9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your FRIGIDAIRE FD27LKEC : user manual, user guide, instruction manual.
Search a brand
Advanced Search

Need help using a product?
Look at the reviews on FRIGIDAIRE FD27LKEC

User manual FRIGIDAIRE FD27LKEC

Diplodocs help download the user guide FRIGIDAIRE FD27LKEC .

Download the complete user guide (1602 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide FRIGIDAIRE FD27LKEC

Detailed instructions for use are in the User's Guide.

Use & Care Manual Assembly Instructions Included 27" Stainless Steel Outdoor Grill with Electronic Ignition Welcome/Product Registration ............ 2 General Safety Instructions .................. 3 Fligid alie Grill Features and Components ...... 4-12 Grill Assembly ................................ 13-14 Gas Requirements Pre-Operation Leak Testing ........... 15-19 Lighting the Grill ............................. 20-21 Using the Grill Using the Rotisserie & Side Burners ................ 22-24 Fligid alie Care & Maintenance ............................ 25 Troubleshooting Your Grill ............. 26-27 Warranty ............................................... 28 Visit the Frigidaire Web Site at: http://www.frigidaire.com READ AND SAVE THESE INSTRUCTIONS Welcome & Congratulations Congratulations on your purchase of a new grill! We at Electrolux Home Products are very proud of our product and we are completely committed to providing you with the best service possible. Your satisfaction is our #1 priority. Please read this Use & Care Manual very carefully. It contains valuable information on how to properly maintain your new grill. We know you'll enjoy your new grill and thank you for choosing our product. We hope you consider us for future purchases. PLEASE READ AND SAVE THESE INSTRUCTIONS This Use & Care Manual provides specific operating instructions for your model. Use your grill only as instructed in this manual. These instructions are not meant to cover every possible condition and situation that may occur. Common sense and caution must be practiced when installing, operating and maintaining any appliance. Please record your model and serial numbers below for future reference. This information is found on the serial plate located on the back of the built-in grill or on the inside of the cart door (complete grill & cart model). NOTE: Use only soap and water to clean the serial plate. Model Number: Serial Number: Purchase Date: Gas Type: Please attach sales receipt here for future reference. Questions? 1-800-Frigidaire Register Your Product The PRODUCT REGISTRATION CARD should be filled in completely, signed and returned to Electrolux Home Products North America. Please complete and mail in the Product Registration Card included with your grill. Please retain this manual for future reference © 2004 Electrolux Home Products, Inc All rights reserved 2 General Safety Instructions IMPORTANT SAFETY INFORMATION - Read this manual carefully before using your grill to reduce the risk of fire, burn hazard or other injury. - Extreme care should be used because of the high temperatures produced by this appliance. CHILDREN SHOULD NOT BE LEFT UNATTENDED IN AN AREA WHERE THE GRILL IS BEING OPERATED. - This appliance must be kept clear from combustible materials, gasoline or other flammable vapors and liquids. Do not allow flammable materials to come in contact with grate, burner or hot surfaces. - Use only outdoors and provide good ventilation to avoid carbon monoxide build-up which could result in injury or death. - Do not repair or replace any part of this appliance unless it is specifically recommended in this manual. A qualified service technician should conduct all other service. - Follow the installation and servicing instructions provided with this product. Have your grill installed by a qualified service technician. - Locate the main gas supply valve so that you know how to shut the gas off to your grill. - If you smell gas, make sure all gas connections are tight before operation. If you continue to smell gas, call a qualified technician. - When lighting a burner, always pay close attention to what you are doing and be certain you are pushing the igniter that lights the burner you intend on using. - Always keep your face and body as far away from the grill as possible when lighting to reduce the risk of burn. - Extinguish all flames and do not smoke while engaging gas and igniting the grill. FOR YOUR SAFETY If you smell gas: 1. Shut off gas to the appliance. 