User manual BEGLEC IR-5C
Diplodocs help download the user guide BEGLEC IR-5C .
This product, although classified under the brand BEGLEC, may have been manufactured by ANTARI, BRITEQ, GENI ELECTRONICS, ISOLUTION, JBSYSTEMS, JBSYSTEMS LIGHT, LIGHT PUTER, SYNQ after mergers, acquisitions, or a change in name.
Preview of the first 3 pages of manual
You either have JavaScript turned off or an old version of Adobe Flash Player Get the latest Flash Player.
Manual abstract: user guide BEGLEC IR-5C
Detailed instructions for use are in the User's Guide. Technical Specifications
IR-7S/IR-7B/IR-5C Power Fuse Lamp Dimension Weight AC 120V~60Hz or AC 230/240/250V~50/60Hz 20mm Glass 10A Fast Blow MSD 250/2 695 x 340 x 250 mm (IR-7S/IR-7B) 360 x 340 x 250 mm (IR-5C) 15 kg 9.2kg (IR-7S/IR-7B) (IR-5C)
IR-6S/IR-6B/IR-6SD/IR-6BD/IR-5S/IR-5B/IR-4C Power Fuse Lamp Dimension Weight AC 120V~60Hz 20mm Glass 6.3A Fast Blow ELC 24V 250W CDM 150W (IR-6SD/IR-6BD) 695 x 340 x 250 mm (IR-6S/6B/6SD/6BD/5S/5B) 360 x 340 x 250 mm (IR-4C) 10.6 kg (IR-6S/IR-6B/IR-5S/IR-5B) 10.7 kg (IR-6SD/IR-6BD) 8 kg (IR-4C) AC 230/240/250V~50/60Hz 20mm Glass 5A Fast Blow
IS-6S/IS-6B/IS-4/IS-3 Power Fuse Lamp Dimension Weight AC 120V~60Hz 20mm Glass 6.3A Fast Blow ELC 24V 250W 685 x 380 x 200 mm (IS-6S/IS-6B) 375 x 380 x 200 mm (IS-4/IS-3) 9.4 kg (IS-6S/IS-6B) 7.5 kg (IS-4/IS-3) AC 230/240/250V~50/60Hz 20mm Glass 5A Fast Blow
User Guide
WWW.BEGLEC.COM
Innovation , Quality , Performance
.
7. Fixture Cleaning
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which TABLE OF CONTENTS 1. Safety Instruction 2. Technical Specification 2.1 Inserting/Exchanging rotating gobos 2.2 Beam Angel 3. Lamp 4. How To Set The Unit 4.1 Control Panel 4.2 Main Function 5. How To Control The Unit 5.1 Master/Slave Built-In Preprogrammed Function. 5.2 Easy Controller 5.3 iSolution Operation / Universal DMX Controller 5.4 Universal DMX Controller 5.5 DMX512 Configuration 5.6 DMX512 Connection 6. Troubleshooting 7. Fixture Cleaning 2A EN55014-1: 1993, EN61000-3-2: 1995, EN61000-3-3:1995 EN55014-2: 1997 CATEGORY II EN61000-4-2: 1995, EN61000-4-3: 1995, EN61000-4-4:1995 EN61000-4-5: 1995, EN61000-4-6: 1995, EN61000-4-11: 1994 & Harmonized Standard EN60598-1: 1993 Safety of household and similar electrical appliances Part 1 : General requirements Following the provisions of the Low Voltage Directive 73/23/EEC and 93/68/EEC. EC Declaration of Conformity We declare that our products (remote controller) comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility (EMC) Directive 89/336/EEC. EN55015: 1993 EN50082-1: 1997 EN61000-3-2: 1995 EN61000-3-3: 1995 EC Declaration of Conformity We declare that our products (lighting equipments) comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility (EMC) Directive 89/336/EEC. the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit's optics. Clean with soft cloth using normal glass cleaning fluid. Always dry the parts carefully. Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.
