9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your CRESTRON AV2 PRO2 : user manual, user guide, instruction manual.
Search a brand
Advanced Search

Need help using a product?
Look at the reviews on CRESTRON AV2 PRO2

User manual CRESTRON AV2 PRO2

Diplodocs help download the user guide CRESTRON AV2 PRO2 .

Download the complete user guide (1216 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide CRESTRON AV2 PRO2

Detailed instructions for use are in the User's Guide.

Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Operations Guide This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2006 Crestron Electronics, Inc. Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Contents 2-Series Integrated Dual Bus Control System: AV2 & PRO2 1 Introduction ............................................................................................................................... 1 Features and Functions ................................................................................................ 1 Specifications .............................................................................................................. 3 Physical Description.................................................................................................... 5 Industry Compliance ................................................................................................... 9 Setup ........................................................................................................................................ 10 Network Wiring......................................................................................................... 10 Identity Code ............................................................................................................. 10 Hardware Hookup ..................................................................................................... 10 Programming Software ............................................................................................................ 14 Earliest Version Software Requirements for the PC ................................................. 14 Programming with Crestron SystemBuilder.............................................................. 14 Programming with SIMPL Windows ........................................................................ 14 Example Program ...................................................................................................... 15 Uploading and Upgrading........................................................................................................ 16 Establishing Communication..................................................................................... 16 Programs and Firmware ............................................................................................ 17 Operation ................................................................................................................................. 18 Problem Solving ...................................................................................................................... 23 Possible Problems with the Control System.............................................................. 23 Serial Communication Difficulties with Other Devices Connected to the Control System ....................................................................................................................... 24 Check Network Wiring.............................................................................................. 26 Reference Documents................................................................................................ 27 Further Inquiries ........................................................................................................ 27 Future Updates .......................................................................................................... 27 Software License Agreement................................................................................................... 28 Return and Warranty Policies .................................................................................................. 30 Merchandise Returns / Repair Service ...................................................................... 30 CRESTRON Limited Warranty................................................................................. 30 Operations Guide ­ DOC. 5957B Contents · i Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System 2-Series Integrated Dual Bus Control System: AV2 & PRO2 Introduction Features and Functions · · · · · · · · · · · · 2-Series engine with Dual-bus architecture 36 MB of Internal Memory1 4 GB Compact Flash memory card slot Cresnet port ­ master/slave selectable 10/100 Ethernet capable with SSL encryption Crestron e-Control2 and Crestron RoomView enabled Built-in firewall, NAT and router Six Com ports, eight IR/serial ports, eight Versiport I/O ports, eight relay ports Three Y-Bus2 / One Z-Bus control card expansion slots Internal power supply 2-Space EIA rack-mountable Front panel control with LCD display (PRO2 only) 1. For more information on internal memory, refer to "2-Series Memory & Directory Structure" in the latest version of the Crestron 2-Series Control System Reference Guide (Doc. 6256), which is available from the Crestron website (http://www.crestron.com/manuals). 2. Optional on AV2. 2-Series Engine At the heart of the AV2 & PRO2 is the powerful 32-bit Freescale ColdFire® processor. Crestron's exclusive enhanced real-time operating system makes the AV2 & PRO2 the fastest, most reliable control systems available. Dual Bus Architecture The AV2's & PRO2's unique dual-bus architecture affords ultra fast communications. The 40 Mbps Y-Bus provides a high-speed backplane for IR, serial and other integrated control ports. Additional control ports and interfaces like MIDI and digital audio processing may be added by installing up to three Y-Bus control Operations Guide ­ DOC. 5957B 2-Series Integrated Dual Bus Control System: AV2 & PRO2 · 1 2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 cards (expansion cage option required for AV2). At a blazing 300 Mbps, the Z-Bus supports Fast Ethernet with future support for other emerging technologies. Cresnet® Cresnet is the communications backbone for many Crestron touchpanels, keypads, lighting controls and other devices. The Cresnet bus is a simple, yet flexible 4-wire network that provides rock-solid bidirectional communication and power for up to 252 Cresnet