9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your FURMAN PL-PRO-E : user manual, user guide, instruction manual.
Search a brand
Advanced Search

Need help using a product?
Look at the reviews on FURMAN PL-PRO-E

User manual FURMAN PL-PRO-E

Diplodocs help download the user guide FURMAN PL-PRO-E .

Download the complete user guide (2756 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide FURMAN PL-PRO-E

Detailed instructions for use are in the User's Guide.

12 PL-PRO POWER CONDITIONER AND LIGHT MODULE PL-PRO POWER CONDITIONER AND LIGHT MODULE 1 PL-PRO, PL-PRO-E SPECIFICATIONS Note: Where different, PL-PRO-E specs are in parentheses. Current rating: 20 Amps, 2400 watts at 120 VAC (16 Amps, 3600 watts at 230 VAC) Input Voltage Range: 0 to 280 VAC without damage Meter Accuracy: Voltmeter: ± 2 (±4) VAC; Ammeter: ± 2 amps, calibrated with trimpot adjustments Spike Protection Modes: Line to neutral, neutral to ground, line to ground Clamping Voltage, all modes: TVSS rating 400V peak, L-N, L-G, N-G, tested to UL 1449 (TVSS rating 400V peak, L-N; 680V peak, L-G, N-G) Response time: 1 nanosecond Maximum surge current: 11,000 amps (8 x 20mS pulse) Maximum spike energy: 550 joules total Noise attenuation: Differential mode: Greater than 40 dB; Common mode: greater than 60 dB; both 1 to 200 MHz Dimensions: 1.75" (4.45 cm) H x 19" (48.25 cm) W x 8" (25 cm) D. Weight: 6 lbs (2.7 kg). Construction: Steel chassis, zinc chromate plating; brushed and black anodized aluminum front panel; glass epoxy printed circuit boards. Power consumption: 32 watts Safety Information: PL-PRO: UL listed. CUL listed. PL-PRO-E: CE Options: "-G" Suffix (PL-PRO only): provides "super spec", isolated ground 120V outlets for special applications. Please consult factory before ordering to determine suitability in your application. PRO SERIES Power Conditioner and Light Module MODEL PL-PRO MODEL PL-PRO-E The Furman PL-PRO is made in the U.S.A. Furman Sound, Inc. 1997 South McDowell Blvd. Petaluma, California 94954-6919 Phone: (707) 763-1010 Fax: (707) 763-1310 Web: www.furmansound.com E-mail: info@furmansound.com 3-9918 Owner's Manual © 1997 FURMAN SOUND, INC. 960110-1405 2 PL-PRO POWER CONDITIONER AND LIGHT MODULE PL-PRO POWER CONDITIONER AND LIGHT MODULE 11 Other Furman Products Power Conditioning & Distribution PL-8, PL-PLUS PL-TUNER PLH-15 PM-8 PM-PRO PS-8, PS-8R PS-PRO PowerLink PowerPort MiniPort-15 MiniPort-20 MiniPort-30 MiniPort-15Q MiniPort-20Q RS-1 RS-2 AR-1215 AR-2306 AR-1220 AR-1230 AR-2330 AR-2330D AR-PRO BP-1000 ACD-100 ASD-120 IT-1210 IT-1220 IT-1230 PlugLockTM PGP-20 PGP-60 PGP-S Power Conditioner & Light Module, 15A Power Conditioner/Instrument Tuner, 15A Power and Light Center, 15A Power Conditioner/Monitor, 15A Power Conditioner/Monitor, 20A Power Conditioner/Sequencer, 15A Power Conditioner/Sequencer, 20A Remote AC Power Sequence Controller Remote AC Power Controller Power Relay, 15A Power Relay, 20A Power Relay, 30A Power Relay for Quad Box Mount, 15A Power Relay for Quad Box Mount, 20A System Control Panel, Maintained Switching System Control Panel, Momentary Switching AC Line Voltage Regulator, 15A, 120V AC Line Voltage Regulator, 6A, 230V AC Line Voltage Regulator, 20A, 120/100V AC Line Voltage Regulator, 30A, 120/100V AC Line Voltage Regulator, 30A, 220/230/240V AC Line Voltage Regulator, 30A, 240/230/220V, N. America Use AC Line Voltage Regulator, 30A, 120V, Worldwide Use On-Line Uninterruptible Power Supply, 1 KVA Power Distro, 100A Sequenced Power Distro, 120A Isolation Transformer, Balanced AC Power, 10A Isolation Transformer, Balanced AC Power, 20A Isolation Transformer, Balanced AC Power, 30A Locking Outlet Strip PlugLock-PRO Locking Outlet System, 20A PlugLock-PRO Locking Outlet System, 60A Remote Power Switcher, 60A Audio Signal Processing PQ-3 Reissue PQ-4 Q-151, Q-152 Q-301, Q-302 Q-602 PUNCH-10 X-312 X-324 X-424 X-524 C-132 LC-6 SP-20A HA-6A HR-2 HDS-6 HR-6 PB-48 PB-48D MM-3 MM-4A MM-8A SM-3 IP-8 IP-2, IP-2B SRM-80 VU-40 SC-1, 2 Parametric Equalizer, Instrument Preamp Parametric Equalizer, 4 band Dual 15-Band Graphic Equalizer 30-Band Graphic Equalizer Dual 30-Band Graphic Equalizer Bass Enhancement System 12 dB Crossover 2-Way/3-Way 24 dB Crossover 3-Way/4,5-Way 24 dB Crossover 4-Way 24 dB Crossover Compressor/Limiter Stereo Compressor/Gate Stereo Half Rack Power Amp, 20W per channel Headphone/Monitor Amp Headphone Passive Remote Box Headphone Distribution System Personal Headphone Mixer for use with HDS-6 48-Point Patch Bay with TRS Connectors 48-Point Patch Bay with TRS and D-Sub Connectors (Full range of patch cords also available) Three Input Mic Mixer 4 x 1 Rack-Mount Mixer 4 x 2 Rack-Mount Mixer Stereo Mixer with Ducking Iso-Patch, Isolated Patch Bay, 8 channel Iso-Patch, Dual Isolator, 2 channel Signal Router/Monitor System Monitor (Power/VU Meter) Security Covers Please contact us by phone, fax or e-mail for a free copy of our latest color catalog. 