User Information ......................................................... Using LCD Keypads Introduction ................................................................... User Code Types .......................................................... Setting The System ...................................................... Unsetting The System .................................................. Part Setting The System ............................................... Area Setting .................................................................. Removing Zones........................................................... Testing The System ...................................................... Viewing The Event Log ................................................. Changing The Chime Status......................................... Programming User Codes ............................................ Programming Time & Date ........................................... User Initiating Remote Access ..................................... Resetting After An Alarm .............................................. Using LED Keypads.................................................... Setting The System ...................................................... Unsetting The System .................................................. Part Setting The System ............................................... Area Setting .................................................................. Removing Zones........................................................... Testing The System ...................................................... Viewing The Event Log ................................................. Changing The Chime Status......................................... Programming User Codes ............................................ User Initiating Remote Access Resetting After An Alarm .............................................. LED Display Glossary ................................................... System Attributes.......................................................... Service Record ............................................................. User Chart .................................................................... ACE Instructions ........................................................... Programming ACE Keyfobs onto your System ............. 27 - 28 29 - 30 31 - 33 33 34 35 36 3 3-4 5 6 6-7 8 9 10 11 - 12 12 - 13 13 - 16 17 18 19 - 20 21 21 21 22 23 23 - 24 24 25 26 26 - 27 2
Page 1
User Manual
GARDTEC 800 Series
User Information
Customer Name:-
Customer Address:-
Tick
Tick
Tick
Control Panel Model
No of Keypads Keypad 1 Location Keypad 2 Location Keypad 4 Location Keypad 5 Location (840) Keypad 6 Location (840) Keypad 7 Location (840) Keypad 8 Location (840) ACE Mode (if fitted) Keyswitch 1 Location Keyswitch 2 Location Keyswitch 3 Location Keyswitch 4 Location Keyswitch 5 Location Keyswitch 6 Location Keyswitch 7 Location Keyswitch 8 Location Installation Company Name:Type Type Type Type Type Type Type Normal Security High Security Reserved User Code User No. Reserved User Code User No. Reserved User Code User No. Reserved User Code User No. Reserved User Code User No. Reserved User Code User No. Reserved User Code User No. Reserved User Code User No.
Installation Company Address:-
Installation Company Tel.
Fax.
Other Information:-
Note: Please ensure this section is completed by the installation engineer
Page 2
GARDTEC 800 Series
User Manual
Introduction
The Gardtec 800 Series of control panels consists of 3 models, the Gardtec 800, the Gardtec 816 and the Gardtec 840. Two types of display variation are also available, LCD giving two rows of 16 character English text and LED giving two 7 segment LED digits.Throughout this manual references will be made to the specific model of control panel and also the display type. You may find this information from the user information section on page 2 of this manual. Please take time to familiarise yourself with the type of equipment fitted to your premises as it will prove invaluable whilst using this manual.
User Code Types
Four types of User Codes are available on the Gardtec 800, and six types on the Gardtec 816, each user code type allows for different levels of access. In total 7 User codes may be programmed by a Master Level User Code. User number 1 will always be a Master Level User but the remaining 6 User Codes may be programmed (by a Master Code) to the required level of access. These may be changed at any time via a Master level code The User Code levels available and the functions available for the levels are:1 = Set Only 2 = Main User Only Allows for the setting of the system. Allows Setting, Part Setting, Zone Remove (if programmed by engineer), System Test, Unsetting, Reset after Alarm (if programmed by engineer).
3 = User
Allows Setting, Part Setting, Reset after Alarm (if programmed by engineer), Unsetting. Allows Setting, Unsetting, Zone Remove (if programmed by engineer), Test System, View Log, Chime On/Off, User Codes, Set Time/Date, Reset After Alarm (if programmed by engineer), Unsetting. Full System Setting (from unset system), Cleaner Area Unsetting (from set system), Cleaner Part Set (from part cleaner set system). Initiates a Duress call to Central Station whilst appearing to operate the system as normal.
4 = Master (User 1 always Master)
5 = Cleaner (816 Only)
6 = Duress (816 Only) Note:
For information on using Duress on the Gardtec Series see Using Duress Section.
Page 3
User Manual
GARDTEC 800 Series
User Code Types
Ten types of User Codes are available on the Gardtec 840, and each type allows for different levels of access. In total 47 User codes may be programmed by a Master Level User Code to any of the ten types. User number 1 will always be a Master Level User but the remaining 46 User Codes may be programmed to the required level of access. The Code Levels should be viewed as two groups, global codes that give system control and area codes that give area control. The User Code levels available and the functions available for the levels are:Global Code Levels 0 = Set Only 1 = Main Only Allows for the setting of the system. Allows Setting, Part Setting, Area Setting, Zone Remove, System Test, Unsetting. Allows Setting, Part Setting, Area Setting, Zone Remove, System Test, Viewing the Log, Chime On/Off, Program User Codes, Set Time/Date, Unsetting.
3 = Master
Area Code Levels 2 = Area 1 Allows Area 1 Setting, Area 1 Part Setting, Area 1 Unsetting. Full System Setting (from unset system), Cleaner Area Unsetting (from set system), Cleaner Part Set (from part cleaner set system). Allows Area 2 Setting, Area 2 Part Setting, Area 2 Unsetting. Allows Area 3 Setting, Area 3 Part Setting, Area 3 Unsetting. Allows Area 1 Setting, Area 1 Part Setting, Area 1 Zone Remove, Area 1 Test, Area 1 Unsetting. Allows Area 2 Setting, Area 2 Part Setting, Area 2 Zone Remove, Area 2 Test, Area 2 Unsetting. Allows Area 3 Setting, Area 3 Part Setting, Area 3 Zone Remove, Area 3 Test, Area 3 Unsetting.
