Manual abstract: user guide EUTECH INSTRUMENTS WATERPROOF PHTESTR 2 PH TESTER

Detailed instructions for use are in the User's Guide.

Instruction Sheet Microprocessor based, pH Tester 2 with ATC that floats! Waterproof pHTestr 2 Microprocessor-based Pocket pH Tester BEFORE USE: DO NOT BE ALARMED if white crystals form around the cap. This is normal. CONDITIONING: Condition the unit before first use. Remove cap, immerse electrode in tap water for 1 hour. This activates electrode and dissolves crystals. CALIBRATION: This tester allows up to 3-point calibration. Star t with pH 7 buffer. Press ON/OFF button to power on. Immerse electrode in chosen buffer about 2 cm deep and stir gently. Wait for displayed value to stabilize at or near the pH buffer chosen. Next, press the CAL button to enter calibration sequence. When display flashes continuously, press HOLD/CON button to confirm. If necessary, proceed to next buffer value (pH 4 or pH 10) and repeat the calibration procedure. You have successfully calibrated the instrument. pH TESTING: · Remove cap and press ON/OFF button on the keypad to turn on the pHTestr 2 · Dip the electrode about 2 cm into the test solution · Stir once, let the display stabilize. Note the pH · Press HOLD/CON button if you wish to hold the reading. Press again to release · Press the ON/OFF button to shut off · Tester automatically shuts-off after 8.5 minutes to conserve batteries! MAINTENANCE IS EASY: Rinse the electrode in tap water after use. In harsh samples, take readings quickly, rinse electrode immediately afterwards with tap water to remove residues and prevent electrode contamination. To maximize electrode life, place a small piece of clean cloth or sponge in the cap, moisten with tap water (NOT DE-IONIZED WATER), and replace cap. CHANGING BATTERIES: Twist open the batter y compar tment lid. Remove old batteries and replace with fresh ones noting polarity as shown in battery compartment. Re-calibrate after battery change. Keypad USEFUL NOTE: · To avoid cross contamination, rinse between samples and buffer with tap water · Calibration should be done regularly or daily to ensure good tester accuracy. ERROR MESSAGES: E1 - Weak batteries. Need replacement. E2 - Wrong or bad buffer value (out of range) or the electrode is failing. OR - Over range signal or electrode is not in contact with sample solution. 68X247717 2/05 Rev 5 (Picture A) REMOVE THE OLD ELECTRODE Rotate collar away from you Rubber Gripper Band Ribbed Collar Twist-off Battery Compartment Amplified Electrode REPLACE THE ELECTRODE Small O-Ring Large O-Ring (Hidden) Replacement Electrode (Picture B) Lanyard Connection Insert Electrode Small Tabs Large Tab Replaceable Sensor SPECIFICATIONS Model pHTestr 1, 2 pH Range -1.0 to 15.0 pH Resolution 0.1 pH Accuracy pHTestr 1 : ± 0.2 pH pHTestr 2 : ± 0.1 pH ATC Yes (Except pHTestr 1) Calibration pHTestr 1 : 1-point (4.0, 7.0 or 10.0) pHTestr 2 : 3-point (4.0, 7.0 & 10.0) Auto Power- Yes Off/Hold Auto-Buffer Yes (pH 4, 7, & 10) Recognition Battery Life 3 x 1.4V (Type: A 76, LR44, V13GA) ; >60 hours Dimension/ Tester : 15 x 3.8 cm ; 90g Weight Boxed : 18.5 x 7 x 5 cm ; 170g Eutech Instruments Oakton Instruments www.eutechinst.com www.4oakton.com Made in Malaysia 68X247809 2/05 Rev 3 ELECTRODE REPLACEMENT: One of the benefits in selecting the Waterproof pH tester is that you can now replace the electrode whenever needed keeping the body of the tester intact. When the tester fails to calibrate, gives fluctuating readings in buffers, or shows error messages `E2' or `OR' in a buffer, and the procedures in the maintenance section do not help, you need to change the electrode (see pictures for instructions).· With dry hands firmly grip the ribbed collar (Picture A) and slowly twist the body counter clockwise until it is completely removed. Save both the electrode module collar and O-ring inside for later use. Pull the old electrode module straight out from the bottom of the tester · Align the four tabs on the new module so they match the four slots on the tester (Picture B). Note: Older testers may have only two slots. In this case, break off the two small tabs using a needle-nose pliers · Gently push the module onto the bottom end to fully seat it in position. Put the small Oring all the way into the ribbed collar. Then push the collar on over the module and hand-tighten by firmly twisting it clockwise. ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.