Download user guide, user manual, owner manual and instructions guide
5 600 brands
1 870 000 user's guides
Search a brand
Advanced Search



Our partners wish to propose you the following products


Visit BEGLEC official site

User manual BEGLEC IMOVE 250W MOVING WASH

Diplodocs help download the user guide BEGLEC IMOVE 250W MOVING WASH.



Download the user manual BEGLEC IMOVE 250W MOVING WASH  
Download the complete
user guide (3391 Ko)
Need help, support, reviews, tips or troubleshooting for your BEGLEC IMOVE 250W MOVING WASH products ?

This product, although classified under the brand BEGLEC, may have been manufactured by ANTARI, BRITEQ, GENI ELECTRONICS, ISOLUTION, JBSYSTEMS, JBSYSTEMS LIGHT, LIGHT PUTER, SYNQ after mergers, acquisitions, or a change in name.

Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
User guide BEGLEC IMOVE 250W MOVING WASH

Detailed instructions for use are in the User's Guide.

TABLE OF CONTENTS iMove 250W Moving Wash 1.Safety Instruction 2.Technical Specification 3.Lamp 4.How To Set The Unit 4.1 Control Panel 4.2 Main Function 4.3 Home Position Adjustment 5.How To Control The Unit 5.1 Master/Slave Built-In Preprogrammed Function. 5.2 Easy Controller 5.3 iSolution Operation / DMX Controller 5.4 DMX512 Configuration 5.5 DMX512 Connection 6.Troubleshooting 7.Fixture Cleaning User Guide BEGLEC cva ­ `t Hofveld2 ­ 1702 Groot Bijgaarden Belgium WWW.BEGLEC.COM 1- 1. Safety Instruction Please read carefully the instruction, which includes important information about the installation, usage and maintenance. WARNING Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet. Unpack and check carefully there is no transportation damage before using the unit. Before operating, ensure that the voltage and frequency of power supply match the power requirements of the unit. The unit is designed for use with the MSD 250/2 or NSD250/2. Do not use any other type of lamp. It's important to ground the yellow/green conductor to earth in order to avoid electric shock. The unit is for indoor use only. Use only in a dry location. The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces. Be sure that no ventilation slots are blocked. Disconnect main power before fuse/lamp replacement or servicing. Replace fuse/lamp only with the same type. Make sure there are no flammable materials close to the unit while operating, as it is fire hazard. Use safety chain when fixes this unit. Don't handle the unit by taking its head only, but always by taking its base. Maximum ambient temperature is Ta : 40. Don't operate it where the temperature is higher than this. Unit surface temperature may reach up to 85. Don't touch the housing bare-hand during its operation, and allow about 15 minutes to cool down before replacing bulb or serving, as the unit could be very hot. In the event of serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts. Warning To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture. Never touch bulb with bare fingers, as it is very hot after using. Hot lamp explosion hazard. Do not open the unit within five minutes after switching off. Do not start on the unit without bulb enclosure or housing are damaged. The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged. Do not look directly at the light while the bulb is on. Caution There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact your nearest dealer. Installation The unit should be mounted via its mounting system ( as shown below ) on the bottom of the base. Use clamps to fix the unit to truss. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 30 kgs for each unit. Don't connect the device to any dimmer pack. Do not touch any wire during operation as high voltage might be causing electric shock. 23- 2. Technical Specification Power supply - AC 120V ~ 60Hz / 230V ~ 50Hz Lamp - Discharge lamp MSD 250/2 GY 9.5 Optical system - High efficiency optical system - High quality optical lens and dichroic colors - Manually adjustable beam angle: 16 ~26 Shutter/Dimmer - Blackout, 0~100 smooth dimming and strobe speed variable(1~10 flashes per second). Color wheel - Independent color wheel with 6 dichroic colors plus white. - Color wheel rotates with variable speed, giving rainbow effect. CMY Mixing system - Cyan: 0 ~ 100%, Magenta: 0 ~ 100%, Yellow: 0 ~ 100% Effect Wheel - Frost filter and beam shape effect Movement - Pan: 540° in 2.8 second. - Tilt: 270° in 1.6 second. DMX Channels - Standard DMX512 signal addressing and can be controlled by any universal DMX controller. 