9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your DAIKIN EKHBX007A : user manual, user guide, instruction manual.
Search a brand
Advanced Search

Need help using a product?
Look at the reviews on DAIKIN EKHBX007A

User manual DAIKIN EKHBX007A

Diplodocs help download the user guide DAIKIN EKHBX007A .

Download the complete user guide (1141 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide DAIKIN EKHBX007A

Detailed instructions for use are in the User's Guide.

EEDE06-9 technical data Altherma ERYQ005-007A EKHBH007A / EKHBX007A EKSWW150-300 Altherma ERYQ005-007A EKHBH007A / EKHBX007A EKSWW150-300 " The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, In the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.." ISO14001 assures an effective environmental management system in order to help protect human health and the environment from potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment. Daikin units comply with the European regulations that guarantee the safety of the product. Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. Zandvoordestraat 300 B - 8400 Ostend Belgium www.daikineurope.com EEDE0 6 - 9 EEDE06-9 - 07/2006 Printed in Belgium by Goekint Graphics EEDE06-9 technical data Altherma ERYQ005-007A EKHBH007A / EKHBX007A EKSWW150-300 · Chillers · R-410A · ALTHERMA erA el0 hl1 t4i l-h RAC Cooling only Heating only Heat pump 4 · Altherma · Chillers · Outdoor units · R-410A · ERYQ TABLE OF CONTENTS ERYQ 1 2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Nominal Capacity and Nominal Input ............................... 7 7 9 ....................................................................... 7 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 4 Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cooling/Heating capacity tables 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Dimensional drawing & centre of gravity . . . . . . . . . . . . . . . . . . . . . . . 11 Dimensional drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 12 5 6 Piping diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Wiring diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . External connection diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 15 7 8 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Sound pressure spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 18 Operation range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . · Altherma · Outdoor units 5 · Outdoor units · R-410A · ERYQ 1 i n u a r m o rA o e0 dh1Q t4Y ulR- EAO· R Features Cost effective alternative to a fossil fuel boiler Low energy bills and low CO2 emissions · · Easy to install Total solution for year round comfort 1 1 · 6 · Altherma · Outdoor units · Outdoor units · R-410A · ERYQ 2 Specifications EKHBH* ERYQ005A ERYQ006A ERYQ007A ERYQ005A EKHBX* ERYQ006A ERYQ007A 2-1 