USER INSTRUCTIONS INSTALLATION INSTRUCTIONS SERVICE INSTRUCTIONS This heater is approved for use with Natural and Propane gases. Please leave instructions with the owner
Contents
Contents Warranty Safety warnings What to do if you smell gas Warnings Standards User instructions Operating instructions Cleaning Heater specifications Alternative flue Installation instructions Clearances Installation Gas connection Fuel bed & log installation Gas pressure point Flue installation Flue kit Alternative double skin flue installation Alternative flue kit Service instructions General Access to components To replace the gas control To replace the fan To replace the electronic controller To check or change fuse To remove the burner and electrodes Trouble shooting Wiring diagram Authorised service agents 18-20 14-15 10 9 6 2 3 4
2
Warranty
The Cannon appliance is warranted against defects in materials and workmanship for a period of one, (1) year from its date of original purchase, for residential use in Australia. Warranty service, which includes parts and labour for the replacement or repair of defective parts, is available through Cannon Authorised Service Agencies. (Please refer to the list of authorised service agents in this manual.) Consumers are responsible for service person's travel outside normal service areas (approximately seventy (70k) radius from the nearest Cannon dealer's location), local cartage, and normal maintenance as described in this manual. Any product subjected to misuse, abuse, negligence, accident or alteration will have its warranty voided. The defacement of serial plate will have it's warranty voided. If installation is not carried out in accordance with manufacturer's instructions, this warranty may be void. The customer must keep their "Tax Invoice" as proof of purchase of this product, and compliance certificate as proof of required installation.
Model number: ______________________________________ Serial number: _______________________________________ Date of manufacture: _________________________________ Date installed: _______________________________________ Compliance Certificate No: ____________________________
Don't risk your appliance warranty Only a licensed person will give you a Compliance Certificate, showing that the work complies with all the relevant standards. And only a licensed person will have insurance protecting their workmanship for 6 years. So make sure you use a licensed person to install this appliance and ask for your Compliance Certificate to ensure the manufacturers appliance warranty will be honoured.
3
Safety Warnings
Please read this manual before installing and using the heater.
What to do if you smell gas
1. Turn OFF the main gas supply. 2. Extinguish any open flame. 3. Open windows. 4. Do not touch electrical switches. 5. Do not use your telephone. 6. Call your gas supplier immediately from a neighbour's phone.
Warnings
1. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to other sections of this manual for correct procedures, or consult with place of purchase, a licensed plumber, a gas supplier or service agent listed in this manual. 2. Due to high temperatures the room heater should be located out of traffic and away from:
· · ·
Furniture and draperies, Combustible materials, Gasoline and other flammable liquids,
Do not place clothing or other flammable material on or near the heater. 3. Keep curtains*, clothing, furniture and other flammable materials at least 900mm from front, rear and sides of the heater. * At the owner's discretion curtain clearance can be less than 900mm as long as they are restrained from the front, top and sides of the heater. The manufacturer takes no responsibility if curtain clearance is less than 900mm and not restrained. 4. Children and adults should be alerted to the hazard of high surface temperature and should take care to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the heater. 5. Never attempt to burn paper or any other material in the heater. 6. Do not spray aerosols in the vicinity of this appliance while it is in operation. 7. If removed the glass window must be put back onto the unit prior to operating the heater.
8. Installation and repairs should be performed by a licensed service person only, refer to back of brochure for service number.
4
9. The appliance should be inspected prior to use, with regular inspections (annually) to be made by a licensed service person. It is important that circulating air passageways of the appliance be kept clean, dirt and lint free, for a safe and efficient operation of the heater. 10. On first lighting your heater a smell may occur due to it's new condition. This is quite normal and will disappear after a few hours use at the maximum control position. Important: WHEN THIS HEATER IS OPERATING, THE GLASS FRONT IS HOT. A safety guard conforming to AGA requirements is available for this heater. It is an optional extra, which may be fitted to the heater to reduce the risk of fire or injury from burns. Its fitting is recommended when there are children present. For permanent protection of young children or the infirm, an optional mesh guard is recommended. Call your retailer or authorised service agent for further details.
Standards
This appliance meets the following standards: Standards Australia: AS 3100 AS 5601/AG 601 AS 4553/AG 103
5
User instructions
Operating instructions
The Australian Gas Association: AG 103 1. Plug the power cord into the wall socket and turn on the power to the heater, see figure 1. Use of an extension cord is not recommended
1
2. For control lay-out refer to figure 2
2
3. To turn heater on press switch to POWER ON position. There is a 5 second delay before the burner ignites. At this setting the burner is on LOW and the fan speed is on LOW. Refer figure 3. The burner will ignite on both HIGH and LOW settings.
3
4. To turn burner to HIGH setting, press switch for HIGH setting. Refer figure 4.
4
6
5. To increase the fan speed to MED, press switch for MED setting. Refer figure 5.
5
6. To increase the fan speed to HIGH, press switch for HIGH setting. Refer figure 6.
6
7. To turn the burner to LOW setting, press switch for LOW setting. Refer figure 7. On low burner setting it is more efficient to operate the fan speed on LOW.
7
8. If the burner fails to ignite, wait 20 seconds and repeat the ignition porcedure. See below. To turn burner OFF To turn burner ON
7
User instructions continued
Cleaning.