16 Channels: Channel 1 = Pan Channel 2 = Tilt Channel 3 = Pan/Tilt Speed Channel 4 = Dimmer Channel 5 = Shutter Channel 6 = Color Channel 7 = Cyan Channel 8 = Magenta Channel 9 = Yellow Channel 10 = CMY color Mix Channel 11 = CMY Speed Channel 12 = Effect Wheel Channel 13 = Dimmer Channel 14 = Pan 16 bit Channel 15 = Tilt 16 bit Channel 16 = Lamp On/Off/Reset 8 Channels: Channel 1 = Pan Channel 2 = Tilt Channel 3 = Shutter Channel 4 = Effect wheel Channel 5 = Color Channel 6 = CYM Color Mix Channel 7 = Dimmer Channel 8 = CMY Speed Dimension: 428 x 369 x 481 mm (L x W x H) Weight: 24.2 kg Luminous intensity: 4- 5- 3. Lamp In case of replacement of the lamp or maintenance, do not open the fixture within 15 minutes until the unit cools down after switching off. Because of its high internal pressure, there might be a risk that the Discharge lamp would explode during operation. The lamp emits intense UV radiation which is harmful to the eyes and skin. The high luminance of the arc can cause severe damage to the retina if looks directly at the lamp. Discharge lamp: MSD 250/2 GY 9.5 4. How To Set The Unit 1. Always switch off the main supply and never handle the lamp or luminaries when is hot. 2. Do not touch the bulb with bare hands. If this happens, clean the lamp with denatured alcohol and wipe it with a lint free cloth before installation. 3. The lamp generates UV radiation. Never operate the lamp without appropriate shielding. 4. When burning, the lamp operates at high pressure and there is a slight risk of arc tube rupture. The risk increases with age, temperature and improper handling of the lamp. Do not use the lamp any longer than its specified life. 5. Make sure the lamp is located in the center of the reflector for the best spot. Adjust lamp position by screws A, B and C. 4.1. Control Panel Display To show the various menus and the selected functions . LED DMX MASTER SLAVE SOUND Button 67On On On Flashing DMX input present Master mode Slave mode Sound activation MENU DOWN UP ENTER Remote controller input To select the programming functions To go backward in the selected functions To go forward in the selected functions To confirm the selected functions 4.2. Main Function To select any of the pre-set functions, press the MENU button up to when the required one is shown on the display. Select the function by ENTER button and the display will blink. Use DOWN and UP button to change the mode. Once the required mode has been selected, press the ENTER button to setup or it will automatically return to the main functions without any change after idling 8 seconds. To go back to the functions without any change press the MENU button. The main functions are shown below: DMX512 Address Setting Setting 16 Channel Setting 8 Channel Show mode 1 Show mode 2 Show mode 3 Show mode 4 Slave Mode " Normal " Slave mode " 2 Light Show " Blackout Mode " Yes Blackout " Blackout Mode " No Blackout " Pan Normal Pan Inversion Tilt Normal Tilt Inversion LED on LED off Display Normal Display Inversion Self-Test Ambient temperature of lamp Fixture Hours Lamp on Lamp off Reset By connecting to the 1/4" microphone jack to control the unit for Stand by, Function, and Mode function. Sensitivity To adjust the sound-receiving sensitivity . Microphone To receive audio signal for sound activation . DMX input/output For DMX512 link, use 3-pin XLR plug cable to link the unit together. MENU DMX512 Address Setting Press the MENU button up to when the is shown on the display. Pressing ENTER button and the display will blink. Use DOWN and UP button to change the DMX512 address. Once the address has been selected, press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds. To go back to the functions 8without any change press the MENU button again. 9- Channel Mode Press the MENU button up to when the Channel ) or is shown on the display. Pressing ENTER (16 Blackout Mode Press the MENU button up to when the blackout) or is shown on the display. Pressing ENTER (yes button and the display will blink. Use DOWN and UP button to select the button and the display will blink. Use DOWN and UP button to select the (8 Channel) mode. Once the mode has been selected, press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds. To go back to the functions without any change press the MENU button again. Show Mode Press the MENU button up to when the or (show 2) or (show 3) or is showing on the display. Pressing ENTER (show 1) (show 4) mode. Once the mode has (no blackout) mode. Once the mode has been selected, press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds. To go back to the functions without any change press the MENU button again. Pan Inversion Press the MENU button up to when the or is shown on the display. Pressing ENTER (normal) button and the display will blink. Use DOWN and UP button to select the button and the display will blink. Use DOWN and UP