Note
TABLE OF CONTENTS 1. Safety Instruction 2. Technical Specification 2.1 Inserting/Exchanging rotating gobos 3. Lamp 4. How To Set The Unit 4.1 Control Panel 4.2 Main Function
2A
5. How To Control The Unit 5.1 Master/Slave Built-In Preprogrammed Function. 5.2 Easy Controller 5.3 Universal DMX Controller 5.4 DMX512 Configuration 5.5 DMX512 Connection 6. Troubleshooting 7. Fixture Cleaning
1. Safety Instruction Please read carefully the instruction, which includes important information about the installation, usage and maintenance.
WARNING Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet. Unpack and check carefully there is no transportation damage before using the unit. Before operating, ensure that the voltage and frequency of power supply match the power requirements of the unit. The unit is designed for use with the MSD 250W. Do not use any other type of lamp. It's important to ground the yellow/green conductor to earth in order to avoid electric shock. The unit is for indoor use only. Use only in a dry location. The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces. Be sure that no ventilation slots are blocked. Disconnect main power before fuse/lamp replacement or servicing. Replace fuse/lamp only with the same type. Make sure there are no flammable materials close to the unit while operating, as it is fire hazard. Use safety chain when fixes this unit. Don't handle the unit by taking its head only, but always by taking its base. Maximum ambient temperature is Ta : 40. Don't operate it where the temperature is higher than this. Unit surface temperature may reach up to 85. Don't touch the housing bare-hand during its operation, and allow about 15 minutes to cool down before replacing bulb or serving, as the unit could be very hot. In the event of serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts. Don't connect the device to any dimmer pack. Do not touch any wire during operation as high voltage might be causing electric shock.
3A
7. Fixture Cleaning
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit's optics. Clean with soft cloth using normal glass cleaning fluid. Always dry the parts carefully. Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.
EC Declaration of Conformity We declare that our products (lighting equipments) comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility (EMC) Directive 89/336/EEC. EN55014-1: 1993, EN61000-3-2: 1995, EN61000-3-3: 1995 EN55014-2: 1997 CATEGORY II EN61000-4-2: 1995, EN61000-4-3: 1995, EN61000-4-4: 1995 EN61000-4-5: 1995, EN61000-4-6: 1995, EN61000-4-11: 1994 & Harmonized Standard EN60598-1: 1993 Safety of household and similar electrical appliances Part 1 : General requirements Following the provisions of the Low Voltage Directive 73/23/EEC and 93/68/EEC. EC Declaration of Conformity We declare that our products (remote controller) comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility (EMC) Directive 89/336/EEC. EN55015: 1993 EN50082-1: 1997 EN61000-3-2: 1995 EN61000-3-3: 1995
G. If The pan belt is broken 1. Turn off the main power. 2. Unscrew all the screws (A) and open the base-housing cover (B). 3. Unplug all the connect wires (C) that from the arm to PC board and igniter. 4. Unscrew the screws (D) that fix the bridge (E). 5. Unscrew the screws (F) that fix the axis gear (G). 6. Change a new belt (H) by going through all connecting wires that from the arm to base, and through the bridge for correct position. 7. Set up the gear axis to the bridge and screwed it. Note: do not press the belt. 8. Put the belt around the axis gear and motor gear. 9. Plug all the connect wires (C) that form the arm to PC board and igniter. 10. Adjust the pan home position. 11.Screw the base-housing cover (B).
Warning
To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture. Never touch bulb with bare fingers, as it is very hot after using. Hot lamp explosion hazard. Do not open the unit within five minutes after switching off. Do not start on the unit without bulb enclosure or housing are damaged. The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged. Do not look directly at the light while the bulb is on.
Caution
There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact your nearest dealer.
Installation
The unit should be mounted via its mounting system ( as shown below ) on the bottom of the
4A
base. Use clamps to fix the unit to truss. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 30 kgs for each unit.
