9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your FBII OMNI-624EU : user manual, user guide, instruction manual.
Search a brand
Advanced Search

Need help using a product?
Look at the reviews on FBII OMNI-624EU

User manual FBII OMNI-624EU

Diplodocs help download the user guide FBII OMNI-624EU .

Download the complete user guide (835 Ko)




You may also download the following manuals related to this product:
FBII OMNI-624EU AUTRE NOTICE


Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide FBII OMNI-624EU

Detailed instructions for use are in the User's Guide.

+DUGZLUHG:LUHOHVV6\VWHP OMNI-624 OMNI-624EU User Guide ARMED READY STAY 1 4 7 2 5 8 0 3 6 9 # BYPASS INSTANT ARMED READY STAY 1 4 7 2 5 8 0 3 6 9 # ARM AC / LB 1 4 7 2 5 8 0 3 6 9 # INSTANT CODE BYPASS INSTANT READY CODE STAY BYPASS STAY INST LO BATT SPRV. CODE N9968V1 3/01 Table of Contents QUICK REFERENCE.......................................................................................................................4 INTRODUCTION..............................................................................................................................6 SYSTEM REFERENCE ...................................................................................................................7 ZONE DESCRIPTIONS................................................................................................................7 SEND HELP ALERT.....................................................................................................................8 PAGER ALERT.............................................................................................................................8 MONITORING STATION INFORMATION ...................................................................................8 USER CODE ASSIGNMENTS .....................................................................................................9 ARMING THE SYSTEM.................................................................................................................10 IS THE SYSTEM READY? .........................................................................................................10 TO ARM THE SYSTEM AND LEAVE ........................................................................................10 WHEN THE SYSTEM IS NOT READY ......................................................................................11 TO ARM THE SYSTEM AND STAY INSIDE..............................................................................12 TO ARM THE SYSTEM IN INSTANT MODE AND STAY INSIDE.............................................12 TO ARM THE SYSTEM IN INSTANT MODE.............................................................................13 TO BYPASS A ZONE .................................................................................................................13 TO UNBYPASS A ZONE............................................................................................................14 DISARMING THE SYSTEM...........................................................................................................15 USER CODES................................................................................................................................16 TO ADD OR CHANGE A USER CODE .....................................................................................16 TO DELETE A USER CODE ......................................................................................................17 MISCELLANEOUS COMMANDS..................................................................................................18 TO SEND HELP ALERTS ..........................................................................................................18 DURESS .....................................................................................................................................18 QUICK ARMING .........................................................................................................................18 QUICK FORCED ARMING.........................................................................................................18 QUICK BYPASS .........................................................................................................................19 QUICK EXIT ...............................................................................................................................19 TO TURN CHIME ON/OFF.........................................................................................................19 ASSIGN USERS ACCESS TO OTHER PARTITIONS ..............................................................20 CHANGE PARTITION ................................................................................................................20 TO SET AUTO-ARM TIME .........................................................................................................20 -2- TO VIEW QUICK COMMAND LIST (LCD KEYPADS ONLY)....................................................20 TO VIEW AUTO-ARM TIME (LCD KEYPADS ONLY) ...............................................................20 DOOR STRIKE ...........................................................................................................................21 TO VIEW TIME (LCD KEYPADS ONLY) ...................................................................................21 TO SET TIME .............................................................................................................................21 TO DISPLAY ZONE DIRECTORY (LCD KEYPADS ONLY)......................................................21 USER LOG VIEW (LCD KEYPADS ONLY) ...............................................................................21 KEY FOB LOW-BATTERY TEST...............................................................................................22 ON-LINE DOWNLOAD ...............................................................................................................22 USING A PAGER...........................................................................................................................23 CHANGING THE PAGER PHONE NUMBER (FOLLOW-ME)...................................................23 TURN PAGER REPORTING ON/OFF FOR THE PARTITION..................................................24 TURN PAGER REPORTING ON/OFF FOR A USER................................................................24 TESTING THE SYSTEM................................................................................................................25 SYSTEM TEST...........................................................................................................................25 BATTERY TEST .........................................................................................................................25 RECOMMENDATIONS ON SMOKE DETECTORS......................................................................26 EMERGENCY EVACUATION .......................................................................................................27 GLOSSARY ...................................................................................................................................28 RADIO FREQUENCY EMISSIONS STATEMENTS......................................................................32 TELEPHONE/MODEM INTERFACE STATEMENTS ...................................................................32 TELEPHONE OPERATIONAL PROBLEMS.................................................................................33 O560 DECLARATION OF CONFORMITY...............................................................................33 LIMITATIONS OF THIS ALARM SYSTEM ...................................................................................34 -3- Quick Reference TO ARM THE SYSTEM 1. Check to make sure the system is ready. (Green READY light is lit). 2. Enter your 4-digit (or 6-digit) user code. The ARMED light will light. 3. Exit through a door designated by your installer as an exit/entry door. NOTE: If you DO NOT EXIT during the exit time and your system installer has programmed your system for Auto-Stay, the system will arm in the Auto-Stay mode. TO DISARM THE SYSTEM 1. Enter through a door designated by your installer as an exit/entry door 2. Enter your 4-digit (or 6-digit) user code. 3. The system ARMED light will go out. TO ARM THE SYSTEM AND STAY INSIDE 1. Check to make sure the system is ready (Green READY light is lit). 2. Press STAY . 3. Enter your 4-digit (or 6-digit) user code. The ARMED light and the STAY light will both light. REMEMBER: Unless the Quick Exit feature is enabled, you must disarm the system if you want to open a premises entry/exit door after the exit time has passed. TO ARM THE SYSTEM IN INSTANT MODE, AND STAY INSIDE 1. Check to make sure the system is ready (Green READY light is lit). 2. Press 3. Press INSTANT . STAY . 4. Enter your 4-digit (or 6-digit) user code. The ARMED light, the INSTANT light, and the STAY light will all be on. TO RESET SMOKE DETECTOR 1. Enter your 4-digit (or 6-digit) user code twice. -4- Quick Reference (Cont'd) The following table lists the "Quick Commands" available with this control. Key #1 Description Quick Arm ­ if system is ready Keypads All keypads Comments Allows you to arm the system without requiring your user code. User code is always needed to disarm the system. Allows you to arm the system even if some zones are faulted. These zones will be automatically bypassed and will be unprotected. If not enabled, requires user code with authority 1, 2, or 3. May require user code. Lists each zone with its descriptors. Mode terminates after last enabled zone. Provides a listing of all quick commands available in the system. May also require code. May also require code. Also needs user code with authority level 1 or 2. By partition, may also require code. Displays panel's revision. Wireless Key Fob battery test. Activate doorstrike or trigger. May require certain user code. For keypad partition, only LCD* shows phone number. LCD* displays current state first, then offers to toggle. All others just toggle the state. Need user auth. of 1 or 2. Digit 4 (P) enables user to page. Paging must be enabled and turned on. Toggles if users should send page for Open/Close by partition. Connects to downloader while on line, disconnects home phone. LCD* displays current enables, 1,2,P - P=4 #2 Force Arm ­ bypasses faulted zones All keypads Quick Bypass BYPASS nn (zone no.) All keypads All keypads LCD* only LCD* only LCD* only LCD* only LCD* only All keypads LCD* only All keypads All keypads All keypads All keypads All keypads #3 #4 # 50 # 51 # 52 # 53 # 54 # 55 # 56 # 57 # 58 #6 #7 Set Time and Date Zone Directory Quick Help Show Time and Date Show Auto Arm Time User Event Log View Set Auto Arm Time of Current Partition Display Firmware Version Display Key Fob Low Batteries Door Strike Change/View Pager Number Display/Toggle Chime Mode Assign User to Other Partition or to Activate Paging User Page Toggle User On-line Multi-Partition #8 #9 #0 All keypads All keypads All keypads * 2-line alpha display -5- Introduction Congratulations on your decision to protect your home or business with the OMNI-624 or OMNI-624EU security system. You have chosen a reliable, state-ofthe-art security system that is remarkably easy to operate. Your system has been professionally installed by your local Security Company, whose representative can explain the specifics of your system. The keypad is the input and display device for your security system. Your Security Company representative will suggest the model most appropriate for your premises and your needs. There are three types of keypads that can be used with this system: LCD keypad (alpha display), fixed-word keypad (2-digit display), LED keypad. Since your system may use any of these keypads, the displays of all keypads are described in this manual. The OMNI-624 is listed by Underwriters Laboratories for Household Fire and Burglary applications. Throughout this manual, the following conventions are used to represent the keystrokes required to perform the following functions. STAY Press button labeled STAY. BYPASS Press button labeled BYPASS. INSTANT Press button labeled INSTANT. CODE Press button labeled CODE. Enter 4-digit (or 6-digit) user code. Please keep your manual in a convenient location so you can refer to it if needed. -6- System Reference ZONE DESCRIPTIONS In the following table, enter a description of the area of protection for each zone. Example: Zone 1 Windows on north side of building Zone 4 Main entrance to building. Zone 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Description Entry time ________ Door __________ Exit time ________ Entry time ________ Door __________ Exit time is the same for all designated entry/exit doors. -7- System Reference (Cont'd) SEND HELP ALERT All keypads are equipped with emergency-pair keys. In order to activate the alert, both keys must be pressed at the same time. The type of keypad you have installed dictates which keys you press. Your installer will show you how to activate these emergency keys. The emergency keys used for all keypads are shown below. The following SEND HELP ALERT is programmed into my system: KEYS [#] & [D] [7] & [9] [1] & [3] DESCRIPTION PAGER ALERT If programmed, a button on a designated keyfob may also be used to send an alert message to a pager. Ask your installer if t ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.