2. Extinguish any open flames. 3. Open grill hood. 4. If odor continues, immediately call your gas supplier. CALIFORNIA PROPOSITION 65 - WARNING: The burning of gas cooking fuels generates some byproducts which are on the list of substances which are known by the State of California to cause cancer or reproductive harm. California law requires businesses to warn customers of potential exposure to such substances. To minimize exposure to these substances, always operate this unit according to the Use and Care Manual. Provide good ventilation when cooking with gas. This appliance is not intended to be installed in or on recreational vehicles or boats. TESTED IN ACCORDANCE WITH ANSI Z21.58b/CGA1.6b-M02 STANDARD FOR OUTDOOR COOKING GAS APPLIANCES. THIS GRILL IS FOR OUTDOOR USE ONLY. Check your local building codes for the proper method of installation. In the absence of local codes, this unit should be installed in accordance with the National Fuel Gas Code No. Z223.1 and the National Electrical Code ANSI/NFPA No.70. FOR YOUR SAFETY DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance. WARNING DO NOT try lighting this appliance without reading the "LIGHTING THE GRILL" section of this manual. FOR OUTDOOR USE ONLY 3 Grill Features: FD27 FD27LKEC 1 2 3 7 8 9 4 5 6 10 11 12 13 1. Control knob: Main burner 2. Control knob: Rear infrared burner 3. Control knob: Main burner 4. Electronic igniter: Main and rear infrared burner 5. Control panel 6. Control knob: Main burner 7. Hood handle 8. Warming shelf 9. Rear infrared burner 10. Tool bar 11. Electronic igniter: side burner 12. Control knob: side burner 13. Front door 4 Grill Assembly SIDE SHELF ATTACHMENT 1. 2. 3. 4. 5. Remove the side burner together with the gas hose from the front door. Make sure the hose is in good condition before installing the side burner (See Fig. 1) The screws used to attach the side shelf and side burner are already screwed into the two side panels. Remove the screws from the side panels. (See Fig. 2) Align with the holes in the left side shelf, and then re-attach into the holes on the left side panel of the grill. Repeat the above steps to install the right side burner on right side panel. Store extra hose inside the burner body after removing the hose cover. F ig . 1 Fig. 2 13 Grill Assembly SIDE BURNER HANDLE ASSEMBLY 1. 2. To assemble the side burner lid handle, open the lid then cut off the plastic tie in the screw hole. Install the handle in the lid as shown. (See Fig. 3) Remove the two screws from the handle. Align with the holes in the side burner, then re-attach into the holes on the stand of the handle, and tighten up the screws. (See Fig. 4) Fig. 3 Fig. 4 14 Gas Requirements GENERAL INFORMATION Never attach an unregulated gas line to the appliance. Connection to an unregulated gas line can cause excessive heat or fire. Verify the type of gas supply to be used ­ either Natural Gas (N.G.) or Liquid Propane (L.P.) ­ and make sure the serial plate agrees with that of the supply. Conversion kits are available separately for an additional cost which will enable you to convert your grill from L.P. to N.G. or to convert your grill from N.G. to L.P. Please see your Frigidaire dealer for more information. NOTE: Always have a qualified service technician perform difficult conversions or modifications. For natural gas installations, an installer must supply a gas shutoff valve that is easily accessible to the grill. All installer supplied parts must conform to local codes, or in the absence of local codes, with the National Electrical Code, ANSI/ NFPA 70, National Fuel Gas Code, ANSI Z223.1. All pipe sealants must be an approved type and resistant to the actions of L.P. gases. Never use pipe sealant on flare fittings. All gas connections should be made by a competent qualified service technician and in accordance with local codes and ordinances. In the absence of local codes, the installation must comply with the National Fuel Gas Code, ANSI Z223.1. Gas conversion kits may be purchased separately. When ordering gas conversion kits, have the model number and the type of gas (N.G. or L.P.) used for your grill. You can call 1-800-Frigidaire to buy the