6. Troubleshooting
Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting:
1. Safety Instruction
Please read carefully the instruction, which includes important information about installation, operation and maintenance. WARNING 3A Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this user guide. Unpack and check carefully there is no transportation damage before using the unit. Before operating, ensure that the voltage and frequency of power supply match the power requirements of the unit. It's important to ground the yellow/green conductor to earth in order to avoid electric shock. The unit is for indoor use only. Use only in a dry location. The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces. Be sure that no ventilation slots are blocked. Disconnect main power before fuse/lamp replacement or servicing. Replace fuse/lamp only with the same type. Do not use any other type of lamp. Make sure there is no flammable materials close to the unit while operating as it is fire hazard. Use safety cable when fixes this unit. Don't handle the unit by taking its head only, but always by taking its base. Maximum ambient temperature is TA: 40. is higher than this. Unit surface temperature may reach up to 85C. Don't touch the housing bare-hand during its operation. Turn off the power and allow about 15 minutes for the unit to cool down before replacing bulb or serving as the unit could be very hot. In the event of serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts. Don't connect the device to any dimmer pack. Do not touch any wire during operation as high voltage might be causing electric shock. Don't operate it where the temperature
A. The unit does not work, no light and the fan does not work 1. Check the connect power and main fuse. 2. Measure the mains voltage on the main connector. 3. Check the power on LED. B. Not responding to DMX controller 1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly. 2. If the DMX LED is on and no response to the channel, check the address settings and DMX polarity. 3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the unit or the previous one. 4. Try to use another DMX controller. 5. Check in the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit. C. Some units don't respond to the easy controller 1. You may have a break in the DMX cabling. Check the LED for the response of the master/ slave mode signal. 2. Wrong DMX address in the unit. Set the proper address. D. No response to the sound 1. Make sure the unit that does not receive DMX signal. 2. Check microphone to see if it is good by tapping the microphone E. One of the channels is not working well 1. The stepper motor might be damaged or the cable connected to the PCB is broken. 2. The motor's drive IC on the PCB might be out of condition. F. The lamp is cutting out intermittently 1. The lamp is not working well. Check the main voltage either too high or too low. 2. Internal temperature may be too high. Check and if necessary replace the fan on the head.
.
Warning To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture. Never touch bulb with bare fingers as it is very hot after using. Hot lamp explosion hazard. Do not open the unit within five minutes after switching off. Do not start on the unit without bulb enclosure or housing are damaged. The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged. Do not look directly at the light while the bulb is on.
5.5 DMX512 Connection
The DMX512 is widely used in intelligent lighting control, with a maximum of 512 channels.
Caution There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact your nearest dealer. Installation The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 20 kgs for each unit 1.If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin adapter-cable. 2.At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last unit. 3.Connect the unit together in a `daisy chain` by XLR plug from the output of the unit to the input of the next unit. The cable can not branched or split to a `Y` cable. DMX512 is a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors can easily distort the signal and shut down the system. 4.The DMX output and input connectors are pass-through to maintain the DMX circuit, when power is disconnected to the unit. 5.Each lighting unit needs to have an address set to receive the data sent by the controller. The address number is between 0-511 (usually 0 & 1 are equal to 1). 6.The end of the DMX512 system should be terminated to reduce signal errors. 7.3 pin XLR connectors are more popular than 5 pin XLR.
