9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your Epilator BRAUN 8985 : user manual, user guide, instruction manual.
Search a brand
Advanced Search

Need help using a product?
Look at the reviews on BRAUN 8985

User manual BRAUN 8985

Diplodocs help download the user guide BRAUN 8985 Epilator.

Download the complete user guide (2618 Ko)




You may also download the following manuals related to this product:
BRAUN 8985 MANUAL 2
BRAUN 8985 MANUAL 3
BRAUN 8985 MANUAL 4


Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide BRAUN 8985

Detailed instructions for use are in the User's Guide.

8990 8986 8985 on off elect clean eco auto s cartridge normal intensive fix anin g full 80 100 trim empty 0...20 40 8990 reset replace foil+cutter 60 Type 5647, 5649 Modèle 5647, 5649 Modelo 5647, 5649 www.braun.com/register 5-647-446/00/III-06 English Français Español 4 15 25 Thank you for purchasing a Braun product. We hope you are completely satisfied with your new Braun shaver. If you have any questions, please call: US residents 1-800-BRAUN-11 1-800-272-8611 Canadian residents 1-800-387-6657 Merci d'avoir fait l'achat d'un produit Braun. Nous espérons que vous serez pleinement satisfaite de votre nouveau rasoir Braun. Si vous avez des questions, veuillez appeler Braun Canada : 1-800-387-6657 Gracias por haber comprado un producto Braun. Esperamos que Ud. quede completamente satisfecha con su nueva afeitadora Braun. Si Ud. tiene alguna duda, por favor llame al: 01(800) 508-5800 USA/CDN/MEX Printed in Germany Imprimé en Allemagne Impreso en Alemania 1 8 sta rt cle aning 2 Series cartri dg e au to se le ct 8000 full empty 3 intensive normal eco clean 4 16 17 18 19 20 7 6 5 fix on 8985 empty charge trim off 8985 12 fix on off 18 19 20 fix on reset replace foil+cutter 8986 trim 8986 8987 off reset replace foil+ cutter 360°Complete 8990 0 20 40 60 80 100 trim 8990 14 13 reset replace foil+cutter 10 11 12 9 Series 16 17 18 19 15 11 10 8000 20 21 English IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precautions should always be followed, including the following: Read all instructions before using this appliance. DANGER To reduce the risk of electric shock: 1. Do not reach for an appliance that has fallen into water. Unplug immediately. 2. Do not use while bathing or in a shower when the appliance is connected to an electrical outlet. 3. Do not place, store or charge the appliance where it can fall or be pulled into a tub or sink. Do not place in or drop into water or other liquid. 4. When not using for an extended period of time, unplug this appliance from the electrical outlet. 5. Unplug this appliance before cleaning. 6. This appliance comes provided with a special cord set with integrated Safety Extra Low Voltage power supply. Do not exchange or manipulate any part of it. FOR HOUSEHOLD USE SAVE THESE INSTRUCTIONS 4 WARNING To reduce the risk of burns, fire, electric shock, or injury to persons: 1. Close supervision is necessary when this appliance is used by, on, or near children or individuals with disabilities. 2. Use this appliance only for its intended use as described in this manual. Do not use attachments that are not recommended by the manufacturer. 3. The appliance should never be exposed to temperatures of less than 32 ºF / 0 ºC and more than 105 ºF/+ 40 ºC for longer than a few hours. Be sure to completely dry appliance after use. Keep cord and adapter dry at all times. Do not store in a damp environment. To avoid damage do not wind the cord around the appliance. It is important to check the cord for damage periodically particularly at each end where the cord enters the plug. 4. Never operate this appliance if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Return the appliance to a service center for examination and repair. 5. Keep the cord away from heated surfaces. 6. Never drop or insert any object into any opening. 7. Do not use outdoors or operate where aerosol (spray) products are being used or where oxygen is being administered. 8. Do not use this appliance with a damaged or broken foil, as serious facial injuries may occur. 9. Always attach plug to appliance first, then to outlet. To disconnect, turn all controls to «off», then remove plug from outlet. 