2. Technical Specification
Power supply - AC 120V~60Hz or 230V/240V/250V 50/60Hz Lamp - Discharge lamp MSD 250W GY9.5 Optical system - Standard 13° focused beam angle. - Focus adjustable by DMX control Shutter/Dimmer - Blackout, 0~100 smooth dimming and strobe speed variable(1~10 flashes per second). Gobo wheel - Independent gobo wheel with 7 gobos plus open, gobos are interchangeable: 4 metal gobos, 2 glass gobos, and 1 effect gobo. 3 additional metal gobos and 2 effect gobos are included. - Gobo wheel rotates with variable speed. Shaking effect included. Color wheel - Independent color wheel with 9 dichroic mirrors plus white. - Color wheel rotates with variable speed, giving rainbow effect. Prism - 3-facet prism rotates in both directions at variable speeds Movement - Pan: 540° in 2.8 second. - Tilt: 270° in 1.6 second. DMX Channels - Standard DMX512 signal addressing and can be controlled by any universal DMX controller. Channel 1 = Pan motion Channel 2 = Tilt motion Channel 3 =Pan/Tilt Speed select Channel 4 = Dimmer Channel 5 = Shutter/ Shaking Channel 6 = Color Channel 7 = No Function Channel 8 = Reset Channel 9 = Gobo Channel 10 = Gobo Rotation Channel 11 = Prism Channel 12 = Prism Rotation Channel 13 = Focus Channel 14 = Pre-programmed Show Pattern Channel 15 = Pre-programmed Beam Pattern Channel 16 = Reset
5A
6. Troubleshooting
Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting: A. The unit does not work, no light and the fan does not work 1. Check the connect power and main fuse. 2. Measure the mains voltage on the main connector. 3. Check the power on LED. B. Not responding to DMX controller 1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly. 2. If the DMX LED is on and no response to the channel, check the address settings and DMX polarity. 3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the unit or the previous one. 4. Try to use another DMX controller. 5. Check in the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit. C. Some units don't respond to the easy controller 1. You may have a break in the DMX cabling. Check the LED for the response of the master/ slave mode signal. 2. Wrong DMX address in the unit. Set the proper address. D. No response to the sound 1. Check the unit that is not receiving DMX signal. 2. Check microphone to see if it is good by tapping the microphone E. One of the channels is not working well 1. The stepper motor might be damaged or the cable connected to the PCB is broken. 2. The motor's drive IC on the PCB might be out of condition. F. The lamp is cutting out intermittently 1. The lamp is not working well. Check the main voltage either too high or too low. Internal temperature may be too high. Check and if necessary replace the fan on the head.
Dimension: 360mm x 397mm x 503mm (L x W x H) Weight: 26 kg
5.5. DMX512 Connection
The DMX512 is widely used in intelligent lighting control, with a maximum of 512 channels.
Luminous intensity:
2.1. Inserting/Exchanging rotating gobos DANGER!
Install the gobos with the device switched off only. Unplug from mains before changing gobos!
6A
Open the cover by loosening the fastening screw at the sides of the cover. If you wish to use other forms and patterns as the standard-gobos, or if the gobos are to be exchanged, remove the fixation ring with an appropriate tool. Remove the gobo and insert the new gobo. Press the fixation-ring together and insert it in the front of the gobo.
1. If you use a controller with 5 pins DMX connector, you need to use a 5 to 3 pin adapter. 2. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last unit. 3. Connect the unit together in a "daisy chain" by XLR plug from the output of the unit to the input of the next unit. The cable cannot be branched or split to a "Y" cable. DMX512 is a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors can easily distort the signal and shut down the system. 4. The DMX output and input connectors are pass-through to maintain the DMX circuit, when power is disconnected to the unit. 5. Each lighting unit needs to have an address set to receive the data sent by the
controller. The address number is between 0-511 (usually 0 & 1 are equal to 1).
6. The end of the DMX512 system should be terminated to reduce signal errors. 7. 3 pin XLR connectors are more popular than 5 pins XLR.
CAUTION!
Never unscrew the screws of the rotating gobo as the ball bearing will otherwise be opened!
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+) 5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
3. Lamp
In case of replacement of the lamp or maintenance, do not open the fixture within 15 minutes until the unit cools down after switching off. Because of its high internal pressure, there might be a risk that the Discharge lamp would explode during operation. The lamp emits intense UV radiation which is harmful to the eyes and skin. The high luminance of the arc can cause severe damage to the retina if looks directly at the lamp. Discharge lamp: MSD 250W 1. Always switch off the main supply and never handle the lamp or luminaries when is hot. 2. Do not touch the bulb with bare hands. If this happens, clean the lamp with denatured alcohol and wipe it with a lint free cloth before installation. 3. The lamp generates UV radiation. Never operate the lamp without appropriate shielding. 4. When burning, the lamp operates at high pressure and there is a slight risk of arc tube rupture. The risk increases with age, temperature and improper handling of the lamp. Do not use the lamp any longer than its specified life. 5. Make sure the lamp is located in the center of the reflector for the best spot. Adjust lamp position by screws A, B and C.
7A
i.) Channel 14 ÂPre-programmed show pattern: 1.) DMX value 0-31,the fixture is still controlled by DMX control . 2.) For DMX Value above 31,all the DMX control will be invalid .The fixture will run the pre-programmed show patterns(Pan/Tilt movement). ii.) Channel 15-Pre-programmed beam pattern: One can select the beam pattern only when the pre-programmed show pattern is activated. iii.) For DMX Reset, put DMX value of CH-8 & CH-16 to 255.
5.4. DMX512 Configuration
4. How To Set The Unit 4.1. Control Panel
Display To show the various menus and the selected functions.
8A
LED DMX MASTER SLAVE SOUND Button MENU DOWN UP ENTER Remote controller input By connect to the 1/4" microphone jack to control the unit for Stand by, Strobe/Next and Show 1/Slow/Show 2 function. Sensitivity To adjust the sound-receiving sensitivity. Microphone To receive audio signal for sound activation. DMX input/output To select the programming functions To go backward in the selected functions To go forward in the selected functions To confirm the selected functions On On On Flashing DMX input present Master mode Slave mode Sound activation