9 562 brands
2 694 000 user's guides |
|
Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your FURMAN SB1000 : user manual, user guide, instruction manual.
|
|
Need help using a product?
|
|
User manual FURMAN SB1000
Preview of the first 3 pages of manual
You either have JavaScript turned off or an old version of Adobe Flash Player Get the latest Flash Player.
Manual abstract: user guide FURMAN SB1000
Detailed instructions for use are in the User's Guide. SB-1000 MANUAL
SB-1000 MANUAL FEATURES
600 Watt / 1000VA capacity 3 minute back-up at full 5 amp load. 32 minute back-up with typical computer / monitor Adjustable output voltage for 110/115/120 VAC for U.S. units and 220/230/240 VAC for export units. RS-232 Interface performs monitoring functions and provides orderly computer shutdown Phone/fax line protection 19 inch rack mount ears included UL - CUL listed Furthermore, in order to save the battery energy, the UPS will automatically turn off under backup mode if none of the connected equipment is activated. Advanced Battery Management The UPS conveys its battery's status with the use of visual and audible indicators located internally and on its front panel. Its self-test function (which occurs when the unit is activated) detects a weak battery before it is put into service.
· · · · · · ·
S A F E T Y I N F O R M AT I O N
SAVE THESE INSTRUCTIONS Â This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries.
INTRODUCTION
Please read and save this manual!
Thank you for selecting the Furman SB-1000 or Servicing of the UPS and/or SB-1000E uninterruptible power supply (UPS). replacement of the batteries should This manual is a guide to install and use the be performed by authorized Furman UPS. It includes important safety instructions service professionals only. for operation and correct installation of the UPS. If you should have any problems with the UPS, please refer to this manual before calling FEATURES customer service. Front Panel Please save the packaging materials! The 1 "UPS1" Power Switch UPS`s shipping materials are designed to Turns power ON/OFF to the UPS1 outlets on provide protection during delivery. These the rear panel. materials are invaluable if you ever have to return the UPS for service. Damage during 2 "UPS2" Power Switch transit is not covered under the warranty. Turns power ON/OFF to the UPS2 outlets on Intelligent Microprocessor Control rear panel. The UPS is a microprocessor-controlled unit. The SB-1000 provides reliable power during AC swells, sags and interference.
1
3 "Bypass" Power Switch Turns power ON/OFF to the BYPASS outlet on rear panel.
SB-1000 MANUAL
SB-1000 / SB-1000 E Front Panel
Test Battery Fault AC Normal Battery in use UPS1 UPS2 Bypass Silence Buzzer Off On Switch
4 "Battery Fault" Indicator The indicator will light when the battery is weak. Recharge the battery for at least four hours. If the light remains after recharging, replacement of the batteries may be necessary TEL/MODEM Remote by a Furman service professional. INPUT IN OUT Port
BREAKER 5 "AC Normal / Battery in use" Indicator When indicator is ON, the power condition is normal. When indicator is flashing, the unit is in Battery backup mode.
1
2
3
4
5
6
7
8
software to support WINDOWS, DOS, NOVELL operating systems. 2 Phone/Fax Protection Ports 3 Circuit Breaker Protection Serves as a current overload and fault protection. BYPASS UPS1 UPS2 4 IEC AC input The AC power cord plugs in here. 5 Bypass Outlet This provides a convenient surge protected outlet for items not requiring sag/swell protection or backup during power failure. 6 UPS2 Outlets These outlets have battery backup protection and can be controlled by the UPS2 power Test Switch switch on the front panel. Battery Fault AC Normal
BYPASS UPS2 UPS1
6 "Test Button" Use this button to put the unit into battery backup mode to check for proper operation. It also turns off the alarm when in backup mode. 7 Main Power Switch TEL/MODEM Remote INPUT IN OUT This can be used as the master on/off switch Port for your equipment connected to the UPS.
BREAKER
8 optional rack ears (supplied) Rear Panel
UPS1
UPS2
Bypass
1 Communication Function Provides RS-232 interface and UPSMON
7 UPS1 Outlets Buzzer Off On Silence These outlets have battery backup protection and can be controlled by the UPS1 power switch on the front panel.
