9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your GATEWAY PJ-G210 : user manual, user guide, instruction manual.
Search a brand
Advanced Search

User manual GATEWAY PJ-G210 - INSTALLATION GUIDE

Diplodocs help download the user guide GATEWAY PJ-G210 - INSTALLATION GUIDE .

Download the complete user guide (288 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide GATEWAY PJ-G210 - INSTALLATION GUIDE

Detailed instructions for use are in the User's Guide.

Installation and Assembly - Security Projector Mount for GatewayTM 210 Projector R Model: PJ-G210 Reference Gateway 8007000 This product is intended for use with UL Listed products and must be installed by a qualified professional installer. Maximum Load Capacity: 20 lb (9.1 kg) Read instruction sheet before you start installation and assembly. WARNING the combined weight of projector mount and projector. IMPORTANT! Be sure not to touch the projector while tightening the set screw on the ball and socket mount. This may cause the image to be unaligned when you let go. IMPORTANT! Turn to the appropriate page for your application and ceiling condition. Three Different Applications: Flush Mount ..................................................................................................................................... step 3, page 5 Threaded Rod .................................................................................................................................. step 4, page 5 Extension Column ........................................................................................................................................ page 6 Installation Conditions: To Wood Joist Finished Ceilings, Exposed Wood Joists, or Wood Beam Ceilings ........................................................................................ page 3 To Concrete Ceilings .................................................................................................................................... page 4 Installer must verify that the ceiling will safely support 1 of 8 Visit the Peerless Web Site at www.peerlessindustries.com ISSUED: 04-21-03 SHEET #: 055-9158-1 For customer service call 1-800-729-0307 or 708-865-8870. Before you start check the parts list to insure all of the parts shown are included. Parts List Description A ball and socket assembly B 4 mm security allen wrench C M5 x .8 x 10 mm socket pin type F screw D E 1 1 Qty. 1 1 1 1 1 2 1 2 1 2 1 Part Number 055-0365 560-9646 520-1164 520-1109 530-9303 5S1-015-C03 142-1006 590-1050 580-1013 520-1084 055-1366 /4 - 20 x 3/8 socket pin screw /4 - 20 x /8 nut 3 F #14 x 2.5 phillips hex head wood screw G ceiling plate H .25" ID x .56" OD x .26 spacer I J extension column connector 10-32 x /8 socket pin screw 3 K bracket For Missing Parts, contact customer service at 1-800-729-0307. K C A D E I H B F J G Note: Actual parts may appear slightly different than illustrated. .ASTENERS 2 of 8 Visit the Peerless Web Site at www.peerlessindustries.com ISSUED: 04-21-03 SHEET #: 055-9158-1 For customer service call 1-800-729-0307 or 708-865-8870. Installation To Wood Joist .inished Ceilings, Exposed Wood Joists, or Wood Beam Ceilings Drill two 5/32" (4 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach ceiling plate (G) with two #14 x 2.5" (6 mm x 65 mm) wood screws (F) as shown using 3/8" (10 mm) socket wrench. Tighten wood screws (F) so ceiling plate (G) is firmly attached. DO NOT TIGHTEN WITH EXCESSIVE FORCE! Overtightening can cause stress damage to wood screws (F) greatly reducing their holding power! Tighten to 80 in · lb (9 N.M.) maximum torque. WARNING: It is the responsibility of the installer to verify that the ceiling will safely support the combined load of all attached hardware and components. IMPORTANT: Be sure to drill holes into the joist CENTER! WOOD JOIST CEILING G F F WOOD JOIST CEILING For optional Cord Management, install two spacers (H) between ceiling plate (G) and ceiling. H H G F F 3 of 8 Visit the Peerless Web Site at www.peerlessindustries.com ISSUED: 04-21-03 SHEET #: 055-9158-1 For customer service call 1-800-729-0307 or 708-865-8870. Installation to Concrete Ceilings ACC 203 (Alligator® concrete anchors) are recommended. Drill two 1/4" (6 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach ceiling plate (G) using two concrete anchors and #14 x 2.5" wood screws (F) as shown in Illustration A and 1, 2, and 3 (below). Tighten all fasteners. IMPORTANT: It is the responsibility of the installer to verify that the ceiling will safely support the combined load of all attached hardware and components. CAUTION: Tighten wood screws so ceiling plate (G) is firmly attached. But DO NOT TIGHTEN WITH EXCESSIVE FORCE! Overtightening can cause stress damage to wood screws, greatly reducing their holding power! Tighten to 80 in · lb (9 N.M.) maximum torque. concrete anchor CONCRETE CEILING G 1 concrete ceiling F concrete anchor Drill hole and insert anchor Illustration A 2 G F concrete anchor Place ceiling plate over anchor and secure with screw 3 FOR DIRECT ATTACHMENT TO LOAD BEARING CONCRETE ONLY! Concrete expansion anchors are not intended for attachment to concrete ceilings covered with a layer of plaster, drywall, or other finishing material. If mounting to concrete ceiling covered with plaster / drywall is unavoidable, plaster / drywall must be counterbored as shown below. INCORRECT CUTAWAY VIEW metal bracket concrete metal bracket F concrete anchor CORRECT concrete After repeating step one tighten