10 PL-PRO POWER CONDITIONER AND LIGHT MODULE PL-PRO POWER CONDITIONER AND LIGHT MODULE 3 Three Year Limited Warranty Important Note: To be sure of obtaining full protection under the terms of the Limited Warranty in case your ownership documents are lost, please fill out and return the Warranty Registration Card immediately. Please verify that the serial number shown on the Warranty Card matches the serial number on your unit. The Furman PL-PRO is warranted against failures due to defective parts or faulty workmanship for a period of three years after delivery to the original owner. During this period, Furman will make any necessary repairs without charge for parts or labor. Shipping charges to the factory or repair station must be prepaid by the owner; return shipping charges (via UPS Ground) will be paid by Furman. This warranty applies only to the original owner and is not transferable. Also, it does not apply to repairs done other than by the Furman factory or Authorized Repair Stations. This warranty shall be cancellable by Furman at its sole discretion if the PL-PRO unit has been subjected to physical abuse, has been operated without a proper safety ground, or has been modified in any way without written authorization from Furman. Furman's liability under this warranty is limited to repair or replacement of the defective unit. Furman will not be responsible for incidental or consequential damages resulting from the use or misuse of its products. Some states do not allow the exclusion of incidental or consequential damages, so the above limitations may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Warranty claims should be accompanied by a copy of the original purchase invoice showing the purchase date (if a Warranty Registration Card was mailed in at the time of purchase, this is not necessary). Before returning any equipment for repair, please read the important information on service below. Safety Information To obtain best results from your Furman PL-PRO, please be sure to read this manual carefully before using it. WARNING: To reduce the risk of electrical shock, do not expose this equipment to rain or moisture. Dangerous high voltages are present inside the enclosure. Do not remove the covers. Other than the light bulbs, there are no user serviceable parts inside. Refer servicing to qualified personnel only. The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated dangerous voltage within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock. Important Safety Instructions Please read prior to installation 1. Please read and observe all of the safety and operating instructions before the PL-PRO is operated. Retain these instructions for future reference. 2. The PL-PRO should not be used near water -- for example, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, near a swimming pool, etc. 3. The PL-PRO should be situated so that its location and position do not interfere with its proper ventilation. For example, the PL-PRO must not be placed on a rug, bed, sofa, or similar surface which impedes airflow across the chassis. 4. Do not place the PL-PRO near heat sources such as radiators, heat registers, stoves, or other appliances that produce heat. 5. The PL-PRO should only be connected to a 120 VAC, 60 Hz, 20 amp grounded electrical outlet. Outlets wired for 20 amps may be identified by the T-shaped socket opening that accepts the perpendicular blades of the PL-PRO's power plug. If you don't have a 20 amp outlet available, have one installed by a qualified electrician. Do not defeat the ground or polarization of the power plug. Service Before returning any equipment for repair, please be sure that it is adequately packed and cushioned against damage in shipment, and that it is insured. We suggest that you save the original packaging and use it to ship the product for servicing. Also, please enclose a note giving your name, address, phone number and a description of the problem. NOTE: All equipment being returned for repair must have a Return Authorization (RA) Number. To get an RA Number, please call the Furman Service Department: (707) 763-1010, ext. 40. Please display your RA Number prominently on the front of all packages. 