Need help using a product?
|
|
|
|
User manual BEGLEC IM-5W
Diplodocs help download the user guide BEGLEC IM-5W .
This product, although classified under the brand BEGLEC, may have been manufactured by ANTARI, BRITEQ, GENI ELECTRONICS, ISOLUTION, JBSYSTEMS, JBSYSTEMS LIGHT, LIGHT PUTER, SYNQ after mergers, acquisitions, or a change in name.
Preview of the first 3 pages of manual
You either have JavaScript turned off or an old version of Adobe Flash Player Get the latest Flash Player.
Manual abstract: user guide BEGLEC IM-5W
Detailed instructions for use are in the User's Guide. Technical Specifications
Power Fuse Lamp Dimension Weight AC 120V~60Hz AC 230/240/250V~50/60Hz
20mm Glass T6.3A Fast Blow 20mm Glass T5A Fast Blow ELC 24V 250W 290mm x 330mm x 380mm 12 kg
IM-5S
IM-5W
Innovation , Quality , Performance
User Guide
WWW.BEGLEC.COM
7. Fixture Cleaning
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit's optics. Clean with soft cloth using normal glass cleaning fluid. Always dry the parts carefully. Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.
EC Declaration of Conformity We declare that our products (lighting equipments) comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility (EMC) Directive 89/336/EEC.
2E
EN55014-2: 1997 A1:2001, EN61000-4-2: 1995; EN61000-4-3:2002; EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6:1996, EN61000-4-11: 1994. & Harmonized Standard EN60598-1: 2000+ALL:2000+A12:2002 Safety of household and similar electrical appliances Part 1 : General requirements
.
G. If The pan belt is broken 1. Turn off the main power. 2. Unscrew all the screws (A) and open the base-housing cover (B). 3. Unplug all the connect wires (C) that from the arm to PC board and ignitor. 4. Unscrew the screws (D) that fix the axis gear (E). 5. Change a new belt (F) by going through all connect wires that from the arm to base, and through the bridge for correct position. 6. Set up the gear axis to the bridge and screwed it. Note : do not press the belt. 7. Put the belt around the axis gear and motor gear. 8. Plug all the connect wires (C) that form the arm to PC board and ignitor. 9. Adjust the pan home position. 10. Screw the base-housing cover (B).
.
TABLE OF CONTENTS 1. Safety Instruction 2. Technical Specification 2.1 Beam Angel 3. Lamp 4. How To Set The Unit 4.1 Control Panel 4.2 Main Function 5. How To Control The Unit 5.1 Master/Slave Built-In Preprogrammed Function. 5.2 Easy Controller 5.3 iSolution Operation / Universal DMX Controller 5.4 DMX512 Configuration 5.5 DMX512 Connection 6. Troubleshooting 7. Fixture Cleaning
3E
1. Safety Instruction
Please read carefully the instruction, which includes important information about the installation, usage and maintenance.
6. Troubleshooting
Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting: A. The unit does not work, no light and the fan does not work 1. Check the connection of power and main fuse. 2. Measure the mains voltage on the main connector. 3. Check the power on LED. B. Not responding to DMX controller 1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly. 2. If the DMX LED is on and no response to the channel, check the address settings and DMX polarity. 3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the unit or the previous one. 4. Try to use another DMX controller. 5. Check if the DMX cables run near or run alongside to high voltage cables that may
4E
WARNING Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet. Unpack and check carefully there is no transportation damage before using the unit. Before operating, ensure that the voltage and frequency of power supply match the power requirements of the unit. The unit is designed for use with the ELC 24V 250W. Do not use any other type of lamp. It's important to ground the yellow/green conductor to earth in order to avoid electric shock. The unit is for indoor use only. Use only in a dry location. The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces. Be sure that no ventilation slots are blocked. Disconnect main power before fuse/lamp replacement or servicing. Replace fuse/lamp only with the same type. Make sure there is no flammable materials close to the unit while operating as it is fire hazard. Use safety cable when fixes this unit. Don't handle the unit by taking its head only, but always by taking its base. Maximum ambient temperature is TA: 40. Don't operate it where the temperature is higher than this. Unit surface temperature may reach up to 85. Don't touch the housing bare-hand during its operation. Turn off the power and allow about 15 minutes for the unit to cool down before replacing bulb or serving. In the event of serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts. Don't connect the device to any dimmer pack or power pack. Do not touch any wire during operation as high voltage might be causing electric shock.
cause damage or interference to DMX interface circuit. C. Some units don't respond to the easy controller 1. You may have a break in the DMX cabling. Check the LED for the response of the master/ slave mode signal. 2. Wrong DMX address in the unit. Set the proper address. D. No response to the sound 1. Make sure the unit does not receive DMX signal. 2. Check microphone to see if it is good by tapping the microphone E. One of the channels is not working well 1. The stepper motor might be damaged or the cable connected to the PCB is broken. 2. The motor's drive IC on the PCB might be out of condition. F. The lamp is cutting out intermittently 1. The lamp is not working well. Check the main voltage either too high or too low. 2. Internal temperature may be too high. Check and if necessary replace the fan on the head.
5.5 DMX512 Connection
The DMX512 is widely used in intelligent lighting control, with a maximum of 512 channels.
1 2 3 4
.
Warning To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture. Never touch bulb with bare fingers as it is very hot after using. Hot lamp explosion hazard. Do not open the unit within five minutes after switching off. Do not start on the unit without bulb enclosure or housing are damaged. The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged. Do not look directly at the light while the bulb is on.
