User manual DAIKIN EKHBX007A

Diplodocs help download the user guide DAIKIN EKHBX007A.

Download the user manual DAIKIN EKHBX007A  
Download the complete
user guide (1141 Ko)
Need help, support, reviews, tips or troubleshooting for your DAIKIN EKHBX007A products ?



Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
User guide DAIKIN EKHBX007A

Detailed instructions for use are in the User's Guide.

EEDE06-9 technical data Altherma ERYQ005-007A EKHBH007A / EKHBX007A EKSWW150-300 Altherma ERYQ005-007A EKHBH007A / EKHBX007A EKSWW150-300 " The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, In the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.." ISO14001 assures an effective environmental management system in order to help protect human health and the environment from potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment. Daikin units comply with the European regulations that guarantee the safety of the product. Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. Zandvoordestraat 300 B - 8400 Ostend Belgium www.daikineurope.com EEDE0 6 - 9 EEDE06-9 - 07/2006 Printed in Belgium by Goekint Graphics EEDE06-9 technical data Altherma ERYQ005-007A EKHBH007A / EKHBX007A EKSWW150-300 · Chillers · R-410A · ALTHERMA erA el0 hl1 t4i l-h RAC Cooling only Heating only Heat pump 4 · Altherma · Chillers · Outdoor units · R-410A · ERYQ TABLE OF CONTENTS ERYQ 1 2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Nominal Capacity and Nominal Input ............................... 7 7 9 ....................................................................... 7 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 4 Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cooling/Heating capacity tables 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Dimensional drawing & centre of gravity . . . . . . . . . . . . . . . . . . . . . . . 11 Dimensional drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 12 5 6 Piping diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Wiring diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . External connection diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 15 7 8 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Sound pressure spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 18 Operation range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . · Altherma · Outdoor units 5 · Outdoor units · R-410A · ERYQ 1 i n u a r m o rA o e0 dh1Q t4Y ulR- EAO· R Features Cost effective alternative to a fossil fuel boiler Low energy bills and low CO2 emissions · · Easy to install Total solution for year round comfort 1 1 · 6 · Altherma · Outdoor units · Outdoor units · R-410A · ERYQ 2 Specifications EKHBH* ERYQ005A ERYQ006A ERYQ007A ERYQ005A EKHBX* ERYQ006A ERYQ007A 2-1 NOMINAL CAPACITY AND NOMINAL INPUT Indoor Units Condition 1 Heating capacity Cooling capacity Heating PI Cooling PI COP EER Condition 2 Heating Minimum Nominal Minimum Nominal Nominal Nominal Nominal Nominal Minimum Nominal Cooling Minimum Nominal Heating PI Cooling PI COP EER Notes Nominal Nominal Nominal Nominal kW kW kW kW kW kW kW kW kW kW kW kW - EKHBH007A* 4.36 5.75 7.45 1.26 4.56 3.87 5.03 6.68 1.58 3.18 - EKHBH007A* 4.36 6.84 8.79 1.58 4.34 3.87 6.10 7.98 1.95 3.13 - EKHBH007A* 4.36 8.43 9.58 2.08 4.05 3.87 7.64 8.76 2.54 3.00 - EKHBX007A* 4.36 5.75 7.45 3.67 5.12 5.12 1.26 2.16 4.56 2.37 3.87 5.03 6.68 4.82 7.20 7.20 1.58 2.16 3.18 3.33 EKHBX007A* 4.36 6.84 8.79 3.67 