Battery in use
SB-1000 Rear Panel
Remote Port TEL/MODEM IN OUT BREAKER INPUT
BYPASS
UPS2
UPS1
1
2
3
4
5
6
7
2
SB-1000 MANUAL
SB-1000 E Rear Panel
Remote Port TEL/MODEM IN OUT BREAKER INPUT
BYPASS
UPS2
UPS1
1 2 INS TA L L AT I O N
3
4
5
6
7
Inspect the UPS upon receipt. Any damage to the packaging or unit is not covered under warranty. Contact your parcel carrier. 1) Recharge the batteries The UPS may be used immediately upon receipt. Recharging the batteries at least eight hours before using the UPS is recommended. Energy loss may occur during shipping or storage. To recharge the battery, simply plug the UPS into an AC outlet. Once the power cord is connected, the UPS batteries will automatically start charging. 2) Connect the loads Plug your primary equipment into the battery power-supplied outlets UPS 1 and UPS 2 . Plug your peripheral equipment to the bypass outlet. Do not plug high-current equipment such as power amplifiers, projectors, and large mixing consols into the UPS 1 or 2 outlets, as they may cause the circuit breaker to trip. It is recommended that heavy loads be connected to the bypass outlet. 3) Connect the telephone If you wish to protect a fax or modem, connect the telephone cable from the wall outlet to the "IN" jack. Connect the telephone cable (provided) from the "OUT" jack to the fax or modem. These ports are not for network protection. 4) Connect to the utility power Plug the UPS to a grounded AC receptacle.
3
Avoid using extension cords. If used, make sure they are rated for at least 15 amps. 5) UPS self-test The UPS will conduct a self-test each time it is switched on. Do not add or remove any equipment while the UPS conducts this selftest; wait until the Power indicator lights up, once completed, switch on your equipment. 6) Overload protection If an overload situation (more than 5 amps load) is detected during self-test, the UPS audible alarm will activate, emitting a long beep and then will automatically shut down the system. If this occurs, unplug at least one piece of equipment from the battery supplied outlets. Switch off the UPS, wait 5 seconds and check to make sure the circuit breaker is set, then switch it on again. 7) Optimal battery status To maintain the optimal status of the battery, leave the UPS plugged in at all times. 8) Self-protection feature The UPS is equipped with a self-protection feature which prevents people from tampering with the unit and subsequently damaging it. It is programmed so that once it is switched off, the user must wait 5 seconds before switching it on again. 9) Storage Cover and store the UPS with the battery fully charged. During extended storage, recharge the batteries every three months to ensure battery life.
SB-1000 MANUAL OPE R AT I O N
1) Operation check It is recommended that the user perform a simulation test when using the UPS for the first time or when adding an additional piece of equipment. Conduct a simulation-test: first, switch on the UPS and wait for the power indicator to light up, then simply unplug the UPS to simulate a utility failure. 2) Check the power requirement of your equipment A. Make sure the total power of your equipment does not exceed rating capacity. (600W / 1000VA) B. Also make sure the equipment you plugged into the Battery Power-Supplied outlets does not require total power exceeding the capacity of the UPS (600W / 1000VA). Otherwise, overload may occur and cause the circuit breaker to trip. 3) Limited rating power of UPS When a utility failure occurs, the UPS output outlets will supply power to your equipment from its battery, and the alarm will beep every 5 seconds. Be sure that your equipment is running under the limited rating power. Plug the UPS back into the existing power source. Repeat the test a few times to make sure the UPS works properly and to determine the expected runtime.
