Detailed instructions for use are in the User's Guide.
Pulsonic
®
9595
washable
rt cleaning sta
clean
eco
norma
fa st cl
ea n
l
ve intensi
auto s elect
high
trimmer
low empty
off
reset
on
Type 5671 Modèle 5671 Modelo 5671
www.braun.com/register
English Français Español
4 15 25
Thank you for purchasing a Braun product. We hope you are completely satisfied with your new Braun shaver. If you have any questions, please call: US residents 1-800-BRAUN-11 1-800-272-8611 Canadian residents 1-800-387-6657 Merci d'avoir fait l'achat d'un produit Braun. Nous espérons que vous serez pleinement satisfait de votre nouveau rasoir Braun. Si vous avez des questions, veuillez appeler Braun Canada : 1-800-387-6657 Gracias por haber comprado un producto Braun. Esperamos que quede completamente satisfecho con su nueva afeitadora Braun. Si tiene alguna duda, por favor llame al: 01(800) 508-5800
5-671-453/00/II-07 USA / CDN / MEX Printed in Germany Imprimé en Allemagne Impreso en Alemania
3
4 4a
8
9
rt cleaning sta
clean
10 5
trimmer
eco
normal
fast cl e a n
ive intens
au ct to sele
11
high
2 1
low empty
6
on
12
off
reset
13 14
7
15
18
16 17
w as hab le
res
et
trim m m me r
English
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical appliance, basic precautions should always be followed, including the following: Read all instructions before using this appliance. When disconnected, the hand-held part of this shaving appliance may be cleaned under water.
DANGER
To reduce the risk of electric shock: 1. Use only in dry condition. 2. Do not submerge in water. 3. Do not reach for an appliance that has fallen into water. Unplug immediately. 4. Do not use while bathing or in a shower. 5. Do not place, store or charge the appliance where it can fall or be pulled into a tub or sink. Do not place in or drop into water or other liquid. 6. Except when charging, always unplug this appliance from the electrical outlet immediately after using. 7. Unplug this appliance before cleaning. 8. This appliance is provided with a special cord set with integrated Safety Extra Low Voltage power supply. Do not exchange or manipulate any part of it. 9. Do not use an extension cord with this appliance.
FOR HOUSEHOLD USE ONLY
4
WARNING
To reduce the risk of burns, fire, electric shock, or injury to persons: 1. Close supervision is necessary when this appliance is used by, on, or near children or invalids. 2. Use this appliance only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer. 3. Never operate this appliance if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or if the power supply has been dropped into water. Return the appliance to a service center for examination and repair. 4. Keep the cord away from heated surfaces. 5. Never drop or insert any object into any opening. 6. Do not use outdoors or operate where aerosol (spray) products are being used or where oxygen is being administered. 7. Do not use this appliance with a damaged or broken foil, as serious skin injuries may occur. 8. Always attach plug to appliance first, then to outlet. To disconnect, turn all controls to «off», then remove plug from outlet. 9. When plugging to an electrical outlet outside the USA, use a plug adapter to match the outlet's pin configuration.
SAVE THESE INSTRUCTIONS
5
Warning To prevent the cleaning fluid from leaking, ensure that the Clean&Renew station is placed on a flat surface. When a cleaning cartridge is installed, do not tip, move suddenly or transport the station in any way as cleaning fluid might spill out of the cartridge. Do not place the station inside a mirror cabinet, nor place it on a polished or lacquered surface. The cleaning cartridge contains a highly flammable liquid so keep it away from sources of ignition. Do not expose to direct sunlight and cigarette smoking nor store it over a radiator. Keep it out of reach of children. Do not refill the cartridge and use only original Braun refill cartridges.
Description
Clean&Renew station 1 Cleaning fluid display 2 Lift button for cartridge exchange 3 Station-to-shaver contacts 4 «start cleaning» button D «fast clean» button 5 Cleaning program diodes 6 Station power socket 7 Cleaning cartridge Shaver 8 Foil & cutter cassette 9 Cassette release button 0 Shaver head «lock» switch q Pop-out long hair trimmer w On/off switch e «reset» button r Shaver display t Shaver-to-station contacts z Shaver power socket u Travel case i Special cord set
6
Before shaving
Prior to first use you must connect the shaver to an electrical outlet using the special cord set i or alternatively proceed as below. Installing the Clean&Renew station · Using the special cord set i, connect the station power socket 6 to an electrical outlet. · Press the lift button 2 to open the housing.
high low empty
sta
clean
eco
norm al
auto sel
intens ive
ect
rt cleaning
clean
eco
al norm
n
fast clea
inten
auto
sive
ct
sele
· Hold the cleaning cartridge 7 down on a flat, stable surface (e.g. table). · Carefully remove the lid from the cartridge. · Slide the cartridge into the base of the station as far as it will go. · Slowly close the housing by pushing it down until it locks. The cleaning fluid display 1 will show how much fluid is in the cartridge:
1
2
fast clean
new
sta
rt cleaning
clean
eco
norm
intens
auto
al
sta
rt cleaning
clean
ive
eco
l norma
intens
auto
fast clean
high low empty
t selec
ive
fast clean
high low empty
t selec
fast clean
fast clean
high
high low empty
high low empty
«high» up to 30 cleaning cycles available «low» up to 7 cleaning cycles remaining «empty» new cartridge required
low empty
If required, the Clean&Renew station will now charge the shaver. The hygiene status of the shaver will also be analyzed and one of the following cleaning program diodes 5 will light up: «clean» «eco» «normal» «intensive» shaver is clean short economical cleaning required normal level of cleaning required high intensive cleaning required
high
low empty
sta
fa st clea n
high
low
ble washa
If the station selects one of the required cleaning programs, it will not start unless you press the «start cleaning» button 4. For best shaving results, we recommend cleaning after each shave.
