Download user guide, user manual, owner manual and instructions guide
5 600 brands
1 870 000 user's guides
Search a brand
Advanced Search



Our partners wish to propose you the following products


Visit DELONGHI official site

User manual DELONGHI BLUE FLAME GAS HEATER SBF BLACK

Diplodocs help download the user guide DELONGHI BLUE FLAME GAS HEATER SBF BLACK.



Download the user manual DELONGHI BLUE FLAME GAS HEATER SBF BLACK  
Download the complete
user guide (502 Ko)
Need help, support, reviews, tips or troubleshooting for your DELONGHI BLUE FLAME GAS HEATER SBF BLACK products ?

Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
User guide DELONGHI BLUE FLAME GAS HEATER SBF BLACK

Detailed instructions for use are in the User's Guide.

BLUE FLAME GAS HEATER SAFETY INSTRUCTION (Keep in a safe place) SPARE COPIES OF THIS LEAFLET CAN BE OBTAINED FROM YOUR DEALER manifactured by DE'LONGHI Via L.Seitz, 47 TREVISO 31100 ITALY U.K. AGENT: De'Longhi LTD. 15/16 Bridle Close - Stewarts Road Finedon Industrial Estate Wellingborough Tel. 01933442040 HEATER SAFETY INSTRUCTIONS. (KEEP IN A SAFE PLACE). SPARE COPIES OF THIS LEALET CAN BE OBTAINED FROM YOUR DEALER INSTRU CTION 1 ALWAYS use Heater in accordance with instructions supplied with each Heater. Keep instructions in a safe place. 2 DO NOT position Heater close to chairs and fabrics 3 DO NOT move Heater from room to room when it is lit. 4 DO NOT place clothes or other materials on the Heater, as apart from the danger of fire their presence could affect the efficient working of the appliance. 5 DO NOT position Heater alongside a wall or near curtains, etc. ALWAYS face Heater towards centre of room. Special care should be taken if the Heater is on a surface where it can move or twist on its wheels or castors if knocked by a child or dog, etc. 6 A LEAK WILL SMELL IF a leak is suspected, turn the gas off at the cylinder. DO NOT disconnect the regulator. Extinguish all naked lights. Check all connections. Slowly turn the gas on and brush the connectors with soapy water or liquid detergent - a gas leak will form bubbles. If a leak is found turn the gas off and inform your Dealer. DO NOT use the heater again until it has been inspected by your Dealer. If the cylinder valve appears to be leaking when turned off, refit the Black Branch Cap or Orange valve Cap. - This appliance MUST NOT be used in a basement, high rise flats, bathrooms or bedrooms and in rooms having volume less than 15 m3 (30m3 in living rooms) for three burner models; 18m3 (36m3 in living rooms) for two burner models. - Be sure installation is complying to local standard. - Do not install the appliance in a room which might contain gas, oil or sulphur, or near sources of heat. - The heater you have purchased is fitted with safety devices which come on in the event of malfunctioning while the appliance is in use. If the pilot (placed opposite the burner) accidentally goes out, or if the room is not sufficiently ventilated, the safety device will block the gas flow, causing the heater to go off. VENTILATION USE ONLY IN WELL VENTILATED ROOM. DO NOT CHANGE CYLINDERS IN THE PRESENCE OF NAKED LIGHTS. NEVER USE A MATCH OR NAKED FLAME TO SEARCH FOR LEAKS. ASSEMBLY Gas cylinder compartment 1) Place the gas cylinder in the gas cylinder compartment and connect the regulator to the cylinder as shown on page 3. 2) To fit the backcover, insert the two tabs located on the left-hand side of the backcover into the corresponding slots in the cabinet. Then insert the tab on the right hand side into its slot. IMPORTANT: to remove the backcover, lift the backcover and pull clear of the slots. Slot Tabs 2 MODEL No. 634R SWITCH ON REGULATOR Suitable for Calor Switch-on (21 mm) Gas Bottle Connecting the cylinder ROTATE the plastic cap on the CYLINDER VALVE until the arrow points out through the gap in the valve shroud. PULL the lanyard out, then upwards. The cap will lift off the valve. Do not use tools. Leave the cap hanging down from the valve while the cylinder is in use. Assembly on the gas cylinder Make sure that: - all taps on the consuming appliace are closed; - the connecting pipe to the appliance is correctly fitted; - The Quick-on regulator handle is in the closed position (fig. 3). With no flame on, remove the seal cap on the cylinder automatic valve, place the Quick-on onto the automatic valve and push down firmly and vertically. You will hear a "click" sound which means the regulator is securely latched (fig. 4). Note: Quick-on is so designed as to prevent it from being fitted to the valve, unless the regulator handle is in the closed position; therefore, never attempt to mount or dismount it, if the handle is not in this position. OPEN Handle vertically flame On Handle horizontally flame Off CLOSED fig.3 Operation Once the Quick-on is correctly mounted on the valve, gas supply is possible by turning the regulator handle upwards (counterclockwise). To shut off the gas supply, reverse above procedure; an arrow engraved on the handle indicates the closing direction (fig.3). Symbols engraved on the bonnet show how to operate the regulator handle. CAUTION: if you are unable, to open the regulator handle, this means that your Quikon is not correctly connected to the valve. Do not force the handle to open, instead start again the operations described above in 3. GAS OFF Replacement of a cylinder Make sure that: - all taps on the consuming appliance are in the closed position. - the Quick-on regulator handle is in the closed position. Then, dismount the Quick-on by pressing horizontally on the handle and pulling upwards at the same time (fig.5). Do not attempt to carry out this operation with the regulator handle in the open position. fig.4 2 1 GAS OFF fig.5 3 GENERAL SAFETY INSTRUCTIONS Type