9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your CITADEL XR1 : user manual, user guide, instruction manual.
Search a brand
Advanced Search

Need help using a product?
Look at the reviews on CITADEL XR1

User manual CITADEL XR1

Diplodocs help download the user guide CITADEL XR1 .

Download the complete user guide (542 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide CITADEL XR1

Detailed instructions for use are in the User's Guide.

Intruder alarm system XR1 8EP 394 XR1 G3 panel with built-in keypad 12345678 Power Operating Instructions These operating instructions cover the following intruder system: 0 5 Chime 1 6 Omit 2 7 Reset 3 8 Prog 4 PA ÿ Attack Tamper 9 Set Day 8EP 394 XR1G3 panel with built in keypad 12345678 Power 0 5 Chime 1 6 Omit 2 7 Reset 3 8 Prog 4 PA Attack Tamper 9 Set Day Key LED steady On indication LED flashing indication LED Off Internal sound Sound description Unset system indications An unset system will have both Day and Power indicators lit. This is a normal Day Power indication when the system is disarmed. NOTE: In general a flat beep is an indication of an incorrect key press. External devices Strobe Bell Note: If the Power indicator goes off at any time then there is a mains supply failure at the security panel, consult your servicing organisation. Set System indication An active `Set' system will have only the Power Power indicator lit. This is an armed system indication. 4188-693 issue 1_8/01 1 Downloaded from: http://www.guardianalarms.net Unset system indications Accenta/! mini For Clarity, the information given on setting the system, assume that all Programs use a timed or final door setting routine. Operating instructions Contents Unset system indications - - - - - - - - Set System indication - - - - - - - - - Access codes - - - - - - - - - - - - - How to operate Personal Attack - - - How to unset system in alarm - - - - - Programs 1, 2 and 3 - - - - - - - - - - How to set the system (on program 1) - Push to Set Switch - - - - - - - - - - - Keyswitch Set - - - - - - - - - - - - - Faults during setting - - - - - - - - - - How to unset the system (turn off) - - How to set program1,2 or 3 - - - - - - How to Quick set - - - - - - - - - - - How to Omit zone(s) on setting system Fire Alarm - - - - - - - - - - - - - - How to set Chime Zones - - - - - - - Operator's Program mode - - - - - - - To exit operation at any time - - - - - - How to enter Operator's program mode How to view the events log - - - - - - How to create/omit User 2 code - - - - How to change current user code - - - How to carry out Alarm and Walk testsServicing organisation details - - - - - - Quick Reference - - - - - - - - - - - - 1 1 2 2 2 2 3 3 3 3 3 3 4 4 4 4 5 5 5 5 6 6 7 7 8 Citadel XR1 G3 Intruder system How to unset system in alarm Enter your code. Entering the code will turn the alarm off and the cause of the alarm will be displayed. After investigation press Reset to clear the indication. n n n n Bell Alarm FIRST ZONE IN ALARM OTHER ZONES IN ALARM Investigate the Alarm Reset ALL ZONE Strobe Off Day Access codes Note: If the alarm indication does not clear, then the system may need to be reset by the installation engineer, contact your installer for further information. Programs 1, 2 and 3 Access codes There are two User codes used in the system, both are 4 digit and can be set to any number from 0000 to 9999, signified by: n n n n The user 1 and 2 codes have the same operation for testing, Setting and Unsetting, but user 1 code which is usually considered to be the Managers code has the authority to add, change or delete the user 2 code. The panel uses 3 Part Set routines known as Programs. In each Program the exit mode can be changed and the zone may be set up to have a different function. The examples below show how 3 typical Programs could be used in a house. Program 1 To arm all of the zones and become Set as the user leaves the property and closes the final door. Program 2 To protect the perimeter of the property in the evening and become Set after say 20 seconds. Program 3 To protect the downstairs areas of the house at night and become Set silently. The above are purely examples. The installer has the ability at the programming stage to configure all the circuits to the customer's exact requirements. ÿ ÿ User 1 code - 0123 factory set User 2 code - not programmed. How to operate Personal Attack Personal Attack buttons on the keypad