AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX Corporation, with the following exceptions: · · · Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year. Disk drive mechanisms, pan/tilt heads, power supplies, and MX Series products are warranted for a period of one (1) year. AMX Lighting products are guaranteed to switch on and off any load that is properly connected to our lighting products, as long as the AMX Lighting products are under warranty. AMX Corporation does guarantee the control of dimmable loads that are properly connected to our lighting products. The dimming performance or quality cannot be guaranteed due to the random combinations of dimmers, lamps and ballasts or transformers. Unless otherwise specified, OEM and custom products are warranted for a period of one (1) year. AMX Software is warranted for a period of ninety (90) days. Batteries and incandescent lamps are not covered under the warranty.
· · ·
This warranty extends only to products purchased directly from AMX Corporation or an Authorized AMX Dealer. All products returned to AMX require a Return Material Authorization (RMA) number. The RMA number is obtained from the AMX RMA Department. The RMA number must be clearly marked on the outside of each box. The RMA is valid for a 30-day period. After the 30-day period the RMA will be cancelled. Any shipments received not consistent with the RMA, or after the RMA is cancelled, will be refused. AMX is not responsible for products returned without a valid RMA number. AMX Corporation is not liable for any damages caused by its products or for the failure of its products to perform. This includes any lost profits, lost savings, incidental damages, or consequential damages. AMX Corporation is not liable for any claim made by a third party or by an AMX Dealer for a third party. This limitation of liability applies whether damages are sought, or a claim is made, under this warranty or as a tort claim (including negligence and strict product liability), a contract claim, or any other claim. This limitation of liability cannot be waived or amended by any person. This limitation of liability will be effective even if AMX Corporation or an authorized representative of AMX Corporation has been advised of the possibility of any such damages. This limitation of liability, however, will not apply to claims for personal injury. Some states do not allow a limitation of how long an implied warranty last. Some states do not allow the limitation or exclusion of incidental or consequential damages for consumer products. In such states, the limitation or exclusion of the Limited Warranty may not apply. This Limited Warranty gives the owner specific legal rights. The owner may also have other rights that vary from state to state. The owner is advised to consult applicable state laws for full determination of rights. EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY, AMX CORPORATION MAKES NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. AMX CORPORATION EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY. ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF THIS LIMITED WARRANTY.
Table of Contents
Table of Contents
Introduction ...............................................................................................................1
Features ............................................................................................................................ 1 Applications ....................................................................................................................... 2 Controllers ......................................................................................................................... 2 AMX Lighting Control Equipment ...................................................................................... 3
Installation .................................................................................................................5
Space Requirements......................................................................................................... 5 Conduit .............................................................................................................................. 5 Enclosure Dimensions....................................................................................................... 6
RDA-ENC2, -ENC4, and -ENC6 enclosure and dimensions ................................................... 6 RDA-ENC6B and RDA-ENC12B enclosures and dimensions ................................................. 6
Mounting AMX Lighting Enclosures .................................................................................. 7 High-Voltage Connections................................................................................................. 7
Connecting high-voltage, single-phase input power and loads................................................ 8 RDA-ENC6B 120 VAC single phase line input ........................................................................ 8 RDA-ENC6B 120/240 VAC line input (single phase) ............................................................... 9 Connecting high-voltage, three-phase input power and loads ................................................. 9 RDA-ENC6B 120/208 VAC line input (three phase) .............................................................. 10 RDA-ENC6B three phase line input connector reference ...................................................... 10 RDA-ENC6 and RDA-ENC12 power distribution and line input references........................... 11 Installing RDM Modules into an Enclosure ............................................................................ 11
Low-Voltage Connections ............................................................................................... 12
Module connections ............................................................................................................... 13 Green status LED indicator .................................................................................................... 14 Red status LED indicators...................................................................................................... 14 Configuring and connecting PROlink ..................................................................................... 14 Configuring and connecting AXlink ........................................................................................ 16 Connecting dry closures......................................................................................................... 16
Default Mode (Reset) ...................................................................................................... 17 External power ................................................................................................................ 18
Compatible Ballast Information ............................................................................19
AC-Controlled Magnetic Ballasts..................................................................................... 19 AC-Controlled Electronic Ballasts (3-Wire Ballasts)........................................................ 19 DC-Controlled Electronic Ballasts (4-Wire Ballasts)........................................................ 19 Ballast Interfaces and 2-Wire Ballasts............................................................................. 20
Radia Lighting Control System
i
Table of Contents
Glossary .................................................................................................................. 21
ii
Radia Lighting Control System
Introduction
Introduction
The AMX Radia Lighting Control SystemTM employs a dual-platform programming architecture that supports both the Axcess programming language and PROlink. The AMX Lighting product line is modular by design, and includes a wide variety of integrated dimmer control modules, dimmer modules, and also switch/relay modules. There are also circuit cards that can control dimming and switching of incandescent, fluorescent, neon (cold-cathode), high and low-voltage equipment, loads (motors), electronic and magnetic ballasts. These cards and controllers can be housed in any of our five enclosures to ensure complete compliance with any spacing/application requirements. Once the lighting control requirements are defined, you can choose from the extensive group of lighting controllers, modules, etc., install them into the best-suited enclosures, and create the perfect lighting control system for your customers. FIG. 1 shows some of the AMX Lighting Control System components.