4 = Cleaner
5 = Area 2
6 = Area 3
7 = Main 1
8 = Main 2
9 = Main 3
Page 4
GARDTEC 800 Series
User Manual
Setting The System
1) With the display showing:< < < < UN-SET > > > > 01 JAN 18 : 58 : 01
2)
Enter the User code (followed by YES if Master or Main type code has been used). The display will show:and a continuous exit tone will sound (1 2 3 C may not show on Gardtec 800 & 816)
EXIT Now ! 1 2 3 C All Zones ON 15
3)
Exit the premises via the authorised exit route (the exit tone will change if any detectors are violated during exit) Once the premises are secure listen that the exit tone returns to the continuous tone.
4)
5)
Wait until the exit tone finishes before leaving.
Note:
Setting the system with an area code (840 Only) will set only the area associated with that code. Setting an unset system with a cleaner code will set the full system.
Note:
Setting & Unsetting the System via a Keyswitch
One of two types of keyswitch(es) may have been fitted to your system. Normal To set the system with a normal keyswitch, insert the key and turn to the ON position then remove the key. To unset insert the key and turn to the OFF position. Biased To set the system with a biased keyswitch, insert the key and turn it then return the key to the original position and remove. To unset repeat this operation.
Page 5
User Manual
GARDTEC 800 Series
Unsetting The System
1) Enter the premises via the authorised entry route (the broken entry tone will sound), proceed to the keypad.
2)
At the keypad enter a valid code, the display will show:(Area information may be shown on 840)
< < < < UN-SET > > > > 01 JAN 18 : 58 : 01
3)
The system is now unset.
Note:
If an Area Code (840 Only) has been entered only the area associated with that code will be unset. If a Cleaner Code has been entered only the cleaner area will be unset.
Note:
Part Setting The System (using Master & Main type codes)
1) With the display showing:< < < < UN-SET > > > > 01 JAN 18 : 58 : 01
2)
Enter a Master or Main type code, the display will show for example:(User Name on 816 & 840 Only) Press 1, 2 or 3 (for Part 1, 2 or 3), the display will show for example:(1 2 3 may not show on Gardtec 800 & 816)
Do you want to . . Set , STUART ?
3)
EXIT Now! Part 1
123C 15
Note:
(840 Only) If a Global code (Master or Main) has been used all areas that are being set will be Part 1 set. (840 Only) If an Area Main code has been used only Part 1 set for that associated area will occur.
Note:
Page 6
GARDTEC 800 Series
4) The exit tone may or may not be heard dependant on the system settings.
User Manual
5)
Exit the premises or retire to an unprotected part of the system. At the end of the exit time either the exit sounder will stop or a single beep will be emitted (dependant on system settings).
Part Setting System (using Area 1, 2 or 3 codes)
1) With the display showing:< < < < UN-SET > > > > 01 JAN 18 : 58 : 01
2)
Enter an Area Code (1, 2 or 3), the exit tone will sound and the display will show for example:-
EXIT Now ! 1 All Zones ON
15
3)
Press NO then 1, 2 or 3 (for the Part Set you require), the display will show for example:-
EXIT Now ! 1 Part 1
20
4)
The exit sounders may or may not go silent this will depend on the system settings.
5)
Exit the premises or retire to an unprotected part of the system. At the end of the exit time either the exit sounder will stop or a single beep will be emitted (dependant on system settings).
Page 7
User Manual
GARDTEC 800 Series
Area Setting (using Master or global Main codes)
Areas will need to have been set up by the installation company. 1) With the display showing:< < < < UN-SET > > > > 01 JAN 18 : 58 : 01
2)
Enter a Master or global Main code, the display will show for example:-
Do you want to . . Set. ELIZABETH ?
3)
Press YES to start setting the system, the exit tone will sound and the display will show:-
EXIT Now ! 1 2 3 C All Zones ON 30
4)
To turn Area 1 Off press YES, 1 and / or To turn Area 2 Off press YES, 2 and / or To turn Area 3 Off press YES, 3 and / or To turn the Cleaner Area Off press YES, 0 As areas are turned off they will be removed from the display.
5)
Exit the premises or retire to an un-protected area (as detectors are violated the continuous exit tone will change). Areas must first be programmed by the installation company before they will appear on the display.
Note:
Area Setting (using Area codes)
Area codes are only effective to their own area with the exception of the cleaner area. This may be turned off by an area code (only if all areas are in the unset condition). Use is the same as Setting the system shown on page 5 but only the relevant area will be set
Page 8
GARDTEC 800 Series
User Manual
Removing Zones (Master & Main codes only)
If programmed by the installation company individual zones may be removed, this may only be done by a Master or Main level of code. It should be noted that if an Area Main code is being used, only zones associated with that area may be removed. 1) With the display showing:< < < < UN-SET > > > > 01 JAN 18 : 58 : 01
2)
Enter a Master or Main level code, the display will show:(User Names on 816 & 840 Only)
Do you want to . . Set . STUART ?
3)
Press NO, the display will show:-
Do you want to . . REMOVE Zones ?
4)
Press YES, the display will show:-
Enter Zone No. - then + YES or - NO
5)
Enter the zone number you wish to remove followed by YES (pressing NO will 'un-remove' a zone), the display will show:Repeat step 5 until you have removed all the required zones. Press 0 to escape, the display will show:Press YES, the continuous exit tone will sound. Exit the premises via the authorised exit route ( the exit tone will change as detectors are ...