NOMINAL CAPACITY AND NOMINAL INPUT Indoor Units Condition 1 Heating capacity Cooling capacity Heating PI Cooling PI COP EER Condition 2 Heating Minimum Nominal Minimum Nominal Nominal Nominal Nominal Nominal Minimum Nominal Cooling Minimum Nominal Heating PI Cooling PI COP EER Notes Nominal Nominal Nominal Nominal kW kW kW kW kW kW kW kW kW kW kW kW - EKHBH007A* 4.36 5.75 7.45 1.26 4.56 3.87 5.03 6.68 1.58 3.18 - EKHBH007A* 4.36 6.84 8.79 1.58 4.34 3.87 6.10 7.98 1.95 3.13 - EKHBH007A* 4.36 8.43 9.58 2.08 4.05 3.87 7.64 8.76 2.54 3.00 - EKHBX007A* 4.36 5.75 7.45 3.67 5.12 5.12 1.26 2.16 4.56 2.37 3.87 5.03 6.68 4.82 7.20 7.20 1.58 2.16 3.18 3.33 EKHBX007A* 4.36 6.84 8.79 3.67 5.86 6.13 1.58 2.59 4.34 2.26 3.87 6.10 7.98 4.82 8.16 8.50 1.95 2.59 3.13 3.15 EKHBX007A* 4.36 8.43 9.58 3.67 6.08 7.10 2.08 2.75 4.05 2.21 3.87 7.64 8.76 4.82 8.37 8.91 2.54 2.75 3.00 3.04 1 2 Maximum kW Maximum kW Maximum kW Maximum kW *Condition 1 - cooling Ta 35°C - LWE 7°C - heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) * Condition 2 - cooling Ta 35°C - LWE 18°C (DT = 5°C) - heating Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) ERYQ005A (+ EKHBH) ERYQ006A (+ EKHBH) ERYQ007A (+ EKHBH) ERYQ005A (+ EKHBX) ERYQ006A (+ EKHBX) ERYQ007A (+ EKHBX) 2-2 Casing TECHNICAL SPECIFICATIONS Colour Material Unit Height Width Depth Packing Height Width Depth mm mm mm mm mm mm kg kg Ivory white Polyester painted galvanised steel 797 960 390 735 825 300 56 61 EPS Carton kg Length Nr of Rows Fin Pitch mm Nr of Stages mm 5 845 2 1.8 32 Hi-Xa(8) Type Treatment WF fin Anti-corrosion treatment (PE) Propeller 1 Quantity Output W 1 53 1 Model Type Motor Output W 2YC63BXD#C Hermetically sealed swing compressor 1920 Dimensions Weight Packing Unit Packed Unit Material Weight Heat Exchanger Dimensions Tube type Fin Fan Type Quantity Motor Compressor Quantity Motor · Altherma · Outdoor units 7 · Outdoor units · R-410A · ERYQ 2 2-2 Specifications TECHNICAL SPECIFICATIONS Heating Cooling Sanitary water Min Max Min Max Min Max Sound Power Sound Pressure Cooling Sound Power Sound Pressure °CWB °CWB °CDB °CDB °CDB °CDB dBA dBA dBA dBA R-410A kg 1.7 Expansion valve(electronic type) 1 FVC50K l Type Diameter (OD) Gas Type Diameter (OD) Drain Quantity Type Diameter (OD) Piping Length Minimum mm m kg/m mm mm 0.75 Flare connection 6,35 Flare connection 15,9 1 Socket 18 3 30 0.02 IF > 10m 15 64 48 64 48 66 52 -20 43 64 48 63 47 64 48 64 47 66 52 66 53 ERYQ005A (+ EKHBH) ERYQ006A (+ EKHBH) ERYQ007A (+ EKHBH) ERYQ005A (+ EKHBX) ERYQ006A (+ EKHBX) ERYQ007A (+ EKHBX) 1 2 Operation Range -20 25 7 20 Sound Level (nominal) Heating Refrigerant Type Charge Control Nr of Circuits Refrigerant Oil Piping connections Type Charged Volume Liquid (OD) Maximum m Additional Refrigerant Charge Installation height difference Maximum m Max. internunit level difference