Detailed instructions for use are in the User's Guide.
INSTRUCTION MANUAL VACUUM CLEANER
FM760
Contents
IMPORTANT SAFETY INSTRUCTIONS NAME OF EACH PART PREPARATION BEFORE USE USING THE VACUUM CLEANER USING THE ATTACHMENTS EMPTYING THE DUST COMPARTMENT CLEANING THE FILTERS CLEARING BLOCKAGES IN THE SUCTION HOSE AND CLEANING THE AGITATOR ASSEMBLY REPLACEMENT INSTRUCTIONS TROUBLESHOOTING REPLACEMENT PARTS LIMITED WARRANTY 1 3 4 6 8 9 10 11 12 16 16 17
HOUSEHOLD USE ONLY
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical appliance, basic precautions should always be followed, including the following. READ ALL INSTRUCTIONS BEFORE USING THIS VACUUM CLEANER
WARNING - To reduce the risk of fire, electric shock or injury:
1. Do not leave the vacuum cleaner when plugged in. Unplug it from the outlet when not in use and before servicing. 2. Do not use outdoors or on wet surfaces. 3. Do not allow it to be used as a toy. Close attention is necessary when used by or near children or infirmed persons. 4. Use only as described in this manual. Use only the manufacturer's recommended attachments. 5. Do not use with a damaged cord or plug. If the vacuum cleaner is not working as it should, or if it has been dropped, damaged, left outdoors or dropped into water, return to FANTOM at 94 Main Mill street, Door 16, Plattsburgh,
NY 12901. 6. Do not pull or carry by the cord, use the cord as a handle, close a door on the cord, or pull the cord around sharp edges or corners. Do not run the vacuum cleaner over the cord. Keep the cord away from heated surfaces. 7. Do not unplug by pulling on the cord. To unplug, grasp the plug, not the cord. 8. Do not handle the plug or the vacuum cleaner with wet hands. 9. Do not put any objects into the openings. Do not use with any opening blocked: keep free of dust, lint, hair and anything that may reduce air flow. 10. Keep hair, loose clothing, fingers and all the parts of your body away from openings and moving parts. 11. Do not pick up anything that is burning or smoking, such as cigarettes, matches or hot ashes. 12. Do not use without dust compartment and filters in place. 13. Turn off all controls before unplugging. 14. Use extra care when cleaning on stairs. 15. Do not use to pick up flammable or combustible liquids such as gasoline, or use in areas where they may be present.
1
REV. 05/02B
16. Do not touch the agitator while it is spinning. 17. Do not place any heavy items on top of the vacuum cleaner. 18. Do not step on the hose or pull it too strongly. 19. Do not pick up items such as pieces of waste paper or cloth which look as though they may cause the hose to become blocked. 20. Do not clean or store the vacuum cleaner in places where there are high temperatures. 21. Store the vacuum cleaner away from excessive humidity. 22. When carrying the vacuum cleaner, hold it by the carrying handle. 23. Before servicing the vacuum cleaner, allow all metal parts to cool first. 24. Always place foot on handle release when adjusting the handle position of the vacuum cleaner. 25. If the supply cord of this appliance is damaged, it must only be replaced by FANTOM , because special purpose tools are required.
SAVE THESE INSTRUCTIONS
This vacuum cleaner is intended for household use only.
Note to user concerning attachment plug:
To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.
2
NAME OF EACH PART
FRONT REAR
Handle
Release Button C
Suction Hose Release Button A Cord Storage Hooks Release Button B
Carrying Handle
ON/OFF Switch Crevice Tool Release Button D Upholstery Tool
Dust Compartment Dusting Brush
Filter Cover Wand
Power Cord Power Cord Plug Height Adjustment Headlight Lever Handle Release Lever Set the ON/OFF switch to " ON " to light the headlight.
Rug/Floor (Tools) SELECTOR
Cleaning Utensil
Operate vacuum cleaner only at the voltage specified on name plate.
3
PREPARATION BEFORE USE
Caution: Do not connect the power cord plug to the wall outlet until assembly is completed.
Attaching the handle
Set the vacuum cleaner 1 to the upright position. lnsert the 2 as shown handleillustration. in the
Attaching the suction hose & attachments
Wand
Suction Hose
Crevice Tool
Hose Hook Upholstery Tool
Dusting Brush
4
PREPARATION BEFORE USE
WINDING THE POWER CORD
Hook the power cord over 1 the clip which is located on the upper cord storage hook as shown.
Plug side
Wind the power 2 storage hooks. cord around the cord
Secure the power cord plug on the power cord.
Cord Storage Hooks
Clip
RELEASING THE POWER CORD
Rotate the 1 downward.upper cord storage hook to the 2 Return the hook before upright position attempting to rewind the power cord. Upper Cord Storage Hook
INSERTING THE POWER CORD PLUG
WARNING: To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not modify the plug in any way.
5
USING THE VACUUM CLEANER
ON/OFF SWITCH
Start or stop vacuum cleaner by pushing on the switch.
ADJUSTING THE HANDLE
The handle of this vacuum cleaner can be set to one of three positions -Upright, Normal or Parallel. Place your foot on handle release lever as shown and pull back on the handle until it releases from its upright position.
Handle Release Lever
Upright position
The handle is normally locked in this position for storage or when using the attachments. Push the handle forward until it locks.
Normal position
This position is used for normal cleaning.
Parallel position
Handle Release Lever
This position is used for cleaning under furniture.
6
USING THE VACUUM CLEANER
HEIGHT ADJU STMENT LEVE R
Cautio n:
Height Adjustment Lever The nozzle head can be adjusted to four different height settings.
Before using the height adjustment lever,please make sure the nozzle head is tilted backward from the floor.
Nozzle Head
Set the height adjustment to the appropriate carpet length. Use the 3 rd( setting. Use the 4 th( setting. )height
)heigh t
RUG/FLOOR (TOOLS)SELECTOR
The RUG/FLOOR(TOOLS)selector should only be adjusted while the vacuum cleaner is turned on RUG Position and in the upright position. When cleaning a rug or carpet,first turn the ON/OFF switch to the ON position,and then set the RUG/FLOOR(TOOLS)selector to the RUG position.
FLOOR Position
1
2 When cleaning a bare floor or when using one of the attachments, set the RUG/FLOOR
EDGE CLE AN ING
RUG/FLOOR(TOOLS)selector (TOOLS)selector to the FLOOR position. Caution: Do not change the setting of the RUG/FLOOR(TOOLS)selector while the vacuum cleaner is turned off.
This vacuum cleaner is equipped with an "edge cleaning" function for cleaning carpet edges near baseboards and stationary furniture.
7
USING THE ATTACHMENTS
Caution: When using one of the attachments during cleaning,set the vacuum cleaner to the upright position.
the attachments from the 1 Removecleaner. vacuum 2 Press the release button C to disconnect the handle from the vacuum cleaner.
Wand Crevice Tool
Release Button C
Caution: When removing the attachments,pull them in the directions shown in the Upholstery Tool illustration.Pulling them in the wrong direction or pulling them forcefully may cause damage to the attachment clamp .
Dusting Brush Attachment Clamp
3 Attach the attachments on the handle.
Attach the attachments as shown below.
Wand Crevice Tool
Upholstery Tool Suction Hose Dusting Brush
When you have finished using the attachments,replace them in their original positions as shown on page 4.
8
EMPTYING THE DUST COMPARTMENT
Caution: Be sure to turn the ON/OFF switch to the "OFF" position and disconnect the power cord from the wall outlet before cleaning.
1
Empty the dust compartment when contents reach the MAX mark.
2
Press the release button A meanwhile press the release button B to remove the dust compartment. Release Button A Release Button B
MAX mark
3
3
Press the release lever to open the trapdoor. Release Lever
Turn the handle 4 direction spinnerto emptyseveral times in the shown the dust compartment.
Trapdoor Spinner Handle
Reattaching the Dust Compartment
Close the trapdoor and insert the the dust 1 dust compartment into the grooveprojection onbody. 2 Push the body compartment into on the main the main as shown to reattach.
Projection Groove
9
CLEANING THE FILTERS 1 Remove the dust compartment.(refer to page 9) Set the dust compartment to the 2 position.Open the trapdoor,then parallel push the
release button E and pull out the main filter. The main filter and prefilter will be removed at the same time. Caution: Do not push the release button E at the upright position. As this may drop or damage the main filter and prefilter. the and prefilter with 3 Clean bothmain filterdry completely. a soft-bristled brush and rinse with cold water. Allow items to Caution: Do not use a hard-bristled brush to clean filters. This may result in damage to the filters. Do not attempt to dry with a hair dryer or by placing in a clothes dryer.Hot air may cause the filters to warp. Release Button E
Cleaning Utensil
To maintain optimum suction power, the dust filter fins should be kept clean of dirt. Clean the filter fins free of dirt with the forked end of cleaning utensil as shown.
Cleaning Utensil
Reattaching the filters
1 Insert the main filter into the prefilter as shown.
Prefilter
onto the main filter 2 Holddust compartment. and insert into the Align the ribs of the main filter to match the shape of the opening in the dust compartment and press firmly to insert.
Dust Compartment
Hole
Main Filter
Ribs
3 Close the trapdoor.
10
CLEARING BLOCKAGES IN THE SUCTION HOSE AND CLEANING THE AGITATOR ASSEMBLY
Caution: Be sure to turn the ON/OFF switch to the "OFF" position and disconnect the power cord from the wall outlet before clearing any blockages in the suction hose and cleaning the agitator assembly.
Clearing blockages in the suction hose
Set the 1 Removevacuum cleaner to the upright position. the cuff from any from the hose. 2 then remove hoseblockagesthe suction inlet and Pull inspection cover out the bypass tube assembly. 3 pushthe dust dust clogging theaway from body and cuff to inlet,and dust inspection cover to the bypass tube assembly. 4 Reattach theonhose vacuum the suctioncheck that the Now switch the cleaner to
Hose Cuff
Suction Inlet Dust Inspection Cover Bypass Tube Assembly
the blockage has been properly cleared. If the hose is still blocked, the suction force will be weak.
Clearing blockages in the nozzle head
Remove the bottom plate (refer to page 14) Remove any blockages from the nozzle head. Reattach the bottom plate to the nozzle head,and then operate the vacuum cleaner to check that the blockage has been properly cleared. If the nozzle head is still blocked, the suction force will be weak.
Nozzle Head
Cleaning the blockage in the nozzle air inlet pipe
If the nozzle head still appears to be blocked, please clear the blockage in the nozzle air inlet pipe. Press release button F to remove the upper case. Remove the blockage in the nozzle air inlet pipe. Reattach the vacuum cleaner.
Release Button F Release Button F
Nozzle air inlet pipe Nozzle air inlet pipe
Caution: Make sure that the Release Button F is at the original position.
Cleaning the agitator assembly
When threads get caught in the agitator assembly, clean the assembly. Remove the bottom plate (refer to page 14). Remove threads caught in the assembly by cutting them with scissors. Scissors Threads
11
REPLACEMENT INSTRUCTIONS
Caution: Be sure to turn the ON/OFF switch to the"OFF" position and disconnect the power cord from the wall outlet before replacing any of the parts below.
REPLACING THE HEADLIGHT LAMP
1
Set the vacuum cleaner to the parallel position.
2 Loosen the screws to remove the lens. 3
When removing the headlight lamp, be careful not to pull on the headlight lamp wiring. Lens
Headlight Lamp
Screw
4
Remove the lamp by pushing it gently in the direction of the arrow and then turning it counterclockwise. Lamp
Socket
5
Push a new lamp gently into the socket and turn it clockwise to tighten it . Use a standard bayonet base appliance lamp rated at 120V and 15W (LAMP MAX.15W).
Socket
Caution: Be careful not to clamp the headlight lamp wiring.
6 Reattach
the lens and fasten the screws.
12
REPLACEMENT INSTRUCTIONS
Caution: Be sure to turn the ON/OFF switch to the"OFF" position and disconnect the power cord from the wall outlet before replacing any of the parts below.
REPLACING THE FLAT BELT
1 2
Remove the bottom plate. (refer to page 14) Lift out the agita ...