9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your DANBY DAC10007EE : user manual, user guide, instruction manual.
Search a brand
Advanced Search

Need help using a product?
Look at the reviews on DANBY DAC10007EE

User manual DANBY DAC10007EE

Diplodocs help download the user guide DANBY DAC10007EE .

Download the complete user guide (2058 Ko)



This product, although classified under the brand DANBY, may have been manufactured by SIMPLICITY after mergers, acquisitions, or a change in name.



Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide DANBY DAC10007EE

Detailed instructions for use are in the User's Guide.

USE AND CARE MANUAL MANUEL D'UTILISATION Models · Modèles DAC7077EE DAC8007EE DAC10007EE DAC12077EE DAC12507EE Room Air Conditioner Table of contents . . . . . . . . . . . . . . . . . . . . . . . 1 CAUTION: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product. Climatiseur de pièce Table of contents . . . . . . . . . . . . . . . . . . . . . . . 12 PRÉCAUTION: Veuillez lire attentivement les consignes de sécurité et les instructions d'utilisation avant l'utilisation initiale de ce produit. Danby Products Limited, Guelph, Ontario Canada N1H 6Z9 Danby Products Inc., Findlay, Ohio USA Version 1C.2.06 Introduction Thank you for choosing a Danby Room Air Conditioner to cool your home. This Use and Care Manual provides information necessary for the proper care and maintenance of your new Room Air Conditioner. If properly maintained, your air conditioner will give you many years of trouble free operation. To avoid installation difficulties, read these instructions completely before installing/operating your unit. NOTE: This unit is NOT designed for through-the-wall installation. For easy reference, you may want to attach a copy of your sales receipt to this page. Note the following information provided (on the manufacturer's nameplate located on the unit). This information will be needed when you contact a Customer Service Representative. Model Number: Serial Number: ___________________________________________________ Date of Purchase: _________________________________________________ Dealer's Name and Address: _________________________________________ ________________________________________ Refer to the trouble shooting section of this Use and Care Manual if the unit is not operating correctly. If these suggestions do not solve the problem, contact an authorized service representative or call Danby TOLL FREE: 1-800-26-Danby CAUTION This symbol denotes a caution or warning Do not leave a room air conditioner unattended in a space where people or animals who cannot react to a failed unit are located. A failed unit can cause extreme overheating and fire in an enclosed, unattended space. SAVE THESE INSTRUCTIONS! 2 Electrical Specifications 1. All wiring must comply with local and national electrical codes and must be installed by a qualified electrician. If you have any questions regarding the following instructions, contact a qualified electrician. 2. Check available power supply and resolve any wiring problems BEFORE installing and operating this unit. 3. This 115V air conditioner uses 10.1 or less (depending on model) nameplate amps and may be used in any properly wired, general purpose household receptacle. See Table 1 for specifications for individual branch circuit. 4. For your safety and protection, this unit is grounded through the power cord plug when plugged into a matching wall outlet. If you are not sure whether your wall outlet is properly grounded, please consult a qualified electrician. 5. The wall outlet (3-pin) must match the plug (3pin) on the service cord supplied with the unit. DO NOT use plug adapters. See Table 2 for receptacle and fuse information. DO NOT USE "REGULAR" EXTENSION CORDS WITH THIS UNIT. If it is necessary to use an extension cord to connect your air conditioner, use an approved "air conditioner" extension cord only. (available at most local hardware stores) 6. The rating plate on the unit contains electrical and other technical data. Table 1: Suggested Individual Branch Circuit Nameplate Amps AWG Wire Size* 4.9 to 10.1 14 AWG- American Wire Gage * Based on copper wire at 60 °C temperature rating. Table 2: Receptacle and Fuse Types Rated Volts Amps Wall Outlet Fuse Size Time Delay Fuse (or circuit breaker) 15 Plug Type 125 15 3 Energy-Saving Tips Your Room Air Conditioner is designed to be highly efficient in energy savings. Follow these recommendations for greater efficiency. 