wash
able
reset
Charging and cleaning the shaver Insert the shaver head down into the cleaning station. (The contacts t on the back of the shaver will align with the contacts 3 in the cleaning station).
trimm er
sta
rt cleaning
clean
eco
normal
fast clea
n
ve intensi
auto select
rt cleaning
clean eco normal intensive auto select
s ta
rt cleaning
clean
eco
normal
fast cle
an
intensive
auto sele ct
7
While cleaning is in progress, the respective cleaning program diode will blink. Each cleaning program consists of several cycles, where cleaning fluid is flushed through the shaver head and a heat drying process dries the shaver. Depending on the program selected the total cleaning time will range from 32 to 43 minutes. The cleaning programs should not be interrupted. Please note that while the shaver is drying, the shaving head may be hot and wet. When the program is finished, the blue «clean» diode will light up. Your shaver is now clean and ready for use. Fast cleaning Push the «fast clean» button D to activate the fast clean program without drying. This program takes about 25 seconds only and is recommended when you do not have time to wait for one of the automatic cleaning programs. If you remove the shaver just after the program has finished, wipe off the shaver head with a tissue to avoid dripping. Stand-by mode 10 minutes after completing the charging or cleaning session, the Clean&Renew station switches to the stand-by mode: The diodes of the Clean&Renew station turns off.
sta
rt cleaning
clean eco normal
fa st clea n
intensive auto select
high
low empty
8
ble washa
s ta
rt cleaning
clean
eco
normal
fast
cle an
intensive
ct auto sele
Shaver display
The shaver display r shows the charge status of the battery on the left, and the hygiene status on the right. (6 dark segments are shown on each side when the battery is fully charged and the shaver is hygienically clean). Battery segments: During charging or when using the shaver, the respective battery segments will blink. When fully charged all 6 segments are shown. With decreasing charge the segments gradually disappear. Low charge indicator: The low charge segment provided with a red frame blinks to indicate that the charge has dropped below 20%. The remaining capacity is sufficient for 2 to 3 shaves.
Hygiene segments: All 6 hygiene segments will appear after the shaver has been cleaned in the Clean&Renew station. When the shaver is being used, the hygiene segments will gradually disappear. Once the shaver is returned to the station, the system will automatically select the appropriate cleaning program and restore the segments to maximum hygiene. Given that rinsing the shaver under tap water is not as hygienic as the cleaning station, the hygiene segments will only restore themselves when the shaver has been cleaned in the Clean&Renew station. Charging information · A full charge provides up to 50 minutes of cordless shaving time. This may vary according to your beard growth. · The best environmental temperature for charging is between 41 °F to 95 °F / 5 °C to 35 °C. Do not expose the shaver to temperatures higher than 122 °F / 50 °C for extended periods of time.
Shaving
Press the on/off switch w to operate the shaver: · The pivoting shaver head and floating foils automatically adjust to every contour of your face. · To shave hard to reach areas (e.g. under the nose) slide the shaver head «lock» switch 0 to the back position to lock the pivoting head at an angle. · To trim sideburns, moustache or beard, slide the pop-out long hair trimmer q upwards.
trimmer
off
on
tr
reset
1
loc
k
2
lock
lo
ck
lock
Tips for the perfect shave For best shaving results, Braun recommends you follow 3 simple steps: 1. Always shave before washing your face. 2. At all times, hold the shaver at right angles (90°) to your skin. 3. Stretch your skin and shave against the direction of your beard growth.
off
release
on
9
Shaving with the cord If the shaver has run out of power (discharged), and you do not have the time to recharge it in the Clean&Renew station, you may also shave with the shaver connected to an electrical outlet via the special cord set i.
Cleaning
Automatic cleaning After each shave, return the shaver to the Clean&Renew station and proceed as described above in the section «Before shaving». All charging and cleaning needs are then automatically taken care of. With daily use, a cleaning cartridge should be sufficient for about 30 cleaning cycles. The hygienic cleaning cartridge contains alcohol, which once opened will naturally evaporate slowly into the surrounding air. Each cartridge, if not used daily, should be replaced after approximately 8 weeks. The cleaning cartridge also contains lubricates, which may leave residual marks on the outer foil frame after cleaning. However, these marks can be removed easily by wiping gently with a cloth or soft tissue paper. Manual cleaning The hand-held unit shall be detached from the power supply cord before cleaning. The shaver shall not be used until it has dried. Rinsing the shaving head under running water is an alternative way to keep the shaver clean, especially when travelling: · Switch the shaver on (cordless) w and rinse the shaving head under hot running water. You may use liquid soap without abrasive substances. Rinse off all foam and let the shaver run for a few more seconds.
washable
high
low empty
release
on
er
release
washable
click!
trimmer
release
10
e washabl
ab s sh wa
reset
er trimm
sta
rt cleaning
clean
eco
norma l
fast clea
n
ive intens
auto select
le
trim e me r
· Next, switch off the shaver, press the release button 9 to remove the foil and cutter cassette 8 and let it dry.
oil
· If you regularly clean the shaver under water, then once a week apply a drop of light machine oil on top of the foil and cutter cassette.
Alternatively, you may clean the shaver using the brush provided: · Switch off the shaver. Remove the foil and cutter cassette 8 and tap it out on a flat surface. Using the brush, clean the inner area of the pivoting head. However, do not clean the cassette with the brush as this may damage it. Cleaning the housing From time to time clean the housing of the shaver and the Clean&Renew station with a damp cloth, especially inside the cleaning chamber where the shaver rests. Replacing the cleaning cartridge After having pressed the lift button 2 to open the housing, wait for a few seconds before removing the used cartridge to avoid any dripping. Before discarding the used cartridge, make sure to close the openings u ...