 Vac) - FG 678-20 2 NXA-UPS1500 Uninterruptible Power Supply NXA-UPS1500 Uninterruptible Power Supply NXA-UPS1500 Product Specifications (Cont.) Protection: Overload: · AC Mode: >110% Buzzer continuously alarms, and shuts down in 10 minutes. · Inverter Mode: >120% Buzzer continuously alarms, and shuts down in 10 seconds. Self-Diagnostics: Short Circuit: Alarms: Audible and Visual: · Line Failure · Battery Low · Overload and Fault Environment: Operation Temperature: Operation Humidity: Dimensions (HWD): Control Communication: Certifications: Included Accessories 32° - 104°F (0-40° C) 95% RH Maximum, non-condensing · 3.46" x 17.32" x 18.97" (8.80cm x 44.0cm x 48.2 cm) · 2U rack height RS-232 · EN50091-1-1:1996 (Safety) · FCC Part 15, Subpart B - Class A · AC Input Power Cord · Four 12V batteries (57-0678-SA) - included with the US/120V version only · Tower and rack-mounting accessories Other AMX Equipment: · NXA-UPS1500 EPM Extended Power Module (FG 678-16) Upon Power-on · AC Mode: Breaker and electronic circuit · Inverter Mode: Shut down automatically in 8 cycles Front Panel LCD FIG. 2 describes the elements of the front panel LCD: 8 9 10 11 6 12 5 13 2 1. Utility (Green LED) 2. Fault (Red LED) 3. On Switch 4. Off Switch 5. Battery Replacement 6. Battery Backup (Amber LED) 7. Battery Low 8. Bypass 9. Utility Low, UPS Boost 10. Utility High, UPS Buck 11. UPS Output Indicator 12. Polarity Error or Ground Fault 13. Overload 14. Load/Battery Level (%) 15. Load/Battery Level Indication Control Button 1 7 14 3 4 15 6 2 1 FIG. 2 Elements Of The Front Panel LCD NXA-UPS1500 Uninterruptible Power Supply 3 NXA-UPS1500 Uninterruptible Power Supply 4 NXA-UPS1500 Uninterruptible Power Supply IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS Important Notice The UPS has its own internal energy source (battery). Should the battery be switched on when no AC power is available, there could be voltage at the output sockets. Make sure that the AC Utility outlet is correctly grounded. Do not open the case, as there are no serviceable parts inside. Your warranty will be void. Please make sure that the input voltage of the UPS matches the supply voltage. To eliminate any overheating of the UPS, keep all ventilation openings free from obstruction, and do not store "things" on top of the UPS. Keep the UPS 30cm away from the wall. Make sure the UPS is installed within the proper environment as specified (0-40° C and 3090% non-condensing humidity). Do install the UPS in direct sunlight. Install the UPS indoors as it is not designed for installation outdoors. Dusty, corrosive and salty environments can do damage to any UPS. Install the UPS away from objects that give off excessive heat and areas that are excessively wet. The battery will discharge naturally if the system is unused for any length of time. It should be recharged every 2-3 months if unused. When installed and being used, the batteries will be automatically recharged and kept in top condition. Do not install the UPS in an environment with sparks, smoke or gas. Make sure the UPS is completely turned off when moving the UPS from one place to another. It might cause electrical shock if the output is not cut completely. Storage Instructions For extended storage through moderate climate, the batteries should be charged for 12 hours every 3 months by plugging the UPS power cord into the wall receptacle and turn on input breaker on front panel. Repeat this procedure every 2 months under high temperature environment. NXA-UPS1500 Uninterruptible Power Supply 5 IMPORTANT SAFETY INSTRUCTIONS 6 NXA-UPS1500 Uninterruptible Power Supply Setting Up The NXA-UPS1500 Setting Up The NXA-UPS1500 Place the UPS Properly The UPS should be placed in a well-ventilated & low humid environment. Unpacking 1. Take the UPS out of the PE foam. 2. Remove the packing materials. 3. Standard Package includes: User's Manual AC Input Power Cord Accessories for Tower and Rack Mount Accessories for Tower and Rack Mount FIG. 3 shows the accessories for tower and rack-mounting the UPS: FIG. 3 Accessories for Tower and Rack Mount This unit may require at least two people to install due to its weight. NXA-UPS1500 Uninterruptible Power Supply 7 Setting Up The NXA-UPS1500 Selecting Installation Position It is necessary to select a proper environment to install the unit, in order to minimize the possibility of damage to the UPS and extend the life of the UPS (FIG. 4). · Keep at least 20cm (8") clearance from the rear panel of the UPS from the wall or other obstructions. · Do not block the air-flow to the ventilation openings of the unit. · Please ensure that the installation site environmental conditions are in accordance with the UPS working specifications to avoid overheat and excessive moisture. · Do not place the UPS in a dusty or corrosive environment or near any flammable objects. · This UPS is not designed for outdoor use. FIG. 4 Selecting Installation Position UPS Setup The UPS offers a flexible form factor enabling integration into a wide variety of environments (FIG. 5). The UPS with space-saving design only occupies 2 RU. FIG. 5 UPS Setup If you are installing the UPS in a tower, continue to the following section, "Tower Setup", otherwise; continue to "Rack-Mount Setup". 8 NXA-UPS1500 Uninterruptible Power Supply Setting Up The NXA-UPS1500 Tower Setup Tower Setup - Step One FIG. 6 Tower Setup - Step 1 Tower Setup - Step Two FIG. 7 Tower Setup - Step 2 NXA-UPS1500 Uninterruptible Power Supply 9 Setting Up The NXA-UPS1500 Rack-Mount Setup Rack-Mount Setup - Step One FIG. 8 Rack-Mounting the UPS. - Step 1 Rack-Mount Setup - Step Two FIG. 9 Rack-Mounting the UPS. - Step 2 10 NXA-UPS1500 Uninterruptible Power Supply Setting Up The NXA-UPS1500 In order to mount the NXA-UPS1500 into an equipment rack, you must use a rack shelf (not included with the UPS), as indicated in FIG. 10, FIG. 11 and FIG. 12. Rack-Mount Setup - Step Three Rack shelf required, not included with the UPS FIG. 10 Rack-Mounting the UPS. - Step 3 Rack-Mount Setup - Step Four FIG. 11 Rack-Mounting the UPS. - Step 4 NXA-UPS1500 Uninterruptible Power Supply 11 Setting Up The NXA-UPS1500 Rack-Mount Setup - Step Five FIG. 12 Rack-Mounting the UPS. - Step 5 12 NXA-UPS1500 Uninterruptible Power Supply Installation Installation Connect Utility and Load First, connect the UPS with Utility, then plug the loads into the Outlets on the rear of the UPS (FIG. 13). To use the UPS as a master "On/Off" switch, make sure that all of the loads are switched "on". These UPS outlets provide battery backup and surge protection to the equipment when Utility voltage is out of window. FIG. 13 Plug The Loads Into the UPS Do not connect a laser printer to the UPS outlets! NXA-UPS1500 Uninterruptible Power Supply 13 Installation Connect Network Surge Protection Connect a 10Base-T/100 Base-T network cable to the RJ45 network surge protection "IN" jack on the rear of the UPS. Connect from the "OUT" jack with network equipment (FIG. 14). FIG. 14 Connect Network Surge Protection If using the NXA-UPS1500 as part of a MAX system, do not run the A/V segment of the network through the RJ45 network surge protection jack on the UPS. The A/V segment of a MAX network requires a GB Ethernet switch, and the NXA-UPS1500 only provides a 10/100 connection. You can connect the Control segment of the MAX network to the UPS, since it does not require a GB connection to operate properly. Connect the RS-232 Communication Port Connect the supplied RS-232 interface cable between the RS-232 port on the rear of the UPS and an available RS-232 port on the NetLinx Master (FIG. 15). FIG. 15 Connect RS-232 Communication Port 14 NXA-UPS1500 Uninterruptible Power Supply Installation RS-232 Communication Port Pin Assignment The NXA-UPS1500 provides a DB9F (9-pin female) connector to communicate via RS-232. The pinout configuration for the RS-232 Communication Port connector is shown in FIG. 16: NetLinx UPS Pin 2: RX signal Pin 3: TX signal Pin 5: GND 5 4 3 2 1 9 8 9 8 7 6 7 6 5 4 3 2 1 Pin 2: TX signal Pin 3: RX signal Pin 5: GND (Male) RX (Pin 2) TX (Pin 3) GND (Pin 5) FIG. 16 RS-232 Communication Port Pin Assignment (Female) TX (Pin 2) RX (Pin 3) GND (Pin 5) RS-232 Communication Port Pin Assignment Pin 1 2 3 4 5 6 7 8 9 Assignment Description n/c UPS TX signal UPS RX signal n/c GND (ground) n/c n/c n/c n/c NXA-UPS1500 Uninterruptible Power Supply 15 Installation 16 NXA-UPS1500 Uninterruptible Power Supply