button to select the been selected, press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds. To go back to the functions without any change press the MENU button again. (pan inversion) mode. Once the mode has been selected, press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds. To go back to the functions without any change press the MENU button again. Tilt Inversion Show 1 mode - Fixture is placed on the floor. Tilt movement angle 210°. Show 2 mode - Fixture is fixed under ceiling. Tilt movement angle 90°. Show 3 mode - Fixture is placed on the speaker, The spot is always projecting to the audience's direction; i.e in front of the stage. Pan movement angle ( left to right to left ): 160°. below horizon.) Show 4 mode - Fixture is fixed under ceiling. The spot is mainly projecting in front of the stage. Pan movement angle ( left to right to left ) :160°. Tilt movement angle: 90° ( vertically, front 75°; back 15° ) Slave Mode Press the MENU button up to when the is shown on the display. Pressing ENTER (normal) Tilt movement angle: 90° ( 60° above horizon; 30° Press the MENU button up to when the or is shown on the display. Pressing ENTER (normal) button and the display will blink. Use DOWN and UP button to select the (tilt inversion) mode. Once the mode has been selected, press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds. To go back to the functions without any change press the MENU button again. Led Display Press the MENU button up to when the (Led on) or is showing on the display. Pressing ENTER button and the display will blink. Use DOWN and UP button to select the (Led off) mode. Once the mode has been selected, press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds. To go back to the functions without any change press the MENU button again. Display Inversion It is good for you to install the unit on the floor or under ceiling. Press the MENU button up to when the is blinking on the display. Use the ENTER button to change to the mode 11- button and the display will blink. Use DOWN and UP button to select the (2 light show) mode. Once the mode has been selected, press the ENTER or button to setup or automatically return to the main functions without any change after 8 seconds. To go back to the functions without any change press the MENU button again. 10- (display inversion), It will automatically store after 8 seconds. Or press the ENTER button again return to the mode the MENU button. Display normal mode for the fixture putting on the floor. Display inversion mode for the fixture fixing under ceiling. (display normal). To go back to the functions press Set DMX value of channel 8 and channel 16 to 255, then all channels of the unit will return to their standard home position. 4.3 Home Postion Adjustment Press MENU button for at least 5 seconds into offset mode to adjust the home position, the functions are shown below: Self-Test Press the MENU button up to when the MENU button again. Ambient temperature of lamp Press the MENU button up to when the functions press the MENU button again. Fixture Hours Press the MENU button up to when the functions press the MENU button again. Lamp Display Press the MENU button up to when the or is blinking on the display. Pressing ENTER (Lamp on) is blinking on the display. Pressing ENTER is blinking on the display. Pressing ENTER Pan offset Press the MENU button for at least 5 seconds into offset mode, use DOWN and UP button up to when the is shown on the display. Pressing ENTER button and the display will blink. Use DOWN and UP button to adjust the pan home position. Once the position has been selected, press the ENTER button to setup or automatically return to the offset functions without any change press the MENU button again, To go back to the main functions without any change after 8 seconds. Tilt offset Press the MENU button for at least 5 seconds into offset mode, use DOWN and UP button up to when the is shown on the display. Pressing ENTER button and the display will blink. Use DOWN and UP button to adjust the tilt home position. Once the position has been selected, press the ENTER button to setup or automatically return to the offset functions without any change press the MENU button again, To go back to the main functions without any change after 8 seconds. is blinking on the display. Pressing ENTER Pan offset(0~512) MENU Tilt offset(0~2048) button and the unit will run self-test by built-in program. To go back to the functions press the button and the ambient temperature of lamp will show on the display. To go back to the button and the display will show the number of working hours of the unit. To go back to the button and the display will blink. Use DOWN and UP