5.86 6.13 1.58 2.59 4.34 2.26 3.87 6.10 7.98 4.82 8.16 8.50 1.95 2.59 3.13 3.15 EKHBX007A* 4.36 8.43 9.58 3.67 6.08 7.10 2.08 2.75 4.05 2.21 3.87 7.64 8.76 4.82 8.37 8.91 2.54 2.75 3.00 3.04 1 2 Maximum kW Maximum kW Maximum kW Maximum kW *Condition 1 - cooling Ta 35°C - LWE 7°C - heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) * Condition 2 - cooling Ta 35°C - LWE 18°C (DT = 5°C) - heating Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) ERYQ005A (+ EKHBH) ERYQ006A (+ EKHBH) ERYQ007A (+ EKHBH) ERYQ005A (+ EKHBX) ERYQ006A (+ EKHBX) ERYQ007A (+ EKHBX) 2-2 Casing TECHNICAL SPECIFICATIONS Colour Material Unit Height Width Depth Packing Height Width Depth mm mm mm mm mm mm kg kg Ivory white Polyester painted galvanised steel 797 960 390 735 825 300 56 61 EPS Carton kg Length Nr of Rows Fin Pitch mm Nr of Stages mm 5 845 2 1.8 32 Hi-Xa(8) Type Treatment WF fin Anti-corrosion treatment (PE) Propeller 1 Quantity Output W 1 53 1 Model Type Motor Output W 2YC63BXD#C Hermetically sealed swing compressor 1920 Dimensions Weight Packing Unit Packed Unit Material Weight Heat Exchanger Dimensions Tube type Fin Fan Type Quantity Motor Compressor Quantity Motor · Altherma · Outdoor units 7 · Outdoor units · R-410A · ERYQ 2 2-2 Specifications TECHNICAL SPECIFICATIONS Heating Cooling Sanitary water Min Max Min Max Min Max Sound Power Sound Pressure Cooling Sound Power Sound Pressure °CWB °CWB °CDB °CDB °CDB °CDB dBA dBA dBA dBA R-410A kg 1.7 Expansion valve(electronic type) 1 FVC50K l Type Diameter (OD) Gas Type Diameter (OD) Drain Quantity Type Diameter (OD) Piping Length Minimum mm m kg/m mm mm 0.75 Flare connection 6,35 Flare connection 15,9 1 Socket 18 3 30 0.02 IF > 10m 15 64 48 64 48 66 52 -20 43 64 48 63 47 64 48 64 47 66 52 66 53 ERYQ005A (+ EKHBH) ERYQ006A (+ EKHBH) ERYQ007A (+ EKHBH) ERYQ005A (+ EKHBX) ERYQ006A (+ EKHBX) ERYQ007A (+ EKHBX) 1 2 Operation Range -20 25 7 20 Sound Level (nominal) Heating Refrigerant Type Charge Control Nr of Circuits Refrigerant Oil Piping connections Type Charged Volume Liquid (OD) Maximum m Additional Refrigerant Charge Installation height difference Maximum m Max. internunit level difference Defrost Method Defrost Control Capacity Control Method Standard Accessories Item Quantity Item Quantity m 20 Reverse cycle Sensor for outdoor heat exchanger temperature Inverter controlled Installation manual 1 Drain plug 1 8 · Altherma · Outdoor units · Outdoor units · R-410A · ERYQ 2 2-3 Specifications ELECTRICAL SPECIFICATIONS Name Phase Frequency Voltage Voltage range Hz V Maximum V Cooling Heating Cooling Heating A A A A A 18 20 3 4 Included earth wiring 11 16.25 ERYQ005A (+ EKHBH) ERYQ006A (+ EKHBH) ERYQ007A (+ EKHBH) ERYQ005A (+ EKHBX) ERYQ006A (+ EKHBX) ERYQ007A (+ EKHBX) Power Supply V1 1~ 50 220-440 +10% 11 1 2 Current Starting Current Maximum running Current Recomended fuses Wiring connections For Power Supply Quantity For connection Quantity with indoor Remark · Altherma · Outdoor units 9 · Outdoor units · R-410A · ERYQ 3 3-1 COOLING Capacity tables Cooling/Heating capacity tables Tamb (°C) LWE (°C) 7 11 13 16 20 7 11 13 16 20 7 11 13 16 20 LWC Tamb -15 -10 -7 -2 2 7 -15 -10 -7 -2 2 7 -15 -10 -7 -2 2 7 LWC Tamb -15 -10 -7 -2 2 7 -15 -10 -7 -2 2 7 -15 -10 -7 -2 2 7 20 CC 6.01 6.81 7.23 7.88 8.80 7.15 8.09 8.57 9.33 10.4 8.24 9.26 9.79 10.6 11.7 30 HC 3.93 4.65 5.14 6.06 6.89 8.03 4.87 5.67 6.21 7.23 8.14 9.40 5.42 6.27 6.84 7.92 8.9 10.2 30 HC 3.50 4.14 4.52 