conversion kits. This grill and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 1/2 PSIG (3.5 kPa.). This grill must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG (3.5 kPa.). The installation of this grill must conform with local codes, or in the absence of local codes, with National Fuel Code, ANSI Z223.1a. NATURAL GAS INSTALLATION The gas inlet supply pressure should be between 5" and 14" water column (w.c.). A step down regulator is required if the line pressure is in excess of 14" w.c. Inlet pressure must not exceed 14" water column (1/2 PSIG). Check with your local gas utility company or with local codes for instructions on installing gas supply lines. Be sure to check on type and size of run, and how deep to bury the line. If the gas supply line is too small, the grill will not operate correctly. Any joint sealant used must be an approved type and be resistant to chemical breakdown resulting from the reaction with N.G. NOTE: The gas line connection and the gas fitting must be the same diameter. Installer supplied shutoff valve (not included). Place the shutoff valve in an accessible location to enable the gas supply to be cut off to the unit. NOTE: A flexible natural gas line is not included with Frigidaire Gallery grills. Natural gas flex line must be purchased separately based on the distance of your grill location from the natural gas line. Please be sure to check the size of your home's natural gas line fitting to make sure you get the right size connection for your particular application. If you have questions, please consult your local natural gas distributor or qualified service technician. 15 Gas Requirements INSTALLATION OF NATURAL GAS REGULATOR 1. 2. 3. The Natural Gas regulator has been attached to the manifold. Attach the gas hose to the regulator as shown. (See Fig. 5) Put the gas hose through the hole on the back of the cart panel. (See Fig. 6) Link a quick-connect fitting to the hose by hand. Quick-connect fitting not included. (See Fig. 7) Fig. 5 Fig. 6 Fig. 7 16 Gas Requirements L.P. GAS INSTALLATION Frigidaire Gas Grills that are set to operate with L.P. gas come with a high capacity hose and regulator assembly. (Note: Only use the pressure regulator and hose assembly supplied with the grill or a replacement pressure regulator and hose assemblies specified by Frigidaire). This assembly is designed to connect directly to a standard 20 lb. L.P. cylinder. L.P. cylinders are not included with the grill. L.P. cylinders can be purchased separately at an independent dealer. Shutoff Valve Collar LP hose/ regulator supplied with grill. (Type 1 connector) Ensure that the black plastic grommets on the L.P. cylinder valve are in place and that the hose does not come into contact with the grease tray or the grill head. L.P. TANK INFORMATION Never use a dented or rusted L.P. tank or cylinder with a damaged valve. The cylinder used must include a collar to protect the cylinder valve. L.P. cylinders are equipped with an O.P.D. (Overfilling Prevention Device). The device shuts off the flow of gas to a cylinder after 80% capacity is reached. This limits the potential for release of gas when the cylinder is heated, averting a fire or possible injury. The L.P. cylinder must have a shut-off valve terminating in an L.P. gas supply cylinder outlet specified, as applicable, for connection No. 510 in the standard for compressed gas cylinder valve outlet and inlet connection ANSI/CGAV1. Cylinders must not be stored in a building, garage, or any other enclosed area. (The L.P. cylinder must have an overfill protection device, OPD, on it.) The L.P. gas supply cylinder must be constructed and marked in accordance with the specifications for L.P. gas cylinders of the U.S. Department of Transportation (DOT). "Cylinders, Spheres and Tubes for the Transportation of Dangerous Goods." L.P. TANK USE · When turning the L.P. tank on, make sure to open the valve SLOWLY two (2) complete turns to ensure proper gas flow. Most gas tanks now come equipped with a leak detector mechanism internal to the tank. When gas is allowed to escape rapidly it shuts off the gas supply. Opening the valve rapidly may stimulate a gas leak, causing the safety device to activate, restricting gas flow causing low flames. Opening the valve slowly will ensure this ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.