Defrost Method Defrost Control Capacity Control Method Standard Accessories Item Quantity Item Quantity m 20 Reverse cycle Sensor for outdoor heat exchanger temperature Inverter controlled Installation manual 1 Drain plug 1 8 · Altherma · Outdoor units · Outdoor units · R-410A · ERYQ 2 2-3 Specifications ELECTRICAL SPECIFICATIONS Name Phase Frequency Voltage Voltage range Hz V Maximum V Cooling Heating Cooling Heating A A A A A 18 20 3 4 Included earth wiring 11 16.25 ERYQ005A (+ EKHBH) ERYQ006A (+ EKHBH) ERYQ007A (+ EKHBH) ERYQ005A (+ EKHBX) ERYQ006A (+ EKHBX) ERYQ007A (+ EKHBX) Power Supply V1 1~ 50 220-440 +10% 11 1 2 Current Starting Current Maximum running Current Recomended fuses Wiring connections For Power Supply Quantity For connection Quantity with indoor Remark · Altherma · Outdoor units 9 · Outdoor units · R-410A · ERYQ 3 3-1 COOLING Capacity tables Cooling/Heating capacity tables Tamb (°C) LWE (°C) 7 11 13 16 20 7 11 13 16 20 7 11 13 16 20 LWC Tamb -15 -10 -7 -2 2 7 -15 -10 -7 -2 2 7 -15 -10 -7 -2 2 7 LWC Tamb -15 -10 -7 -2 2 7 -15 -10 -7 -2 2 7 -15 -10 -7 -2 2 7 20 CC 6.01 6.81 7.23 7.88 8.80 7.15 8.09 8.57 9.33 10.4 8.24 9.26 9.79 10.6 11.7 30 HC 3.93 4.65 5.14 6.06 6.89 8.03 4.87 5.67 6.21 7.23 8.14 9.40 5.42 6.27 6.84 7.92 8.9 10.2 30 HC 3.50 4.14 4.52 5.27 5.92 8.03 4.34 5.04 5.46 6.29 7.00 9.40 4.82 5.58 6.02 6.89 7.6 10.2 PI 1.40 1.45 1.45 1.46 1.45 1.57 1.73 1.79 1.80 1.81 1.81 1.98 1.96 2.03 2.04 2.07 2.08 2.28 HC 3.27 3.85 4.20 4.89 5.49 7.45 4.11 4.75 5.13 5.89 6.55 8.79 4.59 5.28 5.69 6.48 7.18 9.58 PI 1.48 1.52 1.54 1.57 1.57 1.57 1.82 1.88 1.91 1.95 1.97 1.98 2.06 2.13 2.17 2.22 2.26 2.28 HC 3.67 4.32 4.77 5.62 6.38 7.45 4.62 5.34 5.83 6.77 7.61 8.79 5.16 5.93 6.46 7.45 8.35 9.58 35 PI 1.51 1.56 1.58 1.60 1.60 1.75 1.85 1.92 1.94 1.98 1.99 2.19 2.08 2.17 2.20 2.25 2.27 2.51 HC 3.09 3.62 3.95 4.59 5.16 7.00 3.94 4.53 4.88 5.59 6.20 8.32 4.43 5.06 5.43 6.17 6.82 9.10 PI 1.56 1.57 1.57 1.56 1.55 2.05 2.09 2.11 2.13 2.16 2.43 2.49 2.52 2.57 2.63 CC 5.73 6.50 6.90 7.54 8.42 6.84 7.73 8.20 8.92 9.9 7.90 8.87 9.38 10.17 11.3 35 PI 1.59 1.65 1.68 1.72 1.74 1.75 1.94 2.02 2.07 2.13 2.16 2.19 2.19 2.29 2.34 2.41 2.46 2.51 HC 3.47 4.07 4.49 5.28 6.00 7.00 4.43 5.09 5.55 6.42 7.21 8.32 4.97 5.68 6.17 7.10 7.93 9.10 40 PI 1.62 1.70 1.72 1.75 1.76 1.94 1.98 2.07 2.10 2.15 2.18 2.42 2.23 2.34 2.37 2.44 2.47 2.76 HC 2.97 3.46 3.77 4.38 4.92 6.68 3.83 4.38 4.71 5.37 5.96 7.98 4.32 4.91 5.26 5.96 6.58 8.76 25 PI 1.75 1.77 1.78 1.78 1.79 2.28 2.34 2.36 2.40 2.44 2.68 2.76 2.80 2.86 2.94 CC 5.43 6.17 6.56 7.17 8.03 6.50 7.34 7.79 8.49 9.48 7.52 8.45 8.93 9.69 10.75 40 PI 1.71 1.79 1.83 1.88 1.91 1.94 2.08 2.18 2.24 2.32 2.37 2.42 2.34 2.46 2.53 2.62 2.69 2.76 HC 3.33 3.89 4.28 5.03 5.72 6.68 4.30 4.92 5.35 6.17 6.92 7.98 4.86 5.51 5.97 6.85 7.65 8.76 45 PI 1.75 1.84 1.87 1.92 1.94 2.15 2.12 