9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your EUTECH INSTRUMENTS CYBERSCAN PH 5000 PH METER : user manual, user guide, instruction manual.
Search a brand
Advanced Search

User manual EUTECH INSTRUMENTS CYBERSCAN PH 5000 PH METER

Diplodocs help download the user guide EUTECH INSTRUMENTS CYBERSCAN PH 5000 PH METER .

Download the complete user guide (2460 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide EUTECH INSTRUMENTS CYBERSCAN PH 5000 PH METER

Detailed instructions for use are in the User's Guide.

Instruction Manual CyberScan pH 5500/ 5000 Bench pH & Ion Meter/ Bench pH Meter Technology Made Easy ... 68X292328 Rev. 1 07/03 PREFACE Thank you for selecting the Eutech Instruments this CyberScan Series 5000 bench meter. This meter measures pH, mV and ion (Ion measurement available in CyberScan pH5500 only). The instruction manual serves to explain the use of the CyberScan Series 5000 bench meters as a step-by-step operational guide to help you familiarize with the meter's features and functions. It is structured sequentially with illustration of diagrams that explains the various functions and setup menus available. This manual is written to cover as many anticipated applications and uses of the CyberScan Series 5000 bench meters as possible. If there are doubts in the use of the meter, please do not hesitate to contact the nearest Eutech Instruments' Authorized Distributors or call us at (65) 6778-6876 for Eutech Instruments' Customer Service Dept. for assistance. Kindly remember to complete the warranty card and mail it back to your Authorized Distributors or Eutech Instruments Pte Ltd. Eutech Instruments reserve the rights to change, make improvement and modify specifications without prior notice and cannot accept any responsibility for damage or malfunction to the instrument caused by improper use. Copyright 2002 Eutech Instruments Pte Ltd All rights reserved. Rev. 1 07/03 © Instruction Manual CyberScan pH5500/ 5000 TABLE OF CONTENTS 1 2 3 INTRODUCTION 1.1 Introducing the CyberScan Series 5000 UNPACKING THE METER GETTING STARTED 3.1 3.2 4 4.1 4.2 4.3 5 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 5.10 5.11 5.12 5.13 5.14 5.15 6 6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 6.9 6.10 6.11 6.12 6.13 6.14 6.15 6.16 7 7.1 7.2 8 8.1 8.2 8.3 8.4 8.5 9 9.1 9.2 10.1 Connectors pH Electrodes & Ion Specific Electrodes Touch screen Operation Choosing a Channel (For CyberScan pH5500 only) Button Functions Access System Setup Select Language Set Date Set Time Set Beeper Status Select Procedural Level Set Print Configuration Set Baud Rate Set Number of Bits Set Stop Bits Set Parity Set Operator Set Display Contrast Display Meter Information Reset to Factory Defaults Access pH setup Set Sample ID# Select Buffer Group Set pH Custom Buffer Group Select Buffer Recognition Select Auto Read Mode Set pH Stability Criteria Set Default Temperature Set Isopotential Point Set Alarm Limits Set Print Criteria Set Print Interval Set Data Storage Criteria Set Display Resolution Set Display Configuration View Stored Data Access mV Setup Set Display Resolution Access Ion Setup Select Ion Method Select Measurement Units Select Electrode Type Set Significant Digits Standardizing pH Measurements mV Measurement 1 1 2 3 3 5 7 8 9 11 13 14 16 18 20 22 24 26 28 29 30 31 32 34 36 37 38 39 41 45 47 49 50 51 53 55 57 59 61 63 65 67 69 73 74 78 80 81 83 85 87 89 91 93 97 99 100 USING THE METER SYSTEM SETUP pH SETUP mV SETUP ION SETUP pH OPERATION 10 mV OPERATION Instruction Manual CyberScan pH5500/ 5000 11 ION OPERATION 11.1 11.2 11.3 11.4 11.5 11.6 Direct Reading Methods Incremental Methods Known Addition Method Known Subtraction Method Analate addition Analate Subtraction 101 103 109 111 115 117 119 121 122 123 124 124 125 126 128 133 137 139 139 140 141 142 142 143 12 CLEANING 13 TROUBLE SHOOTING 14 COMPLIANCE 15 APPENDIX 15.1 15.2 15.3 15.4 15.5 Determining Isopotential Points Experimentally Data Management Factory Default Settings pH Theory ISE Theory 16 METER SPECIFICATIONS 17 ACCESSORIES 17.1 17.2 17.3 17.4 17.5 Replacement Meters and Adapters General Purpose pH / ORP Electrodes SP Specialty pH Electrode NP pH Buffer Solutions & Single Use Sachets SP ORP Solutions SP 18 WARRANTY Instruction Manual CyberScan pH5500/ 5000 1 INTRODUCTION 1.1 Introducing the CyberScan Series 5000 Thank you for selecting a Eutech Instruments CyberScan Bench meter. This manual describes the operation of the CyberScan Series 5000 