Detailed instructions for use are in the User's Guide.
The Da-Lite Difference.
Instruction Book for
DA-LITE SCREEN COMPANY, INC.
3100 North Detroit Street Post Office Box 137 Warsaw, Indiana 46581-0137 Phone: 574-267-8101 800-622-3737 Fax: 574-267-7804 Toll Free Fax: 877-325-4832 www.da-lite.com e-mail: info@da-lite.com
CosmopolItan® ElECtrol®
For sizes Up to 9'x12'
IMPORTANT SAFETY INSTRUCTIONS
When using your video equipment, basic safety precautions should always be followed, including the following: 1. Read and understand all instructions before using. 2. Position the cord so that it will not be tripped over, pulled, or contact hot surfaces. 3. If an extension cord is necessary, a cord with a current rating at least equal to that of the appliance should be used. Cords rated for less amperage than the appliance may overheat. 4. To reduce the risk of electric shock, do not disassemble this appliance. Contact an authorized service dealer when repair work is required. Incorrect reassembly can cause electric shock when the appliance is used subsequently. 5. The use of an accessory attachment not recommended by the manufacturer may cause a risk of fire, electric shock, or injury to persons.
SAVE THESE INSTRUCTIONS
PRE-INSTALLATION
1. Carefully unpack screen and remove outer wrapping from case. 2. Do not remove black tape or rubber bands from slat pocket. 3. Always handle screen in horizontal position.
INSTALLATION
There are three methods of mounting to include: Flush against wall; Suspended from ceiling (use extension brackets); and Recessed above ceiling.
USE NO. 6 BRACKETS TO HANG BEHIND BEAM OR VALANCE
CEILING HANGING WALL MOUNTED
CONCEALED (ALLOW ROOM FOR ACCESS)
PICTURE SURFACE
PICTURE SURFACE
PICTURE SURFACE
PICTURE SURFACE
FIGURE 1
NOTE: Under no circumstances should unit be completely sealed in recessed installation. Allow access for service. Picture surface is centered in case. Case extends 4" beyond surface on either end. Do not attach anything to screen slat rod or bottom fabric pocket.
! s
1. Make sure screen is level. Use a carpenter's level and plumb level. CAUTION! Do not cut wrapping paper or tape with knife or any sharp tool. Remove by hand.
2. Remove tape and rubber bands from slat pocket. 3. Install electrical hook up that applies to your unit. Make sure to review your Electrical Installation Checklists and wiring diagrams (included) for either 120 volt switch, 220/240 volt switch, or low voltage control. 4. Test installation by running screen up and down a few times. Be prepared to stop screen. Standard Duty Cycle: 1 MIN. ON / 3 MIN. OFF .
NOTE: Must be installed in accordance with the requirements of the Local Building Codes, the Canadian Electrical Code (CEC), CAN/ CSA C22.1 and the National Electric Code (NEC), NFPA 70.
1
COSMOPOLITAN® ELECTROL® INSTALLATION
3/4" DIAMETER HOLE FOR WALL INSTALLATION MOTOR END Overall length A=fabric width + 8". Length B is the distance between wall mounting holes at back of end caps and is the fabric width + 6-1/2".
A B 4"
FABRIC HEIGHT x WIDTH AS ORDERED, UP TO 12 FEET x 12 FEET.
4"
FIGURE 2
423/32"
5
/32"
129/32" /8" DIAMETER FOR CEILING INSTALLATION
3
63/32" 57/8"
ENCLOSURE COVER
1 /16"
3
/8" DIAMETER KNOCK OUT
7 7 /8" DIAMETER OPENING FOR ELECTRICAL FITTINGS
PICTURE SURFACE
2
COSMOPOLITAN® ELECTROL® INSTALLATION
WIRING ENCLOSURE COVER
120V WIRING DIAGRAM
TO JUNCTION BOX, MOUNTED IN SCREEN CASE, IN WHICH INTERNAL WIRING TERMINATES IN WHITE, BLACK AND RED LEADS
DOWN BLACK UP RED COMMON WHITE
DOWN WHITE LIMIT SWITCH ADJUSTMENT
BLACK ROCKER SWITCH UP OFF DOWN
WHITE RED BLACK WITH YELLOW
SIDE VIEW OF SWITCH AND BOX
OPERATING SWITCH AND PLATE FURNISHED WITH SCREEN. (SPDT WITH CENTER OFF)
IN MULTIPLE CONTROL INSTALLATIONS THIS SWITCH IS REPLACED BY THE LOW VOLTAGE CONTROL, OPERATED FROM PUSH BUTTON STATIONS.
AC COMMON AC HOT 120 V. 60 HZ. 2.5 MAX. AMP
NOTE: A single switch cannot be used to operate more than one screen. Contact the factory for further information.
THIS SWITCH CANNOT BE USED WITH LVC.
