Instruction Manual CON 11 & CON 110 Handheld Conductivity/TDS/Temperature/RS232C Meter 68X361303 Rev. 1 - 12/03 Technology Made Easy ... Preface This manual serves to explain the use of the CON 11/110 Conductivity/TDS handheld meters. It functions as a handy reference step by step guide to help you operate the meter. It is written to cover as many anticipated application of the CON 11/110 meters as possible. If there are doubts in the use of the meter, please do not hesitate to contact the nearest Authorised Distributor. Eutech Instruments / Oakton Instruments cannot accept any responsibility for damage or malfunction of the meter caused by improper use of the instruments. The information presented in this manual is subjected to change without notice as improvements are made, and does represent a commitment on the part of Eutech Instruments Pte Ltd / Oakton Instruments. Copyright © 2003 All rights reserved. Eutech Instruments Pte Ltd Oakton Instruments Rev 1 - 12/03 Table of Contents 1 2 INTRODUCTION ....................................................................................................................................... 1 DISPLAY AND KEYPAD FUNCTIONS.................................................................................................. 2 2.1 2.2 3 DISPLAY ............................................................................................................................................... 2 KEYPAD................................................................................................................................................ 3 PREPARATION.......................................................................................................................................... 5 3.1 3.2 3.3 3.4 3.4.1 3.5 3.6 3.6.1 INSERTING THE BATTERIES ................................................................................................................... 5 CONDUCTIVITY ELECTRODE INFORMATION.......................................................................................... 6 CONNECTING THE ELECTRODE TO THE METER ...................................................................................... 7 ATTACHING THE ELECTRODE HOLDER TO THE METER ......................................................................... 8 Inserting the electrode into the electrode holder ............................................................................. 8 CONNECTING THE AC/DC ADAPTER .................................................................................................... 9 CONNECTING THE RS232C CABLE (ONLY FOR CON 110) ................................................................... 9 RS232C Configuration .................................................................................................................. 10 4 CALIBRATION ........................................................................................................................................ 11 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.7.1 4.7.2 4.7.3 IMPORTANT INFORMATION ON METER CALIBRATION......................................................................... 11 PREPARING THE METER FOR CALIBRATION ........................................................................................ 12 TEMPERATURE CALIBRATION ............................................................................................................. 13 SELECTION OF AUTOMATIC OR MANUAL CALIBRATION..................................................................... 14 AUTOMATIC CALIBRATION (FOR CONDUCTIVITY CALIBRATION ONLY) ............................................ 15 MANUAL CALIBRATION (FOR CONDUCTIVITY & TDS CALIBRATION) ............................................... 17 TDS CALIBRATION ............................................................................................................................. 18 Calibrating for TDS Using Conductivity Standards & adjusting TDS factor ............................... 18 Setting the TDS Conversion Factor............................................................................................... 18 Calibrating for TDS using TDS standards .................................................................................... 19 5 MEASUREMENT ..................................................................................................................................... 20 5.1 5.2 5.2.1 5.3 5.3.1 5.3.2 5.4 5.4.1 5.5 AUTOMATIC TEMPERATURE COMPENSATION ..................................................................................... 20 MANUAL TEMPERATURE COMPENSATION .......................................................................................... 21 Setting the manual temperature compensation value.................................................................... 22 TAKING MEASUREMENTS ................................................................................................................... 23 Taking measurements with READY indicator selected on ............................................................ 23 Taking measurements with the Auto HOLD feature selected on ................................................... 23 USING MANUAL RANGING FUNCTION ................................................................................................ 24 Selecting manual range................................................................................................................. 24 HOLD FUNCTION ............................................................................................................................... 25 6 MEMORY FUNCTION............................................................................................................................ 26 6.1 6.2 MEMORY INPUT .................................................................................................................................. 26 MEMORY RECALL............................................................................................................................... 27 7 PRINT FUNCTION (FOR CON 110 ONLY) ......................................................................................... 28 7.1 USING CON 110 METER WITH PRINTER OR COMPUTER...................................................................... 28 7.2 SENDING DATA TO COMPUTER OR PRINTER ....................................................................................... 29 7.2.1 Printing Current Data Manually................................................................................................... 