5.27 5.92 8.03 4.34 5.04 5.46 6.29 7.00 9.40 4.82 5.58 6.02 6.89 7.6 10.2 PI 1.40 1.45 1.45 1.46 1.45 1.57 1.73 1.79 1.80 1.81 1.81 1.98 1.96 2.03 2.04 2.07 2.08 2.28 HC 3.27 3.85 4.20 4.89 5.49 7.45 4.11 4.75 5.13 5.89 6.55 8.79 4.59 5.28 5.69 6.48 7.18 9.58 PI 1.48 1.52 1.54 1.57 1.57 1.57 1.82 1.88 1.91 1.95 1.97 1.98 2.06 2.13 2.17 2.22 2.26 2.28 HC 3.67 4.32 4.77 5.62 6.38 7.45 4.62 5.34 5.83 6.77 7.61 8.79 5.16 5.93 6.46 7.45 8.35 9.58 35 PI 1.51 1.56 1.58 1.60 1.60 1.75 1.85 1.92 1.94 1.98 1.99 2.19 2.08 2.17 2.20 2.25 2.27 2.51 HC 3.09 3.62 3.95 4.59 5.16 7.00 3.94 4.53 4.88 5.59 6.20 8.32 4.43 5.06 5.43 6.17 6.82 9.10 PI 1.56 1.57 1.57 1.56 1.55 2.05 2.09 2.11 2.13 2.16 2.43 2.49 2.52 2.57 2.63 CC 5.73 6.50 6.90 7.54 8.42 6.84 7.73 8.20 8.92 9.9 7.90 8.87 9.38 10.17 11.3 35 PI 1.59 1.65 1.68 1.72 1.74 1.75 1.94 2.02 2.07 2.13 2.16 2.19 2.19 2.29 2.34 2.41 2.46 2.51 HC 3.47 4.07 4.49 5.28 6.00 7.00 4.43 5.09 5.55 6.42 7.21 8.32 4.97 5.68 6.17 7.10 7.93 9.10 40 PI 1.62 1.70 1.72 1.75 1.76 1.94 1.98 2.07 2.10 2.15 2.18 2.42 2.23 2.34 2.37 2.44 2.47 2.76 HC 2.97 3.46 3.77 4.38 4.92 6.68 3.83 4.38 4.71 5.37 5.96 7.98 4.32 4.91 5.26 5.96 6.58 8.76 25 PI 1.75 1.77 1.78 1.78 1.79 2.28 2.34 2.36 2.40 2.44 2.68 2.76 2.80 2.86 2.94 CC 5.43 6.17 6.56 7.17 8.03 6.50 7.34 7.79 8.49 9.48 7.52 8.45 8.93 9.69 10.75 40 PI 1.71 1.79 1.83 1.88 1.91 1.94 2.08 2.18 2.24 2.32 2.37 2.42 2.34 2.46 2.53 2.62 2.69 2.76 HC 3.33 3.89 4.28 5.03 5.72 6.68 4.30 4.92 5.35 6.17 6.92 7.98 4.86 5.51 5.97 6.85 7.65 8.76 45 PI 1.75 1.84 1.87 1.92 1.94 2.15 2.12 2.24 2.28 2.35 2.38 2.66 2.39 2.52 2.57 2.65 2.70 3.02 HC 2.89 3.36 3.65 4.24 4.76 6.47 3.77 4.29 4.60 5.23 5.80 7.78 4.27 4.82 5.15 5.83 6.43 8.56 30 PI 1.95 1.98 2.00 2.01 2.03 2.52 2.59 2.63 2.68 2.73 2.94 3.05 3.10 3.17 3.26 CC 5.12 5.83 6.20 6.79 7.63 6.13 6.94 7.36 8.03 8.99 7.10 7.79 8.14 8.68 9.39 45 PI 1.84 1.94 1.99 2.06 2.11 2.15 2.23 2.36 2.42 2.52 2.59 2.66 2.51 2.65 2.73 2.85 2.93 3.02 HC 3.25 3.78 4.15 4.87 5.53 6.47 4.24 4.82 5.23 6.02 6.74 7.78 4.80 5.42 5.86 6.70 7.47 8.56 50 PI 1.89 2.00 2.03 2.10 2.13 2.37 2.28 2.42 2.47 2.56 2.61 2.92 2.56 2.72 2.78 2.88 2.94 3.31 35 PI 2.16 2.21 2.23 2.26 2.29 2.77 2.87 2.91 2.97 3.04 3.23 3.31 3.36 3.41 3.48 CC 4.80 5.30 5.56 5.95 6.48 5.35 5.84 6.09 6.46 6.96 5.68 6.12 6.34 6.67 7.09 50 PI 1.99 2.10 2.16 2.25 2.31 2.37 2.40 2.55 2.63 2.75 2.83 2.92 2.70 2.86 2.95 3.10 3.20 3.31 * The integrated heating capacity and power input, is the average heating capacity and power input during 1 cycle. (from end of defrost till end of the next defrost). 1 3 Model 40 PI 2.39 2.32 2.28 2.22 2.13 2.68 2.62 2.59 2.53 2.44 2.86 2.80 2.77 2.71 2.61 CC 4.59 4.98 5.18 5.46 5.82 4.89 5.21 5.36 5.57 5.82 4.87 5.18 5.33 5.55 5.80 43 PI 2.53 2.38 2.30 2.18 1.99 2.59 2.43 2.34 2.20 1.99 2.59 2.43 2.35 2.20 1.99 005 006 007 HEATING (Peak values) Model 005 006 007 HEATING (integrated values*) Model 005 006 007 4TW56712-1A SYMBOLS CC HC PI LWE LWC Tamb : Cooling capacity at maximum operating frequency, measured acc. Eurovent 6/C/003-2006 (kW) : Heating capacity at maximum operating frequency, measured acc. Eurovent 6/C/003-2006 (kW) : Power input (kW) : Leaving Water Evaporator temperature (°C) : Leaving Water Condensor temperature (°C) : Ambient temperature (°C) RH=85% 1 NOTES Cooling capacity Capacity is according to Eurovent rating standard 6/C/003-2006 and valid for chilled water range Dt = 38°C Heating capacity Capacity is according