Category See Rating label Max.output Kw 4.2 g/h 305 Med.output Kw 2.85 g/h 207 Low output Kw 1.50 g/h 109 Gas Presure Gas combustion air quantity 8.4 m3/h 28-30 mbar this appliance is designed to operate with butane, at nominal pressure: 28÷30 mbar CYLINDER VALVE If heater does not competely extinguish, including pilot, when gas is turned off at the regulator, do not remove regulator. Return valve to open position and leave heater alight, which is perfectly safe, until attended to by the gas supplier. Regulators, Hoses and clips Check that tubing is completely over the nozzles at each end of the tubing and that is held firmly in place by tube clips. Examine flexible tubing regularly and get your Dealer to fit new tubing 400 mm long if perished, worn or damaged. L.P.G. ATTACKS NATURAL RUBBER-USE ONLY TUBING TO B.S. 3212 TYPE 2 SUPPLIED BY YOUR DEALER. Avoid bending or constricting the rubber tube when the pressure regulator is connected to the gas cylinder. A REGULATOR B.S. 3016 SET AT 28 MBAR (11.2 IN W.G.) for butane must de connected to the appliance with the above tubing, using suitable tube clips. VENTILATION USE ONLY IN A WELL VENTILATED ROOM Adequate ventilation must be provided in rooms in which the heater is use. This ensures removal of the products combustion and allows the entry of replacement air. Adequate ventilation should considerably reduce the possibility of condensation accurring. The following table shows the smallest size of room suitable for each heat setting and the ventilation which must be provided. Heating Setting Room Size 15 m3 Room Vent MIN MAX 42 m3 105 cm2 MED 28,5 m3 MAINTENANCE Ensure that the heater is kept free of dust. When the heater is not in use it should be covered and stored in a dust-free place. Stains on the exterior should be removed with soapy solution when the heater is cold. Dry with a polishing cloth. DO NOT use abrasive cleaners which will damage the paint finishes. Refer any major maintenance to your Local Authorised Dealer. Major servicing should be carried out annually. If in doubt refer to your authorised dealer. SAFETY GUARD The guard on this appliance conforms to the requirements of B.S. 1945: 1971 and satisfies the heater appliance (fireguards) regulations. The guard is to prevent risk of fire or injury from burns and no part of it should be permanently removed. It does not give full protection for young children or the infirm. 4 Positioning the heater: · · · · · DO NOT place clothes or other materials on the heater. DO NOT position heater close to chairs or fabrics DO NOT MOVE the heater across the room when lit. DO NOT POSITION the heater alongside a wall or near curtains etc. ALWAYS face the heater towards the centre of the room. OPERATING INSTRUCTIONS Before connecting a gas container and operating this appliance, please read the heater safety instructions and the operating instructions given below - spare copies may be obtained from your authorised dealer. The gas is turned on and off at the cylinder. The heat input and spark for ignition are controlled by the knob situated at the top right hand side of the heater. LIGHTING THE HEATER: 1) Turn on the gas cylinder by either: OPEN Handle verically flame On Turn the regulator gas switch anti- clockwise to the vertical position (Model No.634R) Handle horizontally flame Off CLOSED 2. FROM POSITION, fully depress the control knob, and turn to position (small flame). If pilot does not ignite return to starting position and repeat). Continue to fully depress the knob for a further 10 seconds to allow the thermocouple probe to heat up, then turn the knob to the required heat setting. CONTROL OF THE HEAT OUTPUT: For low output - leave control knob in position (small flame) For full output - slightly depress knob and rotate to position (big flame) For medium output - slightly depress knob and rotate to position (medium flame)(only on some models) TURNING-OFF THE HEATER The heater will only be totally "OFF" when the supply of gas from the cylinder has been turned "OFF" at the regulator valve. After each use the appliance must be turned "OFF" at the regulator valve. Turn the regulator gas switch clockwise to the position (Model No. 634R) GAS OFF DO NOT ATTEMPT to relight until FIVE minutes have elapsed. WARNING FOR SWITCH-ON SYSTEM: When the heat is alight, NEVER turn the switch on the cylinder to the disconnect position. Wait until heat and pilot go out, then and only then, should the switch be turned to the disconnect position if the cylinder requires changing. It is dangerous to switch to the disconnect position when the heater is alight. 5 5721008000/ 07.03

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DELONGHI BLUE FLAME GAS HEATER SBF BLACK.

DELONGHI offer a product for which we do not have the user manual? Let us know what you are looking for: site Internet, histoire, actualité, filiales, site Internet, mode d'emploi, driver, avis des utilisateurs, meilleur prix des produits, forum d'assistance aux problèmes, annuaire des marques, annuaire des constructeurs, répertoire des marques, répertoire des constructeurs, site Internet de la marque, site Internet du constructeur

Diplodocs allows you to download user manual DELONGHI BLUE FLAME GAS HEATER SBF BLACK, user guide DELONGHI BLUE FLAME GAS HEATER SBF BLACK, instructions DELONGHI BLUE FLAME GAS HEATER SBF BLACK, owner's manual DELONGHI BLUE FLAME GAS HEATER SBF BLACK, online manual DELONGHI BLUE FLAME GAS HEATER SBF BLACK.


Access web reviews DELONGHI BLUE FLAME GAS HEATER SBF BLACK, DE LONGHI, DELONGUI, Heating & Air Conditioning.
Include the add-on to download manuals from your site, forum or blog Frequently Asked Questions Contact Diplodocs team Last searches
Last additions
Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.