30 7.2.2 Print Data on Timed Interval ........................................................................................................ 30 7.2.3 Print Data from Stored Memory ................................................................................................... 32 8 ADVANCED SETUP FUNCTION .......................................................................................................... 34 8.1 ADVANCED SETUP MODE OVERVIEW............................................................................................... 36 8.2 P1.0: UNIT CONFIGURATION (COF).................................................................................................... 38 8.2.1 P1.1: Selection of READY and Auto HOLD function.................................................................... 38 8.2.2 P1.2: Selection of °C or °F ........................................................................................................... 39 8.2.3 P1.3: Selection of Automatic or Manual Temperature Compensation.......................................... 40 8.2.4 P1.4: Selection of TDS Conversion Factor ................................................................................... 41 8.3 P2.0: VIEWING CALIBRATION DATA .................................................................................................... 42 8.4 P3.0 VIEWING ELECTRODE DATA....................................................................................................... 43 8.5 P4.0: AUTO OFF.................................................................................................................................. 44 8.6 P5.0: RESET TO FACTORY DEFAULTS .................................................................................................. 45 8.6.1 P5.1: Calibration Reset................................................................................................................. 45 8.6.2 P5.2: User Reset............................................................................................................................ 46 8.7 P6.0: MEMORY CLEAR........................................................................................................................ 47 8.8 P7.0: TEMPERATURE........................................................................................................................... 48 8.8.1 P7.1: Setting the temperature coefficient ...................................................................................... 48 8.8.2 P7.2: Setting the normalisation temperature ................................................................................ 49 8.9 P8.0: SELECTION OF CELL CONSTANT ................................................................................................. 50 8.10 P9.0: AUTOMATIC AND SINGLE POINT CALIBRATION ......................................................................... 51 8.10.1 P9.1: Selection of Automatic or Manual Calibration............................................................... 51 8.10.2 P9.2: Selection of Single or Multi Point Calibration ............................................................... 52 9 CYBERCOMM PORTABLE DAS (FOR CON 110 ONLY)................................................................. 53 9.1 9.2 9.3 9.3.1 9.3.2 9.3.3 9.4 9.5 10 11 12 13 SYSTEM REQUIREMENTS..................................................................................................................... 53 LOADING CYBERCOMM PORTABLE DAS............................................................................................ 53 RUNNING CYBERCOMM PORTABLE .................................................................................................... 59 Buttons & Check-Box .................................................................................................................... 60 Menu.............................................................................................................................................. 61 Communication Settings................................................................................................................ 62 CAPTURING AND PRINTING DATA INTO COMPUTER USING DATA ACQUISITION................................ 63 TROUBLE-SHOOTING GUIDE ............................................................................................................... 64 ELECTRODE CARE AND MAINTENANCE....................................................................................... 65 ERROR MESSAGES................................................................................................................................ 66 TROUBLE SHOOTING........................................................................................................................... 67 LIST OF ACCESSORIES ........................................................................................................................ 68 13.1 13.2 REPLACEMENT METER AND METER ACCESSORIES.............................................................................. 68 CALIBRATION SOLUTIONS .................................................................................................................. 68 14 FACTORY DEFAULT SETTINGS ........................................................................................................ 69 14.1 14.2 CON 11 FACTORY DEFAULT SETTING................................................................................................ 69 CON 110 FACTORY DEFAULT SETTING.............................................................................................. 70 15 16 17 18 19 20 SPECIFICATIONS ................................................................................................................................... 71 CALIBRATION TIPS............................................................................................................................... 73 CALCULATING TDS CONVERSION FACTORS............................................................................... 73 CALCULATING TEMPERATURE COEFFICIENTS ........................................................................ 74 WARRANTY ............................................................................................................................................. 75 RETURN OF ITEMS............................................................................................. ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.