FIGURE 3
240 VOLT WIRING DIAGRAM FOR STANDARD WALL SWITCH: Da-Lite offers two styles of 240 volt wall switches for standard operation. Please see wiring diagram included in wall switch box included with screen.
UP
RJ-22 JACK
STO
P
UP DO (RE W CO N D) (B (W MM LA HIT ON CK ) E)
120V WIRING DIAGRAM WITH OPTIONAL BUILT-IN VIDEO PROJECTOR INTERFACE
CAUTION: THE PROJECTOR MUST BE TURNED OFF BEFORE CONNECTING THE TRIGGER WIRES TO THE PROJECTOR. FAILURE TO DO SO MAY DAMAGE THE CONTROLLER. Use 2-conductor 20-24 gauge wire to extend the low voltage connection from the projector's 5 or 12-volt screen trigger output to the length required to reach the VPI. When extending the low voltage connection from the projector's screen trigger output polarity does not matter. The red and black wires from the VPI are interchangeable.
LED UP LIMIT TACTILE BUTTON RJ-22 INPUTS
RJ-22 JACK RJ-22 OUTPUT DRY CONTACTS
DOW
N
DOWN LIMIT TACTILE BUTTON BACK OF WALL SWITCH
RJ-45 JACK RJ-45 RECEPTACLE
DATA CABLE
FRONT OF WALL SWITCH
POWER WIRE BLACK RED
IMPORTANT NOTE: The wall switch is REQUIRED to make any limit switch adjustments, EVEN if a third party control system is used. Therefore, it is advised to wire the switch or provide a 3-conductor connection that is accessible.
5/12 VOLT SCREEN TRIGGER ON PROJECTOR
VPI TRIGGER MODULE BLACK (HOT) WHITE (COMMON)
GREEN (GROUND) GROUNDÂMUST BE CONNECTED TO BUILDING GROUND
POWER INPUT 120VAC / 60HZ
FIGURE 4
3
COSMOPOLITAN® ELECTROL® INSTALLATION
120V WIRING DIAGRAM WITH OPTIONAL BUILT-IN LOW VOLTAGE CONTROL
LED RJ-22 JACK RJ-22 OUTPUT
UP DO (RED WN ) (BL M AC (W HIT K) E)
RJ-14 PIN-OUTS
(TAB IS FACING UP)
WHITE GREEN RED BLACK BUS (RP DATA) RQ DATA +5V GND
RJ-22 PIN-OUTS
(TAB IS FACING UP)
+12V BUS (RP DATA) RQ DATA +5V GND RQ CLOCK BLUE YELLOW GREEN RED BLACK WHITE
Supplied RJ-14 cable
Standard RJ-22 can be used in place of RJ-14
UP LIMIT TACTILE BUTTON RJ-22 JACK
RJ-22 INPUTS
RJ-45 PIN-OUTS
DRY CONTACTS (TAB IS FACING UP)
MANUAL 2 +12V BUS (RP DATA) RQ DATA +5V GND BROWN BLUE YELLOW GREEN RED BLACK ORANGE PURPLE
CO
UP
STO
P
DOW
N
DOWN LIMIT TACTILE BUTTON
RJ-45 JACK RJ-45 RECEPTACLE
RQ CLOCK
DATA CABLE
MANUAL 1
FRONT OF WALL SWITCH
BACK OF WALL SWITCH
POWER WIRE
IMPORTANT NOTE: The wall switch is REQUIRED to make any limit switch adjustments, EVEN if a third party control system is used. Therefore, it is advised to wire the switch or provide a 3-conductor connection that is accessible.
GREEN (GROUND) BLACK (HOT) WHITE (COMMON)
POWER INPUT 120VAC / 60HZ
GROUNDÂMUST BE CONNECTED TO BUILDING GROUND
FIGURE 5
240V WIRING DIAGRAM WITH OPTIONAL BUILT-IN LOW VOLTAGE CONTROL
BLUE (COMMON) BROWN (HOT)
OPTIONAL IR AND RF REMOTE CONTROL
CONNECT SUPPLIED RJ9 CABLE TO SPLITTER AND SWITCH, OR USE 4 CABLE CONDUCTOR TO CONNECT TO SCREW TERMINALS.
LOW-VOLTAGE WALL SWITCH
UP DN UP
GND +5V
240VAC 50HZ
MOTOR
RJ9
RJ9
STOP
GREEN
DOWN 3-POSITION SWITCH RJ9
GROUND TO CASE
UP +5V COM DN
GROUNDÂMUST BE CONNECTED TO BUILDING GROUND
GREEN FRONT BACK
SPLITTER DRY CONTACTS
ILT RJ9 PIN-OUTS
(TAB IS FACING UP)
IR or UP GND COMMON +5V DN or DATA
BLACK RED GREEN WHITE
IMPORTANT NOTE: The wall switch is REQUIRED to make any limit switch adjustments, EVEN if a third party control system is used. Therefore, it is advised to wire the switch or provide a 4-conductor connection that is accessible.