button to select the (Lamp off) mode. Once the mode has been selected, press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds. To go back to the functions without any change press the MENU button again. Reset Press the MENU button up to when the functions press the MENU button again. DMX RESET : 12is blinking on the display. Pressing ENTER 5. How To Control The Unit You can operate the unit in three ways: 1. By master/slave built-in preprogram function 2. By easy controller 3. By IL-0824 ( please refer to the user guide of iLead controller ) or universal DMX 13- button and all channels of the unit will return to their standard position. To go back to the controller No need to turn the unit off when you change the DMX address, as new DMX address setting will be effected at once. Every time you turn the unit on, it will show 2500 on the display and move all the motors to their `home' position and you may hear some noises for about 20 seconds. After that the unit will be ready to receive DMX signal or run the built-in programs. 5.2. Easy Controller The easy remote control is used only in master/slave mode. By connecting to the 1/4" microphone jack of the first unit, you will find that the remote control on the first unit will control all the other units for Stand by, Function and Mode. Stand by Blackout the unit Strobe 1. Color sync. strobe 2. Sync. strobe 3. Two-light strobe X/Y moving show pattern Color selection selection ( Show 1 ~ Show 4 ) Please refer to 4.2. Main Functions- Show mode X/Y moving setting 1.Pan position 2.Tilt position 3.Dimmer First set Master unit, then set Slave units' position Position/ Latch (LED fast blinking) 5.1. Master/Slave Built-In Preprogrammed Function in (yes blackout) or (no blackout) You can select blackout mode mode while the unit is turned on. By linking the units in master/slave connection, the first unit will control the other units to give an automatic, sound activated, synchronized light show. This function is good when you want an instant show. You have to select show (show 1, 2, 3, 4) modes by easy controller . Its DMX input jack will have nothing plugged into it, and Its master LED will be constantly on and sound LED will flash to the music. The other units will have to set in slave mode and select (normal) or (2 light show) mode, Their DMX cables plugged into the DMX input jacks (daisy chain) and the slave LED lights will constantly on. 2-light show In (slave mode), means the unit works normally and means Function Mode Sound 1 (LED off ) Sound 2 (LED normal blinking) Slow/Sound 3 (LED on) 5.3.1 iSolution Operation · Consistent DMX configuration enable iRock and iShow to be linked together and controlled at the same time. ·DMX address can be set remotely by iLead controller ( please refer to the user manual of iLead controller ). No need to calculate the DMX channels of each fixture in the chain. ·Automatic switching between DMX function and built-in stand alone programs. 2-light show. In order to create a great light show, you can set on the second unit to get contrast movement to each other, even if you have two units only. 5.3.2 DMX Controller If you use a universal DMX controller to control the units, you have to set DMX address from 1 to 512 channel so that the units can receive DMX signal. Press the MENU button up to when the is shown on the display. Pressing ENTER button and the display will blink. Use DOWN and UP button to change the DMX512 address. Once the address has been selected, press and keep ENTER button pressed up to when the display stops blinking or storing automatically 8 seconds later. To go back to the functions without any change press the MENU button again. Please refer to the following diagram to address your DMX512 channel for the first 4 units. 16 Channels 14- 15- 5.4. DMX512 Configuration 8 Channels You have to set the fixture DMX address in 8 channels mode when you use IL-0824 controller. DMX address can be set remotely by IL-0824 controller. No need to calculate the DMX channels of each fixture in the chain. Please refer to the following diagram to address your DMX512 channel for the first 4 units. 8 Channels 16- 17- 5.5. DMX512 Connection The DMX512 is widely used in intelligent lighting control, with a maximum of 512 channels. iii.) For DMX Reset, put DMX value of CH-8 & CH-16 to 255. 1. 2. If you use a controller with 5 pins DMX connector, you need to use a 5 to 3 pin adapter. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last unit. 3. Connect the unit together in a "daisy chain" by XLR plug from the output of the unit to the input of the next unit. The cable cannot be branched or split to a "Y" cable. DMX512 is a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors can easily distort the signal and shut down the system. 