to Eurovent rating standard 6/C/003-2006 and valid for chilled water range Dt = 38°C Power input Power input is total input according to Eurovent rating standard 6/C/003-2006 2 3 10 · Altherma · Outdoor units · Outdoor units · R-410A · ERYQ 4 4-1 ERYQ Dimensional drawing & centre of gravity Dimensional drawing unit (mm) 1 4 Drain outlet (I.D. J 15.9 hose for connection) Minimum space for air passage Wall height on air outlet side = less than 1200 In case of removing stop valve cover 4 x holes for anchor bolts (M8 or M10) Name plate Brand name label Wiring inlet Terminal strip with earth terminal Outdoor air thermistor Liquid stop valve (J6.4 CuT) Service port Gas stop valve (J15.9 CuT) 3D051658B · Altherma · Outdoor units 11 · Outdoor units · R-410A · ERYQ 4 4-2 ERYQ Dimensional drawing & centre of gravity Centre of gravity 1 4 The position of foundation bolt 4D042258G 12 · Altherma · Outdoor units · Outdoor units · R-410A · ERYQ 5 Piping diagram ERYQ Outdoor unit Heat exchanger 1 Outdoor temperature thermistor 5 Capillary tube 1 Muffler with filter Refrigerant flow Cooling Heating Capillary tube 4 Heat exchanger thermistor Capillary tube 2 Capillary tube 3 Filter Motor operated valve Filter Propeller fan Four way valve on : heating Muffler with filter Muffler Liquid stop valve Muffler Field piping Field piping Discharge pipe thermistor Accumulator Gas stop valve with service port Compressor 3D052750A · Altherma · Outdoor units 13 · Outdoor units · R-410A · ERYQ 6 6-1 ERYQ Wiring diagram Wiring diagram 1 6 Power supply To indoor unit Sheet metal Indoor g Field wiring (discharge) (outdoor) (Condenser) Outdoor Z1CZ7C X1M, X2M Y1E V2, V3, V5, V9, V100 SA2 FU1, FU2, FU3: AC1, AC2 U, V, W, X11A, X12A E1, E2 HR1, HR2 : Ferrite core : Terminal strip : Electronic expansion valve coil : Varistor : Surge arrester : Fuse MRM10, MRM20 MRC/W R1TR3T S2S102 LEDA L N SW1 SW4 M1C M1F L1R : Magnetic relay : Thermistor : Connector : Pilot lamp : Live : Neutral : Forced operation on/off switch SW (SW1) : Local setting SW (SW4) : Compressor motor : Fan motor : Reactor Q1L PM1 PCB1,2 Y1R Sheet metal : Overload protector : Power module : Printed circuit board : Reversing solenoide valve coil : Terminal strip fixed plate : Connector 3D052296B 14 · Altherma · Outdoor units · Outdoor units · R-410A · ERYQ 6 6-2 EKHB-A Wiring diagram External connection diagram Standard parts Power supply Outdoor unit Unit power supply: 230V + earth Backup heater power supply (3/6/9kW): 400V or 230V + earth 3 core X1M:L-N-Earth 1 For more details please check unit wiring diagram 6 Optional power supply Booster heater power supply (3kW): 400V or 230V + earth X2M:1-2-3-Earth 4 core 3 or 4 core 3 core Optional parts Field supply X1M:9-10-11-Earth Sanitary tank Room thermostat Power supply booster heater 4 core 5 core X1M:7-8-Earth A3P (optional) Q2L - Clixon booster heater 230V or 400V NO valve: NC valve: 2 core 2 way valve M2S (EKHBX Units) for cooling mode R5T - Thermistor water temperature 2 core Signal Thermistor cable Note: min. distance to power cable = 3cm 2 core 3 way valve M3S (when EKSWW is installed) selection sanitary-floorheating Indoor unit User interface 3TW56719-6 · Altherma · Outdoor units 15 · Outdoor units · R-410A · ERYQ 7 7-1 Sound data Sound pressure spectrum ERYQ006ABV3 Cooling Sound pressure level (dB) Octave band center frequency (Hz) 7 Sound pressure level (dB) 1 ERYQ005ABV3 Cooling 3TW56717-1 NOTES 1 2 3 4 