DMX512 1
COMMON
3 2
120 ohm 1/4W 1 3 2
INPUT
DMX + DMX -
OUTPUT
Caution There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact your nearest dealer. Installation The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 20 kgs for each unit.
Termination reduces signal errors and to avoid signal transmission problems and interference. It is always advisable to connect a DMX terminal. (Resistance 120 ohm 1/4W) between pin2 (DMX-) and pin3 (DMX+) of the last fixture.
1 3 2
1. If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin adapter-cable. 2. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last unit. 3. Connect the unit together in a `daisy chain` by XLR plug from the output of the unit to the input of the next unit. The cable can not branched or split to a `Y` cable. DMX512 is a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors can easily distort the signal and shut down the system. 4. The DMX output and input connectors are pass-through to maintain the DMX circuit, when power is disconnected to the unit. 5. Each lighting unit needs to have an address set to receive the data sent by the controller. The address number is between 0-511 (usually 0 & 1 are equal to 1). 6. The end of the DMX512 system should be terminated to reduce signal errors. 7. 3 pin XLR connectors are more popular than 5 pin XLR. 3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+) 5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5E
2. Technical Specification
· VoltageAC 120V~60Hz or 230V/240V/250V~50/60Hz · BulbELC 24V 250W · The unit is DMX512 fixture. It features full DMX512 control. It can be also linked together in master/slave connection, as many as required and run by built-in program chase sequences automatically or by sound activation through an internal microphone to create an intelligent effect. · It can be operated by DMX512 control or can be used as an individual unit without a controller. · Consistent DMX channel enable iRock, iShow and iMove to be link together. · Features different preprogrammed chase patterns. · Please use a 3 pin XLR cable/plug when connecting units together. · Accurate focusable optics system and ultra smooth stepping motors. Fan cooling. · Pan : 540 deg. Tilt : 270 deg. · Dimension : 290 x 330 x 380 mm · Weight : 12 kg IM-5S Independent gobo wheel with 14 gobos plus open and blackout, including 10 metal, 1 replaceable gobo, 2 glass and 1 effect gobos with shaking and shutter effect, Independent color wheel with 11 dichroic colors with rainbow effect. IM-5W Independent color wheel with 11 dichroic colors with rainbow effect and independent shutter & dimmer.
6E
5.4 DMX512 Configuration
2.1 Beam Angel
Ch 1 IM-5S IM-5W Pan Pan
Ch 2 Tilt Tilt
Ch 3 Shutter/Sharking Shutter
Ch 4 Gobo No function
Ch 5 Color Color
Ch 6 No function
Ch 7 Dimmer
Stand by
Blackout the unit Strobe 1.Gobo / Color sync. strobe 2.Sync. strobe 3.Two-light strobe Sound 1 (LED off ) Blackout the unit Strobe 1.Color sync. strobe 2.Sync. strobe 3.Two-light strobe X/Y moving show mode Color selection selection ( Show 1 ~ Show 4 ) Please refer to Show mode in 4.2 Main Function X/Y moving setting 1.Pan position 2.Tilt position 3.Dimmer First set Master unit, then set Slave units' position Position/ Latch (LED fast blinking) X/Y moving show mode Color/Gobo selection 1. Hold on for gobo selection change. ( Show 1 ~ Show 4 ) Please refer to Show mode 2. Press shortly for color change in 4.2 Main Function Sound 2 (LED normal blinking) Slow/Sound 3 (LED on) X/Y moving setting 1.Pan position 2.Tilt position First set Master unit, then set Slave units' position Position/ Latch (LED fast blinking)
3. Lamp
In case of replacement of the lamp or maintenance, do not open the fixture within 15 minutes until the unit cools down after switching off.
IM-5S
Function
Mode Stand by
Â¥ Lamp : ELC 24V 250W 1. Always switch off the main supply and never handle the lamp or luminaries when is hot. 2. Do not touch the bulb with bare hands. If this happens, clean the lamp with denatured alcohol and wipe it with a lint free cloth before installation. 3. Never operate the lamp without appropriate shielding. 4. Make sure the lamp is located in the center for the best spot.
IM-5W
Function
Mode
Sound 1 (LED off )
Sound 2 (LED normal blinking)
Slow/Sound 3 (LED on)
5.3.1 iSolution Operation
Consistent DMX configuration enable iMove to be linked together with iRock and iShow and controlled at the same time. DMX address can be set remotely by iLead controller ( please refer to the user manual of iLead controller ). No need to calculate the DMX channels of each fixture in the chain. Automatic switching between DMX function and built-in stand alone programs.
7E
Diagram for Lamp changing
5.3.2 DMX Controller
An universal DMX controller to control the units, you have to set DMX address from 1 to 512 channel so that the units can receive DMX signal. Press the MENU button up to when the is showing on the display. Pressing ENTER button and the display will blink. Use DOWN and UP button to change the DMX512 address. Once the address has been selected, press and keep ENTER button pressed up to when the display stops blinking or storing automatically 8 seconds later. To go back to the functions without any change press the MENU button again. If you use please refer to the following diagram to address your DMX512 channel for the first 4 units. DMX address can be setting remotely by IL-0824 controller. No need to calculate the DMX channels of each fixture in the chain.
4. How To Set The Unit 4.1 Control Panel
5. How To Control The Unit
You can operate the unit in three ways: 1. By master/slave built-in preprogram function 2. By easy controller 3. By iLead controller ( please refer to the user guide o ...
|