5 Your 360° Complete (shaver with Clean&RenewTM station) is a system equipped with highly advanced electronic processors. It ensures unsurpassed closeness and comfort for you and optimum care for your shaver: · The system automatically adapts to any voltage worldwide. · The system recognizes when cleaning of your shaver is required, and automatically recognizes which of the three cleaning programs is appropriate. · While the shaver is connected to an electrical outlet, the system automatically takes care of charging and discharging in a way that is optimized for the shaver's battery capacity and life span. · The system takes care of lubrication of the shaver's cutting parts. · The system tells you when to replace the shaving foil and cutter block. Important In order to avoid any leakage of the cleaning fluid, place the Clean&RenewTM station on a flat, stable surface. Do not tip, move suddenly or transport the station in any way if a cleaning cartridge is installed. Do not place the station in a mirror cabinet, store it over radiators, or place it on polished or laquered surfaces. Do not expose to direct sunlight. The station contains highly flammable liquid. Keep it away from sources of ignition. No smoking. Keep out of reach of children. Do not refill cartridge. Use only original Braun refill cartridge. 6 Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Special cord set «start cleaning» button Station-to-shaver connecting contacts Station lift button for cartridge exchange Display for cleaning programs Display for cleaning fluid status Station mains socket Cleaning cartridge Shaver foil protection cap Shaver foil Cutter block Foil release buttons Long hair trimmer Shaver-to-station connecting contacts (shaver backside) Switch Shaver charging lights (green) Shaver low-charge light (red) Replacement light for shaving parts Reset button Pilot light Shaver mains socket to se eco normal intensive Before shaving If you wish, you may start shaving right away (if the shaver is charged, see section «The shaver indicator lights»). However, we recommend to follow the procedure described here: · Using the special cord set (1), connect the socket of the Clean&RenewTM station (7) to an electrical outlet. idg e ca rtr empty au full l clean lec t to se eco normal intensive au full empty 1 · Press the station lift button (4) to open the housing. · Hold the cleaning cartridge (8) down on a flat, stable surface (e.g. table). · Carefully remove the lid from the cartridge. · Slide the cartridge into the base of the station as far as it will go. · Slowly close the housing by pushing it down until it locks. cart ridg e clean 2 cart ridg e clean lec t to se eco normal intensive cart ridg e full empty lec t to se eco normal intensive full empty au au 7 a cartrid ge full b cartrid ge full c cartrid ge full The display for cleaning fluid (6) will show how much cleaning fluid is in the cartridge: a) cleaning solution sufficiently available b) up to 7 cleanings left c) new cartridge required Make sure the foil protection cap (9) is removed from the shaver. Insert the shaver head down into the station (the contacts (14) on the back of the shaver will correspond to the contacts (3) in the station). If necessary, the system will now charge the shaver. Also, the cleaning status will be automatically analyzed and one of the four diodes of the cleaning program display (5) will light up: a) the shaver is clean b) eco(nomic), i.e. short cleaning required c) normal cleaning required d) intensive cleaning required If the system has selected one of the three cleaning programs, it will not start until you push down the «start cleaning» button (2). This locks the shaver into the station and starts the cleaning process. We recommend cleaning after each shave. While the cleaning is in progress, the respective cleaning program light will flash. Each cleaning consists of several cycles (where the cleaning fluid is flushed through the shaver head) and a heat drying period. The total cleaning time is 33 to 50 minutes. Cleaning processes in the Clean&RenewTM should not be interrupted. While the shaver is drying, the metal parts of the shaver may be hot. Also, if the shaver is taken out prematurely and is not dry, its electronics could be harmed. empty empty empty sele ct auto selec t auto trim clean fix on eco normal intensive clean eco a b c d off normal intensive sta cartridge rt cleaning full empty 8990 clean sele ct auto ect auto sel cartridge sele c t auto reset 80 100 0..20 40 60 er foil replacel+cutt eco normal intensive start clea nin g trim fix clean eco on off normal