Detailed instructions for use are in the User's Guide. I n t r o d u c t i o n a n d Wa r n i n g
Thank
you for choosing this appliance. This Owner's Manual will provide you with valuable information necessary for the proper care and maintenance of your new appliance. If properly maintained, your appliance will give you many years of trouble-free operation. Please take a few moments and read the instructions thoroughly and familiarize yourself with all of the operational aspects of this appliance. This unit can be conveniently moved from room to room within your home and set-up in just minutes.
I M P O R TA N T S A F E G U A R D S
Read all instructions before using this dehumidifier. To reduce the risk of fire, electric shock, or injury to persons when using your dehumidifier follow basic safety precautions, including the following: 1) After transporting the appliance, wait 1 hour before using it. 2) Do not store or use gasoline, oil, sulphur or other flammable vapors and liquids in the vicinity of this or any other appliance. Do not install the appliance near source of heat. Read product labels carefully. Common sense and caution must be used when installing, operating and maintaining any appliance. 3) This appliance must be used by adults only. Do not allow children to play with the appliance. Do not leave children unattended in an area where the appliance is operating. Do not allow them to sit or stand on the appliance. 4) This appliance is designed to dehumidify domestic living areas, and must not be used for other purposes. It must be operated in an encolsed area to be most effective. Close all doors, windows, and other outside openings to the room. 5) The appliance must not be modified in any way, as any modifications may be extremely dangerous. 6) Do not operate any appliance with a damaged cord or plug or after the appliance malfunctions, or has been damaged in any manner. Return appliance to the nearest authorized service facility for examination, repair or adjustment. 7) The use of accessory attachments is not reccommended by the appliance manufacturer. It may cause injuries. 8) Do not use outdoors. 9) For your safety and protection, this dehumidifier is equipped with a three prong grounding plug on the power cord. Do not, under any circumstances, cut or remove the round grounding prong from the plug. 10) Your dehumidifier must plug directly into a properly grounded and polarized three-prong outlet. If the wall outlet will not accept a three prong plug, or if you are not sure the outlet is adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper outlet. Do not use an extention cord or an adapter plug. 11) Never unplug the dehumidifier by pulling on the power cord. Always grip the plug firmly and pull straight out from the outlet. Do not pinch, bend, or knot the power cord. 12) Always remove the plug from the socket before performing cleaning or maintenance operations and when not in use. 13) Do not place heavy or hot objects on the top of the appliance. 14) Clean the air filter at least once a week. 15) The appliance must always remain upright or laid on one side during transportation. Remember to drain the tank before transporting the appliance. 16) WARNING: Handling the cord on this product will expose you to lead, a chemical known to the State of California to cause [cancer, and] birth defects or other reproductive harm. Wash hands after hand ling.
SAVE THESE INSTRUCTIONS
THIS PRODUCT IS FOR HOUSEHOLD ONLY
3
ENGLISH
Description
Descri
ption of the appliance 4
1
2 5 6 3 7 8
1. 2. 3 4. Control panel Cabinet Wheels Air Filter 5. 6. 7. 8. Water Tank Power Cord Continuous Draining Outlet Pump connection (only on some models)
Descri
ption of the control panel
Display MODE button Defrost light
Room temperature button °F/°C ON light
Fan speed button Pump light *
TURBO POWER button
Tank warning light
TIMER button
Decrease humidity level/ time button
STAND-BY button
Increase humidity level/ time button
PUMP button *
* (only on some models)
4
Control panel
STAND-BYbutton
Press this button to start /stop the appliance. To turn the appliance completely off, remove the plug from the outlet.
Room FAN
temperature button
Press this button to display the Temperature on the LCD display. If you press the button once the display will show the °F . If you press the button twice, the display will show the temperature in °C. After few seconds, the display will automatically show the humidity level.
speed button
Press this button to select the Fan Speed (High, Medium, Low).
Decrease TIMER
or increase Humidity Level/ Time buttons
These buttons are used to adjust the desired humidity level, with 5% increments; they are also used to set the timer. From 0 -10 the hours increase by 30 min. and from 10-24 the hours increase by 1 hour increments.
button
With the appliance switched ON, if you press the TIMER button the display will show the hours after which you want the appliance to switch OFF (1-2-3... hours ). With the appliance in the STAND-BY position, if you press the TIMER button the display will show the hours after which you want the appliance to switch ON (1-2-3... hours ).
MODE TURBO PUMP
button
Press this button to select the Fan only or Dehumidifier modes.
POWER button
Use this button to activate the "turbo power" function. In this mode, the appliance will operate at maximum fan speed and in continuous mode. If pressed again, the unit will revert back to previous settings.
button (only on pump models)
Use this button to activate the heavy-duty pump system for active drainage.
5
ENGLISH
Display lights
ON
light
When the STAND-BY button is pressed to start the unit, the ON light will come on automatically. The light will go off again when the unit is switched off. NOTE: After a power outage, the unit will not switch itself on again automatically. When the power supply has been reestablished, please press the STAND-BY button to start the unit again.
TANK
Warning light
If the water tank is full, improperly positioned or missing, the tank warning light will start blinking. An alarm will sound until the tank is either emptied or correctly positioned into place.
DEFROSTING
light
With an ambient temperature of less than 15°C, (59°F) the appliance performs defrosting cycles. While the appliance is defrosting, the defrosting light comes on and remains on until defrosting is completed. During the defrosting cycle only the following 4 keys are active: pump button, stand-by button, temperature button, timer button.