are used to activate the alarm, irrespective of whether the system is armed or not. Press Simultaneously: 9 4 2 4188-693 issue 1_8/01 Citadel XR1 G3 intruder system Operating instructions How to set the system (on program 1) The green Day indicator should be showing. Enter your code number and check that the system is clear (none of the Day zone indicators are showing). The n n n n sounder will now 10seconds produce an exit Exit beep insistent beeps beep tone and you should leave by Day the approved route. The system will Set as the beep tone stops. How to unset the system (turn off) On entering the premises an entry beep tone come on. Enter your code, the green Day indicator is lit. The system is unset and disarmed. Entry beep Day n n n n Acknowledge Day Push to Set Switch In some systems a Push to Set switch may be fitted outside the premises near to the main exit door. This should be used to complete the setting How to set program 1,2 or 3 procedure once the building has been vacated. As the switch is operated, the exit beep tone will The green Day indicator should be showing. stop and a chime tone will be produced to Enter your code Day acknowledge setting. number and the exit beep tone n n n n will start. Press Exit beep the Prog key and Keyswitch Set the exit tone will ZONE 1-3 Prog Exit beep stop. Press 1, 2 Your system may have been fitted with a remote or 3 for the keyswitch. This can be used as an alternative to 2 Or 3 1 required arming the system with a code and will set program, the Program 1. 10 seconds Exit beep insistent beeps sounder will Where a keyswitch is used it may be necessary beep to Day on occasions to allow it to catch up with the acknowledge the system. For example if the alarm was set with a code, to Unset with the keyswitch, it would have program number. The exit beep tone will start to be momentarily turned to Set then returned to and you should leave by the approved route. The system will Set as the beep tone stops. Unset. It is important that you follow the correct procedure when setting the system. After leaving the protected area it is absolutely essential that you wait until the exit tone stops, before assuming the system has set. Faults during setting If the system is not clear when you try to Set it, the sounder will produce an open zone tone and the fault will be displayed. Either re-enter your code to turn off and investigate or omit the faulty zone(s) from the system. 4188-693 issue 1_8/01 3 How to set the system (on program 1) Operating instructions Citadel XR1 G3 Intruder system How to Quick set During the exit period (on entering User code) the system may be Set quickly by pressing Set. Day Set the system or This removes the exit time period. Set a Program Set 5 seconds insistent beeps Day How to set Chime Zones Example: To set zone 3 and 4 to chime, Press: Chime 3 Day 4 Reset If you omit zones and require Quick Set, you will need to press Set twice. Chime Timeout after 5 seconds if no selection is made Day Chime 0 Deselect all zones (Factory default - no chime) Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Appropriate Zone indicator is lit to show chime zone(s) Zone n Chime selected Zone n Chime deselected How to Omit zone(s) on setting system Press number button to select / deselect Zone Chime 1 2 3 4 5 6 7 8 During the exit period after entering User code and selecting a program press Day OMIT, the exit Set the system or tone will stop and Set a Program and while the zones that are system is setting: about to be armed will be displayed. Omit ZONE(S) TO BE ARMED Key in the zone Exit beep number(s) to be omitted which will Press the zone(s) n flash to confirm to be omitted selection. Zone ZONE(S) TO BE OMITTED indicators which show steady are Set still about to be 10 seconds Exit beep armed. When the insistent beeps selection is Day complete press Set and the exit tone will start. If a zone refuses to be omitted, it may be because the engineer has programmed the panel to prevent you from turning off the zone. If in doubt ask your installer for advice. How to Quick set Reset Leave chime mode Day Fire Alarm The fire zone will operate on detection of a fire, whether the system is Set or Unset, when configured as a 24 hour zone, and cause a distinctive internal sounder tone. The external sounders will pulse on and off at 2 second intervals and zone indicator will flash to attract attention. Chime is a low security