3TW56717-1 NOTES 1 Octave band center frequency (Hz) Data is valid at free field condition (measured in a semi-anachoic room) dB(A) = A-weighted sound power level (A-scale according to IEC) Reference acoustic pressure 0dB = 20Pa If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Coil Microphone 2 3 4 Data is valid at free field condition (measured in a semi-anachoic room) dB(A) = A-weighted sound power level (A-scale according to IEC) Reference acoustic pressure 0dB = 20Pa If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Coil Microphone Location of microphone Location of microphone ERYQ007ABV3 Cooling Sound pressure level (dB) Sound pressure level (dB) Octave band center frequency (Hz) ERYQ005ABV3 Heating 3TW56717-1 NOTES 1 2 3 4 3TW56717-2 NOTES Octave band center frequency (Hz) Data is valid at free field condition (measured in a semi-anachoic room) dB(A) = A-weighted sound power level (A-scale according to IEC) Reference acoustic pressure 0dB = 20Pa If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Coil Microphone 1 2 3 4 Location of microphone Data is valid at free field condition (measured in a semi-anachoic room) dB(A) = A-weighted sound power level (A-scale according to IEC) Reference acoustic pressure 0dB = 20Pa If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Coil Microphone Location of microphone 16 · Altherma · Outdoor units · Outdoor units · R-410A · ERYQ 7 7-1 Sound pressure level (dB) Sound data Sound pressure spectrum ERYQ007ABV3 Heating Sound pressure level (dB) ERYQ006ABV3 Heating 1 7 3TW56717-2 NOTES 1 2 3 4 Octave band center frequency (Hz) 3TW56717-2 NOTES Octave band center frequency (Hz) Data is valid at free field condition (measured in a semi-anachoic room) dB(A) = A-weighted sound power level (A-scale according to IEC) Reference acoustic pressure 0dB = 20Pa If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Coil Microphone 1 2 3 4 Location of microphone Data is valid at free field condition (measured in a semi-anachoic room) dB(A) = A-weighted sound power level (A-scale according to IEC) Reference acoustic pressure 0dB = 20Pa If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Coil Microphone Location of microphone · Altherma · Outdoor units 17 · Outdoor units · R-410A · ERYQ 8 Operation range 1 8 Cooling mode Outdoor temp. (°CDB) Leaving evaporator water temperature (°C) Outdoor temp. (°CDB) Heating mode Leaving condenser water temperature (°C) Outdoor temp. (°CDB) Sanitary mode : Booster heater operation only Leaving condenser water temperature (°C) 4TW56713-1A 18 · Altherma · Outdoor units · Indoor units · R-410A · EKHBH / EKHBX TABLE OF CONTENTS EKHBH / EKHBX 1 2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 21 23 24 3 4 5 6 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensional drawing & centre of gravity . . . . . . . . . . . . . . . . . . . . . . . 25 Dimensional drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Piping diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Wiring diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . External connection diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 29 7 Hydraulic performance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Static pressure drop unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 · Altherma · Indoor units 19 · Indoor units · R-410A · EKHBH / EKHBX 1 H t K i E n u a/ m r rA Ho e0 Bo h1 Hd t4 nKl- EI· AR · Features Cost effective alternative