1. Select thermostat setting that suits your comfort needs and leave thermostat at that chosen setting. 2. The filter is very efficient in removing airborne particles. Keep air filter clean. Normally, filter should be cleaned every 2 weeks. More frequent cleaning may be necessary depending on indoor air quality. 3. Use drapes, curtains, or shades to keep direct sunlight from heating room, but DO NOT obstruct the air conditioner. Allow air to circulate around the unit without obstruction. 4. Start your air conditioner before outdoor air becomes hot and uncomfortable. This avoids an initial period of discomfort while unit is cooling off the room. 5. When outdoor temperatures are cool enough, use HIGH or LOW FAN only. This circulates indoor air, providing some cooling comfort, and utilizes less electricity than when operating on a cooling setting. Installation Notes Electric Shock Hazard To avoid the possibility of personal injury, disconnect power to the unit before installing or servicing. Installation Hardware 3/4" (19.1 mm) Screws (9) *3/8" (9.5 mm) Screws (4) *Factory installed on some models. Safety Lock (1) *"L" Shaped mounting bracket (1) Tools Needed for Installation Screw Drivers: Both Phillips and flat head Power Drill: 1/8 inch (3.2 mm) diameter drill bit Pencil Measuring Tape Scissors Carpenters Level *Factory installed on some models. Sash bracket (2) Adhesive Foam Seal (1) Side Curtain RH (1) Side Curtain LH (1) CAUTION To avoid installation/operation difficulties, read these instructions thoroughly. Your Room Air Conditioner is designed for easy installation in a single or double-hung window. This unit is NOT designed for vertical (slider type) windows and/or through-the-wall applications. NOTE: Save the shipping carton and packing materials for future storage or transport of the unit. Remove from carton, the plastic bag containing the installation hardware kit necessary for the installation of your air conditioner. Please check the contents of hardware kit against the corresponding model check list, prior to installation of the unit. See Fig. 1 4 Fig. 1 CAUTION Because the compressor is located towards the rear of the unit, this side will be heavier and more awkward to manipulate. Therefore, it is recommended to have someone assist you during the installation of this unit. Your unit is designed to evaporate condensation under normal conditions. However, under extreme humidity conditions, excess condensation may cause basepan to overflow to the outside. The Unit should be installed where condensation run-off cannot drip on pedestrians or neighboring properties. Installation Select the Best Location A. This room air conditioner is designed to fit easily into a single or double hung window. However, since window designs vary, it may be necessary to make some modifications for safe, proper installation. B. Make sure window and frame are structurally sound and free from dry and rotted wood. C. For maximum efficiency, install the air conditioner on a side of a house or building which favors more shade than sunlight. If the unit is in direct sunlight, it is advisable to provide an awning over the unit. D. Provide sufficient clearance around the cabinet to allow for ample air circulation through the unit. See Fig. 2. The rear of the unit should be outdoors and not in a garage nor inside a building. Keep unit as far away as possible from obstacles/obstructions and at least 30" (76.2 cm) above the floor or ground. Curtains and other objects within a room should be prevented from blocking the air flow. E. Be certain the proper electrical outlet is within reach of the installation. Use only a single outlet circuit rated at 15 amps. All wiring should be in accordance with local and national electrical codes. F. DO NOT USE "REGULAR" EXTENSION CORDS WITH THIS UNIT. If it is necessary to use an extension cord to connect your air conditioner, use an approved "air conditioner" extension cord only. (available at most local hardware stores) G. DO NOT install unit where leakage of combustible gas is suspected. Your air conditioner may fail to operate in air containing oils (including machine oils), sulfide gas, near hot springs, etc... 5 30"(76.2 cm) Min. Ground 20" (50.8 cm) Min. Awning 12"(30.5 cm) Min. 20" (50.8 cm) Min. Side obstruction Fig. 2 Fence, wall, or other obstacle. 1. Assembly of the Upper Channel, to Cabinet. (Factory installed on some models) "L" Shaped Top Channel: Install the "L" shaped channel to the top of the cabinet as shown in Fig. 3 using four (4) 3/8"(9.5mm) screws. 