intensive full empty clean eco normal intensive When the program is finished, the blue «clean» light will shine. You can release the shaver by pushing the «start cleaning» button. Your shaver is now clean and ready for use. 8 Shaving fix fix trim fix on If the shaver is locked into the Clean&RenewTM station, push the «start cleaning» button (2) to release the shaver and take it out. Switch positions off = (switch is locked) Press and push up the switch to operate the shaver. on = Shaving with the pivoting head (the pivoting cutting system automatically adjusts to every contour of your face). fix = Shaving with the pivoting head locked at an angle (to permit shaving in difficult areas, e.g. under the nose). trim=The long hair trimmer is activated (for trimming sideburns, moustache and beard). Tips for the perfect shave · It can take up to 14-21 days for your beard to adjust to the new shaving system. · Shave before washing your face or taking a shower, as skin tends to swell after washing. · The drier the skin, the closer the shaving results will be. · Hold the shaver at right angles (90°) to the skin. Stretch the skin and shave against the direction of beard growth. · To maintain 100% shaving performance, replace your foil and cutter block at least every 18 months or when worn. Shaving with the cord If the shaver is completely discharged and you do not have the time to recharge in the Clean&RenewTM station, you may also shave with the shaver connected to an electrical outlet. on on After shaving Automatic cleaning After each shave, return the shaver to the Clean&RenewTM station and proceed as described above in the section «Before shaving». All charging and cleaning needs are then taken care of. With daily use, a cleaning cartridge should be sufficient for about 30 cleaning cycles. The hygienic cleaning solution cartridge contains alcohol which, once opened, will naturally evaporate slowly into the surrounding air. Each cartridge, if not used daily, should be replaced after approximately 8 weeks. 8990 reset 80 100 0..20 40 60 clean selec t eco auto normal intensive cartridge start cleaning full empty 8990 foil replacel+cutter trim fix on off 9 Quick cleaning Press the foil release buttons (12) to lift the shaver foil (do not remove the foil completely). Switch on the shaver for approx. 5­10 seconds so that the shaved stubbles can fall out. off Thorough manual cleaning Manual cleaning is recommended only when the Clean&RenewTM station is not available, e.g. when travelling. Never use water to clean the shaver. Remove the shaver foil and tap it out on a flat surface. Using the brush, clean the inner area of the pivoting head. However, do not clean the shaver foil nor the cutter block with the brush as this may damage them. If you do not use the Clean&RenewTM station for a longer period of time, you should apply a drop of light machine oil onto the shaver foil. Cleaning the housing Clean the housing of shaver and station from time to time with a damp cloth, especially inside the opening of the station where the shaver rests. Replacing the cartridge After having pressed the lift button (4) to open the housing, wait for a few seconds before removing the used cartridge. Before discarding the used cartridge, make sure to close the openings using the lid of the new cartridge, since the used cartridge will contain contaminated cleaning solution. fix on on off old new The shaver indicator lights replace Pilot light (20): the shaver is connected to an electrical outlet. 0..20 40 60 replace foil+cutt 8990 reset replace foil+cutt empty charge 0...20 40 The red low-charge light (17) flashes when the battery capacity has dropped below 20%, provided the shaver is switched on. The remaining capacity will then be sufficient for 2 to 3 shaves. 60 80 100 10 replace foil+cutt Model 8986: When the shaver is fully charged, all three charging lights (16) will light up, provided the shaver is plugged in or switched on. Model 8985: The green single charging light (16) shows that the shaver is being charged. When fully charged, the charging light flashes or turns off. If later on, the charging light turns on again, this indicates that the shaver is being recharged to maintain its full capacity. Charging information A full charge will give up to 50 minutes of cordless shaving time, depending on your beard growth. Best environm ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.