to a fossil fuel boiler Low energy bills and low CO2 emissions · · Easy to install Total solution for year round comfort 2 1 20 · Altherma · Indoor units · Indoor units · R-410A · EKHBH / EKHBX 2 2-1 Specifications TECHNICAL SPECIFICATIONS W EKHBH007A (+ERYQ005A) EKHBH007A (+ERYQ006A) EKHBH007A (+ERYQ007A) EKHBX007A (+ERYQ005A) EKHBX007A (+ERYQ006A) EKHBX007A (+ERYQ007A) Outdoor units Nominal input (Indoor only) Casing Dimensions Colour Material Packing Height Width Depth Unit Height Width Depth Weight Packing Unit Packed Unit Material mm mm mm mm mm mm kg kg ERYQ005A ERYQ006A ERYQ007A 230 ERYQ005A ERYQ006A ERYQ007A RAL9010 Polyester painted galvanised steel 1225 660 595 895 487 361 55 65 EPS Wood Carton PS(straps) 936 487 461 65 75 2 2 Weight Main components Pump Main components Pump Nominal ESP unit Pump Water side Heat exchanger Type kg Nr. of speed Cooling Heating Power input Type Qty Water volume Water flow rate Min. l l/min kPa kPa W 46.5 40.1 29.0 10 Water cooled 3 49.9 46.5 130 Brazed plate 1 0.67 12 46.5 40.1 44.4 29.0 Water side Heat exchanger Main components Water flow rate Nom. Water side Heat exchanger Expansion vessel Cooling Heating l/min l/min 16.5 19.6 24.2 14.7 16.5 16.5 19.6 17.6 24.2 Insulation material Polyurethane foam Volume Max. water pressure Pre pressure l bar 10 3 bar mm 1 1 Water filter Diameter perforations Material Brass inch inch bar 1"MBSP 1"MBSP 3 Yes Yes Yes Yes Water circuit Piping connections diameter Piping Safety valve Manometer Drain valve / Fill valve Shut off valve Air purge valve · Altherma · Indoor units 21 · Indoor units · R-410A · EKHBH / EKHBX 2 2-1 Specifications TECHNICAL SPECIFICATIONS Gas side diameter Liquid side diameter Sound Pressure Waterside Cooling Heating mm mm dBA °C °C EKHBH007A (+ERYQ005A) EKHBH007A (+ERYQ006A) EKHBH007A (+ERYQ007A) EKHBX007A (+ERYQ005A) EKHBX007A (+ERYQ006A) EKHBX007A (+ERYQ007A) Refrigerant Circuit 15,9 (2) 27 7 ~ 20 30 ~ 55 The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment. ERYQ = 6.35 mm EKHB = 9.52 mm (flare connection) 2 2 Sound Level Operation range Notes 22 · Altherma · Indoor units · Indoor units · R-410A · EKHBH / EKHBX 2 2-2 Electric heater Specifications ELECTRICAL SPECIFICATIONS Type Power Supply Phase Frequency Voltage Current Running Current Phase Frequency Voltage Current Running Current Phase Frequency Voltage Current Running Current Phase Frequency Voltage Current Running Current Phase Frequency Voltage Current Running Current Phase Frequency Voltage Current Running Current Hz V A Hz V A Hz V A Hz V A Hz V A Hz V A EKHBH007A (+ERYQ005A) EKHBH007A (+ERYQ006A) EKHBH007A (+ERYQ007A) EKHBX007A (+ERYQ005A) EKHBX007A (+ERYQ006A) EKHBX007A (+ERYQ007A) 3V3 1 50 230 13 6V3 1 50 230 26 6W1 3N 50 400 8.6 6T1 3 50 230 15 9W1 3N 50 400 13 9T1 3 50 230 23 2 2 Electric heater Type Power Supply Electric heater Type Power Supply

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DAIKIN EKHBX007A.

DAIKIN offer a product for which we do not have the user manual? Let us know what you are looking for: user guide, owner's manual, online manual, operating instructions, quick start guide, mounting instructions, schematics, service manual, installation instructions, RTFM.

Diplodocs allows you to download user manual DAIKIN EKHBX007A, user guide DAIKIN EKHBX007A, instructions DAIKIN EKHBX007A, owner's manual DAIKIN EKHBX007A, online manual DAIKIN EKHBX007A.


DAIKIN EKHBX007A, , Heating & Air Conditioning.