9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your AVENT ISIS IQ UNO INSTRUCTIONS : user manual, user guide, instruction manual.
Search a brand
Advanced Search

User manual AVENT ISIS IQ UNO INSTRUCTIONS

Diplodocs help download the user guide AVENT ISIS IQ UNO INSTRUCTIONS .

Download the complete user guide (1053 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide AVENT ISIS IQ UNO INSTRUCTIONS

Detailed instructions for use are in the User's Guide.

We've taken everything women loved about our classic ISISTM manual breast pump ­ the soft petal massager and fingertip sensitive control that make it feel so gentle, natural and comfortable ­ and we've given it an iQ ­ an electronic memory. ISIS iQ learns from you. Begin by pumping manually, then touch the button and let ISIS iQ quietly continue your exact pumping rhythm. If at any time you want to vary the rhythm, touch the button again to revert to manual. ISIS iQ is totally responsive to your needs. Relax and enjoy the experience because you're always in complete control. And when you're relaxed and comfortable, you express more milk, faster. For our complete catalogue of mother and babycare products Please take a few minutes to read through the ENTIRE INSTRUCTION LEAFLET before you use your ISIS iQ UNO for the first time. PLEASE SAVE THESE INSTRUCTIONS. Unless advised otherwise by your health professional it is best to wait until your breastfeeding routine is established before expressing ­ usually after around four weeks. UK: Call FREE on 0800 289 064 UK ONLY (9am­4.30pm Mon-Fri) IRL: Call FREE on 1800 509 021 IRL ONLY (9am­4.30pm Mon-Fri) Contents ISIS iQ UNO parts Important safeguards How to clean and sterilise your ISIS iQ UNO How to assemble your ISIS iQ UNO How to use your ISIS iQ UNO Hints to help you succeed Using your ISIS iQ UNO as a manual breast pump Storing your expressed breast milk PAGE 2­3 4 5­ 6 7­ 8 9­ 12 14 15­ 16 17 18 19­ 20 AUS: 1300 364 474 (Australia National) AUS: (02) 9457 0127 (Australia NSW only) AVENT®, Suffolk, CO10 7QS, England Tel. 44 1787 267 000 Fax. 44 1787 267 001 Key to product label and Guarantee Troubleshooting guide www.avent.com 83 0081 0489 #1 (01/06) If you experience any problems or need any help with this product, please contact AVENT Customer Services (see back cover for contact details). Our representatives will be happy to assist you. 1 ISIS iQ UNOTM parts Pump parts a Main parts in detail Bottle parts Light Power socket Cracking or discolouration of pump parts h b c l Control handle · Avoid contact with antibacterial detergents/cleaners as they can damage the plastic. Combinations of detergents, cleaning products, sterilising solution, softened water and temperature fluctuations may, under certain circumstances, cause the plastic to crack. If this occurs, do not use. The pump body and breast milk containers are dishwasher safe but food colourings may discolour them. Follow guidelines in `How to clean and sterilise your ISIS iQ UNOTM' on pages 5-6. · Contact the AVENT Customer Services for replacements (see back cover for contact details). · Ensure the pump is correctly assembled and switched on with the power indicator illuminated `GREEN'. · Make sure the lead between the electrical wall socket or battery pack and the pump is correctly connected. g k Control button Lost or broken parts Pump not responding d Control handle NEVER STERILISE OR IMMERSE IN WATER! m i e n Power cable o j Pump light flashing RED · 3 flashes, delay, 3 flashes etc ­ if the pump stops working and the power light is flashing RED the pump has detected a vacuum fault. Disconnect the power and check the control handle and diaphragm for obstructions or damage. · Continuous RED pulsing flash ­ Low battery warning. You should consider replacing the batteries. f Difficulties separating the control handle from the pump body · The pump must be switched off via the control button in order to separate these parts. If the batteries go flat mid-pumping, you may experience difficulty. Replace the batteries or connect the pump to the mains. Turn the pump on by holding down the control button for 2 seconds ­ the light will turn GREEN. Now turn it off by holding the button for 2 seconds ­ the light will go off. You can now disconnect the pump from the power supply and should be able to separate the parts. a b c d e f g 1x Control handle 1x Silicone diaphragm with stem 1x White Valve 1x Pump body 2x Reusable bases (1x 125ml/4oz and 1x 260ml/9oz) 1x Stand (same as h ) 1x Let-down Massage CushionTM h i j k l m n o 1x Funnel cover (same as 1x Battery pack 1x Wall plug lead 1x Dome cap 1x Newborn Teat (0m+) 2x Screw rings 1x Travel cover 2x Sealing discs f ) Only the following batteries are compatible with the ISIS iQ UNOTM Battery Pack: Duracell Ultra M3, Duracell Plus, Energiser Ultra Plus, Duracell Accu (NiMH), Ansmann (NiMH). For Duracell Acc (NiMH) & Ansmann (NiMH) use / charge in accordance with manufacturers guidelines. Dispose of batteries as per manufacturers instructions. Battery pack NEVER STERILISE OR IMMERSE IN WATER! 