FIG. 1 AMX Lighting Control System components
Features
The AMX Lighting Control System features include: Controls up to 1,500 dimmers or 255 6-channel devices (approximate) with a AMX Axcess Control System complete with dimmer-level feedback Controls up to 60 dimmers with standalone PROlink systems Supports 128 lighting scene presets stored in 16K of non-volatile memory Recalls up to 8 of 128 presets with contact closures Modular and scalable lighting system configurations of one to 1,500 dimmers Supports both Axcess and PROlink programming languages Modules are UL and C-UL listed for United States and Canadian compliance
Radia Lighting Control System
1
Introduction
Applications
You can use the AMX Lighting Control System for commercial, corporate, and residential applications. The dual-platform Axcess and PROlink control architecture can address virtually any number of lighting zones. Entire residential or commercial lighting systems can be manually controlled or fully automated. AMX Lighting systems can also be integrated into existing Axcess presentation/control systems. Residential applications can be divided into inter-linked lighting zones using central and local control configurations. FIG. 2 shows a sample AMX Lighting system configuration using PROlink, dry closure, and AXlink devices.
RS-232 AMX Lighting Controllers
AXlink AXB-EM232
Pack 1
Pack 2
AXlink PROlink
PROlink PROlink
Touch panel
Wall panel
Wall panel
FIG. 2 Sample AMX Lighting Control System
Controllers
The four controllers available for AMX Lighting installations include the RDD-DM4 (4-channels), RDD-DM6 (6-channels) Integrated Dimmer Control Modules, and the RDC-DC (6-channel) and RDC-PDC Pro (6-channel) Dimmer Control Cards.
2
Radia Lighting Control System
Introduction
AMX Lighting Control Equipment
The following table lists all of the AMX Lighting Control System equipment. Refer to the installation sheets for these enclosures, control modules, and dimmer modules for detailed wiring drawings, application notes, and specifications. AMX Lighting Control Equipment
AMX Lighting enclosures RDA-ENC2 RDA-ENC4 RDA-ENC6 RDA-ENC6B 2-module enclosure for single-phase dimmer modules 4-module enclosure for dimmer modules 6-module enclosure for single-phase dimmer modules 6-module, 6-breaker (20 A each) enclosure for multi-phase wiring for one RDA-PDC module (two or three phase configuration)
RDA-ENC12B 6-module, 12-breaker (20 A each) enclosure that supports multi-phase wiring for two RDAPDC modules Control cards RDC-DC RDC-PDC 6-channel, single-phase control card (120, 240, or 277 VAC) 6-channel, dimmer control card (120 or 240 VAC)
Integrated dimmer control modules RDD-DM4 RDD-DM6 4-channel integrated dimmer control module (120 or 240 VAC) 6-channel integrated dimmer control module (120 or 240 VAC)
Dimmer modules RDA-CKM RDA-PSM RDM-2DC RDM-2FDB RDM-2HSW RDM-2INC RDM-2MR RDM-2PR RDM-2SWM RDM-22ZC RDM-3DC RDM-3FDB RDM-3HSW RDM-3MR RDM-3SWM RDM-DC RDM-2DC RDM-3DC RDM-DPSM RDM-HDC RDM-HFDB RDM-HSW RDM-INC RDM-INC50 Dual Choke module (350 µS) Power supply module Dual VDR module (2400 W x 2, 0-12 VDC) Dual FDB module (2400 W x 2) Dual heavy-duty switch module (2400 W x 2) Dual incandescent dimming module (2400 W x 2) Dual mercury relay module (10 A x 2) Dual peak relay module (2400 W x 2) Dual switch module (2400 W) Dual zero cross module (2400 W) Triple VDR module, 2400 W x3, 0-12 VDC Triple FDB module (2400 W x 3) Triple heavy-duty switch module (2400 W x 3) Triple mercury relay module (10 A x 3) Triple switch module (20 A x 3) DC dimmer module, 1920 W, 0-12 VDC Dual DC dimmer module, 1920 W, 0-12 VDC (x2) Triple DC dimmer module, 1920 W, 0-12 VDC (x3) Double-pole, single-throw module (2400 W) Heavy duty DC module, 2400 W, 0-12 VDC Heavy duty FDB module (20 A) Heavy-duty switch module (2400 W) Incandesc ...