Detailed instructions for use are in the User's Guide. ®
16
Multimeter with Temperature
Instruction Sheet
P Read First: Safety Information
To ensure that the meter is used safely, follow these instructions: · Do not use the meter if the meter or test leads appear damaged, or if you suspect that the meter is not operating properly. · Disconnect the live test lead before disconnecting the common test lead. · When using the probes, keep your fingers behind the finger guards on the probes. · Do not use the V·Check mode to measure voltages in circuits that could be damaged by this mode's low input impedance (2 k). · Turn off power to the circuit under test before cutting, desoldering, or breaking the circuit. Small amounts of current can be dangerous. · Do not apply more than 600V rms between a meter terminal and earth ground. · Use caution when working with voltages above 60V dc or 30V ac rms. Such voltages pose a shock hazard.
PN 2063513 December 2002 Rev.1, 9/04
2002,2004 Fluke Corporation. All rights reserved. Printed in China
Symbols
Press button. Press button to switch between modes.
Double insulation. Manual ranging mode.
ip14i.eps
Automatic Range Selection
The meter defaults to autoranging when you turn it on. The 4000 mV range can be entered only with manual range selection.
Manual Range Selection
16
MULTIMETER
OFF
CAT
600V
COM
+
To return to autoranging, press for 2 seconds, or change the measurement mode.
ip15i.eps
Battery Saver
If the meter is ON but inactive and not connected to voltage for more than 45 minutes, the display goes blank to preserve battery life. To resume operation, press any button. Battery Saver is disabled in MIN/MAX record mode.
AC and DC Voltage
Also refer to V·Check. Volts AC Input Impedance 5 M 50 Hz to 400 Hz
16
MULTIMETER
Volts DC Input Impedance 10 M
16
MULTIMETER
AC
DC
4000 mV 4V 40V
OFF
400V 600V
OFF
V
AC / DC
CAT
V
AC / DC
CAT
600V
600V
COM
+
COM
+
ip01i.eps
Resistance and Continuity eR
Turn off circuit power before testing. Also refer to V·Check. Resistance
16
MULTIMETER
Continuity
16
MULTIMETER
16
MULTIMETER
Mk
OFF
A
CAT
VÂ¥Check
OFF
600V
TEMPERATURE
COM
+
Low Impedance VÂ¥Check
VÂ¥Check
OFF
A
CAT
VÂ¥Check
A
CAT
600V
TEMPERATURE
600V
TEMPERATURE
COM
+
COM
+
Short
Open
ip02i.eps
<25
Detects shorts and opens 250 µS.
W V·Check
If a dc or ac voltage greater than about 4.5V is present across the inputs when the meter is set to R, G, or e, the meter switches automatically to dc or ac voltage mode (V·Check mode). W Warning Repetitive transients on a dc bus will cause V·Check to select ac volts, even though a hazardous dc voltage may be present. To avoid a misleading display and possible electric shock, manually select the proper volts function for measurements on these circuits. When V·Check is activated, the meter has low input impedance (LoZ) 2 k. This load can alter the voltages in electronic control circuits. Do not use V·Check to measure voltage in circuits that could be damaged by a 2 k load. Hint: V·Check can be effectively used to eliminate "ghost" voltages.
16
MULTIMETER
If AC detected If DC detected Meter puts 2 k load on circuit.
Disable and re-enable V·Check For , and , Disables V·Check and locks meter in selected mode. 2 sec
OFF
A
CAT
V·Check
600V
TEMPERATURE
COM
+
or Re-enables V·Check
or
or
ip09i.eps
Temperature
16
MULTIMETER
F
C
OFF
A
CAT
V·Check
600V
TEMPERATURE
COM
+
80BK Integrated Temperature Probe (Type K)
Vent or Pipe
ip19f.eps
Note correct connector polarity.
To meet stated accuracy, the 80BK temperature adapter must be at the same temperature as the meter.
W Warning
To avoid possible electric shock, DO NOT apply thermocouple tip to any conductor that is greater than 30V AC, 42.4V pk, or 60V DC to earth.
Capacitance E
Turn off circuit power; then disconnect and discharge the capacitor before measuring capacitance.
16
MULTIMETER
If the capacitor requires more discharging, diSC is displayed while the capacitor discharges.
OFF
A
CAT
V·Check
600V
TEMPERATURE
COM
+
1 µF
10 µF
100 µF
10,000 µF
+
ip05i.eps
Note correct probe polarity for polarized capacitors.