4. 5. 6. 7. The DMX output and input connectors are pass-through to maintain the DMX circuit, when power is disconnected to the unit. Each lighting unit needs to have an address set to receive the data sent by the controller. The address number is between 0-511 (usually 0 & 1 are equal to 1). The end of the DMX512 system should be terminated to reduce signal errors. 3 pin XLR connectors are more popular than 5 pins XLR. 3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+) 18- 19- 5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+) 1. The lamp is not working well. Check the main voltage either too high or too low. 2. Internal temperature may be too high. Check and if necessary replace the fan on the head. G. If The pan belt is broken 1. Turn off the main power. 2. Unscrew all the screws (A) and open the base-housing cover (B). 3. Unscrew all the screws (C) and open the arm cover (D). 4. Unplug all the connect wires that from the arm to the bottom. 5. Unscrew the screws (E) and remove the fixture head. 6. Loose the screws (F), then loose the screws (G). 7. Change a new belt (H) , put the belt around the axis gear and motor gear. 8. Screwed the screws (G), install the new belt and adjust the belt tension properly. Note: do not fix belt too tight as it is easy to rupture. 9. Plug all the connect wires back that from the bottom to the arm. 10. Reverse the procedures from point 5 to point 2. 6. Troubleshooting Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting: A. The unit does not work, no light and the fan does not work 1. Check the connect power and main fuse. 2. Measure the mains voltage on the main connector. 3. Check the power on LED. B. Not responding to DMX controller 1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly. 2. If the DMX LED is on and no response to the channel, check the address settings and DMX polarity. 3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the unit or the previous one. 4. Try to use another DMX controller. 5. Check in the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit. C. Some units don't respond to the easy controller 1. You may have a break in the DMX cabling. Check the LED for the response of the master/ slave mode signal. 2. Wrong DMX address in the unit. Set the proper address. D. No response to the sound 1. Check the unit that is not receiving DMX signal. C D C D A F E A B B H 2. Check microphone to see if it is good by tapping the microphone E. One of the channels is not working well 1. The stepper motor might be damaged or the cable connected to the PCB is broken. 2. The motor's drive IC on the PCB might be out of condition. F. The lamp is cutting out intermittently 2021G A Pay attention to the belt tension when install the belt. Please refer to the photos below: 7. Fixture Cleaning The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit's optics. Clean with soft cloth using normal glass cleaning fluid. Always dry the parts carefully. Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days. F EC Declaration of Conformity G Photo 1 We declare that our products (lighting equipments) comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility (EMC) Directive 89/336/EEC. EN55014-2: 1997 A1:2001, EN61000-4-2: 1995; EN61000-4-3:2002; EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6:1996, EN61000-4-11: 1994. & Harmonized Standard EN60598-1: 2000+ALL:2000+A12:2002 Safety of household and similar electrical appliances Part 1 : General requirements Adjust belt tension through loose the screw Photo 2 22- 23-

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BEGLEC IMOVE 250W MOVING WASH.

BEGLEC offer a product for which we do not have the user manual? Let us know what you are looking for: site Internet, histoire, actualité, filiales, site Internet, mode d'emploi, driver, avis des utilisateurs, meilleur prix des produits, forum d'assistance aux problèmes, annuaire des marques, annuaire des constructeurs, répertoire des marques, répertoire des constructeurs, site Internet de la marque, site Internet du constructeur

Diplodocs allows you to download user manual BEGLEC IMOVE 250W MOVING WASH, user guide BEGLEC IMOVE 250W MOVING WASH, instructions BEGLEC IMOVE 250W MOVING WASH, owner's manual BEGLEC IMOVE 250W MOVING WASH, online manual BEGLEC IMOVE 250W MOVING WASH.


Access web reviews BEGLEC IMOVE 250W MOVING WASH, , DVD Player, DVD Recorder, Home Theater, Amplifier & Hi-Fi Audio.
Include the add-on to download manuals from your site, forum or blog Frequently Asked Questions Contact Diplodocs team Last searches
Last additions
Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.