PUMP
light (only on some models)
Once the pump button is pressed the pump light will switch on. If the pump light flashes it means that the pump is not functioning properly.
6
Installation Instructions
1. Allow at least 12 inches (30cm) of space on all sides of the unit for good air circulation. 2. Install your dehumidifier on a floor, table, or shelf. When installing the unit on a table or shelf, make sure the table or shelf is strong enough to support the weight of the unit with a full bucket. Note: The dehumidifier needs to be secured when installed on a table or a shelf. Do not sit or stand on the dehumidifier. 3. The tank must be properly positioned. 4. Castor wheels let you move the dehumidifier easily.
. in ) 1 20 c m 3 (
. in m) 1 20 c (3
Choosing the proper location for the unit 1. Use the unit in a basement to help prevent moisture damage. 2. Use the unit in cooking, laundry, bathing, and dishwashing areas that have excessive moisture. 3. Use the unit to prevent moisture damage anywhere books or valuables are stored. 4. Place the unit where you want to have comfortable conditions.
List of components For models equipped with pump system: · 16 ft. (5 m) clear hose with Quick-Connect connection · 3 ft. (1 m) clear hose For all other models: · 3 ft. (1 m) clear hose Required tools and assembly time Collection tank: No assembly or plumbing necessary. Continuous draining outlet: To use the Continuous Draining feature the following tools will be necessary: · 1.5mm (0.2 in.) drill bit (to drill open the draining outlet) · Drill tool The estimated assembly time is 1-2 minutes. Pump system and Quick-Connect 16ft. hose (only on models equipped with pump system): No tools necessary. The estimated assembly time is 1-2 minutes.
7
ENGLISH
Disposing of the collected water
A) Empty the tank manually. When the tank is full, remove (fig.1) and empty it into a sink. When finished, replace it properly. NOTE: The tank must be positioned properly. If you hear the intermittent sound of the beep, it means the tank is not in the proper position.
fig. 1
B) Continuous draining. Condensed water can be drained via a hose connected to the outlet located in the lower part of the tank proceeding in the following way: 1. remove the water tank. 2. Using a 5 mm drill bit, (0.2 inches) drill a hole in the base of the tank along the torus as shown in figure 2. 3. Connect a hose to the hose connector (fig. 3). Be sure the hose does not kink or bend. Make sure that the hose is not higher than the hose connection (see figure 4). NOTE: When you remove the rubber cap keep it in a safe place in case you want drain into the tank. C) Continuous draining using the pump (only on pump models) The exclusive heavy-duty pump system allows water removal of up to 13.12 feet (4m) in height. If you want the water to flow directly to a drain, connect the condensation discharge tube supplied to the connection pipe located on the lower part of the unit (Fig. 5). Select the dehumidifying function and press the PUMP button.
Drill
fig. 2
fig. 3
Hose
fig. 4
Drain
Note: With the condensation discharge hose missing and the pump switched ON, the pump light will start blinking and the appliance will be in the stand-by position. To eliminate this problem insert the hose and switch the pump button ON. The condensation hose can be discharged into a drain. If you are using the heavy-duty pump function, the condensation hose can also be discharged through an open window.
1 PU
SH
2
fig. 5
8
Selecting the operations
Stand-by How
position
Once the power outlet is plugged in, the display will show on the left side the degree of humidity you want to reach (the default data is 60) and on the right side the display will show (for a minute) two dots, followed by the room humidity level.
to Select the Desired Humidity Level
1) Push the stand-by button. 2) Press the button to set the desired humidty level. (30% means a dry environment, 80% a humid environment). 3) Push the MODE button to choose the dehumidifying function; the function is selected when the small dot on the display is under the symbol). 4) When the appliance reaches the humidity set point the appliance will automatically stop working. As soon as the humidity increases above the set point, the appliance will automatically resume dehumidification operation. Note: The appliance is equipped with a safety device. The appliance only works after 3 minutes from the last time it was turned off.
How Turbo How
to use the FAN function
1) Push the stand-by button. 2) Push the MODE button to choose the FAN function; the function is selected when the small dot on the display is under the symbol). 3) Press the button to modify the ventilation speed (min/med/max).
power
1) Press the button. 2) The turbo power function is an automatic dehumidification function that is used when you wish to operate the appliance at maximum power. When in this mode, the display will show on the left side (two dots) and on the right side the room humidity present. To stop the turbo power function, simply press the button again.
to program the delayed start function: From the OFF Position
1) With the unit OFF, press the button and use the button to set the number of hours after which the appliance should start functioning. 2) On the left side the display will show the number of hours after which the appliance should start the operation (1-24h) and a small dot under the symbol indicates that the timer function has been selected. 3) When the selected time is reached, the appliance will start working.
9
ENGLISH
Selecting the operations
How
to Program the delayed stop function: From the ON Position
1) Press the button and use the + or - button to set the number of hours after which the appliance should stop functioning. 2) The left side the display will show the number of hours after which the appliance should stop the operation (1-24h) and a small dot under the symbol indicates that the timer function has been selected. 3) When the selected time is reached, the appliance will stop working.
10
· The safety device has been activated
Care and Maintenance
WARNING Electrical Shock Hazard Always disconnect power supply cord from outlet before performing any maintenance. Failure to follow the below precautions could result in the electrical shock or personal injuries.
Mai Cl
ntenance
Your d ... |
|||||||
| Know our Partners | Frequently Asked Questions | Contact Diplodocs team | Last searches Latest additions |
Sitemap | ![]() |
||||||||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |