Download user guide, user manual, owner manual and instructions guide
5 600 brands
1 870 000 user's guides
Search a brand
Advanced Search



Our partners wish to propose you the following products


User manual FARLIGHT CMI SERIES IIX

Diplodocs help download the user guide FARLIGHT CMI SERIES IIX.



Download the user manual FARLIGHT CMI SERIES IIX  
Download the complete
user guide (15 Ko)
Need help, support, reviews, tips or troubleshooting for your FARLIGHT CMI SERIES IIX products ?

Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
User guide FARLIGHT CMI SERIES IIX

Detailed instructions for use are in the User's Guide.

C M I Series IIX Software Release - Revision 19 Several new features have been added to release version 19. * Page I General Interface MIDI configuration setup can be saved as a preset file on disk. * Page 2 and L display the new Page I MIDI configuration file. * Page 7 Control Parameters allows patching KEY NUMber to FILTER~. Filter response can be further modified by a function curve. * Page S Screen Print has selectable Baud rate, and keyboard commands to toggle Auto Form Feed and Inversion. Page 1 C M I Series IIX Software Release - Revision 19 (continued) PAGE I Page I MIDI setup can be saved to disk as a .MC file allowing instant recall of complex MIDI patches. Some SMPTE parameters are saved also. These are: time code reader frame rate time code generator frame rate drop frame switch rate jam sync switch rate. To save a MIDI setup, type SAVE FILENAME.MC When the file has been saved, its name will appcar in the CFG: box at the bottom lefthand of screen. Note that you must type the .MC part of the filename. Otherwise, it will be assumed that filenameis a voice and will probably display the error message FILENAME NOT LOADED. To load a previously saved MIDI file, type LOAD FILENAME.MC The filename will appear in the CFG: box as previously described. Whenever you load a .MC file, it will turn off the time code reader and generator. To reset Page I, save the default (normal) setting as a file. Thcn, later on, loud that same file when you want to reset Page 1. Page I MIDI configuration files (ending in.MC) can only be loaded or saved from Page I. Page 2 and Page L can display files with the .MC suffix. Page 2 C M I Series IIX Software Release - Revision 19 (continued) PAGE 7 KEYNUM (music key number) can be patched to FILTER with a function curve. By drawing a function curve on Page F, with the appropriate patch on Page 7, filter cutoff response can vary depending on which note you play on the music keyboard. This is useful for filtering shrill high notes of a voice while leaving the low notes unaffectod, or for simulating a formant of an instrument. To patch KEYNUM with function to filter, move cursor to FILTER= and type KEYNUM, X where X is a function Ictter betwecn A and P. Now, on Page F, select the corresponding function letter, eithcr by pointing the lightpen at the function lettcr or by typing D,X where D means draw and X is the function letter When used with KEYNUM, the left side of Page F graph corresponds to the low end of the music keyboard, the right side corrcsponds to the high end. The most noticeable effect on filter would be to draw a diagonal line with the lightpen from the top left of the graph to the bottom right Now play the music keyboard. Notice how the sound becomes more filtered as you play higher. This function curve and the Page 7 patch can be saved on Page 7 by typing S CO PAGE S Page S - Scrcen print has a baud rate selector which affects the data transmission rate at the printer output on the rear of the CMI. This allows you to use the older slower printers which may have a fixed rate of, for example, 300 Baud. If the Baud setting on Page S does not match that of the printer, garbage will result. To set baud rate, move cursor to BAUD RATE and type n where n = 9600, 7200, 4800, 3600, 2400, 1800, 1200, 600, 300 or 150. Protocol is: RS232C, start bit, 8 data bits, stop bit, no parity. NOTE: Baud rate selection also affects tEc Pagc C - MCL baud rate. The AUTO FF and INVERT fonctions on Page S can now be switched ON or OFF by kcyboard command. Type A to switch AUTO Form Feed eithcr on or off. Type I to switch INVERT function either on or off. Version lundi 4 janvier 1999 Page 3

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FARLIGHT CMI SERIES IIX.

FARLIGHT offer a product for which we do not have the user manual? Let us know what you are looking for: site Internet, histoire, actualité, filiales, site Internet, mode d'emploi, driver, avis des utilisateurs, meilleur prix des produits, forum d'assistance aux problèmes, annuaire des marques, annuaire des constructeurs, répertoire des marques, répertoire des constructeurs, site Internet de la marque, site Internet du constructeur

Diplodocs allows you to download user manual FARLIGHT CMI SERIES IIX, user guide FARLIGHT CMI SERIES IIX, instructions FARLIGHT CMI SERIES IIX, owner's manual FARLIGHT CMI SERIES IIX, online manual FARLIGHT CMI SERIES IIX.


Access web reviews FARLIGHT CMI SERIES IIX, ,
Include the add-on to download manuals from your site, forum or blog Frequently Asked Questions Contact Diplodocs team Last searches
Last additions
Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.