3/8" (9.5mm) Screw 3a. Completing the Installation (cont'd) · Carefully place the air conditioner into the window with the "L" shaped mounting bracket (on top) positioned in front of the upper window sash. The bottom of the cabinet should be positioned on the "recessed" portion of the window frame. Pull the window down until it rests just behind the front flange of the (top) "L" shaped mounting bracket. See Fig. 5. Expand the shutter frames (fully) on each side and secure the top of the frames to the window sash using one 3/4" (19.1 mm) screw on each side and one in the "L" shaped mounting bracket. Fig. 5 Secure the shutter clamp on each side of the (lower) shutter and secure to window sill using one 3/4" (19.1mm) screw on each side. Fig.5 Window Sash · · "L" Shaped Mounting Bracket · Fig. 3 "U" Shaped Channel (Factory Installed) 2. · Assembly of the Side Curtains to Cabinet. Extend the shutter from the shutter frame and slide it into the shutter guide on the side channel of the air conditioner as shown in Fig. 4. Slide the shutters into the top ("L" Shaped) and bottom ("U" Shaped channels. The shutters are identified (on frame) as left & right. Sl id e 3/4" (19.1mm) Screws · "L" Shaped Mounting Bracket Fig. 5 Shutter clamps do w n in to gu id e · Place the second foam sealing strip to fit the opening between the inside and outside windows then attach the safety lock to the outside window frame using one 3/4" (19.1 mm) screw. See Fig. 6. Safety Lock Foam Seal Shutter Shutter Frame Fig. 4 3/4" (19.1 mm) Screw Fig. 6 3. Completing the Installation Cut the foam (non adhesive) sealing strip to fit the area of the window sill that the air conditioner will rest on. 6 · PLEASE NOTE: Window applications come in a variety of different styles. Therefore, it may be necessary to modify or improvise your particular installation. Key Pad Features LED DISPLAY: Displays the following information independently; Set Temperature, Ambient Room Temperature and Auto Timer On/Off settings. POWER: Turns unit On / Off. MODE LED DISPLAY Temp/Timer Control 68 Auto Timer MODE: Allows you to scroll through and select the desired operating mode; Cool , Dry , Fan Only and *Auto Auto . The selected mode will be denoted by the adjacent indicator light. *`Auto' is a pre-set factory program that automatically defines the mode (Cool or Dry) and fan speed based on the set temperature. FAN SPEED: Select from four different fan settings; Check Filter Sleep Mode Auto Auto Low , Medium , High and Auto Auto during Cool and Fan Only mode. Please note: During `Dry' mode the fan speed is automatically defined . ENERGY SAVER: Automatically cycles the fan on and off while the compressor is not in use. TEMP. /TIMER Control: Used to increase or decrease the Temperature setting in 1°C / °F increments.and Auto-Timer On/Off settings in 30 min./1hr. increments. MODE Mode Selector Fan Speed Energy Saver Power Button AUTO-TIMER: Used to Initiate the Auto On and/or Auto Off timer. While the Air Conditioner is off (Auto-On): 1. Press the Auto-Timer button once and the adjacent Auto-On indicator light ` ` will illuminate. 2. Use the Temp/Timer control cursors to select a delayed On time of up to 24 hours. 3. Select the appropriate mode under which you want the unit to operate (Auto-Cool-Dry-Fan Only) 4. Select the fan speed setting. 5. The time you selected will appear in the LED display.. While the Air Conditioner is on (Auto-Off); 1. Press the Auto-Timer button twice and the adjacent Auto-Off indicator light will illuminate. 2. Use the Temp/Timer control cursors to select a delayed Off time of up to 24 hours. 3. The time you selected will appear in the LED display The Auto On and Auto Off timer can operate during the same program by defining the Auto-Off parameters immediately after the Auto On parameters. The Auto-Timer may be cancelled at any time by turning the unit On/Off. Note: This appliance allows you select the temperature scale to be displayed in either "Celsius" or Fahrenheit" according to your preference. To change the temperature scale displayed on the electronic display, press both the "Temp/Timer" adjust arrows simultaneously to alternate between "Celsius" & "Fahrenheit". CHECK FILTER : The adjacent indicator light will illuminate as a reminder to clean the air conditioner filter (see page 9) Once the filter has been cleaned and replaced, depress the Check Filter button in order to resume ope ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.