FIGURE 6
4
SCREEN ADJUSTMENT FOR SCREENS WITHOUT A BUILT-IN LOW VOLTAGE CONTROL
Surface travel is stopped automatically in the fully opened and closed positions by limit switches that are properly adjusted at DA-LITE. Should it be necessary to adjust for more or less picture drop (viewing area), proceed in the following manner: NOTE: Use a screwdriver or 5/32" Allen wrench to make adjustments. SETTING THE DOWN LIMIT POSITION TO REDUCE SCREEN DROP: Turn the white limit switch screw (Figure 3) clockwise to decrease the amount of screen drop. Run the screen down to test the stop position. If the screen drops too far, raise the screen about one foot and adjust the limit switch again. Repeat until the desired position is set. TO INCREASE SCREEN DROP: Turn the white limit switch screw counterclockwise to increase the amount of screen drop. Run the screen down to test the stop position. If the screen does not drop enough, raise the screen about one foot and adjust the limit switch again. Repeat until the desired position is set. Do not adjust for more drop than what was ordered. At least 1-1/2 wraps of fabric must remain on the roller. CAUTION: Do not adjust for more drop than what was ordered. At least 1-1/2 wraps of fabric must remain on the roller. This screen comes standard with 0" or 2" black at the top. See the specification data sheet for details.
! s
SCREEN ADJUSTMENT FOR 120V SCREENS WITH A BUILT-IN LOW VOLTAGE CONTROL OR VPI
1. Locate the wall switch and remove the cover plate from the 3-button wall switch and remove the switch from the junction box. 2. Locate the two tactile buttons on the back of the switch. They are square silver with black round buttons. See Figure 4 (VPI) or Figure 5 (LVC) for diagram. 3. To adjust the down limit switch, press and hold the down tactile button until the LED on back of switch turns solid red. This will put the motor in limit set mode. Turn the wall switch over and use the down button on front of switch. Press and hold until the desired travel position is reached. If you travel to far down you can press the up to move the screen upward. If you press and let go of either up or down button the motor will do a small jog in that direction for finer adjustment of screen. Once desired position is reached turn switch over press and hold down tactile button until the LED on back of switch blinks red twice. The down limit is now set. 4. To adjust the up limit switch, press and hold the up tactile button until the LED on back of switch turns solid green. This will put the motor in limit set mode. Turn the wall switch over and use the up button on front of switch. Press and hold until the desired travel position is reached. If you travel to far up you can press the down to move the screen downward. If you press and let go of either up or down button the motor will do a small jog in that direction for finer adjustment of screen. Once desired position is reached turn switch over press and hold up tactile button until the LED on back of switch blinks green twice. The up limit is now set. 5. To test limit switch setting, press and release the up or down button on the wall switch to operate the screen. 6. Replace switch and cover plate on the wall. IMPORTANT NOTE: The wall switch is REQUIRED to make any limit switch adjustments, EVEN if a third party control system is used. Therefore, it is advised to wire the switch or provide a 3-conductor connection that is accessible.
SCREEN ADJUSTMENT FOR 220V/240V SCREENS WITH A BUILT-IN LOW VOLTAGE CONTROL
1. Remove the cover plate from the 3-button wall switch and remove the switch from the junction box. 2. Locate small 3-position switch on back of wall switch. (See Figure 6) 3. To adjust the down limit switch, slide the 3-position switch to the down position. Press and hold the down button to run the screen down to the desired stop position. Release the button to stop the screen. DO NOT PUSH THE STOP BUTTON. 4. When the screen is in the desired down position, slide the 3-position switch to the off (center) position. The down limit switch is now set. 5. To adjust the up limit switch, slide the 3-position switch to the up position. Press and hold the up button to run the screen up to the desired stop position. Release the button to stop the screen. DO NOT PUSH THE STOP BUTTON. 6. When the screen is in the desired up position, slide the 3-position switch to the off (center) position. The up limit switch is now set. 7 To test limit switch setting, make sure the 3-position switch is in the off (center) position. Press and release the up . or down button on the wall switch to operate the screen. 8. Replace switch and cover plate on the wall. NOTE: If stop button is pressed, the wall switch will reverse direction. To correct this, press the stop button again. This will reset the switch. You will have to re-set both the up and the down settings. IMPORTANT NOTE: The wall switch is REQUIRED to make any limit switch adjustments, EVEN if a third party control system is used. Therefore, it is advised to wire the switch or provide a 4-conductor connection that is accessible.
5
TROUBLESHOOTING
SYMPTOM 1. Screen will not operate. Motor does not hum. CAUSE (a) Incorrect line voltage. (b) Blown fuse. (c) Tripped circuit breaker. (d) No power to operating switch or junction. SOLUTION (a) Verify 115-125V (or 220-240V). If insufficient voltage, rewire incoming electric line. (b) Replace fuse. (c) Reset circuit breaker. (d) Check above. Tighten all loose wire connections. Correct any improper connections. "Down" Position Chec ...