4A
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+) 5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
IS-3
2. Technical Specification
· VoltageAC 120V~60Hz or 230V/240V/250V~50/60Hz · BulbMSD 250W (IR-7S/IR-7B/IR-5C) CDM 150W (IR-6SD/IR-6BD)
ELC 24V 250W (IR-6S/IR-6B /IR-5S/IR-5B/ IR-4C/IS-6S/IS-6B/IS-4/IS-3) · The unit is DMX512 fixture. It features full DMX512 control. It can also be linked together in master/slave connection, as many as required in and run by built-in program chase sequences automatically or by sound activation through an internal microphone to create an intelligent effect. · It can be operated by DMX512 control or can be used as an individual unit without a controller. · Consistent DMX channel enable iRock, iShow and iMove to be link together. · Features different preprogrammed chase patterns. · Please use a 3 pin XLR cable/plug when connecting units together. · Accurate focusable optics system and ultra smooth stepping motors. Fan cooling. · Pan : 180 deg. Tilt : 70 deg. (IR-7S/IR-7B/IR-6SD/IR-6BD/IR-6S/IR-6B/IR-5S/IR-5B/ 5A IS-6S/IS-6B) · IR-7S/IR-7B Independent gobo wheel with 7 rotating, replaceable gobos plus open, including 4 metal, 2 glass and 1 effect gobos with shaking effect, Independent color wheel with 9 dichroic colors with rainbow effect, and independent shutter & dimmer. · IR-6S/IR-6B Independent gobo wheel with 14 gobos plus open and blackout, including 10 metal, 1 replaceable gobo, 2 glass and 1 effect gobos with shaking effect, Independent color wheel with 11 dichroic colors with rainbow effect, and independent shutter & dimmer. (IR-5S/IR-5B without dimmer). · IR-5C Independent gobo wheel with 7 rotating, replaceable gobos plus open, including 1 metal, 2 glass, 1 effect, 1 frost gobos, and 2 color temperature filters (5600k & 3200k) with shaking effect, Independent color wheel with 9 dichroic colors with rainbow effect, and independent shutter & dimmer. · IR-4C Independent gobo wheel with 14 gobos plus open and blackout, including 7 metal, 1 replaceable, 1 effect, 1 frost, 2 glass, gobos, and 2 color temperature filters (5600k & 3200k), with shaking effect, Independent color wheel with 11 dichroic colors with rainbow effect, and independent shutter & dimmer. · IS-6S/IS-6B/IS-4 Professional multi-gobo rotator 14 gobos plus open and blackout, including 10 metal, 1 replaceable gobo, 2 glass and 1 effect gobos, with shaking and shutter effect, Independent color wheel with 11 dichroic colors with rainbow effect.
· IS-3 Professional multi-gobo rotator 14 gobos/colors plus open and blackout, including 10 metal, 1 replaceable gobo, 2 glass and 1 effect gobos, with shaking and shutter effect.
2.1 Inserting/Exchanging rotating gobos ( For IR-7S/IR-7B/ IR-5C only ! )
DANGER! Install the gobos with the device switched off only. Unplug from mains before!
Open the cover by loosening the fastening screw at the sides of the cover. If you wish to use other forms and patterns as the standard-gobos, or if the gobos are to be exchanged, remove the fixation ring with an appropriate tool. Remove the gobo and insert the new gobo. Press the fixation-ring together and insert it in the front of the gobo.
6A
CAUTION! Never unscrew the screws of the rotating gobo as the ball bearing will otherwise be opened!
IS-6S/IS-6B/IS-4 ( IS-4 is a 4-channel gobo rotator )
IR-6SD/IR-6BD/IR-6S/IR-6B/IR-4C ( IR-4C is a 4-channel color changer)
7A
2.2 Beam Angel
3. Lamp
In case of replacement of the lamp or maintenance, do not open the fixture within 15 minutes until the unit cools down after switching off. MSD 250/2 GY 9.5(IR-7S/7B/IR-5C) CDM ( IR-6SD/ IR-6BD )
ELC 24V 250W (IR-6S/IR-6B/IR-5S/IR-5B/ IR-4C/IS-6S/IS-6B/IS-4/IS-3)
Diagram for lamp changing
Because of its high internal pressure, there might be a risk that the Discharge lamp would explode during operation. The lamp emits intense UV radiation which is harmful to the eyes and skin. The high luminance of the arc can cause severe damage to the retina if looks directly at the lamp.
1. Always switch off the main supply and never 8A handle the lamp or luminaries when is hot. 2. Do not touch the bulb with bare hands. If this happens, clean the lamp with denatured alcohol and wipe it with a lint free cloth before installation. 3. The lamp generates UV radiation. Never operate the lamp without appropriate shi ...
|