2 3 20 Important safeguards READ ALL INSTRUCTIONS BEFORE USING YOUR ISIS iQ UNOTM BREAST PUMP When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following. WARNING ­ To reduce the risk of fire, electrocution or other personal injury: · · · · · · · · · · · · · · · · Always unplug from the electrical wall socket immediately after use. Do not use while bathing. Do not place or store the product where it can fall or be pulled into a bath or sink. Do not place or drop the control handle, battery pack or wall plug lead into water or other liquids. Do not reach for a product that has fallen into water. Unplug from the wall socket immediately. Close supervision is necessary when this product is used near children or persons with disabilities. Do not allow children or pets to play with the control handle, battery pack, wall plug lead or accessories as these parts may pose a choking or strangulation danger. Never operate this product if it has a damaged lead or plug, if it is not working properly, if it has been dropped or damaged, or has been submerged in water. Only use attachments recommended by AVENT. Do not use outdoors or where aerosol spray products are being used, or where oxygen is being administered. Equipment not suitable for use in the presence of flammable anaesthetic mixture with air, or with oxygen or nitrous oxide. Only use the wall plug lead and battery pack supplied with the product. There are no user serviceable parts inside the ISIS iQ UNO. Do not attempt to open, service or repair the ISIS iQ UNO yourself. Keep leads away from heated surfaces. This product is a personal care item and should not be shared between mothers. Do not attempt to remove pump body from the breast whilst under vacuum. Press the control button to revert to manual control then break the seal between the breast and the pump body with your finger. Do not operate unless control handle is connected to a pump body. Never use when sleepy or drowsy. · · CAUTION ­ To reduce the risks of injury, device malfunction or failure: The product should not be left unattended when plugged into an electrical wall socket. Never drop or insert any foreign object into any opening. Make sure the voltage of the wall plug lead is compatible with the power source. Plug the end of the wall plug lead into the control handle first, then securely attach the wall plug into the electrical socket. · Although compliant with applicable EMC directives, this equipment may still be susceptible to excessive emissions and/or may interfere with more sensitive material. · Wash, rinse and sterilise the appropriate pump parts before each use. · Do not continue pumping for more than five minutes at a time if no result is achieved. · · · · 4 How to clean and sterilise your NEVER WASH OR STERILISE... the control handle (a), battery pack (i) or wall plug lead ( j). These components DO NOT come into contact with your breast milk. You can wipe the control handle clean, using a soft cloth. i j a ISIS iQ UNOTM Sterilise in a steam steriliser (electronic, electric or microwave), or by boiling in water for 10 minutes. The AVENT Electronic, Electric and Microwave Steam Sterilisers are specially designed to hold the ISISTM breast pump parts and will remain sterile inside the steriliser for 3 hours, provided the lid is not removed. Cleaning the pump body and breast milk storage components Before you use your breast pump for the first time and every time before use, you must disassemble, wash and sterilise all the breast pump parts that come into contact with your breast milk. (See opposite). You can use the dishwasher (top rack only) or hand wash in warm, soapy water and then rinse thoroughly. Do not use antibacterial cleaners or detergents as they may cause the plastic to crack. b c k Keeping your pump sterile and compact for travel After sterilising all parts, insert the white valve (c) and diaphragm with stem (b) into the pump body (d) and clip the funnel cover (h) over the funnel and Let-down Massage CushionTM (g). Now screw the travel cover (n) onto the pump body (d) in place of the milk container. n l d g m d g b e h n o h 5 6 How to assemble your ISIS iQ d c e UNOTM a a g 1 With clean hands, click the white valve (c) into the pump body (d) from the bottom making sure that the pointed side of the valve faces downwards. 