monitoring system for use when the system is Unset. When a zone that is set to chime is operated, the internal sounder will produce a low volume two stage warning tone and the Zone indicator will show. The indicator may be cancelled by pressing Reset. Chime is particularly useful in a shop to warn of a customer presence or in a house to warn that a door or particular area has been accessed. Any zone may set to be on or off chime by pressing the CHIME key and then keying in the required zone number(s). Key 0 to cancel all zones from chime. After a few seconds the system will automatically return to the Day mode. 4188-693 issue 1_8/01 4 Citadel XR1 G3 intruder system Operating instructions Operator's Program mode The information below shows the programmable options available and how to change them. Once the operator program mode has been accessed, each section may be changed in any order. As each operation is completed the system will automatically return to top level of program mode. How to view the events log The panel can hold up to 8 previous events which can be scrolled automatically or manually. The automatic scroll starts with the newest event ( number 8) to the oldest one ( number 1). Example: To view up to 8 previous events and thereafter to stop the event scroll, Press: Prog 0 1 2 3 Chime Reset Note: When programming the system should be in the Day mode, with the Day and Power indicators lit. Enter Operator's program mode Chime View the event log Tamper To exit operation at any time On pressing the Reset key you will quit the current level of operation. Reset Automatic event scroll Starting from event 1 to 8 To manually scroll View event 1 1 (oldest event) 2 3 Zone, PA and Tamper indicators will be lit to show zone in alarm. Flashing indicates the first zone in alarm. Day indicates status of panel at the time of alarm Quit the current function Leave Engineering menu Down one menu level View event 2 View event 3 View event 4 View event 5 View event 6 View event 7 How to enter Operator's program mode To enter the Operator's program mode the system should be in Day Prog mode with the Day and ZONE 1 - 8 Power indicator lit. Momentarily On 0 1 2 3 4 5 6 7 8 View event 8 (Newest event) Chime Resume automatic scroll Acknowledge Tamper Day Reset Stop event scroll / view Leave program mode Day Acknowledge Tamper Tamper 4188-693 issue 1_8/01 5 Operator's Program mode Operating instructions Citadel XR1 G3 Intruder system How to create/omit User 2 code User 1 code which is usually considered to be the Managers code has the authority to add, change or delete the user 2 code. Example: To create user 2 code 4567, Press: Prog How to change current user code You can change the current user 1 or user 2 code for security reason. Example: To change user 1 code from 0123 to 7777, Press: Prog 0 5 1 6 2 7 3 Reset 7 7 0 7 1 7 2 7 3 Reset 8 4 Enter Operator's program mode How to create/omit User 2 code Enter Operator's program mode Change / omit User code 2 7 (By user 1 only) Attack 8 Change the code of Current user (either User 1 or User 2) Attack ZONE 1-4 ZONE 1-4 n n n n n n n n New code Current user new code NOTE - The sounder will produce a flat beep if code is rejected. Rising beeps NOTE - The sounder will produce a flat beep if code is rejected. Or Omit To omit the user 2 code ZONE 1-4 NOTE - Factory default code for User 2 is not programmed Rising beeps Attack ZONE 1-4 Attack Reset Leave program mode Day Acknowledge Tamper Reset Leave program mode Day Acknowledge Tamper 6 4188-693 issue 1_8/01 Citadel XR1 G3 intruder system Operating instructions How to carry out Alarm and Walk tests The alarm test function allows you to test the Strobe, Bell, Low and High volume sounders of the system. The walk test function allows each detector to be checked in order to verify that they are functioning correctly. Example: To start bell test and thereafter to stop bell test. Prog 0 1 2 3 0 3 0 Reset Reset Enter Operator's program mode 0 Alarm test Attack Press zero to turn off options 2,3,4 and 5 before selecting a new one 2 Strobe test Strobe On Bell on Day Day 3 Bell test 4 5 6 Low volume sounder High volume sounder Walk test internal low volume sound internal high volume sound Strobe Day Day Strobe On Day x1 for zone 1 x2 for zone 2 | x4 for zone 4 flat x1 for zone 5 flat x2 for zone 6 | flat x4 for zone 8 Rapid for PA Rapid for Tamper ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.