15 amp 20 amp 6. Route the power cord and other cables so that they are not likely to be walked on, tripped over, or stressed. Pay particular attention to condition of cords and 4 PL-PRO POWER CONDITIONER AND LIGHT MODULE PL-PRO POWER CONDITIONER AND LIGHT MODULE 9 cables at plugs, and the point where they exit from the PL-PRO. To prevent risk of fire or injury, damaged cords and cables should be replaced immediately. 7. Clean the PL-PRO with a damp cloth only. Do not use solvents or abrasive cleaners. Never pour any liquid on or into the PL-PRO. 8. When left unused for a long period of time, the power cord of the PL-PRO should be unplugged from the outlet. 9. The PL-PRO should be serviced by qualified service personnel when: a. The power supply cord or the plug has been frayed, kinked, or cut. b. Objects have fallen or liquid has spilled into the unit. c. The PL-PRO has been exposed to rain or other moisture. d. The PL-PRO does not appear to operate normally or exhibits a marked change in performance. e. The PL-PRO has been dropped, or the enclosure damaged. 10. The PL-PRO requires that a safety ground be present for proper operation. Any attempt to operate the PL-PRO without a safety ground is considered improper operation and could invalidate the warranty. 11. Light bulbs are the only user-serviceable parts in the PL-PRO. Instructions for replacing them are on pages 6-7. The light tubes and end caps become quite warm to the touch in normal operation. To avoid burning your fingers, allow the cap to cool completely before unscrewing it. If you find that the heat from the tubes is excessive, try reducing the setting of the dimmer knob. 12. Do not attempt to service the PL-PRO beyond what is described in this manual. All other servicing should be referred to qualified service personnel. Power Status LEDs The PL-PRO's status LEDs inform you of abnormal conditions at a glance: Symptom: Possible Cause: Action Needed: Symptom: Possible Cause: Action Needed: Symptom: Possible Cause: Action Needed: PROTECTION OK Indicator not lit. Protection devices are damaged. Factory service. GROUND OK Indicator not lit. No building ground, bad outlet. Locate good ground, run ground wire. All voltmeter LEDs are flashing. PL-PRO is receiving 130-140 volts. (If only the LED under the 90V mark is flashing, PL-PRO is receiving 80-90V). Correct the line voltage. Consider installing a Furman voltage regulator. EXTREME VOLTAGE Indicator flashing. Input voltage is below 80 or above 140 volts, causing power to the PL-PRO's outlets to be shut down. Correct the line voltage. Consider installing a Furman voltage regulator. PROTECTION EXTREME OK VOLTAGE GROUND OK FLASHES WHEN SHUT DOWN Symptom: Possible Cause: Action Needed: Voltmeter Displays The PL-PRO informs you of voltage problems at a glance. The following chart summarizes how the PL-PRO's voltmeter responds to input voltages from extremely low to extremely high. 90 100 110 120 128 AC VOLTS HING DISPLAY INDICATES OUT-OF-RANGE -- PROTECTIVE SHUTDOWN MAY OC Mains Vltg. Voltage Status Below 80V 80-90 90-104 106-108 110-120 122-124 126-128 130-140 Above 140 Extreme (Shutdown) Low Marginal Low Medium Low Normal Medium High High High Marginal Extreme (Shutdown) PL-PRO Voltmeter Reading Meter off--Extreme Voltage LED flashes The LED beneath the 90V mark flashes Meter Reads in Low Red Meter Reads in Low Yellow Meter Reads in Green Meter Reads in High Yellow Meter Reads in High Red All Meter LEDs Flash Meter off--Extreme Voltage LED Flashes Outlets OFF ON ON ON ON ON ON ON OFF 8 PL-PRO POWER CONDITIONER AND LIGHT MODULE PL-PRO POWER CONDITIONER AND LIGHT MODULE 5 NOTE: The Voltmeter and status LEDs stay on even when the power switch is off. This feature allows you to check voltage before powering up your equipment. These LEDs are designed for continuous, ongoing use. They consume little power, just a few cents worth a month, like a clock. UNSWITCHED OUTLET: This outlet provides conditioned power at all times when the PL-PRO is plugged i ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.