all fasteners plaster/ dry wall plaster/ dry wall 4 of 8 Visit the Peerless Web Site at www.peerlessindustries.com ISSUED: 04-21-03 SHEET #: 055-9158-1 For customer service call 1-800-729-0307 or 708-865-8870. .lush Mount Application Screw ball and socket assembly (A) into ceiling plate (G). Align the notch with one of the four holes of the ceiling plate (G) and secure ball and socket assembly (A) with a M5 x 10 mm socket pin screw (C) using security allen wrench (B) as shown in detail 1. Skip to step 6. WOOD JOIST NOTCH G C A CEILING G DETAIL 1 THREADED ROD B A 1/2 -13 THREADED ROD ACC 810 Installation to Threaded Rod Accessory ACC 810, threaded rod adapter, is required. (Sold Separately) Screw ACC 810 into extension column connector (I). Align slot in ACC 810 with one of the top holes in extension column connector (I). Insert and tighten one 10-32 x 3/8 socket pin screw (J) through extension column connector (I) into slot on ACC 810 using 4 mm security allen wrench (B). See detail 2. Align slot in ball and socket mount (A) to one of the bottom holes in extension column connector (I). Insert and tighten one 10-32 x 3/8 socket pin screw (J) through extension column connector (I) into slot in ball and socket mount (A). See detail 3. Skip to step 6. SLOT SLOT ACC 810 I SLOT J DETAIL 2 I THREADED ROD ACC 810 SLOT I A DETAIL 3 A J 5 of 8 Visit the Peerless Web Site at www.peerlessindustries.com ISSUED: 04-21-03 SHEET #: 055-9158-1 For customer service call 1-800-729-0307 or 708-865-8870. Installation to Extension Column Screw extension column to ceiling plate (G). Align the notch with one of the four holes in the ceiling plate (G) and secure extension column with a M5 x 10 mm socket pin screw (C) using security allen wrench (B). See detail 4. Screw extension column connector (I) to extension column. Align slot in extension column with one of the top holes in extension column connector (I). Insert and tighten one 10-32 x 3/8 socket pin screw (J) through extension column connector (I) into slot on extension column using security allen wrench (B). See detail 5. Screw ball and socket mount (A) to extension column connector (I). Align slot in ball and socket mount (A) to one of the bottom holes in extension column connector (I). Insert and tighten one 10-32 x 3/8 socket pin screw (J) through extension column connector into slot in ball and socket mount (A) using security allen wrench (B). See detail 6. G C G EXTENSION COLUMN (SOLD SEPARATELY) EXTENSION COLUMN DETAIL 4 SLOT EXTENSION COLUMN I SLOT I SLOT J A DETAIL 5 EXTENSION COLUMN ACC 850 - EXTENSION COLUMN CONNECTOR WITH CORD MANAGEMENT - MAY BE USED IN PLACE OF EXTENSION COLUMN CONNECTOR (I). THIS ALLOWS INSTALLER TO ROUTE CORDS UP THROUGH THE EXTENSION COLUMN. (SOLD SEPARATELY) I A SLOT J DETAIL 6 6 of 8 Visit the Peerless Web Site at www.peerlessindustries.com ISSUED: 04-21-03 SHEET #: 055-9158-1 For customer service call 1-800-729-0307 or 708-865-8870. Attach bracket (K) to ball and socket assembly (A) using 1/4 - 20 nut (E). A K E Press button on side of projector to lift projector foot. Slide bracket (K) under projector foot. Push foot down. Secure bracket (K) with 1/4 - 20 socket pin screw (D). CEILING To adjust roll, pitch, and yaw loosen the set screw (shown below) using security allen wrench (B) or standard 4 mm allen wrench. You should be able to just slightly loosen the screw so that your adjustments can be set without having to hold the projector. Move projector to desired position and slowly tighten set screw. Note: Be sure not to touch the projector while tightening the set screw. This may cause the image to be unaligned when you let go. IMPORTANT: Security allen wrench (B) is your key for projector removal. Store it in a safe place. WOOD JOIST CEILING SET SCREW CUTAWAY VIEW OF CEILING PLATE (G) WOOD JOIST PROJECTOR D A PROJECTOR K PROJECTOR FOOT 7 of 8 Visit the Peerless Web Site at www.peerlessindustries.com © 2003 Peerless Industries, Inc. All rights reserved. ISSUED: 04-21-03 SHEET #: 055-9158-1 For customer service call 1-800-729-0307 or 708-865-8870. PEERLESS LIMITED WARRANTY Peerless warrants its products, under normal use, to be free from defects in material and workmanship for a period of five years from the date of purchase. Peerless, at its sole discretion, will repair or replace such defective equipment free of charge provided the products are returned prepaid to Peerless. Thereafter, repairs will be made at established factory prices. Unauthorized service or repairs by anyone other than authorized Peerless personnel renders this Warranty void and releases Peerless from any further responsibility or obligation. Any damage caused by failure to observe proper packing or to observe instructions for installation, by accident or in transit or elsewhere will not be covered by the Warranty. This Warranty is in lieu of all other Warranties expressed or implied, and no one is authorized to assume any liability on behalf of Peerless or impose any obligation on it in connection with the sale of any product other than as outlined above. In no event will responsibility be assumed or implied for consequential damages arising from the theft of any product secured by a Peerless security device, by delay of installation, interrupted operation or other causes. 8 of 8 Visit the Peerless Web Site at www.peerlessindustries.com ISSUED: 04-21-03 SHEET #: 055-9158-1 For customer service call 1-800-729-0307 or 708-865-8870. ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.