All cleaning should be carried out when the heater is cold. Normally the heater should only need wiping with a lint - free damp cloth. Any stubborn stains can be removed with a non-abrasive spray on cleaner. If an abrasive cleaner is used the paint finish will be damaged. Internally the heater should only be cleaned by a licensed service person listed in this manual. If your heater requires attention contact your supplier or licensed service person listed in this manual. Important: The appliance should be inspected before use and at least annually by an authorised service person. More frequent cleaning may be required due to excessive lint build-up from carpeting, bedding materials, pet hair, etc. It is imperative that control compartments, burners and circulating air passage ways of the appliance be kept clean. Do not use this fire if the glass is cracked or with the glass safety screen removed. Do not use fire with broken or missing logs.
8
Installation Instructions
1. This appliance is to be installed by a licensed service person only. 2. This appliance is to be installed in accordance with the manufacturer's installation instructions, AS 5601/AG601, Municipal Building Codes, Electrical Wiring Regulations and any other statutory regulations.
Clearances
3. Ensure the minimum clearances to combustible construction are maintained during installation, including adequate space for the proper operation and servicing of the heater. For clearances to curtains and furnishing refer to warning 3 on page 4 For minimum clearances refer fig 9 and 10.
9
10
Installation
4. Remove the carton from the heater and lift from pallet. Check the heater is suitable for gas available. (Please dispose of packaging appropriately, keep away from children). 5. Prepare electrical and gas connections, a 10 Amp wall socket needs to be located within 1.5m of the heater. 6. Fit rear spacers as per figure 10. 7. Place heater in position. (Check flue and gas connection positions. Refer to gas connection instructions on page 11 and flue installation instructions on pages 14 & 15 and 16 & 17). 8. Remove the pedestal front by unscrewing two screws either side. Refer figure 11. Remove the heater front securing screws, one either side. Refer figure 12.
10
11
12
9. Remove the front glass surround by holding it firmly on either side and pulling it towards yourself, see figure 13.
13
10.Remove the inner glass. Slacken off screws in top clamp and remove side clamps. Refer figure 14.
14
Gas connection
11. Connect incoming gas supply pipe to compression fitting at rear of appliance. For inlet position see figure 15.
15
11
Installation instructions continued
Fuel bed and log installation
12. The fuel bed is contained within the burner chamber. Remove the fuel bed transit packaging. Refer figure 16. The fuel bed is retained by a spring clip fixed to the rear of the burner chamber FUEL BED MUST BE HARD UP AGAINST REAR OF BURNER
16
13. Carefully unpack the log set. Logs are numbered as follows: No 1 - Left front log No 2 - left back log No 3 - Right front log No 4 - Right back log Position the four individually numbered logs in the following order on the fuel bed as shown in figures 17-20. The male locating pins in fuel bed must engage with corresponding holes in the individual logs. a) Place log No.1 onto the 2 front left pins on the fuel bed, see figure 17.
17
b) Place log No.2 onto the 2 left back pins. Refer figure 18.
18
c) Place log No.3 on single right front pin, ensure fork locates over log No. 2, see figure 19.
19
12
d) Place log No. 4 on single right back pin, ensure left side of log rests on depression in No. 3 log, see figure 20.
20
14. Refit the inner glass, but do not overtighten the screws. 15. Refit the front glass surround. Ensure that the glass surround is replaced the correct side up. The rearward sloping frame must be at the top and the vertical ledge must be at the bottom. Refer figure 21.
21
Gas pressure point
16. Using an 8mm spanner remove the pressure point cover and check the outlet pressure of the gas regulator. It should be 1.0 kPa for NG, 2.75 for LP gas. Adjustment for LP gas is at the gas bottle regulator. The outlet pressure point is situated on the RHS top of the gas control. Refer figure 22
22
17. Refit the pedestal cover. 18. Follow User Instructions to turn on heater. Important: To achieve the correct visual flame effect: On Propane the gas pressure must be set at 2.75 kPa with burner operating on maximum setting. On Natural Gas the gas pressure must be set at 1.0 kPa.
13
Flue installation
This heater is a flued appliance. It must be properly connected to a flue system in accordance with the latest edition of the Gas Installation Code, AS 5601/AG 601. If elbows are needed, the total horizontal length depends on the number of elbows used. Venting should never slope down. A 6mm per 500mm horizontal rise is recommended. If practical locate the heater in a position to minimise the use of horizontals and elbows. The flue rise should be a minimum of 1.8m before any horizontal run is used. If placed against a combustible wall the 40mm rear spacers locate against the wall. 1. Ensure clearances to combustible have been observed. For clearances refer page 10. 2. The centre line of the flue is 75mm to rear of appliance (ex cluding rear spacers). 3. Carry out installation as per figure 23 (ceiling plate installation) and figure 24 (flue installation). Cut a hole 180mm ø in the ceiling in line with the flue position. Secure ceiling plate against the ceiling by bending out the tabs above the ceiling. Note: If the ceiling has an incline, the ceiling box will need to be fitted. Installation instructions are supplied with the ceiling box.
20
23
Flue kit
The flue kit contains: 3 x 900mm lengths of 125mm ø painted flue. 1 x 900mm length of 125mm ø plain flue. 1 x ceiling plate 1 x 900mm painted bottom flue spigot.
14
24
15
Installation instructions continued
Alternative double skin flue installation
This heater is a flued appliance. It must be properly connected to a flue system in accordance with the latest edition of the Gas Installation Code, AS 5601/AG 601. If elbows are needed, the total horizontal length depends on the number of elbows used. Ve ...