2.24 2.28 2.35 2.38 2.66 2.39 2.52 2.57 2.65 2.70 3.02 HC 2.89 3.36 3.65 4.24 4.76 6.47 3.77 4.29 4.60 5.23 5.80 7.78 4.27 4.82 5.15 5.83 6.43 8.56 30 PI 1.95 1.98 2.00 2.01 2.03 2.52 2.59 2.63 2.68 2.73 2.94 3.05 3.10 3.17 3.26 CC 5.12 5.83 6.20 6.79 7.63 6.13 6.94 7.36 8.03 8.99 7.10 7.79 8.14 8.68 9.39 45 PI 1.84 1.94 1.99 2.06 2.11 2.15 2.23 2.36 2.42 2.52 2.59 2.66 2.51 2.65 2.73 2.85 2.93 3.02 HC 3.25 3.78 4.15 4.87 5.53 6.47 4.24 4.82 5.23 6.02 6.74 7.78 4.80 5.42 5.86 6.70 7.47 8.56 50 PI 1.89 2.00 2.03 2.10 2.13 2.37 2.28 2.42 2.47 2.56 2.61 2.92 2.56 2.72 2.78 2.88 2.94 3.31 35 PI 2.16 2.21 2.23 2.26 2.29 2.77 2.87 2.91 2.97 3.04 3.23 3.31 3.36 3.41 3.48 CC 4.80 5.30 5.56 5.95 6.48 5.35 5.84 6.09 6.46 6.96 5.68 6.12 6.34 6.67 7.09 50 PI 1.99 2.10 2.16 2.25 2.31 2.37 2.40 2.55 2.63 2.75 2.83 2.92 2.70 2.86 2.95 3.10 3.20 3.31 * The integrated heating capacity and power input, is the average heating capacity and power input during 1 cycle. (from end of defrost till end of the next defrost). 1 3 Model 40 PI 2.39 2.32 2.28 2.22 2.13 2.68 2.62 2.59 2.53 2.44 2.86 2.80 2.77 2.71 2.61 CC 4.59 4.98 5.18 5.46 5.82 4.89 5.21 5.36 5.57 5.82 4.87 5.18 5.33 5.55 5.80 43 PI 2.53 2.38 2.30 2.18 1.99 2.59 2.43 2.34 2.20 1.99 2.59 2.43 2.35 2.20 1.99 005 006 007 HEATING (Peak values) Model 005 006 007 HEATING (integrated values*) Model 005 006 007 4TW56712-1A SYMBOLS CC HC PI LWE LWC Tamb : Cooling capacity at maximum operating frequency, measured acc. Eurovent 6/C/003-2006 (kW) : Heating capacity at maximum operating frequency, measured acc. Eurovent 6/C/003-2006 (kW) : Power input (kW) : Leaving Water Evaporator temperature (°C) : Leaving Water Condensor temperature (°C) : Ambient temperature (°C) RH=85% 1 NOTES Cooling capacity Capacity is according to Eurovent rating standard 6/C/003-2006 and valid for chilled water range Dt = 38°C Heating capacity Capacity is according to Eurovent rating standard 6/C/003-2006 and valid for chilled water range Dt = 38°C Power input Power input is total input according to Eurovent rating standard 6/C/003-2006 2 3 10 · Altherma · Outdoor units · Outdoor units · R-410A · ERYQ 4 4-1 ERYQ Dimensional drawing & centre of gravity Dimensional drawing unit (mm) 1 4 Drain outlet (I.D. J 15.9 hose for connection) Minimum space for air passage Wall height on air outlet side = less than 1200 In case of removing stop valve cover 4 x holes for anchor bolts (M8 or M10) Name plate Brand name label Wiring inlet Terminal strip with earth terminal Outdoor air thermistor Liquid stop valve (J6.4 CuT) Service port Gas stop valve (J15.9 CuT) 3D051658B · Altherma · Outdoor units 11 · Outdoor units · R-410A · ERYQ 4 4-2 ERYQ Dimensional drawing & centre of gravity Centre of gravity 1 4 The position of foundation bolt 4D042258G 12 · Altherma · ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.