Microamps µA
Range 0 to 200 µA
16
MULTIMETER
µA AC
µA DC
OFF
A
CAT
V·Check
600V
TEMPERATURE
COM
+
Flame sensor probe
Control module
ip20i.eps
Example: Flame rectification circuit. To measure flame rectification circuits: 1. 2. 3. 4. Turn function switch to far right position. Push select button 3 times to select µA. Connect meter between flame sensor probe and control module. Turn heating unit on and record µA measurement.
Diode Test G
Turn off circuit power before testing. For best results diodes should be measured out of circuit. Also refer to V·Check.
Good Diode
16
MULTIMETER
Typical voltage for silicon diode
16
MULTIMETER
Low Impedance V·Check
OFF
A
CAT
V·Check
OFF
A
CAT
V·Check
600V
TEMPERATURE
600V
TEMPERATURE
COM
+
COM
+
Single beep
ip03i.eps
Forward Bias Bad Diode
16
MULTIMETER
Reverse Bias
16
MULTIMETER
OFF
A
CAT
V·Check
OFF
A
CAT
V·Check
600V
TEMPERATURE
600V
TEMPERATURE
COM
+
COM
+
or
ip04i.eps
Shorted
Open
MIN MAX
µF
(Records the lowest and highest measurements)
V·Check, autoranging, and Battery Saver are disabled. Put the meter
in the proper range before entering MIN MAX. When the reading changes more than about 50 digits, the meter gives a short beep. When a new minimum or maximum is recorded, the meter gives a long beep.
Enter Present Reading with MIN MAX Input Change Alert TM
Maximum Reading
2 sec
To Exit Minimum Reading
ip10i.eps
MIN MAX with Elapsed Time
µF
Records the hours and minutes between when MIN MAX was entered and the last high and low was recorded. OL is displayed for times longer than 99:59. To enable the MIN MAX timer, hold down M while turning the rotary switch from OFF to either measurement mode.
Enter MIN MAX. View Present Reading
Maximum Reading
Maximum Reading Elapsed Time
2 sec
Minimum Reading Elapsed Time
Minimum Reading
Exit MIN MAX
ip11i.eps
To disable the beeper for all modes, hold down r for 2 seconds while turning the meter on.
Disabling the Beeper
Continuity Capture
To set up the meter to capture intermittent shorts and opens, turn the switch to GR, connect the leads to the circuit; then press M.
ip12i.eps
Captures transitions longer than 250 µs (1/4000th of a second). Transitions after the first transition cause the meter to beep, but the display does not change. To reset the display to the current condition, press M. To exit, press M for 2 seconds, or change the measurement mode.
Maintenance
Clean the case with a damp cloth and detergent. Do not use abrasives or solvents. Battery Replacement Remove the test leads before disassembling the case.
Replacement Parts Fluke TL-75 (Double-insulated leads) PN 855705 80BK (Integrated Temperature Probe) PN 1273124 Service and Parts This meter should be serviced only by a qualified service technician. To locate an authorized service center, call: USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 Or, visit Fluke's Web site at www.fluke.com.
C O M
60 0V
+
+
ip13i.eps
Specifications
Accuracy is specified for a period of one year after calibration, at 18°C to 28°C (64°F to 82°F) with relative humidity to 90%. AC conversions are ac-coupled, average responding, and calibrated to the rms value of a sine wave input. Accuracy specifications are given as follows: ±([% of reading] + [number of least significant digits])
Function Temperature Range -10°C to 400°C 14°F to 752°F Resolution 0.1°C or 0.2°F 0.1°C or 0.2°F Accuracy ±(1.0% + 0.8°C) typical ±(1.0% + 1.5°F) typical ±(5.0% + 1.5°C) typical ±(5.0% + 3.3°F) typical Accuracy
(Type K Thermocouple) -40°C to -10°C -40°F to 14°F
Error does not include Type K Thermocouple errors. Function Range 4000 mV 4.000V 40.00V 400.0V 600V 1 4000 mV 4.000V 40.00V 400.0V 600V 400.0 4.000 k 40.00 k 400.0 k 4.000 M 40.00 M 1.000 µF 10.00 µF 100.0 µF 10000 µF
1
Resolution 1 mV 0.001V 00.01V 000.1V 1V 1 mV 0.001V 00.01V 000.1V 1V 0.1 0.001 k 0.01 k 0.1 k 0.001 M 0.01 M 0.001 µF 0.01 µF 0.1 µF 1 µF
±(1.9% + 3) ±(1.9% + 3) f ±(1.9% + 3) (50 to 400 Hz) ±(1.9% + 3) ±(1.9% + 3) ±(0.9% + 2) ±(0.9% + 2) ±(0.9% + 1) E ±(0.9% + 1) ±(0.9% + 1) ±(0.9% + 2) ±(0.9% + 1) ±(0.9% + 1) ±(0.9% + 1) ±(0.9% + 1) ±(1.5% + 3) ±(1.9% + 2) ±(1.9% + 2) ±(1.9% + 2) | 1000 µF ±(1.9% + 2) >1000 µF ±(10% + 90) typical ML 2.000V 0.001V ±(1.9% + 2)2 1. The 4000 mV range can be entered only in manual range mode. Use the 4000 mV range with accessories. 2. The beeper is guaranteed to come on at <25 and turn off at >250. The meter detects opens or shorts 250 µs.