devices. Cresnet Slave Mode Selectable Cresnet Slave Mode enables the AV2 & PRO2 to be configured as Cresnet slave devices, effectively transforming them into Cresnet expansion modules. Such flexibility can offer a cost-effective solution for system expansion, providing a host of additional control ports in a single module. Ethernet Crestron pioneered the IP-based control system to harness the vast possibilities of Ethernet and the Internet for remote control, monitoring, programming and diagnostics. The AV2 & PRO2 are designed to deliver the world's most advanced IP control solutions. A choice of single or dual port Ethernet cards enables a full-duplex 10/100 Ethernet connection with built-in Web server and email client and support for both static and dynamic IP addressing. Crestron e-Control®2 Crestron's award-winning e-Control 2 XPanel solutions offer the most flexible range of IP control possibilities available. Using a Windows® computer or CE/PocketPCTM PDA device, e-Control 2 provides an amazing control GUI that looks and behaves just like a Crestron Isys® touchpanel. Crestron RoomView® Every Ethernet-enabled 2-Series control system works directly with Crestron's exclusive RoomView Help Desk software for the industry's most comprehensive facility-wide asset management solution. SSL All Ethernet-enabled 2-Series control systems support SSL (Secure Sockets Layer), the industry standard for protecting sensitive network communications. NAT The AV2's & PRO2's onboard NAT (Network Address Translator) acts as a firewall and router to facilitate the configuration of a private control LAN with a single-point connection to the client's LAN (Dual-port Ethernet card required). Memory Expansion A memory card slot accessible on the rear panel allows for easy expansion of the AV2's & PRO2's internal memory using any Type II Compact Flash memory card up to 4 GB. Note that compact flash memory supports FAT file structure. 2 · 2-Series Integrated Dual Bus Control System: AV2 & PRO2 Operations Guide ­ DOC. 5957B Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Front Panel Control (PRO2 only) The PRO2 includes a programmable front control panel with LCD display and control port status indicators. The PRO2's front panel serves as a ready user interface for system configuration and diagnostics and can also be custom programmed to enable menu-driven control capability. Specifications Specifications for the AV2 & PRO2 are listed in the following table. AV2 & PRO2 Specifications SPECIFICATION Processor CPU Processing Speed Memory SDRAM NVRAM Flash Compact Flash Operating System 32 MB 256 kB 4 MB DETAILS 32-bit Freescale Coldfire Microprocessor 257 MIPS (Dhrystone 2.1 benchmark) expandable up to 4 GB (not included) Real-time preemptive multithreaded/multitasking kernel; FAT32 file system with long names; supports SIMPL Windows and SIMPL+ 10/100BaseT, auto-negotiating, full/half duplex, static IP or DHCP/DNS, SSL, TCP/IP, UDP/IP, CIP, SMTP, built-in Web server and e-mail client; supports Crestron e-Control2 Xpanel and RoomView applications All above features plus: built-in firewall, router and network address translator (NAT) (3) (AV2 requires CAGE2 accessory, sold separately); Accept all Y-Bus control cards (1) Accepts all Z-Bus control cards 2.3 Amps, 100-250 Volts AC, 50/60 Hz 50 Watts (shared with control card expansion slots) 4A, 250V (1 ¼" x ¼" Slow Blow Fuse Series) 50 watts (DC) available for Cresnet devices 41º to 113ºF (5º to 45ºC) 10% to 90% RH (non-condensing) Ethernet With C2ENET-1 With C2ENET-2 Expansion Slots Y-Bus1 Z-Bus2 Power Requirements Internal Universal Power Supply Available Cresnet Power Network Power Fuse Rating Environmental Temperature Humidity (Continued on following page) Operations Guide ­ DOC. 5957B 2-Series Integrated Dual Bus Control System: AV2 & PRO2 · 3 2-Series Integrated Dual Bus Control System AV2 & PRO2 Specifications (Continued) Crestron AV2 & PRO2 SPECIFICATION Enclosure Dimensions Height Width Depth Weight AV2 PRO2 Available Accessories CAGE2 (AV2 only) C2ENET-1 C2ENET-2 C2COM-2 C2COM-3 C2IR-8 CNXIO-16 CNXAO-8 CNXRY-8 CNXRY-16 CNXMIDI C2VEQ-4 CNXTA C2N-HBLOCK C2N-NPA8 C2N-SPWS300 CNSP-XX IRP2 DETAILS Black metal, 2U 19" rack-mountable (rack ears included) 3.47 in (8.82 cm) 19.00 in (48.26 cm) with ears; 17.03 in (43.25 cm) without ears 9.69 in (24.61 cm) 7.1 lbs (3.22 kg) ­ with line cord 8.0 lbs (3.63 kg) ­ with line cord 3-Card expansion cage Single port Ethernet card Dual port Ethernet card Dual COM port card3 Three COM port card3 8 IR/Serial output card3 16 I/O Versiport card3 8 Analog output card3 8 Relay card3 16 Relay card3 MIDI Interface card3 4-Channel Volume/EQ and 4x4 matrix mixer card3 Telephone interface and Voice/WAV sound card3 Cresnet Network Distribution Block Cresnet Network Poll Accelerator 300 Watt Cresnet Power Supply Custom Serial Interface Cable IR Probe 1. 40 Mb/s parallel communications; Internal backplane for integrated control ports and Y-Bus expansion slots. 2. 300 Mb/s parallel communications; Backplane for Z-Bus expansion slots. 3. AV2 requires CAGE2 for card installation. 4 · 2-Series Integrated Dual Bus Control System: AV2 & PRO2 Operations Guide ­ DOC. 5957B Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Physical Description This section provides information on the connections, controls and indicators available on your AV2 & PRO2. AV2 Physical View (shown with accessory cards installed in CAGE2; optional) PRO2 Physical View (shown with accessory cards installed) Operations Guide ­ DOC. 5957B 2-Series Integrated Dual Bus Control System: AV2 & PRO2 · 5 2-Series Integrated Dual Bus Control System AV2 & PRO2 Overall Dimensions Crestron AV2 & PRO2 1 2 3 4 5 6 7 8 9 10 11 12 9.69 in (24.61 cm) 17.03 in (43.25 cm) 1 13 3.47 in (8.82 cm) 14 15 16 17 18 19 6 · 2-Series Integrated Dual Bus Control System: AV2 & PRO2 Operations Guide ­ DOC. 5957B Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Connectors, Controls & Indicators # 1 CONNECTORS1, CONTROLS & INDICATORS COMPUTER DESCRIPTION DB9F connectors (one on front panel and one on rear) are used when programming with a PC. Each port is modem compatible. (Modem and PC cables not included.) FRONT PANEL REAR PANEL 2 3 4 PWR LED NET LED MSG LED 2 Indicates 24 Volts DC power supplied from Cresnet control network. Indicates communication with Cresnet System. Illuminates when a message is detected. To decipher content, examine the message available from the menu function buttons or through th ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.