The UPSMON series software acts as a standard RS-232 interface to perform monitoring functions, and then provides an orderly shutdown of a computer in the event of power failure. Moreover, UPSMON displays all the diagnostic symptoms on monitor, such as Voltage, Frequency, and Battery level, etc. The software is available for DOS, Windows 3.1x, Windows 95/97/2000/ME/XP, Windows NT or later, Novell Netware. 2) Characteristics of the computer interface port The computer interface port has the following characteristics: The communication port on the back of the UPS may be connected to the host computer. This port allows the computer to monitor the status of the UPS and control the operation of the UPS, in some cases. Its major functions normally include some or all of the following: · · · To broadcast a warning when power fails To close any open file before the batteries are exhausted To turn-off the UPS
BATTERY CABINET
1) Battery life of the UPS The battery life of the UPS is about 3-6 years under normal usage. 2) Battery Replacement Once the UPS's batteries is no longer useful, it must be replaced. Please contact Furman service personnel for replacement (see service section).
SOF T WA R E & C O M P U T E R INTE R FA C E
1) Power Monitoring Software
4
SB-1000 MANUAL ONE YEAR LIMITED WARRANTY
Furman Sound, Inc., having its principal place of business at 1997 South McDowell Blvd., Petaluma, CA 94954 ("Manufacturer") warrants its SB-1000 (the "Product") as follows: Manufacturer warrants to the original Purchaser of the Product that the Product sold hereunder will be free from defects in material and workmanship for a period of one year from the date of purchase. The battery is warranted for a period of 90 days. The Purchaser of the product is allowed fifteen days from the date of purchase to complete warranty registration by mail or on-line at the Furman website. If the Product does not conform to this Limited Warranty during the warranty period (as herein above specified), Purchaser shall notify Manufacturer in writing of the claimed defects. If the defects are of such type and nature as to be covered by this warranty, Manufacturer shall authorize Purchaser to return the Product to the Furman factory or to an authorized Furman repair location. Warranty claims should be accompanied by a copy of the original purchase invoice showing the purchase date; this is not necessary if the Warranty Registration was completed either via the mailed in warranty card or on-line website registration. Shipping charges to the Furman factory or to an authorized repair location must be prepaid by the Purchaser of the product. Manufacturer shall, at its own expense, furnish a replacement Product or, at Manufacturer's option, repair the defective Product. Return shipping charges back to Purchaser will be paid by Manufacturer. THE FOREGOING IS IN LIEU OF ALL
5
OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Manufacturer does not warrant against damages or defects arising out of improper or abnormal use of handling of the Product; against defects or damages arising from improper installation, against defects in products or components not manufactured by Manufacturer, or against damages resulting from such nonManufacturer made products or components. This warranty shall be cancelable by Manufacturer at its sole discretion if the product is modified in any way without written authorization from Furman Sound. This warranty also does not apply to Products upon which repairs have been affected or attempted by persons other than pursuant to written authorization by Manufacturer. THIS WARRANTY IS EXCLUSIVE. The sole and exclusive obligation of Manufacturer shall be to repair or replace the defective Product in the manner and for the period provided above. Manufacturer shall not have any other obligation with respect to the Products or any part thereof, whether based on contract, tort, strict liability or otherwise. Under no circumstances, whether based on this Limited Warranty or otherwise, shall Manufacturer be liable for incidental, special, or consequential damages. Manufacturer's employees or representatives' ORAL OR OTHER WRITTEN STATEMENTS DO NOT CONSTITUTE WARRANTIES, shall not be relied upon by Purchaser, and are not a part of the contract for sale or this limited warranty. This Limited Warranty states the entire
SB-1000 MANUAL
obligation of Manufacturer with respect to the Product. If any part of this Limited Warranty is determined to be void or illegal, the remainder shall remain in full force and effect.
SERVICE
Before returning any equipment for repair, please be sure that it is adequately packed and cushioned against damage in shipment, and that it is insured. We suggest that you save the original packaging and use it to ship the product for servicing. Also, please enclose a note giving your name, address, phone number and a description of the problem. NOTE: All equipment being returned for repair must have a Return Authorization (RA) Number. To get ... |
|||||||
| Know our Partners | Frequently Asked Questions | Contact Diplodocs team | Last searches Latest additions |
Sitemap | ![]() |
||||||||
| Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | |||||||||||||
|
|
Copyright © 2005 - 2008 - Diplodocs -
All Rights Reserved. Designated trademarks and brands are the property of their respective owners. |