Function
Range 0 to 200 µA 0 to 200 µA
Resolution 0.1 µA 0.1 µA
Accuracy ±(2% + 3 counts) ±(1% + 2 counts)
Burden Voltage <5 mV/µA <5 mV/µA
N
(50 Hz to 400 Hz)
M
Function f E
Overload 1 Protection 600V rms 600V rms
Input Impedance (Nominal) >5 M <100 pF V·Check and LoZ = >2 k <200 pF (ac coupled)2 >10M <100 pF V·Check and LoZ = >2 k <200 pF2 Common Mode Rejection Ratio (1 k Unbalanced) Normal Mode Rejection
f E
600V rms 600V rms
>60 dB at dc 50 or 60 Hz >100 dB at dc, 50 or 60 Hz Open Circuit Test Voltage >50 dB at 50 Hz or 60 Hz Full Scale Voltage To 4.0 M 40 M <450 mV dc <1.5V dc 2.400V dc
J L
600V rms 600V rms
<1.5V dc 2.4-3.0V dc
Short Circuit Current J L 600V rms 600V rms <500 µA 0.95 mA (typical)
1. 3 x 106 V Hz maximum 2. 2 k input impedance up to 50V. Impedance increases with input voltage to >300 k at 600V.
MIN MAX Recording Accuracy and Response Time
Specified accuracy of the measurement function ±12 digits in dc for changes >200 ms in duration (±40 digits in ac). Typical 100 ms response to 80%. Example 1: This would mean ±1.2° when recording temperature. Example 2: This would mean ±1.2 µA when recording µA or ±12A if used with a dc amp probe (with a mV input).
MIN MAX Recording with Elapsed Time
Elapsed Time 0 to 100 hours (99:59) Resolution 1 minute Accuracy 0.3% typical
Maximum Voltage Between any Terminal and Earth Ground: Display: Operating Temperature: Storage Temperature: Temperature Coefficient: Relative Humidity: Battery Type: Battery Life: Shock: Vibration: Size (H x W x L): Weight: Safety:
600V rms 3 3/4-digits, 4000 counts, updates 4/sec -10°C to 50°C (14°F to 122°F) -30°C to 60°C (-22°F to 140°F) indefinitely (to -40°C (-40°F) for 100 hrs) (.1 x specified accuracy)/°C (<18°C or >28°C) 0% to 90% (-10°C to 35°C; 14°F to 95°F) 0% to 70% (35°C to 50°C; 95°F to 122°F) 9V, NEDA 1604 or IEC 6F22 650 continuous hours with alkaline 450 continuous hours with carbon-zinc 1 meter drop 6 sides. Class II vibration MIL-PRF-28800F 3.46 cm x 7.05 cm x 14.23 cm (1.35 in x 2.75 in x 5.55 in) 286g (10 oz) Designed to Protection Class II requirement of UL3111, ANSI/ISA-S82, CSA C22.2 No 231, and VDE 0411, and IEC 1010 overvoltage Category III (CAT III, 600 Volts). Complies with FCC Part 15, Class B, and VDE 0871B. Trademark of TÜV Product Services. Complies with EN 61010-1: 1993.
EMI Regulations:
Certifications:
P$
TUV, UL and VDE
LIMITED WARRANTY & LIMITATION OF LIABILITY Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is three years and begins on the date of shipment. Parts, product repairs and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries or to any product which, in Fluke's opinion, has been misused, altered, neglected or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption. Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another country. Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to a Fluke authorized service center within the warranty period. To obtain warranty service, contact your nearest Fluke authorized service center ...
|