bench meters. The state-of-art meter that you have purchased is easy to operate and will guide you through the various functions by displaying easy to understand prompts. This instruction manual should answer any questions that might arise in operating your meter, however, do not hesitate to call our Technical Support at (65) 67786876 (ext 837) or fax at (65) 67730836. This bench meter provides microprocessor precision in a compact benchtop design that is easy to use. One touch screen controls all procedures, letting you: Measure pH, absolute mV, relative mV , ion concentration (CyberScan pH5500 only) Select one of three sets of standard buffer groups Implement automatic buffer recognition Standardize with up to five standard or customer buffers Customise your display screen and operating parameters Assign operator and sample identification numbers Store 250 data points in the meter's memory or transfer data to a computer or printer. Access extensive online help with just a touch a button It all adds up to rapid, completely automatic, intuitive operation. You will find this symbol appearing in this manual; it indicates useful tips that ease your meter operation. 1 Instruction Manual CyberScan pH5500/ 5000 2 UNPACKING THE METER The following is a listing of what you should have received with your new CyberScan meter. Meter package includes Meter Power adapter (120 VAC/ 12VDC) OR (220 VAC/ 12 VDC) depending on order code. Electrode arm support bracket Electrode arm ATC probe Instruction Manual If any of these items are missing, please contact your nearest Authorized Distributor. Accessory conductivity probes and ion selective electrodes are available and can be ordered by contacting any Authorized Distributor or Eutech Instruments Marketing (65) 67786876. 2 Instruction Manual CyberScan pH5500/ 5000 3 GETTING STARTED 3.1 Connectors 1. Review the layout and arrangement of the rear connector panel. 3 Instruction Manual CyberScan pH5500/ 5000 2. Connect the electrode arm to the base. 3. Connect the power cable to the connector cable to the rear connector panel power jack and to a power source. To connect RS232, see Data Management on Section 15.2. 4 Instruction Manual CyberScan pH5500/ 5000 3.2 pH Electrodes & Ion Specific Electrodes (Ion Specific Electrode applicable for CyberScan pH5500 only) This meter allows you to use two types of pH electrodes: the conventional glass pH electrode and the field effect transistor (FET) pH electrode. If both types of pH electrodes are connected, the meter will read the FET electrode. 1. Carefully remove the protective cover from the end of the electrode. Before first using your glass pH electrode, soak it 2-4 hours in an electrode storage solution, pH 4 buffer, or KCI solution. 2. Remove the shorting cap on BNC connector. Connect the combination pH electrode in to the BNC input connector. If a combination electrode is not used, connect the indicating pH electrode into the BNC input connector. Plug the reference electrode into the reference pin jack. Also, install the ATC probe into the ATC jack. Note: Be sure to connect all probes to the appropriate channel connectors (for example: Input 1, Ref 1 and ATC1). 5 Instruction Manual CyberScan pH5500/ 5000 Option: Connect the optional FET electrode by plugging it into the FET jack on the back meter panel. Allow the FET electrode to warm up five minutes before use. Connect ion specific electrodes in the same manner as pH electrodes. If both a conventional and a FET electrode are connected to the meter, do not put them in a solution together because you will get inaccurate measurements. Do not discard the BNC shorting cap. 3. Rinse and blot-dry (do not wipe) electrodes between each measurement. Rinse electrodes with distilled or deionized water, or a portion of the next solution to be measured. 4. Between measurements, store conventional pH electrodes storage solution, pH 4 buffer, or KCI solution. Always leave the filling hole of liquid filled combination electrodes open. Refill when the level of solution gets below the manufacturer's recommended level. Proper electrode care is fundamental to obtaining reliable pH measurements. Improper care of the electrode may cause the meter reading to drift, respond slowly, or produce erroneous readings. For this reason, the electrode should always be conditional and used in accordance with manufacturer's instructions. 