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AMX NXA-UPS1500 UNINTERRUPTIBLE POWER SUPPLY.

AMX offer a product for which we do not have the user manual? Let us know what you are looking for: site Internet, histoire, actualité, filiales, site Internet, mode d'emploi, driver, avis des utilisateurs, meilleur prix des produits, forum d'assistance aux problèmes, annuaire des marques, annuaire des constructeurs, répertoire des marques, répertoire des constructeurs, site Internet de la marque, site Internet du constructeur

Diplodocs allows you to download user manual AMX NXA-UPS1500 UNINTERRUPTIBLE POWER SUPPLY, user guide AMX NXA-UPS1500 UNINTERRUPTIBLE POWER SUPPLY, instructions AMX NXA-UPS1500 UNINTERRUPTIBLE POWER SUPPLY, owner's manual AMX NXA-UPS1500 UNINTERRUPTIBLE POWER SUPPLY, online manual AMX NXA-UPS1500 UNINTERRUPTIBLE POWER SUPPLY.


Access web reviews AMX NXA-UPS1500 UNINTERRUPTIBLE POWER SUPPLY, AMX CORPORATION, Router, Switch, Firewall & Other network security hardware.
Include the add-on to download manuals from your site, forum or blog Frequently Asked Questions Contact Diplodocs team Last searches
Last additions
Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.