2 Twist the milk container (e) onto the pump body (d) until securely in place. 5 Carefully insert the Let-down Massage CushionTM (g) into the pump body (d), making sure it completely covers the edge of the funnel. (This is easier if the Let-down Massage Cushion is wet). 6 Firmly push the control handle (a) onto the pump body (d) so that it sits securely on top of the silicone diaphragm (b). j f b i 3 To ensure the pump doesn't topple, insert the milk container into the stand provided (f). 4 Place the silicone diaphragm with stem (b) into the pump body (d), making sure it fits securely around the edge, to create a seal. (This is easier if the diaphragm is wet). 7 For mains use connect the wall plug lead ( j) to the control handle (a) and plug into an electrical wall socket. 8 For battery use, open the top of the battery pack (i) and insert 4 x AA batteries*. Connect the power lead to the control handle (a). 7 *For batteries compatible with ISIS iQ UNO, see page 3. 8 How to use your ISIS iQ UNOTM Before you use your ISIS iQ UNO, make sure you have washed, sterilised and carefully assembled your pump exactly as described on pages 5-8. Wash your hands thoroughly and make sure your breasts are clean. Relax in a comfortable chair, leaning slightly forward (use cushions to support your back). Make sure you have a glass of water nearby as expressing can be thirsty work. A photograph of your baby will help too. Begin by gently squeezing the handle 5 or 6 times quite quickly, simulating the rapid suckling you usually feel when your baby is first put to the breast. Your milk will soon begin to flow and you can establish a slower, comfortable pumping pattern. Many mothers find that holding down the handle for 2 to 3 seconds at a time imitates the feeling of their baby breastfeeding. To begin pumping Switch on at the wall socket if using mains power. To turn the pump on, press and hold the control button for 2 seconds. The light on the top of the control handle will flash ORANGE and then turn to a solid GREEN to indicate that the pump is ready to use. If at any time the light is flashing red, stop and consult the `Troubleshooting guide' on pages 19-20. 3 When you have established a comfortable pumping rhythm with at least 2 squeezes, simply press the control button on the handle, and the ISIS iQ UNOTM will automatically continue in the same way. 1 Press the assembled pump firmly against your breast to create a seal. Using the control handle you can find your exact comfort level. As you press down on the handle you will feel greater suction against your breast. You don't need to squeeze the handle fully, only as far as feels comfortable for you. The light on the control handle will turn from solid GREEN to a flashing GREEN. Your pattern will now be stored in the pump's memory ­ even after the pump has been switched off! 4 2 9 10 To change your pumping rhythm If at any time you want to change your pumping rhythm, press the control button again and the pump will revert to manual fingertip control. The light will turn back to solid GREEN. You can now pump manually until you are comfortable again. Then press the control button again and ISIS iQ will continue your chosen rhythm. To collect your milk After you have expressed your milk, unscrew the pump body from the milk container (e). If you're using AVENT milk containers, insert a sealing disc (o) into the screw ring (m) and twist it onto the milk container. If you're using VIATM, unscrew the adaptor and screw a lid onto the cup. On average you will need to pump for 10 minutes to express 60-120mls/2-4ozs. However, this is just a guide and varies from woman to woman. If you find that you regularly express more than 120mls/4ozs per session, please use a 260ml/9oz AVENT milk container. To stop pumping If at any time the suctio ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.