6 Instruction Manual CyberScan pH5500/ 5000 4 USING THE METER EUTECH INSTRUMENTS 11:11 am Touch anywhere to resume 7 Instruction Manual CyberScan pH5500/ 5000 4.1 Touch screen Operation This new CyberScan research benchtop meter operates with a state of art touch screen. The touch screen makes this the easiest meter on the market to operate and care for. When this meter is first plugged in, the STANDBY screen will appear. Touch anywhere on this screen to access the functions of the meter. The buttons on the right side of the screen control all of the functions of the meter. Alight touch on the screen is all you need to access the various functions. Once you touch a button you will get an audible tone; the screen will not change until you lift your finger. This design prevents rapid uncontrolled scrolling through the various function screens. Easy to understand prompts guide you through the operation of the meter in the selected mode. If you are ever in doubt about what to do, just touch help on the bottom right corner of the screen for detailed information about the screen. The touch screen is made of a durable polyester material that is chemically resistant. Maintenance is simple with this meter. To clean the screen you just need to wipe it with a damp cloth and dry it with a clean dry towel. For additional information, see Cleaning and Troubleshooting sections of the manual. (Pg 121-122) 8 Instruction Manual CyberScan pH5500/ 5000 4.2 Choosing a Channel (For CyberScan pH5500 only) Main Screen Channel Screen EUTECH INSTRUMENTS CyberScan pH 5500 pH EUTECH INSTRUMENTS 1 mV CyberScan pH 5500 2 Ion dual Select from the options to the right Select from the options to the right setup January 15, 2002 11:11 am January 15, 2002 11:11 am Measure pH channel 1 1 9.295 ID# auto buffer 00000 ON ATC slope mV 25.0°C 000.0% 0000.0 2 Buffers Last std: Jan 15 @ 11:11 am January 15, 2002 11:11 am abs mV channel 2 177.0 ID# 00000 defualt 25.0°C Dual Screen 9 Instruction Manual CyberScan pH5500/ 5000 The CyberScan pH5500 is a multi-channel meter. With this meter you can switch from channel 1 to channel 2. You can also view both channels at the same time by accessing the dual channel mode. If you set the meter to view both channels, you cannot change the parameters without choosing the screen that you want to modify. The setup parameters for each screen independently of one another. Choosing a channel 1. Touch anywhere on the standby screen. OR Touch channel on the main screen THEN 2. Touch 1, 2 or dual to access the channel that you want to view. To access System Setup from the standby screen 1. Touch anywhere on the standby screen. 2. Touch 1, 2 or dual to access the channel that you want to view. 3. Touch setup. 4. Touch system on the setup screen. If you are in any measure mode, touch mode until you access the main screen. 10 Instruction Manual CyberScan pH5500/ 5000 4.3 Button Functions The touch screen of your CyberScan bench meter has "buttons" along the right side of the screen that are common to many of the screens. The following indicates the function of these common buttons. This is the standby button and it allows you to access the standby mode. When in standby, the meter will not take measurements. It is in a state of rest. When you touch stdby the meter will return to the standby screen which says "Eutech Instruments" and displays the time. This button allows you to access the channel screen to choose what channel you want to view. This button appears only on multi-channel meter such as CyberScan pH5500. This button also allows you to move from the main mode to the channel screen to access the standby mode. The mode button allows you to switch between the various operations of the meter. These operations, depending upon which meter you have, include four measuring modes (pH, mV, ion) as well as a setup mode. mode enter The enter button allows you to accept any changes that you have made on one setup screens or accept values that you have input with keypads. When touched, enter will save the changes and return you to the previous screen. save The save button allows you to save multiple changes that you have made on one screen as a group. It functions like the enter button does for an individual changes. The exit button allows you to leave the screen you are currently viewing and return to the previous screen without making any changes. The help button allows you to access helpful information on any screen. When you touch the help button, information about th ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.